Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Focusing neutron guides for VULCAN ' Design Aspects, Estimated Performance, and Detector Deployment

The neutron optics design and performance for VULCAN ' the SNS Engineering Diffractometer ' is presented. A gradually tapered focusing neutron guide is used to deliver desired beam divergence at sample position. Selection of instrument resolution is achieved with an interchangeable guide-collimator system in the last 3-m of the neutron guide system. The effect of focusing on instrument resolution was evaluated and the strategy for detector deployment is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of position-sensitive time-of-flight spectrometer for fission fragment research

A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEtermination in fission Research (SPIDER) is a 2E–2v spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with α-particles from 229Th and its decay chain and α-particles and spontaneous fission fragments from 252Cf. Each detector module is comprised of thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times were measured with 250 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to a precision of 0.5%. As a result, an ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.

2E-2v↗

Development of an array of liquid-scintillator-based bar detectors: SABRE

We present that an array of neutron detectors based on liquid scintillator technology has been developed for nuclear reaction studies, in particular measurements with radioactive ion beams (RIBs). Reaction measurements with RIBs often involve low reaction yields and high gamma-induced backgrounds, which requires high solid angle coverage, high efficiency, and background reduction capability. The kinematics of the reaction neutrons require energy and position determination with good resolution, but preferably without a large number of readouts to minimize cost. To address these requirements, the Scintillation Array of Bars for Reaction Experiments (SABRE) consists of five 12” long, 2” diameter bar detectors filled with organic liquid scintillator and capped at both ends with individually read-out superbialkali photomultiplier tubes (PMTs). Finally, in-house purification of the scintillator mixtures resulted in improved light collection. Discussion of the liquid scintillator development and the design and commissioning of SABRE will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ordering in bio-inorganic hybrid nanomaterials probed by in situ scanning transmission X-ray microscopy

Here, phospholipid bilayer coated Si nanowires are one-dimensional (1D) composites that provide versatile bio-nanoelectronic functionality via incorporation of a wide variety of biomolecules into the phospholipid matrix. The physiochemical behaviour of the phospholipid bilayer is strongly dependent on its structure and, as a consequence, substantial modelling and experimental efforts have been directed at the structural characterization of supported bilayers and unsupported phospholipid vesicles; nonetheless, the experimental studies conducted to date have exclusively involved volume-averaged techniques, which do not allow for the assignment of spatially resolved structural variations that could critically impact the performance of the 1D phospholipid-Si NW composites. In this manuscript, we use scanning transmission X-ray microscopy (STXM) to probe bond orientation and bilayer thickness as a function of position with a spatial resolution of ~30 nm for Δ9-cis 1,2-dioleoyl-sn-glycero-3-phosphocholine layers prepared Si NWs. When coupled with small angle X-ray scattering measurements, the STXM data reveal structural motifs of the Si NWs that give rise to multi-bilayer formation and enable assignment of the orientation of specific bonds known to affect the order and rigidity of phospholipid bilayers.

36 MATERIALS SCIENCE↗

Intracellular Dynamics of Superparamagnetic Iron Oxide Nanoparticles for Magnetic Partical Imaging

Superparamagnetic iron oxide nanoparticles (SPIONs) are a foundational platform for a variety of biomedical applications. Of particular interest is Magnetic Particle Imaging (MPI), which is a growing area of research and development due to its advantages including high resolution and sensitivity with positive contrast. There has been signicant work in the area of in vivo optimization of SPIONs for MPI as well as their biodistribution in and clearance from the body. However, little is known about the dynamics of SPIONs following cellular internalization which may limit their usefulness in a variety of potential imaging and treatment applications. This work shows a clear 20% decrease in magnetic performance of SPIONs, as observed by Magnetic Particle Spectroscopy (MPS), after internalization and systematic consideration of applicable factors that aect SPION signal generation, including microstructure, environment, and interparticle interactions. There is no observed change to SPION microstructure after internalization, and the surrounding environment plays little to no role in magnetic response for the SPIONs studied here. Interparticle interactions described by dipole-dipole coupling of SPIONs held close to one another after internalization are shown to be the dominant cause of decreased magnetic performance in cells. These conclusions were drawn from transmission electron microscopy (TEM) image analysis at relevant length scales, experimentally prepared and characterized SPIONs in varied environmental conditions, and theoretical modeling with Monte Carlo simulations.

Teeman, Eric M.↗

A rotatable electron spectrometer for multicoincidence experiments

We have developed a rotatable hemispherical spectrometer with good energy and angular resolution, which can be positioned with the lens axis arbitrarily within a solid angle of 1 {pi}. The collection angle of the emitted electrons with respect to the polarization axis of the light is set by means of a three-axes goniometer, operating under vacuum. An important requirement for this setup was the possibility to perform coincidences between the electron analyzed by the spectrometer and one or several other particles, such as ions, electrons, or photons. The lens system and the hemispheres have been designed to accommodate such experimental demands, regarding parameters such as the resolving power, the acceptance angle, or the width of the kinetic energy window which can be recorded for a given pass energy. We have chosen to detect the impact position of the electron at the focal plane of the hemispherical analyzer with a delay line detector and a time-to-digital converter as acquisition card rather than using a conventional charge-coupled device camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for the monitoring of metal recrystallization based on the in-situ measurement of the elastic energy release using neutron diffraction

A method is proposed for the monitoring of metal recrystallization using neutron diffraction that is based on the measurement of stored energy. Experiments were performed using deformed metal specimens heated in-situ while mounted at the sample position of the High Resolution Powder Diffractometer, HRPD (ISIS Facility), UK. Monitoring the breadth of the resulting Bragg lines during heating not only allows the time-dependence (or temperature-dependence) of the stored energy to be determined but also the recrystallized fraction. The analysis method presented here was developed using pure nickel (Ni270) specimens with different deformation levels from 0.29 to 0.94. In situ temperature ramping as well as isothermal annealing was undertaken. The method developed in this work allows accurate and quantitative monitoring of the recrystallization process. The results from neutron diffraction are satisfactorily compared to data obtained from calorimetry and hardness measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution

Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of the ATLAS forward proton Time-of-Flight detector in Run 2

We present performance studies of the Time-of-Flight (ToF) subdetector of the ATLAS Forward Proton (AFP) detector at the LHC. Efficiencies and resolutions are measured using high-statistics data samples collected at low and moderate pile-up in 2017, the first year when the detectors were installed on both sides of the interaction region. While low efficiencies are observed, of the order of a few percent, the resolutions of the two ToF detectors measured individually are 21 ps and 28 ps, yielding an expected resolution of the longitudinal position of the interaction, z vtx , in the central ATLAS detector of 5.3 ± 0.6 mm. This is in agreement with the observed width of the distribution of the difference between z vtx , measured independently by the central ATLAS tracker and by the ToF detector, of 6.0 ± 2.0 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DISCOVERY OF THE ZEEMAN EFFECT IN THE 44 GHz CLASS I METHANOL (CH{sub 3}OH) MASER LINE

We report the discovery of the Zeeman effect in the 44 GHz Class I methanol (CH{sub 3}OH) maser line. The observations were carried out with 22 antennas of the Expanded Very Large Array toward a star-forming region in OMC-2. Based on our adopted Zeeman splitting factor of z = 1.0 Hz mG{sup -1}, we detect a line-of-sight magnetic field of 18.4 {+-} 1.1 mG toward this source. Since such 44 GHz CH{sub 3}OH masers arise from shocks in the outflows of star-forming regions, we can relate our measurement of the post-shock magnetic field to field strengths indicated by species tracing pre-shock regions, and thus characterize the large-scale magnetic field. Moreover, since Class I masers trace regions more remote from the star-forming core than Class II masers, and possibly earlier phases, magnetic fields detected in 6.7 GHz Class II and 36 and 44 GHz Class I methanol maser lines together offer the potential of providing a more complete picture of the magnetic field. This motivates further observations at high angular resolution to find the positional relationships between Class I and Class II masers, and masers at various frequencies within each category. In particular, CH{sub 3}OH masers are widespread in high- as well as intermediate-mass star-forming regions, and our discovery provides a new method of studying the magnetic field in such regions, by observing small physical scales that are not accessible by any other lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatially dependent Rabi oscillations: An approach to sub-diffraction-limited coherent anti-Stokes Raman-scattering microscopy

We present a theoretical investigation of coherent anti-Stokes Raman scattering (CARS) that is modulated by periodically depleting the ground-state population through Rabi oscillations driven by an additional control laser. We find that such a process generates optical sidebands in the CARS spectrum and that the frequency of the sidebands depends on the intensity of the control laser light field. We show that analyzing the sideband frequency upon scanning the beams across the sample allows one to spatially resolve emitter positions where a spatial resolution of 65 nm, which is well below the diffraction limit, can be obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

Desmearing small-angle scattering data by central moment expansions of instrument resolution

This study introduces an enhanced numerical technique tailored specifically for refining 1D small-angle scattering (SAS) intensity profiles affected by smearing. Our primary objective is to address the resolution blurring commonly encountered in SAS data, particularly in systems with clearly defined correlation peaks whose spread aligns with the width of the resolution function at corresponding Q positions. Unlike previous approaches that expanded the SAS intensity using central moment expansion, the new method focuses on expanding the resolution function itself, thus eliminating artificial oscillations observed in smeared spectra due to limitations inherent in our earlier algorithm. This method is straightforward to implement, computationally efficient and consistently performs well in numerical benchmarking. To illustrate its effectiveness, we present a case study of a lamellar phase characterized by distinct peaks in its small-angle neutron scattering intensities.

central moment expansions↗

SU-E-T-626: Accuracy of Dose Calculation Algorithms in MultiPlan Treatment Planning System in Presence of Heterogeneities

Purpose: Advanced stereotactic radiotherapy (SRT) treatments require accurate dose calculation for treatment planning especially for treatment sites involving heterogeneous patient anatomy. The purpose of this study was to evaluate the accuracy of dose calculation algorithms, Raytracing and Monte Carlo (MC), implemented in the MultiPlan treatment planning system (TPS) in presence of heterogeneities. Methods: First, the LINAC of a CyberKnife radiotherapy facility was modeled with the PENELOPE MC code. A protocol for the measurement of dose distributions with EBT3 films was established and validated thanks to comparison between experimental dose distributions and calculated dose distributions obtained with MultiPlan Raytracing and MC algorithms as well as with the PENELOPE MC model for treatments planned with the homogenous Easycube phantom. Finally, bones and lungs inserts were used to set up a heterogeneous Easycube phantom. Treatment plans with the 10, 7.5 or the 5 mm field sizes were generated in Multiplan TPS with different tumor localizations (in the lung and at the lung/bone/soft tissue interface). Experimental dose distributions were compared to the PENELOPE MC and Multiplan calculations using the gamma index method. Results: Regarding the experiment in the homogenous phantom, 100% of the points passed for the 3%/3mm tolerance criteria. These criteria include the global error of the method (CT-scan resolution, EBT3 dosimetry, LINAC positionning …), and were used afterwards to estimate the accuracy of the MultiPlan algorithms in heterogeneous media. Comparison of the dose distributions obtained in the heterogeneous phantom is in progress. Conclusion: This work has led to the development of numerical and experimental dosimetric tools for small beam dosimetry. Raytracing and MC algorithms implemented in MultiPlan TPS were evaluated in heterogeneous media.

60 APPLIED LIFE SCIENCES↗

Wavelength Dispersive X-ray Fluorescence Analysis of Actinides in Dissolved Nuclear Fuels

There is an urgent need for an instrument that can quickly measure the concentration of Plutonium and other Actinides mixed with Uranium in liquids containing dissolved spent fuel rods. Parallax Research, Inc. proposes to develop an x-ray spectrometer capable of measuring U, Np and Pu in dissolved nuclear fuel rod material to less than 10 ppm levels to aid in material process control for these nuclear materials. Due to system noise produced by high radioactivity, previous x-ray spectrometers were not capable of low level measurements but the system Parallax proposed has no direct path for undesired radiation to get to the detector and the detector in the proposed device is well shielded from scatter and has very low dark current. In addition, the proposed spectrometer could measure these three elements simultaneously, also measuring background positions with an energy resolution of roughly 100 eV making it possible to see a small amount of Pu that would be hidden under the tail of the U peak in energy dispersive spectrometers. Another nearly identical spectrometer could be used to target Am and Cm if necessary. The proposed spectrometer needs only a tiny sample of roughly 1 micro-liter (1 mm 3 ) and the measurement can be done with the liquid flowing in a radiation and chemical immune quartz capillary protected by a stainless steel rod making it possible to continuously monitor the liquid or to use a capillary manifold to measure other liquid streams. Unlike other methods such as mass spectroscopy where the sample must be taken to a remote facility and might take days for turn-around, the proposed measurement should take less than an hour. This spectrometer could enable near real-time measurement of U, Pu and Np in dilute dissolved spent nuclear fuel rod streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Large Area µRWELL Detectors for CLAS12 High Luminosity Upgrade at Jefferson Lab

The high-luminosity upgrade of the CEBAF Large Acceptance Spectrometer (CLAS12) will significantly enhance the physics reach of experiments in Hall B at JLab. However, at the current luminosity of L = 1 × 1035 cm-2 s-1, the reconstruction efficiency of charged particles in the forward region of the CEBAF Large Acceptance Spectrometer (CLAS12) is at the level of 85% and limited in part by the drift chambers inability to handle high occupancy, in the first tracking region (DC-R1) of the Forward Detector. The reconstruction efficiency is expected to drop even lower at higher luminosities with the current tracking technology. Various options under consideration to achieve the desired performance at a higher luminosity of L = 2 × 1035 cm-2 s-1 include the addition of fast tracking layers to complement DC-R1 or the replacement of DC-R1 with a different tracking detector technology altogether. In either case, a novel generation of compact, simple and robust Micro-Pattern Gaseous Detector (MPGD) known as the Resistive Micro-Well detector (µRWELL) is the ideal candidate to satisfy the requirements in terms of timing O (10 ns) and position O (100 µm) resolutions. A large µRWELL prototype, combined with a two-dimensional U-V strip readout layer based on the novel concept of capacitive-sharing approach has been developed as a proof of principle for fast tracking capabilities in the forward region of CLAS12 high-luminosity upgrade. In this talk, we will present the technical aspects of the design choices of the large µRWELL prototype under development and report on the detector assembly process and preliminary performance characteristic tests. We will also discuss the plans for the test and characterization of the prototype in beam during spring 2023 CEBAF run. Finally, we will report on ongoing R&D efforts on small prototypes with the goal to improve rate capability, spatial resolution performance and minimize material thickness.

Gnanvo, Kondo↗

Final Report: A Multi-Channel Fusion Product

The goal of this project was to measure charged fusion products from the d(d,p)t reaction in MAST-U plasmas as a function of time and position with good energy resolution using a system of up to six charged particle detectors. The data from this new diagnostic will make it possible to determine the neutral beam ion density profile as a function of R, z, and t with reduced model dependency and contribute new information to a global analysis of fast ion diagnostic data needed for the determination of the fast ion distribution function (velocity space tomography).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Numerically Exact Approach to Quantum Impurity Problems in Realistic Lattice Geometries

We review a controlled numerical approach to quantum impurity problems in realistic geometries, consisting of exactly mapping the complete lattice Hamiltonian onto an equivalent one dimensional system through a unitary transformation. The resulting dimensional and entanglement reduction allows one to study the quantum many-body problem on arbitrary d-dimensional lattices using the density matrix renormalization group (DMRG) method. The real-space resolution allows one to position the impurities at the boundary or bulk of the sample and to study screening effects due to edge or surface modes. We describe how to generalize this approach to multi-impurity problems, discuss applications and possible extensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A JWST Survey of the Supernova Remnant Cassiopeia A

We present initial results from a James Webb Space Telescope (JWST) survey of the youngest Galactic core-collapse supernova remnant, Cassiopeia A (Cas A), made up of NIRCam and MIRI imaging mosaics that map emission from the main shell, interior, and surrounding circumstellar/interstellar material (CSM/ISM). We also present four exploratory positions of MIRI Medium Resolution Spectrograph integral field unit spectroscopy that sample ejecta, CSM, and associated dust from representative shocked and unshocked regions. Surprising discoveries include (1) a weblike network of unshocked ejecta filaments resolved to ~0.01 pc scales exhibiting an overall morphology consistent with turbulent mixing of cool, low-entropy matter from the progenitor's oxygen layer with hot, high-entropy matter heated by neutrino interactions and radioactivity; (2) a thick sheet of dust-dominated emission from shocked CSM seen in projection toward the remnant's interior pockmarked with small (~1'') round holes formed by ≲0$^"_•$1 knots of high-velocity ejecta that have pierced through the CSM and driven expanding tangential shocks; and (3) dozens of light echoes with angular sizes between ~0$^"_•$1 and 1' reflecting previously unseen fine-scale structure in the ISM. NIRCam observations place new upper limits on infrared emission (≲20 nJy at 3 μm) from the neutron star in Cas A's center and tightly constrain scenarios involving a possible fallback disk. These JWST survey data and initial findings help address unresolved questions about massive star explosions that have broad implications for the formation and evolution of stellar populations, the metal and dust enrichment of galaxies, and the origin of compact remnant objects.

79 ASTRONOMY AND ASTROPHYSICS↗