A regenerative concept for thermoelectric power generation

Here this paper presents a regenerative concept for thermoelectric (TE) based waste heat recovery systems called thermoelectric generators (TEGs). TEG is usually a modified heat exchanger with the addition of thermoelectric modules (TEMs) to recover waste heat for power generation. To utilize heat from high temperature heat sources, current researches have largely been focused on the development of high temperature TE materials. In this study, we describe a regeneration concept in which a precooler is used to lower the temperature of the hot gas and at the same time regenerate hot air from the cold air supply for Bi 2 Te 3 -based TEGs, avoiding the use of high-temperature thermoelectric materials. It is found that the regenerative TEGs can achieve a similar power output compared with TEGs using high temperature TE materials such as filled-skutterudites (combined filled skutterudites and Bi 2 Te 3 TE materials) through obtaining a higher heat scavenging rate. Thus, the regenerative TEGs also have a similar absolute efficiency, defined according to the total available enthalpy from the hot gas. This could represent a paradigm shift in the TEG research and development, that much lower-cost, reliable, and readily available TE materials and modules can be used for high temperature applications, and will ultimately enable wide spread deployment of TEGs for real world waste heat recovery applications.

42 ENGINEERING↗

Safety research of insulating materials of cable for nuclear power generating station

The polymers PE, EPR, PVC, Neoprene, CSP, CLPE, EP and other similar substances are frequently used as insulation and protective covering for cables used in nuclear power generating stations. In order to test these materials for flame retardation, environmental resistance, and cable specifications, they were given the cable normal test, flame test, chemical tests, and subjected to design analysis and loss of coolant accident tests. Material was collected on spark tests and actual experience standards were established through these contributions and technology was accumulated.

Lee, C. K.↗

Electrical power generation from moderate-temperature radiative thermal sources

Moderate-temperature thermal sources (100° to 400°C) which radiate waste heat are often the by-product of mechanical work, chemical or nuclear reactions, or information processing. We demonstrate conversion of thermal radiation into electrical power using a bipolar grating-coupled complementary metal-oxide-silicon (CMOS) tunnel diode. A two-step photon-assisted tunneling charge pumping mechanism results in separation of charge carriers in pn-junction wells leading to a large open-circuit voltage developed across a load. Electrical power generation from a broadband blackbody thermal source has been experimentally demonstrated with converted power densities of 27 to 61 microwatts per square centimeter for thermal sources between 250° and 400°C. Scalable, efficient conversion of radiated waste heat into electrical power can be used to reduce energy consumption or to power electronics and sensors.

30 DIRECT ENERGY CONVERSION↗

On-Shore Central Hydraulic Power Generation for Wind and Tidal Energy

Tidal energy, offshore wind energy, and onshore wind energy can be converted to electricity at a central ground location by means of converting their respective energies into high-pressure hydraulic flows that are transmitted to a system of generators by high-pressure pipelines. The high-pressure flows are then efficiently converted to electricity by a central power plant, and the low-pressure outlet flow is returned. The Department of Energy (DOE) is presently supporting a project led by Sunlight Photonics to demonstrate a 15 kW tidal hydraulic power generation system in the laboratory and possibly later submerged in the ocean. All gears and submerged electronics are completely eliminated. A second portion of this DOE project involves sizing and costing a 15 MW tidal energy system for a commercial tidal energy plant. For this task, Atlantis Resources Corporation s 18-m diameter demonstrated tidal blades are rated to operate in a nominal 2.6 m/sec tidal flow to produce approximately one MW per set of tidal blades. Fifteen units would be submerged in a deep tidal area, such as in Maine s Western Passage. All would be connected to a high-pressure (20 MPa, 2900 psi) line that is 35 cm ID. The high-pressure HEPG fluid flow is transported 500-m to on-shore hydraulic generators. HEPG is an environmentally-friendly, biodegradable, watermiscible fluid. Hydraulic adaptations to ORPC s cross-flow turbines are also discussed. For 15 MW of wind energy that is onshore or offshore, a gearless, high efficiency, radial piston pump can replace each set of top-mounted gear-generators. The fluid is then pumped to a central, easily serviceable generator location. Total hydraulic/electrical efficiency is 0.81 at full rated wind or tidal velocities and increases to 0.86 at 1/3 rated velocities.

wind energy↗

On-Shore Central Hydraulic Power Generation for Wind and Tidal Energy

Tidal energy, offshore wind energy, and onshore wind energy can be converted to electricity at a central ground location by means of converting their respective energies into high-pressure hydraulic flows that are transmitted to a system of generators by high-pressure pipelines. The high-pressure flows are then efficiently converted to electricity by a central power plant, and the low-pressure outlet flow is returned. The Department of Energy (DOE) is presently supporting a project led by Sunlight Photonics to demonstrate a 15 kilowatt tidal hydraulic power generation system in the laboratory and possibly later submerged in the ocean. All gears and submerged electronics are completely eliminated.A second portion of this DOE project involves sizing and costing a 15 megawatt tidal energy system for a commercial tidal energy plant. For this task, Atlantis Resources Corporation's 18-m diameter demonstrated tidal blades are rated to operate in a nominal 2.6 m/sec tidal flow to produce approximately one megawatt per set of tidal blades. Fifteen units would be submerged in a deep tidal area, such as in Maine's Western Passage. All would be connected to a high-pressure (20 megapascals, 2900 pounds per square inch) line that is 35 cm ID. The high-pressure HEPG fluid flow is transported 500-m to on-shore hydraulic generators. HEPG is an environmentally-friendly, biodegradable, water-miscible fluid. Hydraulic adaptations to ORPC's cross-flow turbines are also discussed.For 15 megawatt of wind energy that is onshore or offshore, a gearless, high efficiency, radial piston pump can replace each set of top-mounted gear-generators. The fluid is then pumped to a central, easily serviceable generator location. Total hydraulic/electrical efficiency is 0.81 at full rated wind or tidal velocities and increases to 0.86 at 1/3 rated velocities.

wind energy↗

Understanding Diurnal Patterns in Wind Power Generation Data

Integrating wind energy on the power grid is a challenging task given the intermittent nature of these resources. When the percentage of wind energy was small, control room operators did not have a major problem in scheduling wind resources. However, as this percentage has increased, it is clear that the operators will need more accurate forecasts, as well as any additional information they can exploit, to make better-informed scheduling decisions. In this paper, we investigate diurnal patterns observed in wind-power time series data. Using actual wind generation data from two sites, we try to identify these patterns, understand them better, and determine if it is possible to use weather conditions in the vicinity of the wind farms to predict the pattern for a day. Such analysis could provide insights useful in scheduling wind resources on days with inaccurate forecasts.

17 WIND ENERGY↗

Low-Cost High-Concentration Photovoltaic Systems for Utility Power Generation

Under DOE's Technology Pathway Partnership (TPP) program, Amonix, Inc. developed a new generation of high-concentration photovoltaic systems using multijunction technology and established the manufacturing capacity needed to supply multi-megawatt power plants built using the new Amonix 7700-series solar energy systems. For this effort, Amonix Collaborated with a variety of suppliers and partners to complete project tasks. Subcontractors included: Evonik/Cyro; Hitek; the National Renewable Energy Laboratory (NREL); Raytech; Spectrolab; UL; University of Nevada, Las Vegas; and TUV Rheinland PTL. The Amonix TPP tasks included: Task 1: Multijunction Cell Optimization for Field Operation, Task 2: Fresnel Lens R&D, Task 3: Cell Package Design & Production, Task 4: Standards Compliance and Reliability Testing, Task 5: Receiver Plate Production, Task 6: MegaModule Performance, Task 7: MegaModule Cost Reduction, Task 8: Factory Setup and MegaModule Production, Task 9: Tracker and Tracking Controller, Task 10: Installation and Balance of System (BOS), Task 11: Field Testing, and Task 12: Solar Advisor Modeling and Market Analysis. Amonix's TPP addressed nearly the complete PV value chain from epitaxial layer design and wafer processing through system design, manufacturing, deployment and O&M. Amonix has made progress toward achieving these reduced costs through the development of its 28%+ efficient MegaModule, reduced manufacturing and installation cost through design for manufacturing and assembly, automated manufacturing processes, and reduced O&M costs. Program highlights include: (1) Optimized multijunction cell and cell package design to improve performance by > 10%; (2) Updated lens design provided 7% increased performance and higher concentration; (3) 28.7% DC STC MegaModule efficiency achieved in Phase II exceeded Phase III performance goal; (4) New 16' focal length MegaModule achieved target materials and manufacturing cost reduction; (5) Designed and placed into production 25 MW/yr manufacturing capacity for complete MegaModules, including cell packages, receiver plates, and structures with lenses; (6) Designed and deployed Amonix 7700 series systems rated at 63 kW PTC ac and higher. Based on an LCOE assessment using NREL's Solar Advisor Model, Amonix met DOE's LCOE targets: Amonix 2011 LCOE 12.8 cents/kWh (2010 DOE goal 10-15); 2015 LCOE 6.4 cents/kWh (2015 goal 5-7) Amonix and TPP participants would like to thank the U.S. Department of Energy Solar Energy Technology Program for funding received under this program through Agreement No. DE-FC36-07GO17042.

14 SOLAR ENERGY↗

Analytical investigation of thermal barrier coatings for advanced power generation combustion turbines

An analytical evaluation was conducted to determine quantitatively the improvement potential in cycle efficiency and cost of electricity made possible by the introduction of thermal barrier coatings to power generation combustion turbine systems. The thermal barrier system, a metallic bond coat and yttria stabilized zirconia outer layer applied by plasma spray techniques, acts as a heat insulator to provide substantial metal temperature reductions below that of the exposed thermal barrier surface. The study results show the thermal barrier to be a potentially attractive means for improving performance and reducing cost of electricity for the simple, recuperated, and combined cycles evaluated.

Amos, D. J.↗

High-Voltage Pulsed Power Generator for Beam Injection Systems

Beam injection systems in hadron colliders require kickers generating ±50 kV peak voltages into a 50 Ω impedance, with peak currents of 1000 A and sub-10 ns rise and fall times. This paper presents a novel high-voltage pulse power generator utilizing a distributed pulser architecture. It combines gallium nitride (GaN) transistors in a Marx topology with an inductive adder, achieving nanosecond-scale switching speeds and high-power efficiency. Compared to other solutions such as based on MOSFETs or fast ionization dynistors, our development offers superior peak and average power performance, reduced system complexity, and enhanced reliability, marking a significant step forward in high-voltage pulse generation for accelerator applications.

Smirnov, Alexander (ORCID:0000000280631691)↗

Inexpensive and Sustainable Anti-Corrosion Coating for Power Generation Applications

The goal of the project was to achieve lab-scale demonstration of a corrosion prevention technology, which will facilitate the capture of CO 2 from coal and natural gas fired power generation by reducing the cost of construction materials and maintenance. The project built on technology previously developed by LumiShield to address more broad-based corrosion issues and the results shown will be applicable to a wide range of markets requiring cost effective corrosion resistant coatings. That technology developed is a base layer to improve the performance and reduce the cost of organic anti-corrosion coatings. The impact of those changes on overall plant economics were demonstrated with the help of engineers at AECOM through an initial cost-benefit-analysis at the end of BP1 which will be updated at the end of BP2.

01 COAL, LIGNITE, AND PEAT↗

Preliminary Technical Environmental Health and Safety (EH&S) Assessment – Pilot Test of Novel Electrochemical Membrane System for Carbon Dioxide Capture and Power Generation

A preliminary Environmental Health and Safety (EH&S) assessment of the Electrochemical Membrane (ECM)-based CO2 capture system was conducted. This topical report presents the results of the EH&S assessment. The study was based on the carbon capture system size suitable for a reference 550 MW Pulverized Coal (PC) power plant. The ECM technology is derived from commercially available inorganic membranes; the same used in FuelCell Energy’s commercial fuel cell power plants and sold under the trade name SureSource (previously Direct FuelCell®). The ECM stacks are utilized in the Combined Electric Power (generation) And Carbon dioxide Separation (CEPACS) systems which can be deployed as add-ons to conventional power plants (Pulverized Coal, Combined Cycle, etc.) or industrial facilities to simultaneously produce power while capturing >90% of the CO2 from the host plant flue gas. The CEPACS system process description and review of process, ancillary and incidental gaseous (or air) and liquid (or water) emissions (discharge) as well as the solid waste are included in this report. The report also discusses the related handling requirements and properties of process discharge streams/waste, and the relevant regulatory requirements.

20 FOSSIL-FUELED POWER PLANTS↗

Transition to High-Hydrogen Fueled Advanced Gas Turbine Engines for Land-Based Power Generation and Industrial Applications

Invited lecture presented as part of the 2023 University of Central Florida - Mechanical and Aerospace Engineering Seminar Series. These slides discuss the role of multi-sourced hydrogen for electrical power generation. Particular focus is given to the combustion of hydrogen for the purpose of chemical to thermal energy. Pressure gain combustion is given as an example technology that could leverage hydrogen as a fuel source ultimately leading to higher rates of energy conversion (chemical to electrical) resulting in greater energy security and reduced cost of electricity.

advanced gas turbines↗

A Survey on Next-generation Power Grid Data Architecture

The operation and control of power grids will increasingly rely on data. A high-speed, reliable, flexible and secure data architecture is the prerequisite of the next-generation power grid. This paper summarizes the challenges in collecting and utilizing power grid data, and then provides reference data architecture for future power grids. Based on the data architecture deployment, related research on data architecture is reviewed and summarized in several categories including data measurement/actuation, data transmission, data service layer, data utilization, as well as two cross-cutting issues, interoperability and cyber security. Research gaps and future work are also presented.

You, Shutang↗

Comprehensive energy balance analysis of photon-enhanced thermionic power generation considering concentrated solar absorption distribution

The present article reports a comprehensive energy balance analysis of a photon-enhanced thermionic emission (PETE) device when it is used for concentrated solar power (CSP) generation. To this end, we consider a realistic PETE device composed of a boron-doped silicon emitter on glass and a phosphorus-doped diamond collector on tungsten separated by the interelectrode vacuum gap. Here, depth-dependent spectral solar absorption and its photovoltaic and photothermal energy conversion processes are rigorously calculated to predict the PETE power output and energy conversion efficiency. Our calculation predicts that when optimized, the power output of the considered PETE device can reach 1.6 W/cm 2 with the energy conversion efficiency of ~ 18% for 100× solar concentration, which is substantially lower than those predicted in previous works under ideal conditions. In addition, the photon-enhancement ratio is lower than 10 and decreases with the increasing solar concentration due to the photothermal heating of the emitter assembly, suggesting that PETE should be more suitable for lowto- medium CSP below ~ 100× concentration. These observations signify the importance of a rigorous energy balance analysis based on spectral and spatial solar absorption distribution for the accurate prediction of PETE power generation.

14 SOLAR ENERGY↗

Flexible Technoeconomic Analysis Tools for Evaluating Emerging Power Generation Technologies in Hourly Electricity Markets using IDAES and Pyomo

Conference presentation leveraging the recently developed “price-taker class”. We use the tool to develop and showcase workflows that enable rapid technology evaluation for power generation technologies. This work shows a reimplementation of previous results that were conducted outside the price-taker class framework, indicating this workflow is indeed streamlining emerging technology analysis.

Laky, Daniel↗

The Tethered Balloon Current Generator - A space shuttle-tethered subsatellite for plasma studies and power generation

The objectives of the Tethered Balloon Current Generator experiment are to: (1) generate relatively large regions of thermalized, field-aligned currents, (2) produce controlled-amplitude Alfven waves, (3) study current-driven electrostatic plasma instabilities, and (4) generate substantial amounts of power or propulsion through the MHD interaction. A large balloon (a diameter of about 30 m) will be deployed with a conducting surface above the space shuttle at a distance of about 10 km. For a generally eastward directed orbit at an altitude near 400 km, the balloon, connected to the shuttle by a conducting wire, will be positive with respect to the shuttle, enabling it to collect electrons. At the same time, the shuttle will collect positive ions and, upon command, emit an electron beam to vary current flow in the system.

Williamson, P. R.↗