Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION FALL OUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Uranium Holdup Monitoring with Compton Imaging as Function of Depth and Mass

Material Control and Accountability (MC&A) programs track masses of materials flowing through production processes, where some material remains in process equipment as holdup. Quantification of these masses using gamma emissions typically involves usage of a well characterized radiation detector and assumptions of geometric configuration to constrain detection efficiencies, where the Generalized Geometry Holdup (GGH) method is often used. Uncertainties on the order of ±50% are observed, where the difficulties arise based on the asymmetric and gradient distributions of material that do not fall within the bounds of GGH. Gamma imagers provide a possible means to improve this geometric knowledge. This work describes the process used in creating a series of mass standards to aid the development of imaging algorithms for quantification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Threshold characteristics of an IR laser based on deep InAsSb/AlSb quantum well

The basic threshold characteristics of a semiconductor IR laser based on a heterostructure with deep InAs{sub 0.84}Sb{sub 0.16}/AlSb quantum wells (QWs) have been studied. The threshold carrier densities and threshold current densities of radiative and Auger recombination (AR) were found. It is shown that at certain QW parameters the AR rate is strongly (by several orders of magnitude) suppressed. In this case, the emission wavelength falls within the interval 2-3.5 {mu}m, which corresponds to the mid-IR spectral range. The internal quantum efficiency of emission at the lasing threshold was calculated and its dependence on the QW width within the AR suppression range was demonstrated. The laser structure was optimized with respect to the number of QWs.

36 MATERIALS SCIENCE↗

Puerto Rico Historical Climate Analysis: A closer look at complex tropical terrain

Small tropical islands like Puerto Rico are especially vulnerable to climate change impacts, yet are often underrepresented in most datasets because the spatial resolution is too coarse to sufficiently cover their complex terrain. This study was done to better understand how the climate has changed in the various regions of Puerto Rico, which will support a transition to renewable energy and aid in projecting future climate impacts on the residents and land they live on. This study used multiple datasets including Daymet, a daily surface weather and climatological summary; European Centre for Medium-Range Weather Forecasts Reanalysis version 5 (ERA5); and station observations. The climate variables examined here include minimum and maximum near-surface air temperature, daily precipitation, incident shortwave radiation, and large-scale upper atmosphere conditions. The time periods cover the years 1950–2019. Results in both Daymet and station observations show long-term warming trends throughout every season. In particular, the minimum winter temperatures increased the most compared with maximum and mean air temperature. Northeast Puerto Rico, where the majority of the island’s population is located, experienced the largest warming. Summertime precipitation has decreased over time, and spring and fall precipitation has increased. The largest increase in fall is because there has been more available precipitable water, lower sea-level pressure, and favorable cyclonic circulations from the trade winds over the past seven decades. Overall, wet days are getting wetter, while dry days are getting drier. While there are good solar energy potential, we see a long-term decreasing trend in shortwave radiation over time in all seasons across entire island, possibly due to the increase of cloud cover.

54 ENVIRONMENTAL SCIENCES↗

Dynamic MLC leaf sequencing for integrated linear accelerator control systems

Purpose: Leaf positions for dynamic multileaf collimator (DMLC) intensity modulated radiation therapy must be closely synchronized with MU delivery. For the Varian C3 series MLC controller, if the planned trajectory (leaf position vs. MU) requires velocities exceeding the capability of the MLC, the leaves fall behind the planned positions, causing the controller to momentarily hold the beam and thereby introduce dosimetric errors. We investigated the merits of a new commercial linear accelerator, TrueBeam, that integrates MLC control with prospective dose rate modulation. If treatment is delivered at dose rates so high that leaves would fall behind, the controller reduces the dose rate such that harmony between MU and leaf position is preserved. Methods: For three sets of DMLC leaf trajectories, point doses and two-dimensional dose distributions were measured in phantom using an ionization chamber and film, respectively. The first set, delivered using both a TrueBeam and a conventional C3 controller, comprised a single leaf bank closing at planned velocities of 2.4, 7.1, and 14 cm/s. The maximum achievable leaf velocity for both systems was 3 cm/s. The remaining two sets were derived from clinical fluence maps using a commercial treatment planning system for a range of planned dose rates and were delivered using TrueBeam set to the maximum dose rate, 600 MU/min. Generating trajectories using a planned dose rate that is lower than the delivery dose rate effectively increased the leaf velocity constraint used by the planning system for trajectory calculation. The second set of leaf trajectories was derived from two fluence maps containing regions of zero fluence obtained from representative beams of two different patient treatment plans. The third set was obtained from all nine fields of a head and neck treatment plan. For the head and neck plan, dose-volume histograms of the spinal cord and target for each planned dose rate were obtained. Results: For the single closing leaf bank trajectories, the TrueBeam control system reduced the dose rate such that the leaf velocity was less than the maximum. Dose deviations relative to the 2.4 cm/s trajectory were less than 3%. For the conventional controller, the leaves repeatedly fell behind the planned positions until the beam hold threshold was reached, resulting in deviations of up to 19% relative to the 2.4 cm/s trajectory. For the two clinical fluence maps, reducing the planned dose rate reduced the dose in the zero fluence regions by 15% and 24% and increased the delivery time by 5 s and 14 s. No significant differences were noted in the high and intermediate dose regions measured using film. The DVHs for the head and neck plan showed a 10% reduction in cord dose for 20 MU/min relative to 600 MU/min sequencing dose rate, which was confirmed by measurement. No difference in target DVHs were observed. The reduction in cord dose increased total treatment time by 1.8 min. Conclusions: Leaf sequencing algorithms for integrated control systems should be modified to reflect the reduced importance of maximum leaf velocity for accurate dose delivery.

43 PARTICLE ACCELERATORS↗

FERMI LARGE AREA TELESCOPE OBSERVATIONS OF THE CRAB PULSAR AND NEBULA

We report on gamma-ray observations of the Crab Pulsar and Nebula using 8 months of survey data with the Fermi Large Area Telescope (LAT). The high quality light curve obtained using the ephemeris provided by the Nancay and Jodrell Bank radio telescopes shows two main peaks stable in phase with energy. The first gamma-ray peak leads the radio main pulse by (281 +- 12 +- 21) mus, giving new constraints on the production site of non-thermal emission in pulsar magnetospheres. The first uncertainty is due to gamma-ray statistics, and the second arises from the rotation parameters. The improved sensitivity and the unprecedented statistics afforded by the LAT enable precise measurement of the Crab Pulsar spectral parameters: cut-off energy at E{sub c} = (5.8 +- 0.5 +- 1.2) GeV, spectral index of GAMMA = (1.97 +- 0.02 +- 0.06) and integral photon flux above 100 MeV of (2.09 +- 0.03 +- 0.18) x 10{sup -6} cm{sup -2} s{sup -1}. The first errors represent the statistical error on the fit parameters, while the second ones are the systematic uncertainties. Pulsed gamma-ray photons are observed up to approx 20 GeV which precludes emission near the stellar surface, below altitudes of around 4-5 stellar radii in phase intervals encompassing the two main peaks. A detailed phase-resolved spectral analysis is also performed: the hardest emission from the Crab Pulsar comes from the bridge region between the two gamma-ray peaks while the softest comes from the falling edge of the second peak. The spectrum of the nebula in the energy range 100 MeV-300 GeV is well described by the sum of two power laws of indices GAMMA{sub sync} = (3.99 +- 0.12 +- 0.08) and GAMMA{sub IC} = (1.64 +- 0.05 +- 0.07), corresponding to the falling edge of the synchrotron and the rising edge of the inverse Compton (IC) components, respectively. This latter, which links up naturally with the spectral data points of Cherenkov experiments, is well reproduced via IC scattering from standard magnetohydrodynamic nebula models, and does not require any additional radiation mechanism.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of Atmospheric Variations on Photovoltaic Performance and Modeling Their Effects for Days with Clear Skies: Preprint

Although variation in photovoltaic (PV) performance is predominantly influenced by clouds, performance variations also exist for days with clear skies with different amounts of atmospheric constituents that absorb and reflect different amounts of radiation as it passes through the earth's atmosphere. The extent of the attenuation is determined by the mass of air and the amounts of water vapor,aerosols, and ozone that constitute the atmosphere for a particular day and location. Because these constituents selectively absorb radiation of particular wavelengths, their impact on PV performance is sensitive to the spectral response of the PV device. The impact may be assessed by calculating the spectral mismatch correction. This approach was validated using PV module performance data atthe National Renewable Energy Laboratory (NREL) for summer, fall, and winter days with clear skies. The standard deviation of daily efficiencies for single-crystal Si, a-Si/a-Si/a-Si:Ge, CdTe, and CIGS PV modules were reduced to 0.4% to 1.0% (relative) by correcting for spectral mismatch, temperature, and angle-of-incidence effects.

14 SOLAR ENERGY↗

Implications of the In-Situ Measured Mass Absorption Cross Section of Organic Aerosols in Mexico City on the Atmospheric Energy Balance, Satellite Retrievals, and Photochemistry

The absorption of short wave incoming solar radiation by the organic component of aerosols has been examined by using data from the MCMA-2003 and the 2006 MILAGRO field campaigns. Both field efforts took place in and around Mexico City. Single Scattering Albedo (SSA) was derived as a function of wavelength (300-870 nm) by combining irradiance measurements from a Multi-Filter Rotating Shadowband Radiometer (MFRSR) and spectrally resolved actinic flux measurements by spectroradiometry with a radiative transfer model (TUV). In addition, organic aerosol mass measured by a surface deployed aerodyne aerosol mass spectrometer was used to estimate the Mass Absorption Cross-section (MAC) of Organic Carbon (OC). It was found that the MAC for OC is about 10.5 m{sup 2}/g at 300 nm and falls close to zero at about 500 nm; these values are roughly consistent with previous MAC estimates of OC, and present first in-situ observations of this quantity.

58 GEOSCIENCES↗

Digital holographic interferometry: A novel optical calorimetry technique for radiation dosimetry

Purpose: To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. Methods: The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. Results: The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ±3.45 Gy (corresponding to an uncertainty in the temperature value of ±8.3 × 10{sup −4} K). The relative dose fall off was in agreement with treatment planning system modeled data. Conclusions: First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10{sup −5} m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternating Conditional Expectations: Introducing a Non‐Parametric Statistical Method to Interpret Long‐Term Greenhouse Gas Flux Measurements Over Semi‐Arid and Wetland Ecosystems

Abstract We explore the potential of using a non‐parametric statistical method called Alternating Conditional Expectations, ACE, to quantify functional relationships in biogeosciences. Here, ACE is used to quantify the non‐linear and multi‐faceted responses of greenhouse gas fluxes to a set of biophysical forcings, when the shapes of those response surfaces are unknown. We evaluated the statistical method over two contrasting ecosystems and two contrasting time steps. One case involved quantifying the biophysical controls of water vapor and carbon dioxide (CO 2 ) fluxes over a semi‐arid oak savanna using daily integrated fluxes. The other case evaluated the responses of CO 2 and methane (CH 4 ) flux measurements to a set of biophysical forcings at a restored tidal wetland using thirty‐minute averages. The statistical model, based on 4 independent variables, explained up over 90% of the variation in daily integrated flux densities of water vapor and net carbon dioxide exchange at the savanna site. This fit was defined by distinct non‐linear responses to such drivers as gross primary production, photosynthetically active radiation, air temperature, vapor pressure deficit and soil moisture. At the tidal wetland site, we evaluated net carbon dioxide and methane fluxes with short‐term measurements to capture the influence of rising and falling tides and seasonality in biological activity. The statistical model defined the shape of the forcing of fluxes due to the roles of carbon exudates, water table depth, oxygen level in the water column, temperature and vegetation status. The statistical fits of the greenhouse gas fluxes were less precise than the savanna case. The fetch varies on a run‐to‐run basis as it is comprised of a heterogeneous mosaic of open water and vegetation. Furthermore, it is difficult to monitor the environmental conditions of the archaea and bacteria in the sediments that produce methane and carbon dioxide.

Environmental Sciences & Ecology↗

THE DWARF NOVA OUTBURSTS OF NOVA HER 1960 (=V446 HER)

V446 Her is the best example of an old nova which has developed dwarf nova (DN) eruptions in the post-nova state. We report on observed properties of the long-term light curve of V446 Her, using photometry over 19 years. Yearly averages of the outburst (OB) magnitudes show a decline of {approx}0.013 mag yr{sup -1}, consistent with the decline of other post-novae that do not have DN OBs. Previous suggestions of bimodal distributions of the amplitudes and widths of the OBs are confirmed. The OBs occur at a mean spacing of 18 days but the range of spacings is large (13-30 days). From simulations of DN OBs, it has been predicted that the OB spacing in V446 Her will increase as M-dot from the red dwarf companion slowly falls following the nova; however, the large intrinsic scatter in the spacings serves to hide any evidence of this effect. We do find a systematic change in the OB pattern in which the brighter, wider type of OBs disappeared after late 2003, and this phenomenon is suggested to be due to falling M-dot following the nova.

79 ASTRONOMY AND ASTROPHYSICS↗

Signature of a spin-up magnetar from multi-band afterglow rebrightening of GRB 100814A

In recent years, more and more gamma-ray bursts (GRBs) with late rebrightenings in their multi-band afterglows have revealed the late-time activity of their central engines. GRB 100814A is a special case among the well-sampled events, with complex temporal and spectral evolution. The single power-law shallow decay index of the optical light curve observed by GROND between 640 s and 10 ks is α{sub opt}=0.57±0.02, which apparently conflicts with expectations from the simple external shock model. In particular, there is remarkable rebrightening in the optical to near-infrared bands at late times, challenging the external shock model with synchrotron emission coming from the interaction of the blast wave with the surrounding interstellar medium. In this paper, we invoke a magnetar with spin evolution to explain the complex multi-band afterglow emission of GRB 100814A. The initial shallow decay phase in the optical bands and the plateau in the X-ray can be explained as being due to energy injection from a spin-down magnetar. At late times, with materials from the fall-back disk falling onto the central object of the burster, the angular momentum of the accreted materials is transferred to the magnetar, which leads to a spin up process. As a result, the magnetic dipole radiation luminosity will increase, resulting in significant rebrightening of the optical afterglow. We show that the model can well reproduce the observed multi-band afterglow emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward unifying the description of meson and baryon properties.

We present a Poincare covariant Faddeev equation, which enables the simultaneous prediction of meson and baryon observables using the leading order in a truncation of the Dyson-Schwinger equations that can systematically be improved. The solution describes a nucleon's dressed-quark core. The evolution of the nucleon mass with current-quark mass is discussed. A nucleon-photon current, which can produce nucleon form factors with realistic Q{sup 2} evolution, is described. Axial-vector diquark correlations lead to a neutron Dirac form factor that is negative, with r{sub 1}{sup nu} > r{sub 1}{sup nd}. The proton electric-magnetic form factor ratio falls with increasing Q{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intermediate energy photons (1 MV) to improve dose gradient, conformality, and homogeneity: Potential benefits for small field intracranial radiosurgery

A previously conceived and demonstrated principle of reducing penumbra for small radiosurgical dose fields is here now applied to a multiple beam arrangement in a stereotactic head phantom. In this work it is found that the fourfold reduction in radiological penumbra of small, single 1 MV x-ray fields translates to a more conformal, homogeneous dose distribution in the more complex beam arrangements. The film dosimetry is conducted with a high resolution digital microscope to quantify the sharp dose gradients. Further, the Gafchromic EBT film measurements in phantom are compared to calculations using the Xknife RT3 (Radionics, Burlington, MA) treatment planning software (TPS) with modeled 1 MV beam data. An orthogonal pair of coplanar beams and an 18-beam coplanar arc irradiation both yielded agreement between the modeling within the TPS and the film work. Conventional 6 MV modality is compared alongside 1 MV throughout. The 90%-50% and 90%-10% dose gradients at the intersection of the orthogonal beam pair were 1.7 and 4.7 mm for 6 MV versus 0.5 and 1.3 mm for 1 MV for an identical setup. The 18-beam coplanar arc plan yielded 90%-80% and 90%-50% dose gradients of 0.84 and 2.2 mm for 6 MV versus gradients of 0.29 and 1.36 mm for 1 MV for the midaxial slice coplanar with all beamlet axes. Uncertainties in gradient measurements were {+-}0.15 mm. The 18-beam coplanar beam arrangement represented a worst case scenario for penumbra overlap deteriorating the dose distribution. In brief, 1 MV x-rays provided superior homogeneity, conformality, and dose fall-off to 6 MV for the irradiations examined.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-F-CAMPUS-T-03: Commissioning of a Custom Fetal Lead Shield for Radiotherapy

Purpose: To evaluate the peripheral dose (PD) to a fetus during radiation therapy of pregnant patients when using a newly designed fetal lead shield (FLS). Methods: A custom FLS has been designed and fabricated for our department. The FLS (1.1 TVLs for 6 MV) is mounted on a mobile frame and can be adjusted vertically with a motor actuator. PD measurements were acquired for multiple simple square fields and for a variety of potential treatment sites a pregnant patient may be treated for including brain, head and neck (H&N) and thorax. For measurements of the brain, H&N, and thorax, an ionization chamber and OSLDs were positioned on average at a distance of 48, 29 and 26 cm, respectively, from the edge of treatment fields to mimic the approximate position of the fundus. Results: Based on our measurements, applying a 90° collimator rotation and using tertiary MLCs to define the field aperture in combination with jaws resulted in an average dose reduction of 60%. When using these planning strategies in combination with the FLS, on average, the PD was reduced by additional 25% for simple square fields and 20% for clinical plans. Conclusion: The custom FLS is a safe, effective, and relatively easy system to position. Commissioning measurements have demonstrated that the PD to the fetus can be significantly reduced when using the FLS. The comprehensive dataset obviates the need for individual patient pre-treatment dose measurements as long as the geometry falls within the commissioning limits.

60 APPLIED LIFE SCIENCES↗

Plasma-surface interactions during tokamak disruptions and rapid shutdowns

Recent progress in understanding of disruptions and in developing methods to avoid disruption damage is presented. Nearly complete mitigation of conducted heat loads has been achieved with high-Z gas jet shutdown. The resulting local radiation heat flash melting in the main chamber might be a concern in ITER, especially with beryllium walls. During the current quench, significant vessel forces can occur due to halo currents I-halo; however, these are found to fall reliably below a boundary of (halo current fraction times halo current peaking factor) <0.7 both experimentally and numerically. Numerical simulations indicate that runaway electrons (REs) could cause serious damage to hard-to reach components in ITER, making their suppression a high priority. During the current quench, less than 20% of the density required for collisional suppression of REs appears to have been achieved. Collisional suppression of REs may have been achieved, however, in full-current RE beams with gas injection. (C) 2010 Elsevier B.V. All rights reserved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementation of Triply Periodic Minimal Surfaces (TPMS) as surface objects in OpenMC

Triply Periodic Minimal Surfaces (TPMS) represent a promising geometry for future fuel designs due to their significant surface-to-volume ratio, which facilitates efficient cooling of nuclear fuel, a crucial factor for safety and efficiency. Demonstrating the remarkable capabilities of TPMS fuel requires initial modeling and simulation. This paper presents an implementation of TPMS in the Monte Carlo code OpenMC, enabling reactor physics modeling of TPMS. Here, the primary advantages over traditional methods using CAD files include reduced memory requirements for computations and high-fidelity implementation. This implementation has been tested against CAD files loaded in Serpent2, yielding promising results with low biases in the $k_{\textrm{eff}}$, comparable to biases in the material balance sheet. The implementation presented in this work will be used in future reactor physics computations related to new reactor designs involving TPMS-based fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pulse radiolysis and transient absorption spectra of aqueous solutions of sodium sulfamate

Chemical kinetics for the reactions of sulfamate ions (NH 2 SO 3 − ) with the primary products of water and nitric acid radiolysis were measured in aqueous solutions at ambient temperature. Using time-resolved electron pulse radiolysis techniques with a custom multichannel detection system, we examined the reactivity of NH 2 SO 3 − with the hydroxyl radical ( • OH), hydrogen atom (H • ), and nitrate radical (NO 3 • ). The sulfamate ion was found to react with • OH and H • with second-order rate coefficients of k • OH = (5.60 ± 0.04) × 10 6 M −1 s −1 and k H • = (7.96 ± 0.10) × 10 6 M −1 s −1 , respectively, and with NO 3 • with a rate coefficient of k NO 3 • = (1.67 ± 0.06) × 10 7 M −1 s −1 . The reactions of NH 2 SO 3 − with • OH and H • resulted in the formation of two transient radical species, one with maximum absorbance at 300 nm and a second with maxima at both 300 nm and 600 nm. These spectra are tentatively assigned to • NH 2 SO 3 and • NHSO 3 − , respectively. By measuring the absorbance of these radicals as a function of pH, the radical pK a was determined to be 9.5 ± 0.1. Overall, this work has implications for the longevity and performance of ferrous sulfamate, Fe(NH 2 SO 3 ) 2 , as a plutonium reductant in the reprocessing of used nuclear fuel.

Conrad, Jacy K. [Idaho National Laboratory (INL), ↗

Detection system for high-resolution gamma radiation spectroscopy with neutron time-of-flight filtering

A .gamma.-radiation detection system that includes at least one semiconductor detector such as HPGe-Detector, a position-sensitive .alpha.-Detector, a TOF Controller, and a Digitizer/Integrator. The Digitizer/Integrator starts to process the energy signals of a .gamma.-radiation sent from the HPGe-Detector instantly when the HPGe-Detector detects the .gamma.-radiation. Subsequently, it is determined whether a coincidence exists between the .alpha.-particles and .gamma.-radiation signal, based on a determination of the time-of-flight of neutrons obtained from the .alpha.-Detector and the HPGe-Detector. If it is determined that the time-of-flight falls within a predetermined coincidence window, the Digitizer/Integrator is allowed to continue and complete the energy signal processing. If, however, there is no coincidence, the Digitizer/Integrator is instructed to be clear and reset its operation instantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗