Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Results of the long range position-determining system tests

The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

Rhode, F. W.↗

Shuttle Global Positioning (GPS) System design study

Investigations of certain aspects and problems of the shuttle global positioning system GPS, are presented. Included are: test philosophy and test outline; development of a phase slope specification for the shuttle GPS antenna; an investigation of the shuttle jamming vulnerability; and an expression for the GPS signal to noise density ratio for the thermal protection system.

Nilsen, P.↗

Triply redundant integrated navigation and asset visibility system

Methods and apparatus are described for a navigation system. A method includes providing a global positioning system fix having a plurality of tracking parameters; providing a theater positioning system fix; monitoring the plurality of tracking parameters for predetermined conditions; and, when the predetermined conditions are met, sending a notifying signal and switching to the theater positioning system fix as a primary fix. An apparatus includes a system controller; a global positioning system receiver coupled to the system controller; a radio frequency locating receiver coupled to the system controller; and an operator interface coupled to the system controller.

47 OTHER INSTRUMENTATION↗

Triply redundant integrated navigation and asset visibility system

Methods and apparatus are described for a navigation system. A method includes providing a global positioning system fix having a plurality of tracking parameters; providing a theater positioning system fix; monitoring the plurality of tracking parameters for predetermined conditions; and, when the predetermined conditions are met, sending a notifying signal and switching to the theater positioning system fix as a primary fix. An apparatus includes a system controller; a global positioning system receiver coupled to the system controller; a radio frequency locating receiver coupled to the system controller; and an operator interface coupled to the system controller.

47 OTHER INSTRUMENTATION↗

Autonomous satellite navigation methods using the Global Positioning Satellite System

This investigation considers the problem of autonomous satellite navigation using the NAVSTAR Global Positioning System (GPS). The major topics covered include the design, implementation, and validation of onboard navigation filter algorithms by means of computer simulations. The primary errors that the navigation filter design must minimize are computational effects and modeling inaccuracies due to limited capability of the onboard computer. The minimization of the effect of these errors is attained by applying the sequential extended Kalman filter using a factored covariance implementation with Q-matrix or dynamical model compensations. Peformance evaluation of the navigation filter design is carried out using both the CDC Cyber 170/750 computer and the PDP-11/60 computer. The results are obtained assuming the Phase I GPS constellation, consisting of six satellites, and a Landsat-D type spacecraft as the model for the user satellite orbit.

Murata, M.↗

Study of an orbiting tethered dumbbell system having positive orbital energy

For very long tethered systems the sum of the kinetic and potential energy can be positive. The system remains in a circular orbit as long as the masses remain vertically aligned. The system is unstable without constant control of the alignment. If the upper mass rotates forward in the direction of the orbital motion, the system escapes out of orbit. If the upper mass rotates backward, the system falls out of orbit and the lower mass impacts the body around which the system is orbiting.

Arnold, David A.↗

IGRT/ART phantom with programmable independent rib cage and tumor motion

Purpose: This paper describes the design and experimental evaluation of the Methods and Advanced Equipment for Simulation and Treatment in Radiation Oncology (MAESTRO) thorax phantom, a new anthropomorphic moving ribcage combined with a 3D tumor positioning system to move target inserts within static lungs. Methods: The new rib cage design is described and its motion is evaluated using Vicon Nexus, a commercial 3D motion tracking system. CT studies at inhale and exhale position are used to study the effect of rib motion and tissue equivalence. Results: The 3D target positioning system and the rib cage have millimetre accuracy. Each axis of motion can reproduce given trajectories from files or individually programmed sinusoidal motion in terms of amplitude, period, and phase shift. The maximum rib motion ranges from 7 to 20 mm SI and from 0.3 to 3.7 mm AP with LR motion less than 1 mm. The repeatability between cycles is within 0.16 mm root mean square error. The agreement between CT electron and mass density for skin, ribcage, spine hard and inner bone as well as cartilage is within 3%. Conclusions: The MAESTRO phantom is a useful research tool that produces programmable 3D rib motions which can be synchronized with 3D internal target motion. The easily accessible static lungs enable the use of a wide range of inserts or can be filled with lung tissue equivalent and deformed using the target motion system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Sinterator Freeform Additive Construction System (MS-FACS)

The harmful properties of lunar dust, such as small size, glass composition, abnormal surface area, and coatings of imbedded nanophase iron, lead to a unique coupling of the dust with microwave radiation. This coupling can be exploited for rapid sintering of lunar soil for use as a construction material that can be formed to take on an infinite number of shapes and sizes. This work describes a system concept for building structures on the lunar surface using lunar regolith (soil). This system uses the ATHLETE (All-Terrain Hex- Limbed Extra-Terrestrial Explorer) mobility system as a positioning system with a microwave print head (similar to that of a smaller-scale 3D printer). A processing system delivers the lunar regolith to the microwave print head, where the microwave print head/chamber lays down a layer of melted regolith. An arm on the ATHLETE system positions the layer depending on the desired structure.

Howe, Alan S.↗

Coordinated joint motion control system with position error correction

Disclosed are an articulated hydraulic machine supporting, control system and control method for same. The articulated hydraulic machine has an end effector for performing useful work. The control system is capable of controlling the end effector for automated movement along a preselected trajectory. The control system has a position error correction system to correct discrepancies between an actual end effector trajectory and a desired end effector trajectory. The correction system can employ one or more absolute position signals provided by one or more acceleration sensors supported by one or more movable machine elements. Good trajectory positioning and repeatability can be obtained. A two joystick controller system is enabled, which can in some cases facilitate the operator's task and enhance their work quality and productivity.

42 ENGINEERING↗

Coordinated joint motion control system with position error correction

Disclosed are an articulated hydraulic machine supporting, control system and control method for same. The articulated hydraulic machine has an end effector for performing useful work. The control system is capable of controlling the end effector for automated movement along a preselected trajectory. The control system has a position error correction system to correct discrepancies between an actual end effector trajectory and a desired end effector trajectory. The correction system can employ one or more absolute position signals provided by one or more acceleration sensors supported by one or more movable machine elements. Good trajectory positioning and repeatability can be obtained. A two-joystick controller system is enabled, which can in some cases facilitate the operator's task and enhance their work quality and productivity.

47 OTHER INSTRUMENTATION↗

Enforcing positivity in intrusive PC-UQ methods for reactive ODE systems

We explore the relation between the development of a non-negligible probability of negative states and the instability of numerical integration of the intrusive Galerkin ordinary differential equation system describing uncertain chemical ignition. To prevent this instability without resorting to either multi-element local polynomial chaos (PC) methods or increasing the order of the PC representation in time, we propose a procedure aimed at modifying the amplitude of the PC modes to bring the probability of negative state values below a user-defined threshold. This modification can be effectively described as a filtering procedure of the spectral PC coefficients, which is applied on-the-fly during the numerical integration when the current value of the probability of negative states exceeds the prescribed threshold. We demonstrate the filtering procedure using a simple model of an ignition process in a batch reactor. This is carried out by comparing different observables and error measures as obtained by non-intrusive Monte Carlo and Gauss-quadrature integration and the filtered intrusive procedure. The filtering procedure has been shown to effectively stabilize divergent intrusive solutions, and also to improve the accuracy of stable intrusive solutions which are close to the stability limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visual and Inertial Datasets for an eVTOL Aircraft Approach and Landing Scenario

A National Aeronautics and Space Administration (NASA) project developing computer vision algorithms for autonomous flight is producing real-world datasets with cameras mounted on aircraft. In related domains, such as autonomous driving, open datasets are key to innovation and advancement in computer vision and autonomous perception for future Advanced Air Mobility (AAM) operations. Few vision datasets, however, are publicly available in the aviation context. This paper introduces preliminary datasets containing several examples of approach and landing scenarios. The platform aircraft include a multirotor small unmanned aerial system (sUAS) and a crewed helicopter as surrogates for future electric vertical take-off and landing (eVTOL) aircraft. The dataset provides video imagery with associated inertial navigation system-global positioning system (INS-GPS) position and attitude estimates and other sensors. Surveyed locations of the visual features of the landing area are included. This dataset is the first to be released in an ongoing effort to collect and share large, diverse datasets relevant to autonomous aviation; community critique that can inform and improve future flight campaigns is welcome.

Nelson Brown↗

An online x-ray based position validation system for prostate hypofractionated radiotherapy

Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR{sub seg}) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPR{sub trig}) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR{sub seg} of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPR{sub trig} of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPR{sub trig} of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and 310°–350° (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images. Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20° arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Robust stabilization of marginally stable positive-real systems

This paper investigates the stability of the negative feedback interconnection to two positive-real systems which have poles in the closed left-half of the complex plane. A new definition of marginally strict positive real systems is introduced, and sufficient conditions are obtained for the stability of the feedback interconnection of such systems, using the Lyapunov method. The conditions obtained have direct applications to dynamic dissipative controllers for flexible spacecraft and are the least restrictive ones published to date.

Joshi, Suresh M.↗

Cross sections for production of the CO(A 1 Pi)-(X 1 Sigma) fourth positive band system and O(3 S) by photodissociation of CO2

The CO(A 1 Pi) cross sections reported here, along with previously determined electron impact results, establish the basis for calculating CO fourth positive system volume emission rates in the Martian dayglow. Calculated volume emission rates in turn determine relative distribution of photon vs. electron impact as mechanisms for producing CO(A 1 Pi) in the Mars atmosphere. The smallness of the O(1304) cross section confirms previous indirect evidence that photodissociative excitation of CO2 is not an important source of O(3 S) in the upper atmosphere of Mars.

Gentieu, E. P.↗

Gondola for High Altitude Planetary Science (GHAPS) Telescope Secondary Mirror Positioning Hexapod Issues and Alternatives

Active positioning of the GHAPS secondary telescope mirror is desired to correct for rigid body deflections due to temperature variations and gravity sag in the telescope structure that may impact optical performance. The current design concept for the secondary mirror mount uses a Commercial-Off -the-Shelf hexapod for mirror positioning and fine adjustment. The Hexapod specification states that motions as small as 0.1 microns along the optical axis and 2 microns perpendicular to the optical axis will cause optical aberrations that will require correction by repositioning the secondary mirror. In addition, the secondary mirror mount and positioning system must survive a 15g shock of parachute opening and landing during the instrument recovery operation. The secondary mirror positioning system must operate at a minimum specified temperature of -50 C. The telescope operates in the IR and the secondary mirror mount and positioning device is in the metering path between the primary and secondary mirrors. I2R losses in positioning system actuator devices, which may cause heating of the positioning system and secondary mirror, must be minimized due to the previously mentioned alignment sensitivity and the viewing spectrum of interest. The GHAPs project was cancelled on June 30, 2017. The purpose of this study is to address some of the issues identified with the hexapod secondary mirror positioning system and identify alternative approaches. This information may be used if the project is re-started at a later date.

Gondola Mirror Hexapo↗

Contactless Position Measurement System for Remote Alignment of Highly Reflective Objects

The Contactless Position Measurement System (CPMS) permits automatic alignment of highly-reflecting components that cannot or should not be touched by human hands, such as those used in SRF cavities. CPMS also has application during maintenance of fusion reactors, when the components in the reactor are radioactive. The length of time for which humans can handle the components in order to carry out maintenance or repairs is limited. We would like to measure the relative positions of such objects so we can bring them into alignment with motorized stages, thus eliminating the need for human contact. The CPMS is a computer vision system that measures the location of highly reflective components to within a fraction of a millimeter by finding the edges of silhouette images. This is done by placing a uniform, infrared backlight behind the components, and viewing each component with two low-aberration, infrared cameras. Each of these stereoscopic cameras are located within a coordinate system we set up with reference platforms, light sources, and survey cameras distributed around the perimeter of the string assembly room, or fusion reactor. We obtain stereoscopic silhouette images of each component, and we use these to determine the position of the component within our string assembly coordinate system. The CPMS combines the silhouette images with knowledge of the dimensions of the objects to obtain the relative positions of components in its field of view. These position measurements then allow us to mechanically maneuver the components into contact. Once we know where they are, we can move the components to where they are supposed to be with motorized stages or other mechanical means, check they are in the right place, and bolt them together. In Phase I, we built a prototype infrared backlights and cameras, tested it, wrote an analysis program to fit the images. At a range of 50 cm, we are able to measure the relative positions of two stainless steel flanges with an accuracy of 150 μm rms. The next steps are to test the analysis program with motorized stages, build a full-size prototype, and implement it in an cleanroom with SRF cavity assembly. This can be done in a cost effective way given the materials with which the system is designed. As Open Source Instruments achieved more in Phase I than anticipated, despite not receiving a Phase II SBIR grant, we hope to move forward with product development and sales with a testing partner.

43 PARTICLE ACCELERATORS↗