Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIANT HEATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Nulling device for detection of trace gases by NDIR absorption

A nondispersive gas analyzing apparatus is described having a first chamber for containing a first gas, the density of which is determined. A source of radiant energy is provided for passing radiant energy through the first chamber. Modulation means are provided for modulating the radiant energy passing through the first chamber by modulating the volume of the chamber at the acoustic resonance frequency of the first gas and the chamber. Signal generating means, including a second chamber for containing a gas which is heated by radiant energy emerging from the first chamber and a microphonic means responsive to the resulting pressurization in the second chamber, is provided for generating a signal, having a frequency and amplitude corresponding to the modulation of the radiant energy in the first chamber.

Dimeff, J.↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spectroscopic and Photometric Monitoring of a Poorly Known Highly Luminous OH/IR Star: IRAS 18278+0931

We present the time-dependent properties of a poorly known OH/IR star, IRAS 18278+0931 (hereafter IRAS 18+09), toward the Ophiuchus constellation. We have carried out long-term optical/near-infrared photometric and spectroscopic observations to study the object. From optical R- and I-band light curves, the period of IRAS 18+09 is estimated to be 575 ± 30 days and the variability amplitudes range from ΔR ∼ 4.0 mag to ΔI ∼ 3.5 mag. From the standard period–luminosity relations, the distance (D) to the object, 4.0 ± 1.3 kpc, is estimated. Applying this distance in the radiative transfer model, the spectral energy distribution is constructed from multiwavelength photometric and IRAS-LRS spectral data, which provide the luminosity, optical depth, and gas mass-loss rate of the object to be 9600 ± 500 L {sub ⊙}, 9.1 ± 0.6 at 0.55 μm, and 1.0 × 10{sup −6} M {sub ⊙} yr{sup −1}, respectively. The current mass of the object is inferred to be in the range 1.0−1.5 M {sub ⊙} assuming solar metallicity. Notably, the temporal variation of atomic and molecular features (e.g., TiO, Na i, Ca i, CO, H{sub 2}O) over the pulsation cycle of the OH/IR star illustrates the sensitivity of the spectral features to the dynamical atmosphere as observed in pulsating AGB stars.

36 MATERIALS SCIENCE↗

The Anatomy of an Unusual Edge-on Protoplanetary Disk. I. Dust Settling in a Cold Disk

As the earliest stage of planet formation, massive, optically thick, and gas-rich protoplanetary disks provide key insights into the physics of star and planet formation. When viewed edge-on, high-resolution images offer a unique opportunity to study both the radial and vertical structures of these disks and relate this to vertical settling, radial drift, grain growth, and changes in the midplane temperatures. In this work, we present multi-epoch Hubble Space Telescope and Keck scattered light images, and an Atacama Large Millimeter/submillimeter Array 1.3 mm continuum map for the remarkably flat edge-on protoplanetary disk SSTC2DJ163131.2–242627, a young solar-type star in ρ Ophiuchus. We model the 0.8 μm and 1.3 mm images in separate Markov Chain Monte Carlo (MCMC) runs to investigate the geometry and dust properties of the disk using the MCFOST radiative transfer code. In scattered light, we are sensitive to the smaller dust grains in the surface layers of the disk, while the submillimeter dust continuum observations probe larger grains closer to the disk midplane. An MCMC run combining both data sets using a covariance-based log-likelihood estimation was marginally successful, implying insufficient complexity in our disk model. The disk is well characterized by a flared disk model with an exponentially tapered outer edge viewed nearly edge-on, though some degree of dust settling is required to reproduce the vertically thin profile and lack of apparent flaring. A colder than expected disk midplane, evidence for dust settling, and residual radial substructures all point to a more complex radial density profile to be probed with future, higher-resolution observations.

47 OTHER INSTRUMENTATION↗

A Detailed Characterization of HR 8799's Debris Disk with ALMA in Band 7

The exoplanetary system of HR 8799 is one of the rare systems in which multiple planets have been directly imaged. Its architecture is strikingly similar to that of the solar system, with the four imaged giant planets surrounding a warm dust belt analogous to the Asteroid Belt, and themselves being surrounded by a cold dust belt analog to the Kuiper Belt. Previous observations of this cold belt with ALMA in Band 6 (1.3 mm) revealed its inner edge, but analyses of the data differ on its precise location. It was therefore unclear whether or not the outermost planet HR 8799 b was dynamically sculpting it. We present here new ALMA observations of this debris disk in Band 7 (340 GHz, 880 μm). These are the most detailed observations of this disk obtained so far, with a resolution of 1″ (40 au) and sensitivity of 9.8 μJy beam{sup −1}, which allowed us to recover the disk structure with high confidence. In order to constrain the disk morphology, we fit its emission using radiative transfer models combined with a Markov Chain Monte Carlo procedure. We find that this disk cannot be adequately represented by a single power law with sharp edges. It exhibits a smoothly rising inner edge and smoothly falling outer edge, with a peak in between, as expected from a disk that contains a high-eccentricity component, hence confirming previous findings. Whether this excited population and inner edge shape stem from the presence of an additional planet remains, however, an open question.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Lattice Boltzmann Scheme for Polarized Radiative Transfer in Planetary Atmospheres

Quantitative calculation of reflected polarized light from planets is of great significance to interpret the polarimetric observations of planetary atmospheres. In this work, we propose a lattice Boltzmann (LB) scheme for polarized radiative transfer in planetary atmospheres. The LB scheme obtains the Stokes vector through the vector LB equation performing simple collision and streaming processes. The vector radiative transfer equation is rigorously derived from the vector LB equation via the Maxwell iteration technique. Polarized radiative transfer of a single point on the planetary surface with Rayleigh and Mie scattering atmospheres are first accurately solved by our LB scheme. Afterward, we systematically investigate the disk-integrated polarization of finite and semi-infinite, conservative and nonconservative Rayleigh scattering planetary atmospheres. The disk-integrated phase curves of the Stokes parameters and degree of polarization and spherical and geometric albedos are produced, which are in good agreement with the benchmark results for different cases. The numerical results indicate that our LB scheme is efficient and accurate for polarized radiative transfer in planetary atmospheres. Our LB scheme is expected to provide a competitive numerical tool to interpret the polarimetric observations of planetary atmospheres.

47 OTHER INSTRUMENTATION↗

Observational Signatures of Planets in Protoplanetary Disks: Temperature Structures in Spiral Arms

High-resolution imaging of protoplanetary disks has unveiled a rich diversity of spiral structure, some of which may arise from disk-planet interaction. Using 3D hydrodynamics with β cooling to a vertically stratified background, as well as radiative-transfer modeling, we investigate the temperature rise in planet-driven spirals. In rapidly cooling disks, the temperature rise is dominated by a contribution from stellar irradiation, 0.3%–3% inside the planet radius but always < 0.5% outside. When cooling time equals or exceeds dynamical time, however, this is overwhelmed by hydrodynamic PdV work, which introduces a ~10%–20% perturbation within a factor of ~2 from the planet’s orbital radius. We devise an empirical fit of the spiral amplitude Δ(T)=(M{sub p}/M{sub th}){sup c}(f{sub PdV}e{sup -t{sub a}{sub r}{sub m}/t{sub c}}+f{sub rad}) to take into account both effects. Where cooling is slow, we find also that temperature perturbations from buoyancy spirals—a strictly 3D, nonisothermal phenomenon—become nearly as strong as those from Lindblad spirals, which are amenable to 2D and isothermal studies. Our findings may help explain observed thermal features in disks like TW Hydrae and CQ Tauri, and underscore that 3D effects have a qualitatively important effect on disk structure.

42 ENGINEERING↗

Thermal design and performance of the Viking balloon-launched decelerator test vehicles

The thermal design and performance of the test vehicles used for the flight-qualification of the Viking parachute system are described. The desired range of test conditions was provided by a subsonic drop from a balloon altitude of 90,000 feet, and rocket-powered transonic and supersonic flights initiated at balloon altitudes of 120,000 feet. Unusual aspects of the thermal design approach included the application of techniques developed in support of planetary programs to the thermal analysis of balloon payloads and the use of ground firing data to establish realistic upper bounds for radiant plume heating during flight. The adequacy of thermal design is verified by flight data.

Buna, T.↗

Ground-based PIV and numerical flow visualization results from the surface tension driven convection experiment

The Surface Tension Driven Convection Experiment (STDCE) is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the United States Microgravity Laboratory-1 (USML-1) Spacelab mission planned for June, 1992. One of the components of data collected during the experiment is a video record of the flow field. This qualitative data is then quantified using an all electric, two dimensional Particle Image Velocimetry (PIV) technique called Particle Displacement Tracking (PDT), which uses a simple space domain particle tracking algorithm. Results using the ground based STDCE hardware, with a radiant flux heating mode, and the PDT system are compared to numerical solutions obtained by solving the axisymmetric Navier Stokes equations with a deformable free surface. The PDT technique is successful in producing a velocity vector field and corresponding stream function from the raw video data which satisfactorily represents the physical flow. A numerical program is used to compute the velocity field and corresponding stream function under identical conditions. Both the PDT system and numerical results were compared to a streak photograph, used as a benchmark, with good correlation.

Pline, Alexander D.↗

Ground-based PIV and numerical flow visualization results from the Surface Tension Driven Convection Experiment

The Surface Tension Driven Convection Experiment (STDCE) is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the United States Microgravity Laboratory-1 (USML-1) Spacelab mission planned for June, 1992. One of the components of data collected during the experiment is a video record of the flow field. This qualitative data is then quantified using an all electric, two dimensional Particle Image Velocimetry (PIV) technique called Particle Displacement Tracking (PDT), which uses a simple space domain particle tracking algorithm. Results using the ground based STDCE hardware, with a radiant flux heating mode, and the PDT system are compared to numerical solutions obtained by solving the axisymmetric Navier Stokes equations with a deformable free surface. The PDT technique is successful in producing a velocity vector field and corresponding stream function from the raw video data which satisfactorily represents the physical flow. A numerical program is used to compute the velocity field and corresponding stream function under identical conditions. Both the PDT system and numerical results were compared to a streak photograph, used as a benchmark, with good correlation.

Pline, Alexander D.↗

Aerothermal and structural performance of a cobalt-base superalloy thermal protection system at Mach 6.6

A flightweight, metallic thermal protection system (TPS) applicable to reentry and hypersonic vehicles was subjected to multiple cycles of both radiant and aerothermal heating in order to evaluate its aerothermal performance and structural integrity. Good structural integrity and thermal performance were demonstrated by the TPS under both a radiant and aerothermal heating environment typical of a shuttle entry. The shingle-slip joints effectively allowed for thermal expansion of the panel without allowing any appreciable hot gas flow into the TPS cavity. The TPS also demonstrated good structural ruggedness.

Sawyer, J. W.↗