Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Nuclear Science Symposium, 19th, and Nuclear Power Systems Symposium, 4th, Miami, Fla., December 6-8, 1972, Proceedings.

Major topics covered include radiation monitoring instrumentation, nuclear circuits and systems, biomedical applications of nuclear radiation in diagnosis and therapy, plasma research for fusion power, reactor control and instrumentation, nuclear power standards, and applications of digital computers in nuclear power plants. Systems and devices for space applications are described, including the Apollo alpha spectrometer, a position sensitive detection system for UV and X-ray photons, a 4500-volt electron multiplier bias supply for satellite use, spark chamber systems, proportional counters, and other devices. Individual items are announced in this issue.

Source record↗

YBa2Cu3O(7-delta)/Au/Nb sandwich geometry SNS weak links on c-axis oriented YBa2Cu3O(7-delta)

Sandwich geometry superconductor/normal metal/superconductor structures have been fabricated on LaAlO3 and cubic zirconia with laser-ablated, c-axis-oriented YBa2Cu3O(7-delta) base electrodes, 100-600 A of Au, and Nb counter electrodes, all formed in situ without breaking vacuum. Junctions range in size from 5 to 50 micron on a side. Four probe I-V measurements at 4.2 K show RnA products as low as 6 x 10 to the -9th sq cm and critical current densities up to 5.2 kA/sq cm. AC Josephson steps were observed with the application of 10-GHz radiation. The temperature dependence of Jc and the observation of the AC Josephson effect suggest that true supercurrents are present and that they do indeed represent the characteristics of the YBa2Cu3O(7-delta)/Au/Nb structure. The best results were obtained when the devices were annealed at about 450 C in O2 for 30 min after Au deposition.

Foote, M. C.↗

Quantifying the Exospheric Component of Soft X-ray Emission

High charge state heavy ions in the solar wind exchange charge with ambient neutral gas. This process creates a product ion in an excited state. During the radiative cascade process, EUV and X-ray photons are emitted with energies in the range of about 100 eV to 1 keV. Because the terrestrial exospheric density at the nominal magnetopause location is relatively high, approx. 10 cu cm, solar wind charge exchange, or SWCX, can be observed by Earth-orbiting soft X-ray instruments such as the ROSAT Position Sensitive Proportional Counters (PSPC). In this presentation, we will compare simulated and observed soft Xray emission during an event on August 18-19, 1991 and discuss the role of exospheric SWCX emission for this and other events.

Kuntz, Kip↗

The HEAO-A Scanning Modulation Collimator instrument

The Scanning Modulation Collimator X-ray instrument for the HEAO-A satellite was designed to measure celestial radiation in the range between 1 and 15 KeV and to resolve, and correlate, the position of X-ray sources with visible light sources on the celestial sphere to within 5 arc seconds. The positional accuracy is made possible by mechanical collimation of the X-ray sources viewed by the instrument. High sensitivity is provided from two systems each containing four gas filled proportional counters followed by preamplification, signal summing, pulse height analysis, pulse shape discrimination, X-ray event accumulators and telemetry processing electronics.

Roy, A.↗

Abundance of the Radioactive Be-10 in the Cosmic Radiation up to 2 GeVnucleon-l with the Balloon-borne Instrument ISOMAX1998

The Isotope Magnet Experiment (ISOMAX) a balloon-borne superconducting magnet spectrometer was designed to measure the isotopic composition of the light isotopes (3 less than or equal to Z less than or equal to 8) of the cosmic radiation up to 4 GeV nucleon (exp -1) with a mass resolution of better than 0.25 amu by using the velocity vs. rigidity technique. To achieve this stringent mass resolution ISOMAX was comprised of three major detector systems, a magnetic rigidity spectrometer with a precision drift chamber tracker in conjunction with a three-layer time-of-flight system and two silica-aerogel Cherenkov counters for the velocity determination. A special emphasis of the ISOMAX program was the accurate measurement of radioactive Be-10 with respect to its stable neighbor isotope Be-9, which provides important constraints on the age of cosmic rays in the Galaxy. ISOMAX had its first balloon flight on August 4-5, 1998, from Lynn Lake, Manitoba, Canada. Thirteen hours of data were recorded during this flight at a residual atmosphere of less than 5 g per square centimeter. The isotopic ratio at the top of the atmosphere for Be-10/Be-9 was measured to be 0.195 plus or minus 0.036 (statistical) plus or minus 0.039 (systematic) between 0.26 - 1.03GeV nucleon (exp -1) and 0.317 plus or minus 0.109 (statistical) plus or minus 0.042 (systematic) between 1.13 - 2.03GeV nucleon(exp -1). This is the first measurement of its kind above 1 GeV nucleon (exp -1). ISOMAX results tend to be higher than predictions from current propagation models.

Hams, T.↗

The effects of pre-plasma scale length on the relativistic electron beam directionality

The effects of pre-plasmas on the electron beam directionality was experimentally and numerically investigated. Single material and layered targets made of Ti and/or CH were used to simultaneously measure high-energy (≥3 MeV) electrons along two directions, pre-pulse energy and pre-plasma density. The electron directionality is quantified by using a new parameter, the electron energy ratio of the total kinetic energies along the two directions. Measurements and radiation–hydrodynamic (RH) simulations show that a large (≥3.5 μm) plasma scale length at the critical surface enhances electrons along the laser axis, and such pre-plasma conditions could only be achieved with the CH targets. Particle-in-cell simulations were performed on the RH generated pre-plasmas from Ti and CH targets, and the results show that the CH target provided conditions for higher forward momentum gains by electrons. First, the CH target allowed longer distances for electrons to interact with laser. Second, the intense laser pulse modified the critical surface, but the resulting surface differed. The CH target resulted in a smooth surface where a retro-reflection was observed while the Ti target resulted in a rippled surface that scattered the reflected light. As results, the CH electrons gained higher forward momentum via a direct-laser-acceleration in the counter propagating laser fields. So the results presented in this article show a way of controlling the high-energy electron directionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparison of depth dependence of dose and linear energy transfer spectra in aluminum and polyethylene

A set of four tissue-equivalent proportional counters (TEPCs), with their detector heads at the centers of 0 (bare), 3, 7 and 9-inch-diameter aluminum spheres, were flown on Shuttle flight STS-89. Five such detectors at the centers of polyethylene spheres were flown 1 year earlier on STS-81. The results of dose-depth dependence for the two materials convincingly show the merits of using material rich in hydrogen to decrease the radiation exposure to the crew. A comparison of the calculated galactic cosmic radiation (GCR) absorbed dose and dose-equivalent rates using the radiation transport code HZETRN with nuclear fragmentation model NUCFRG2 and the measured GCR absorbed dose rates and dose-equivalent rates shows that they agree within root mean square (rms) error of 12.5 and 8.2%, respectively. However, there are significant depth-dependent differences in the linear energy transfer (LET) spectra. A comparison for trapped protons using the proton transport code BRYNTRN and the AP-8 MIN trapped-proton model shows a systematic bias, with the model underpredicting dose and dose-equivalent rates. These results show the need for improvements in the radiation transport and/or fragmentation models.

manned↗

Dissolution of poorly soluble uranyl phosphate phases in the Metaautunite Subgroup under uranyl peroxide cage cluster forming conditions

Uranyl phosphate minerals are widespread in uranium deposits and usually exhibit very low solubility in aqueous systems. Uranyl phosphates of the autunite group and metaautunite subgroup impact the mobility of uranium in the environment and have inspired groundwater remediation strategies that emphasize their low solubility. The importance of soluble uranium-bearing macro-anions, including nanoscale uranyl peroxide cage clusters, is largely unexplored relative to solubilization of normally low-solubility uranium minerals. Eight synthetic analogs of metaautunite subgroup minerals have been prepared and placed in various alkaline aqueous solutions containing hydrogen peroxide and tetraethylammonium hydroxide. Each uranyl phosphate studied has a topologically identical anionic sheet of uranyl square bipyramids and phosphate tetrahedra combined with various cations (Li + , Na + , K + , Rb + , Cs + , Mg 2+ , Ca 2+ , Ba 2+ ) and water in the interlayer. Uranyl peroxides formed under many of the experimental conditions examined, including solid studtite [(UO 2 )(O 2 )(H 2 O) 2 ](H 2 O) 2 and soluble uranyl peroxide cage clusters containing as many as 28 uranyl ions. Uranyl phosphate solids in contact with solutions in which uranyl peroxide cage clusters formed dissolved extensively or completely. The greatest dissolution of uranyl phosphates occurred in systems that contained cations with larger hydrated radii, Li + and Na + . The details of the uranium speciation in solution depended on the pH and counter cations provided from the interlayers of the uranyl phosphate solids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The isotopic composition of helium at high rigidities

The isotopic abundance distribution of the cosmic radiation at energies beyond 1 GeV/AMU can at the present time be determined only with the geomagnetic method. A balloon-borne instrument was flown for 12 hours near the geomagnetic equator to measure the relative abundance of the helium isotopes He-3 and He-4 around 12 GV rigidity. The sharp rigidity cut-off at equatorial latitudes permitted separation of the two isotopes using a high-resolution-gas Cerenkov counter. The experiment thus confirms the predicted sharp cut-off at those latitudes and demonstrates the potential for isotopic separation of other elements, once flights of longer duration can be made.

Jordan, S. P.↗

Simulating Sulfate Aerosol Size in the Hunga Tonga Plume: Comparisons with Observations

Using the NASA GEOS Chemistry Climate Model (CCM) coupled to a detailed sectional aerosol microphysical model, we have simulated the January 2022 Hunga Tonga-Hunga Ha’apai (HTHH) plume. We have developed a version of the Global Modeling Initiative (GMI) chemistry mechanism to include the requisite sulfur chemistry and coupled it to the Community Aerosol and Radiation Model for Atmospheres (CARMA) sectional aerosol microphysics within the GEOS CCM. Our simulations focus on the lifecycle of stratospheric sulfur injected by the eruption–from the oxidation of the injected sulfur dioxide to the nucleation, growth, coagulation, hydration, and eventual settling of the volcanic sulfate aerosol particles. In order to constrain the simulated microphysics, we focus on comparing our model to observations with aerosol size information, namely in-situ particle counter observations and multi-wavelength satellite observations from OMPS-LP and SAGE-III. This eruption provides an interesting test case for our model; both the modeled gas-phase chemistry as well as the modeled aerosol microphysics are perturbed by the massive injection of water that accompanied the primary sulfur emissions from the eruption.

aerosols↗

Binary phase correlated X-ray intensity variations and flaring activity in the RS CVn binary HR 1099

The monitor proportional counter and the imaging proportional counter of the Einstein Observatory were used to observe the X-ray variability of the RS CVn binary HR 1099. The X-ray intensity is found to vary with the 2.837-day period of the binary. An intense X-ray flare was noted on February 17, 1980. The present results are explained using a star spot model, and it is suggested that the flare heated plasma cools either mainly by radiation or equally by conduction and radiation.

Agrawal, P. C.↗

2D measurements of parallel counter-streaming flows in the W7-X scrape-off layer for attached and detached plasmas

Abstract Investigations of particle parallel flow velocities have been carried out for the scrape-off layer (SOL) of the Wendelstein 7-X (W7-X) stellarator, in order to gain insights on the SOL transport properties during attached and detached plasma scenarios. The experimental evidence is based on the coherence imaging spectroscopy (CIS) diagnostic, able to measure 2D impurity emission intensity and flow velocity. The impurity monitored by CIS is C 2+ , characterized by a line-emission intensity observed to be linearly proportional to the total plasma radiated power in both attached and detached plasmas. The related C 2+ velocity shows a strong dependence on the line-averaged electron density while remaining insensitive to the input power. During attached plasmas, the velocity increases with increasing line-averaged density. The tendency reverses in the transition to and during detachment, in which the velocity decreases by at least a factor of 2. The sharp drop in velocity, together with a rise in line-emission intensity, is reliably correlated to the detachment transition and can therefore be used as one of its signatures. The impurity flow velocity appears to be well coupled with the main ions’ one, thus implying the dominant role of impurity-main ion friction in the parallelimpurity transport dynamics. In view of this SOL impurity transport regime, the CIS measurement results are here interpreted with the help of EMC3-Eirene simulations, and their major trends are already explainable with a simple 1D fluid model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proportional counter as neutron detector

A technique to separate out the dose, and lineal energy spectra of neutrons and charged particles is described. It is based on using two proportional counters, one with a wall, and the other with similar characteristics but wall made from a non-hydrogen containing material. Results of a calibration in a neutron field are also shown. c2001 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Active control of nonlinear-nonstationary response and radiation of a panel-stringer structure near a supersonic jet

This paper is on the control of nonlinear-nonstationary vibration of an aircraft-type frame-stringer structure and the acoustic radiation resulting from high levels of excitation by a nearby supersonic model jet exhaust. The objective of the control is to reduce the acoustic fatigue and the interior noise in a high-speed aircraft. Control of the structural response is achieved by actively forcing the structure with an actuator at the shock oscillation frequency whose amplitude is locked into a self-control cycle. This controller follows the amplitude modulation that results from the rotation and counter-rotation of the jet column. Results show that the peak level of the power in the structural response due to shock impingement is reduced by a factor of 63, corresponding to a power level reduction of 18 dB. As a result, new broadband components emerge with at least four harmonics contributing to the broadening of the response spectrum. At accelerating and decelerating supersonic speeds, the exhaust from the jet induces higher transient loading on the nearby flexible structure due to the occurrence of multiple shocks from the jet.

Maestrello, Lucio↗

Investigation of the CCN Activity, BC and UVBC Mass Concentrations of Biomass Burning Aerosols during the 2013 BASELInE Campaign

Biomass-burning (BB) aerosols, acting as cloud condensation nuclei (CCN), can influence cloud microphysical and radiative properties. In this study, we present CCN measured near the BB source regions over northern Southeast Asia (Doi Ang Khang, Thailand) and at downwind receptor areas (Lulin Atmospheric Background Station, Taiwan), focusing exclusively on 13-20 March 2013 as part of 2013 spring campaign of the Seven SouthEast Asian Studies (7-SEAS) intensive observation. One of the campaigns objectives is to characterize BB aerosols serving as CCN in SouthEast Asia (SEA). CCN concentrations were measured by a CCN counter at 5 supersaturation (SS) levels: 0.15%, 0.30%, 0.45%, 0.60%, and 0.75%. In addition, PM2.5 and black carbon mass concentrations were analyzed by using a tapered element oscillating microbalance and an aethalometer. It was found the number-size distributions and the characteristics of hygroscopicity (e.g., activation ratio and k) of BB aerosols in SEA have a strong diurnal pattern, and different behaviors of patterns were characterized under two distinct weather systems. The overall average value was low (0.05-0.1) but comparable with previous CCN studies in other BB source regions. Furthermore, a large fraction of UV-absorbing organic material (UVBC) and high Delta-C among BB aerosols were also observed, which suggest the existence of substantial particulate organic matter in fresh BB aerosols. These data provide the most extensive characterization of BB aerosols in SEA until now.

biomass burning aerosol↗

Hard X-ray astrophysics

Past hard X-ray and lower energy satellite instruments are reviewed and it is shown that observation above 20 keV and up to hundreds of keV can provide much valuable information on the astrophysics of cosmic sources. To calculate possible sensitivities of future arrays, the efficiencies of a one-atmosphere inch gas counter (the HEAO-1 A-2 xenon filled HED3) and a 3 mm phoswich scintillator (the HEAO-1 A-4 Na1 LED1) were compared. Above 15 keV, the scintillator was more efficient. In a similar comparison, the sensitivity of germanium detectors did not differ much from that of the scintillators, except at high energies where the sensitivity would remain flat and not rise with loss of efficiency. Questions to be addressed concerning the physics of active galaxies and the diffuse radiation background, black holes, radio pulsars, X-ray pulsars, and galactic clusters are examined.

Rothschild, R. E.↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

25 ENERGY STORAGE↗

X-ray observations to detect hot coronae around galaxies

X-ray observations were made of two nearby edge-on spiral galaxies with the Imaging Proportional Counter (IPC) on the Einstein Observatory in an effort to detect hot (1,000,000 K), gaseous galactic coronae. No diffuse emission from galactic coronae was detected. Upper limits to diffuse emission (0.3-2.9 keV) are 10 to the 39th ergs/sec (NGC 3628) and 2 x 10 to the 38th ergs/sec (NGC 4244). The measurements indicate that less than 1/1000 of the energy supplied by supernovae in these galaxies appears as soft X-rays. The energy from supernovae may be radiated away by cool gas (less than 600,000 K) whose emission is undetectable by the Einstein Observatory, or the energy may be carried away by a hot wind (10,000,000 K) which radiates inefficiently. Serendipitous X-ray sources from the two IPC fields are listed.

Bregman, J. N.↗