Advanced Test Reactor - A National Scientific User Facility

The ATR is a pressurized, light-water moderated and cooled, beryllium-reflected nuclear research reactor with a maximum operating power of 250 MWth. The unique serpentine configuration of the fuel elements creates five main reactor power lobes (regions) and nine flux traps. In addition to these nine flux traps there are 68 additional irradiation positions in the reactor core reflector tank. There are also 34 low-flux irradiation positions in the irradiation tanks outside the core reflector tank. The ATR is designed to provide a test environment for the evaluation of the effects of intense radiation (neutron and gamma). Due to the unique serpentine core design each of the five lobes can be operated at different powers and controlled independently. Options exist for the individual test trains and assemblies to be either cooled by the ATR coolant (i.e., exposed to ATR coolant flow rates, pressures, temperatures, and neutron flux) or to be installed in their own independent test loops where such parameters as temperature, pressure, flow rate, neutron flux, and energy can be controlled per experimenter specifications. The full-power maximum thermal neutron flux is ~1.0 x1015 n/cm2-sec with a maximum fast flux of ~5.0 x1014 n/cm2-sec. The Advanced Test Reactor, now a National Scientific User Facility, is a versatile tool in which a variety of nuclear reactor, nuclear physics, reactor fuel, and structural material irradiation experiments can be conducted. The cumulative effects of years of irradiation in a normal power reactor can be duplicated in a few weeks or months in the ATR due to its unique design, power density, and operating flexibility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hybrid power system control and operating strategy based on power system state vector calculation

Controlling a hybrid power system includes calculating a power system state vector based on energy demand and a stored data array including a matrix defined by a power system hardware configuration. The control further includes producing a power request based on the power system state vector, and varying a flow of energy amongst energy devices using drive linkages in the hybrid power system based on the power request. Related apparatus, control logic and controller structure is disclosed.

Guo, Fang↗

ARPA-E: Advancing the Electric Grid

The electric grid was designed with the assumption that all energy generation sources would be relatively controllable, and grid operators would always be able to predict when and where those sources would be located. With the addition of renewable energy sources like wind and solar, which can be installed faster than traditional generation technologies, this is no longer the case. Furthermore, the fact that renewable energy sources are imperfectly predictable means that the grid has to adapt in real-time to changing patterns of power flow. We need a dynamic grid that is far more flexible. This video highlights three ARPA-E-funded approaches to improving the grid's flexibility: topology control software from Boston University that optimizes power flow, gas tube switches from General Electric that provide efficient power conversion, and flow batteries from Harvard University that offer grid-scale energy storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combining model-based and model-free methods for stochastic control of distributed energy resources

Modern distribution systems are experiencing a fast transformation with the growing penetration of distributed energy resources (DERs). Along with the economic and environmental benefits of DERs, challenges arise to address the uncertainties caused by their inherent volatility. If properly coordinated, however, DERs have the potential to provide the controllability that grid operators need. Here, we propose a hierarchical control framework that combines the model-based and model-free methods for stochastic DER control in distribution systems. The upper-level scheduler considers a chance-constrained optimal power flow problem (model-based) that schedules DER setpoints to minimize the operational cost and maintain the operating reserve. The lower-level distributed DER controllers absorb real-time disturbances and uncertainties using the extremum seeking control (model-free) to achieve grid objectives. The combination of model-based and model-free methods allows us to take the advantages of both methods to effectively manage the uncertainty in distribution systems. The proposed work is demonstrated on the IEEE 13-node feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters

This paper investigates operational techniques to achieve seamless (smooth) microgrid (MG) transitions by dispatching a grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control modes during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worth exploring how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. The results show that the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires that the GFM inverter(s) maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-forming control↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗

Distributed optimization and control for autonomous distributed energy resource power dispatch and frequency regulation considering communication failures

Distributed energy resources (DERs) can significantly enhance grid flexibility by supplying power and secondary frequency regulation (SFR) services. Yet, their large number and dispersed nature limit the effectiveness of traditional centralized power dispatch and frequency control schemes, and expose the system to single-point communication failures. This paper presents a unified distributed optimization and control framework for DER power dispatch and SFR provision. A transmission-loss-aware distributed direct current optimal power flow is first formulated to optimize DER power dispatch and reserve scheduling. On top of this, a fully distributed control scheme for DER autonomous SFR provision is developed to allocate automatic generation control signals cost-effectively while ensuring robustness to communication link disruptions. The framework is validated on IEEE 14-bus and 39-bus transmission systems with large-scale distribution feeders using transmission-distribution dynamic co-simulation, demonstrating reliable and autonomous DER power dispatch and SFR provision under diverse operating conditions and communication contingencies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental analysis of spatial correlation effects on capillary trapping of supercritical CO 2 at the intermediate laboratory scale in heterogeneous porous media

Several numerical studies have demonstrated that the heterogeneous nature of typical sedimentary formations can favorably dampen the accumulation of mobile CO 2 phase underneath the caprock. Core flooding experiments have also shown that contrasts in capillary entry pressure can lead to buildup of nonwetting fluid phase (NWP) at interfaces between facies. Explicit representation of geological heterogeneity at the intermediate (cm-to-m) scale is a powerful approach to identify the key mechanisms that control multiphase flow dynamics in porous media. The ability to carefully control flow regime and permeability contrast at a scale that is relevant to CO 2 plume dynamics in saline formations offers valuable information to understand immiscible displacement processes and provides a benchmark for mathematical models. To provide insight into the impact of capillary heterogeneity on flow dynamics and trapping efficiency of supercritical CO 2 under successive drainage and imbibition conditions, we present an experimental investigation conducted in a synthetic sand reservoir. By mimicking the interplay of governing forces at reservoir conditions via application of surrogate fluids, we performed three immiscible displacement experiments to observe the entrapment of NWP in heterogeneous porous media. Capillary trapping performance is evaluated for each scenario through spatial and temporal variations of NWP saturation; for this reason we adopted X-ray attenuation to precisely measure phase saturation throughout the flow domain and apply spatial moment analysis. Furthermore, the sweeping performance of two different permeability fields with comparable variance but distinct spatial correlation was compared against a homogeneous base case with equivalent mean permeability by means of spatial moment analysis.

58 GEOSCIENCES↗

Effectiveness of BaTiO 3 dielectric patches on YBa 2 Cu 3 O 7 thin films for MEM switches

A micro-electro-mechanical (MEM) switch built on a superconducting microstrip filter will be utilized to investigate BaTiO 3 dielectric patches for functional switching points of contact. Actuation voltage resulting from the MEM switch provokes static friction between the bridge membrane and BaTiO 3 insulation layer. Furthermore, the dielectric patch crystal structure and roughness affect the ability of repetitively switching cycles and lifetime. We performed a series of experiments using different deposition methods and RF magnetron sputtering was found to be the best deposition process for the BaTiO 3 layer. The effect examination of surface morphology will be presented using characterization techniques as x-ray diffraction, SEM and AFM for an optimum switching device. The thin film is made of YBa 2 Cu 3 O 7 deposited on LaAlO 3 substrate by pulsed laser deposition. In our work, the dielectric material sputtering pressure is set at 9.5x10 -6 Torr. The argon gas is released through a mass-flow controller to purge the system prior to deposition. RF power is 85 W at a distance of 9 cm. The behavior of Au membranes built on ultimate BaTiO 3 patches will be shown as part of the results. These novel surface patterns will in turn be used in modelling other RF MEM switch devices such as distributed-satellite communication system operating at cryogenic temperatures.

36 MATERIALS SCIENCE↗

Distributed MPC for Efficient Coordination of Storage and Renewable Energy Sources Across Control Areas

In electric power systems, multiple entities are responsible for ensuring an economic and reliable way of delivering power from producers to consumers. With the increase of variable renewable generation it is becoming increasingly important to take advantage of the individual entities' (and their areas') capabilities for balancing variability. Hence, in this paper, we employ and extend the approximate Newton directions method to optimally coordinate control areas leveraging storage available in one area to balance variable resources in another area with only minimal information exchange among the areas. The problem to be decomposed is a model predictive control problem including generation constraints, energy storage constraints, and AC power flow constraints. Singularity issues encountered when formulating the respective Newton-Raphson steps due to intertemporal constraints are addressed and extensions to the original decomposition method are proposed to improve the convergence rate and required communication of the method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active Wake Redirection Control to Improve Energy Yield (Poster)

Wake effects can dramatically reduce the efficiency of waked turbines relative to the unwaked turbines. Wakes can be deflected, or 'redirected,' by applying yaw misalignment to the turbines. Yaw misalignment causes part of the rotor thrust vector to be pointed in the cross-stream direction, deflecting the flow and the wake. Yaw misalignment reduces power production, but the global increase in wind plant power due to decreased wake effect creates a net increase in power production. It is also a fairly simple control idea to implement at existing or new wind plants. We performed high-fidelity computational fluid dynamics simulations of the wake flow of the proposed Fishermen's Atlantic City Windfarm (FACW) that predict that under certain waking conditions, wake redirection can increase plant efficiency by 10%. This means that by applying wake redirection control, for a given watersheet area, a wind plant can either produce more power, or the same amount of power can be produced with a smaller watersheet area. With the power increase may come increased loads, though, due to the yaw misalignment. If misalignment is applied properly, or if layered with individual blade pitch control, though, the load increase can be mitigated. In this talk we will discuss the concept of wake redirection through yaw misalignment and present our CFD results of the FACW project. We will also discuss the implications of wake redirection control on annual energy production, and finally we will discuss plans to implement wake redirection control at FACW when it is operational.

17 WIND ENERGY↗

Generator powered electrically heated diesel particulate filter

A control circuit for a vehicle powertrain includes a switch that selectivity interrupts current flow between a first terminal and a second terminal. A first power source provides power to the first terminal and a second power source provides power to the second terminal and to a heater of a heated diesel particulate filter (DPF). The switch is opened during a DPF regeneration cycle to prevent the first power source from being loaded by the heater while the heater is energized.

42 ENGINEERING↗

Turbulence and Control of Wind Farms

The dynamics of the turbulent atmospheric boundary layer play a fundamental role in wind farm energy production, governing the velocity field that enters the farm as well as the turbulent mixing that regenerates energy for extraction at downstream rows. Understanding the dynamic interactions among turbines, wind farms, and the atmospheric boundary layer can therefore be beneficial in improving the efficiency of wind farm control approaches. Anticipated increases in the sizes of new wind farms to meet renewable energy targets will increase the importance of exploiting this understanding to advance wind farm control capabilities. This review discusses approaches for modeling and estimation of the wind farm flow field that have exploited such knowledge in closed-loop control, to varying degrees. We focus on power tracking as an example application that will be of critical importance as wind farms transition into their anticipated role as major suppliers of electricity. The discussion highlights the benefits of including the dynamics of the flow field in control and points to critical shortcomings of the current approaches.

Automation & Control Systems↗

Investigation of plant control strategies for the supercritical C0{sub 2}Brayton cycle for a sodium-cooled fast reactor using the plant dynamics code.

The development of a control strategy for the supercritical CO{sub 2} (S-CO{sub 2}) Brayton cycle has been extended to the investigation of alternate control strategies for a Sodium-Cooled Fast Reactor (SFR) nuclear power plant incorporating a S-CO{sub 2} Brayton cycle power converter. The SFR assumed is the 400 MWe (1000 MWt) ABR-1000 preconceptual design incorporating metallic fuel. Three alternative idealized schemes for controlling the reactor side of the plant in combination with the existing automatic control strategy for the S-CO{sub 2} Brayton cycle are explored using the ANL Plant Dynamics Code together with the SAS4A/SASSYS-1 Liquid Metal Reactor (LMR) Analysis Code System coupled together using the iterative coupling formulation previously developed and implemented into the Plant Dynamics Code. The first option assumes that the reactor side can be ideally controlled through movement of control rods and changing the speeds of both the primary and intermediate coolant system sodium pumps such that the intermediate sodium flow rate and inlet temperature to the sodium-to-CO{sub 2} heat exchanger (RHX) remain unvarying while the intermediate sodium outlet temperature changes as the load demand from the electric grid changes and the S-CO{sub 2} cycle conditions adjust according to the S-CO{sub 2} cycle control strategy. For this option, the reactor plant follows an assumed change in load demand from 100 to 0 % nominal at 5 % reduction per minute in a suitable fashion. The second option allows the reactor core power and primary and intermediate coolant system sodium pump flow rates to change autonomously in response to the strong reactivity feedbacks of the metallic fueled core and assumed constant pump torques representing unchanging output from the pump electric motors. The plant behavior to the assumed load demand reduction is surprising close to that calculated for the first option. The only negative result observed is a slight increase in the intermediate inlet sodium temperatures by about 10 C. This temperature rise could presumably be precluded or significantly reduced through fine adjustment of the control rods and pump motors. The third option assumes that the reactor core power and primary and intermediate system flow rates are ideally reduced linearly in a programmed fashion that instantaneously matches the prescribed load demand. The calculated behavior of this idealized case reveals a number of difficulties because the control strategy for the S-CO{sub 2} cycle overcools the reactor potentially resulting in the calculation of sodium bulk freezing and the onset of sodium boiling. The results show that autonomous SFR operation may be viable for the particular assumed load change transient and deserves further investigation for other transients and postulated accidents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Decentralized State Estimation and Remedial Control Action for Minimum Wind Curtailment Using Distributed Computing Platform

Intermittency of wind energy poses a great challenge for power system operation and control. Wind curtailment might be necessary at the certain operating condition to keep the line flow within the limit. Remedial Action Scheme (RAS) offers quick control action mechanism to keep reliability and security of the power system operation with high wind energy integration. In this paper, a new RAS is developed to maximize the wind energy integration without compromising the security and reliability of the power system based on specific utility requirements. A new Distributed Linear State Estimation (DLSE) is also developed to provide the fast and accurate input data for the proposed RAS. A distributed computational architecture is designed to guarantee the robustness of the cyber system to support RAS and DLSE implementation. The proposed RAS and DLSE is validated using the modified IEEE-118 Bus system. Simulation results demonstrate the satisfactory performance of the DLSE and the effectiveness of RAS. Real-time cyber-physical testbed has been utilized to validate the cyber-resiliency of the developed RAS against computational node failure.

17 WIND ENERGY↗

Optimization of magnetic amplification by flow constraints in turbulent liquid sodium

Direct measurements of the vector turbulent emf in a driven two-vortex flow of liquid sodium were performed in the Madison Dynamo Experiment [K. Rahbarnia et al., Astrophys. J. 759, 80 (2012)]. The measured turbulent emf is anti-parallel with the mean current and is almost entirely described by an enhanced resistivity, which increases the threshold for a kinematic dynamo. We have demonstrated that this enhanced resistivity can be mitigated by eliminating the largest-scale eddies through the introduction of baffles. By tailoring the flow to reduce large-scale components and control the helical pitch, we have reduced the power required to drive the impellers, doubled the magnetic flux generated by differential rotation, and increased the decay time of externally applied magnetic fields. Despite these improvements, the flows remain sub-critical to the dynamo instability due to the reemergence of turbulent fluctuations at high flow speeds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cyber‐physical system testbed for power system monitoring and wide‐area control verification

The electric power system is intrinsically a cyber‐physical system (CPS) with power flowing inthe physical system and information flowing in the cyber‐network. Testbeds arecrucial for understanding the cyber‐physical interactions and provideenvironments for prototyping novel applications. This study proposes afour‐layer architecture for CPS testbeds with emphases on communication networkemulation and networked physical components. A configurable software‐definednetwork is employed to bridge physical components with wide‐area applicationsfor closed‐loop control. In order to distribute physically coupled devices intomultiple software simulations, this study proposes a data broker setup based ona distributed messaging environment to achieve low‐latency data streaming. Thedecoupled design with data streaming allows for building testbed components asmodules and running them in a distributed manner. Case studies verify the databroker setup for low‐latency sensing and actuation, as well as the communicationemulation setup for the desired network latency. Also illustrated is a replayattack scenario using synchrophasors in the Western Electricity CoordinatingCouncil (WECC) 181‐bus system for demonstrating the closed‐loop cyber‐physicalsimulation capability of the testbed.

Cui, Hantao↗

Heat exchanger temperature response for duty-cycle transients in the NGNP/HTE.

Control system studies were performed for the Next Generation Nuclear Plant (NGNP) interfaced to the High Temperature Electrolysis (HTE) plant. Temperature change and associated thermal stresses are important factors in determining plant lifetime. In the NGNP the design objective of a 40 year lifetime for the Intermediate Heat Exchanger (IHX) in particular is seen as a challenge. A control system was designed to minimize temperature changes in the IHX and more generally at all high-temperature locations in the plant for duty-cycle transients. In the NGNP this includes structures at the reactor outlet and at the inlet to the turbine. This problem was approached by identifying those high-level factors that determine temperature rates of change. First are the set of duty cycle transients over which the control engineer has little control but which none-the-less must be addressed. Second is the partitioning of the temperature response into a quasi-static component and a transient component. These two components are largely independent of each other and when addressed as such greater understanding of temperature change mechanisms and how to deal with them is achieved. Third is the manner in which energy and mass flow rates are managed. Generally one aims for a temperature distribution that minimizes spatial non-uniformity of thermal expansion in a component with time. This is can be achieved by maintaining a fixed spatial temperature distribution in a component during transients. A general rule of thumb for heat exchangers is to maintain flow rate proportional to thermal power. Additionally the product of instantaneous flow rate and heat capacity should be maintained the same on both sides of the heat exchanger. Fourth inherent mechanisms for stable behavior should not be compromised by active controllers that can introduce new feedback paths and potentially create under-damped response. Applications of these principles to the development of a plant control strategy for the reference NGNP/HTE plant can be found in the body of this report. The outcome is an integrated plant/control system design. The following conclusions are drawn from the analysis: (1) The plant load schedule can be managed to maintain near-constant hot side temperatures over the load range in both the nuclear and chemical plant. (2) The reactor open-loop response is inherently stable resulting mainly from a large Doppler temperature coefficient compared to the other reactivity temperature feedbacks. (3) The typical controller used to manage reactor power production to maintain reactor outlet temperature at a setpoint introduces a feedback path that tends to destabilize reactor power production in the NGNP. (4) A primary loop flow controller that forces primary flow to track PCU flow rate is effective in minimizing spatial temperature differentials within the IHX. (5) Inventory control in both the primary and PCU system during ramp load change transients is an effective means of maintaining high NGNP thermal efficiency while at reduced electric load. (6) Turbine bypass control is an effective means for responding to step changes in generator load when equipment capacity limitations prevent inventory control from being effective. (7) Turbine bypass control is effective in limiting PCU shaft over speed for the loss of generator load upset event. (8) The proposed control strategy is effective in limiting time variation of the differential spatial temperature distribution in the IHX during transients. Essentially the IHX can be made to behave in a manner where each point in the IHX experiences approximately the same temperature rate of change during a transient. (9) The stability of the closed-loop Brayton cycle was found to be sensitive to where one operates on the turbo-machine performance maps. There are competing interests: more stable operation means operating on the curves at points that reduce overall cycle efficiency. Future work should address in greater detail elements that came to light in the course of this work. Specifically: (1) A stability analysis should be performed to identify the phenomena that control reactor outlet temperature stability when operating with the Reactor Outlet Temperature Controller. The goal is to identify a better performing controller. (2) Future simulations should be performed with multiple axial nodes. The single axial node model for the core used in this work gives rise to an initial core reactor outlet temperature perturbation that is a numerical artifact. (3) The tradeoffs referred to above regarding the dependence of Brayton cycle stability and efficiency on performance curve characteristics and use need to be better understood. (4) The role of xenon was neglected in this work and needs to be included in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗