Study of alternative probe technologies

A number of implied technologies for a deep probe mission was examined; i.e., one that would provide the capability to scientifically examine planetary atmospheres at the 1000 bar level. Conditions imposed by current Jupiter, Saturn, and Uranus atmospheric models were considered. The major thrust of the measurements was to determine lower atmosphere composition, even to trace constituents of one part per billion. Two types of instruments having the necessary accuracy to meet the science objectives were considered and integrated into a deep probe configuration. One deep probe option that resulted was identified as a Minimum Technology Development approach. The significant feature of this option is that only three technology developments are required to enable the mission, i.e., (1) science instrument development, (2) advanced data processing, and (3) external high pressure/thermal insulation. It is concluded that a probe designed for a Jupiter mission could, with minor changes, be used for a Saturn or Uranus mission.

Source record↗

Jovian probe wake flowfield

The base heating problem in the Jovian probe was examined. The entire wake flowfield is defined to calculate the radiative heating to the base region of the Jovian probe. Engineering tools for calculating the probe's wake flowfield are developed. The near and far viscous and inviscid flowfields for three entry conditions are calculated. The flowfields include pressure, temperature, and species concentration for radiation analysis. A mathematical model used in the calculations is described. The results obtained indicate that temperatures in the Jovian probe range from 4,000 to 10,00 K and pressures range from 10 to 1,000 times the free stream value.

Engel, C. D.↗

Proposed methods for the reconstruction of the Pioneer/Venus probe entry trajectories

In connection with the Pioneer Venus Project, an orbiter and an array of atmospheric probes are sent to Venus in separate launches during 1978. The four probes, which are transported to the planet on an instrumented Bus are released approximately 20 days prior to encounters. There are three identical small probes and a large probe. Each is designed to make in-situ atmospheric measurements. One of the principal scientific objectives of the Pioneer Venus (P/V) multiprobe mission is the determination of the structure and composition of the Venusian atmosphere down to the planet surface. To enhance the science return it is of paramount importance to be able to accurately determine the spacecraft entry trajectories. In addition to the in-situ spacecraft measurements, earth-based Doppler data are available. The process felt to be most applicable for the P/V multiprobe entry trajectory reconstruction is considered, with emphasis placed on the highly dynamic upper entry segment of the trajectory.

Findlay, J. T.↗

Geological assessment probe

A probe is described which can be installed in a side hole that extends from a bore hole in the Earth, to assess the permeability of the strata surrounding the borehole. The probe is elongated and has a plurality of seals spaced therealong and sealed to the walls of the side hole to form a plurality of chambers sealed from one another. A tracer fluid injector on the probe can inject a tracer fluid into one of the chambers, while a tracer fluid detector located in another chamber can detect the tracer fluid, to thereby sense the permeability of the strata surrounding the side hole. The probe can include a train of modules, with each module having an inflatable packer which is inflated by the difference between the borehole pressure and the strata pressure.

Collins, E. R.↗

Calorimeter probes for measuring high thermal flux

The paper describes expendable, slug-type calorimeter probes developed for measuring high heat-flux levels of 10-30 kW/sq cm in electric-arc jet facilities. The probes are constructed with thin tungsten caps mounted on Teflon bodies; the temperature of the back surface of the tungsten cap is measured, and its rate of change gives the steady-state, absorbed heat flux as the calorimeter probe heats to destruction when inserted into the arc jet. It is concluded that the simple construction of these probes allows them to be expendable and heated to destruction to obtain a measurable temperature slope at high heating rates.

Russell, L. D.↗

Performance of entry heat shields on Pioneer Venus probes

The Pioneer Venus probes approached Venus with high relative velocity. As they entered the atmosphere, they were rapidly decelerated by aerodynamic drag, and a great deal of heat was generated. To protect the probe structure and the scientific instruments, a carbon phenolic heat shield was placed on the front of the probes. Because the design of heat shields for planetary entry is a developing technology, thermocouples were placed in the heat shields so that actual and predicted heat shield performance could be compared. The function of the heat shield is discussed, the probe environments during entry into the Venusian atmosphere are described, and some results from the heat shield experiment are presented. It was found that for the most part, the heat shields performed better than expected.

Pitts, W. C.↗

Unsteady aerodynamics and motions of the Pioneer Venus probes

Helicopter drop tests were made of models of the Pioneer Venus probe descent configurations to characterize their unsteady forces and angular dynamics in equilibrium descent. The axial and normal forces were found to be unsteady in magnitude by about 10 and 5% of the mean axial force, respectively. A cycle of the axial variation takes place in flight distances of from 15 to 40 diameters. The unsteadiness almost certainly is associated with the wake. Angular motions which do not converge to zero angle of attack even in very long duration descent are excited by the unsteady pitching moments. The nearly spherical large probe model was aerodynamically more unsteady than the round-nosed conical small probe model. Data returned from Venus by the Pioneer Venus probes show unsteady axial forces and angular motions similar to those seen in the drop tests.

Seiff, A.↗

Measurement of very large flow angles with non-nulling seven-hole probes

This paper describes a method for measuring local direction and total and static pressures of a flow by means of a fixed probe, provided that the local air flow does not make an angle of more than 80 degrees with the axis of the probe. The probe is easily manufactured from standard-sized tubing materials. The power series calibration method used with the probe results in explicit polynomial expressions for the desired aerodynamic properties. The calibration method is easily programmed on a data acquisition system. This paper includes an example of a complete incompressible calibration.

Gallington, R. W.↗

Temperature-Averaging Thermal Probe

Temperature-averaging thermal probe measures long-term temperature fluctuations in fluid environment. Consists of temperature probe embedded inside thermally massive material. Probe measurements used to estimate powerplant heating and cooling loads, map temperature profiles, and calibrate more-sensitive temperature probes.

Kalil, L. F.↗

Temperature structure in the lower atmosphere of Venus - New results derived from Pioneer Venus entry probe measurements

The Pioneer Venus Small-Probe Net Flux Radiometer temperature sensor and its calibration, the thermal model of the sensor head, the procedure for deriving atmospheric temperature from the sensor temperatures, and the new temperature results for each entry probe are reported. The new results are compared with those of the Small-Probe Atmospheric Structure experiment and with simple models of diurnal and latitudinal temperature contrasts. A dynamical inconsistency between these results and low-latitude measurements by the Sounder probe is described, and possible ways to resolve it are considered.

Sromovsky, L. A.↗

A fast-response aspirating probe for measurements of total temperature and pressure in transonic cryogenic wind tunnel

A newly developed, 3-mm-diam, dual hot-wire aspirating probe was used to measure the time-resolved stagnation temperature and pressure in a transonic cryogenic wind tunnel. The probe consists of two coplanar constant temperature hot wires at different overheat ratios operating in a 1.5-mm-diam channel with a choked exit. Thus, the constant Mach number flow by the wires is influenced only by free-stream stagnation temperature and pressure. Diffusion of the free-stream Mach number to a lower value in the channel reduces the dynamic drag on the hot-wire. Frequency response of the present design is dc to 20 kHz. The probe was used to measure the unsteady wake shed from an oscillating airfoil tested in the 0.3-m Transonic Cryogenic Tunnel at NASA-Langley Research Center. The hot-wire lasted for more than ten hours before breaking, proving the ruggedness of the probe and the usefulness of the technique in a high dynamic pressure, transonic cryogenic wind tunnel. Typical data obtained from the experiment are presented after reduction to stagnation pressure and temperature.

Ng, W.-F.↗

Responses of a hot film and a pressure probe to acoustic excitation in mean flow

The responses of a hot film sensor and a pressure probe to acoustic excitation in steady flow up to a Mach number of 0.5 were measured and compared with the responses of a microphone, flush mounted in the wall of the flow duct. When compared in terms of fluctuating pressure, the response of the pressure probe was less than that of the wall microphone by about 2.1 dB or less at the 0.5 Mach number, while the response of the ho film probe was as much as 6.0 dB above that of the wall sensor, at the Mach numbers 0.3 and 0.5. In terms of fluctuating Reynolds number, the response of the hot film probe was greater than that of the wall-mounted sensor by at most 5.0 dB at the same Mach numbers. Removing the response contribution from fluctuating temperature in the hot film mathematical model improved the agreement between the two transducer responses for both comparisons.

Jones, M. G.↗

Wind measurements by electromagnetic probes

The emerging technology of electromagnetic probing of the atmosphere to measure winds used in a space vehicle ascent winds load calculations is presented. The frequency range, altitude, and resolution for the following probes are presented: lidars, microwave radars, and clear-air Doppler radars (popularly known as wind profilers). The electromagnetic probing of the atmosphere by clear-air radars and lasers is the new technology to supplement balloon-borne wind sensors used to determine ascent wind loads of space vehicles. The electromagnetic probes measure the wind velocity using the Doppler effect. This is the radar technology used in MSFC's Radar Wind Profiler, and is similar to the technology used in conventional Doppler systems except that the frequency is generally lower, antenna is bigger, and dwell time much longer. Designed for unattended and automated instrumentation in providing measurements of the wind in the troposphere, the profiler employs Doppler radar technology and is currently being put in operation at NASA Kennedy Space Center, Florida.

Susko, Michael↗

A Saturn atmospheric probe - A proposed augmentation to the Cassini mission

The Saturn probe augmentation of the Cassini mission is studied with particular attention given to the scientific rationale for such an augmentation and any associated issues of technical feasibility, system requirements, performance penalties, and costs. A minimal science complement probe, which concentrates only on atmospheric composition and structure with a total mass requirement of slightly less than 200 kg, is described as well as a full science complement probe with a total mass requirement of about 240 kg. It is noted that either of these Saturn probe configurations can be added to the currently planned mission within the launch performance limitations of the Titan 34D7/Centaur G(prime) launch vehicle.

Swenson, Byron L.↗

Calibration of seven-hole pressure probes for use in fluid flows with large angularity

Described here is the calibration of a non-nulling, conical, seven-hole pressure probe over a large range of flow onset angles. The calibration procedure is based on the use of differential pressures to determine the three components of velocity. The method allows determination of the flow angle to within 0.5 deg and velocity magnitude to approximately 1.0 percent. Also included is an examination of the factors which limit the use of the probe, a description of the measurement chain, an error analysis, and a typical experimental result. In addition, a new general analytical model of pressure probe behavior is described and the validity of the model is demonstrated by comparing it with experimentally measured calibration data for a three-hole yaw meter and a seven-hole probe.

Zilliac, Gregory G.↗

Laser diffraction particle sizing: Instrument probe volume relocation and elongation

The effective probe volume of laser diffraction particle sizing instruments depends on many instrument parameters. In particular the probe volume axial boundaries and its location along laser beam are essentially defined by the onset of a vignetting effect where light scattered at large angles from small particles misses the transform lens. This vignetting effect results in a probe volume that must be inconveniently close to the lens in order to detect smaller diameter particles (less than 100 micrometers). With the addition of an appropriately designed Keplerian telescope, the probe volume may be relocated and elongated. The theory of operation of this supplemental optical system is described. Design considerations for these supplemental optical systems are described, including recommendations for lens specifications, assembly and use. An image transfer system is described which has been designed for use on a Malvern 2600HSD instrument. Experimental validation of this image transfer system is described.

Anderson, Robert C.↗

Investigation of the arcjet plume near field using electrostatic probes

The near field plum of a 1 kW class arcjet thruster was investigated using electrostatic probes of various geometries. The electron number densities and temperatures were determined in a simulated hydrazine plume at axial distances between 3 cm (1.2 in) and 15 cm (5.9 in) and radial distances extending to 10 cm (3.9 in) off centerline. Values of electron number densities obtained using cylindrical and spherical probes of different geometries agreed very well. The electron density on centerline followed a source flow approximation for axial distances as near as 3 cm (1.2 in) from the nozzle exit plane. The model agreed well with previously obtained data in the far field. The effects of propellant mass flow rate and input power level were also studied. Cylindrical probes were used to obtain ion streamlines by changing the probe orientation with respect to the flow. The effects of electrical configuration on the plasma characteristics of the plume were also investigated by using a segmented anode/nozzle thruster. The results showed that the electrical configuration in the nozzle affected the distribution of electrons in the plume.