Combined analysis of neutron and photon flux measurements for the Jules Horowitz reactor core mapping

We study the combined analysis of nuclear measurements to improve the knowledge of the irradiation conditions in the experimental locations of the future Jules Horowitz Reactor (JHR). The goal of the present work is to measure more accurately neutron flux, photon flux and nuclear heating in the reactor. In a Material Testing Reactor (MTR), nuclear heating is a crucial parameter to design the experimental devices to be irradiated in harsh nuclear conditions. This parameter drives the temperature of the devices and of the samples. The numerical codes can predict this parameter but in-situ measurements are necessary to reach the expected accuracy. For this reason, one objective of the IN-CORE program [1] is to study the combined measurements of neutron and photon flux and their cross advanced interpretation. It should be reminded that both neutron and photon sensors are not totally selective as their signals are due to neutron and photon interactions. We intend to measure the neutron flux by three different kinds of sensors (Uranium Fission chamber, Plutonium Fission chamber and Self Powered Neutron Detector), the photon flux by two different sensors (Ionization chamber and Self Powered Gamma Detector) and the nuclear heating by two different ones (Differential calorimeter and Gamma Thermometer). For the same parameter, we expect that the use of different kinds of sensors will allow a better estimation of the aimed parameter by mixing different spectrum responses and different neutron and gamma contributions. An experimental test called CARMEN-1 is scheduled in OSIRIS reactor (CEA Saclay - France) at the end of 2011, with the goal to map irradiation locations in the reactor reflector to get a first validation of the analysis model. This article focuses on the sensor selection for CARMEN-1 experiment and to the way to link neutron and photon flux measurements in view to reduce their uncertainties but also to better assess the neutron and photon contributions to nuclear heating. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What we propose here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA made miniature fission chambers in Campbelling mode is studied. We use a theoretical model of the signal to calculate the calibration coefficient. Input parameters of the model come from statistical distribution of individual pulses. Supporting measurements have been made in the CEA Cadarache zero power reactor MINERVE. Results are compared to an empirical Campbelling mode calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stackable multi-port gas nozzles

One embodiment provides a reactor for material deposition. The reactor includes a chamber and at least one gas nozzle. The chamber includes a pair of susceptors, each having a front side and a back side. The front side mounts a number of substrates. The susceptors are positioned vertically so that the front sides of the susceptors face each other, and the vertical edges of the susceptors are in contact with each other, thereby forming a substantially enclosed narrow channel between the substrates mounted on different susceptors. The gas nozzle includes a gas-inlet component situated in the center and a detachable gas-outlet component stacked around the gas-inlet component. The gas-inlet component includes at least one opening coupled to the chamber, and is configured to inject precursor gases into the chamber. The detachable gas-outlet component includes at least one opening coupled to the chamber, and is configured to output exhaust gases from the chamber.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Piezoelectric material for use in a nuclear reactor core

In radiation environments ultrasonic nondestructive evaluation has great potential for improving reactor safety and furthering the understanding of radiation effects and materials. In both nuclear power plants and materials test reactors, elevated temperatures and high levels of radiation present challenges to ultrasonic NDE methodologies. The challenges are primarily due to the degradation of the ultrasonic sensors utilized. We present results from the operation of a ultrasonic piezoelectric transducer, composed of bulk single crystal AlN, in a nuclear reactor core for over 120 MWHrs. The transducer was coupled to an aluminum cylinder and operated in pulse echo mode throughout the irradiation. In addition to the pulse echo testing impedance data were obtained. Further, the piezoelectric coefficient d{sub 33} was measured prior to irradiation and found to be 5.5 pC/N which is unchanged from as-grown samples, and in fact higher than the measured d{sub 33} for many as-grown samples.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spectral Effects on Stress Relaxation of Inconel X-750 Springs in CANDU Reactors

CANDU reactors have been operating for periods up to about 25 years. During this time there are changes to the nuclear reactor core components that are a function of operating environment and time. It is important to know how the properties of critical core components are likely to change over the life of a reactor and therefore their behaviours are characterised long before the end of the reactor design life. Tests are typically conducted in materials test reactors. The behaviour of a material is often characterised as a function of fast neutron fluence and the expected effect of operating time is established by simply extrapolating as a function of fluence. This may be appropriate when the neutron energy spectrum for the materials test reactor matches closely the neutron spectrum where the component resides in the power reactor. However, in cases where the spectrum is very different one has to convert the accumulated dose into a unit that is common in its effect on the material properties. For many property changes in nuclear reactor cores this unit is displacements per atom (dpa).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MITR & NBSR DDE Irradiations in BR2 – Fluence in LEU Cladding and Structural Materials

The BR2 nuclear reactor is a material testing reactor (MTR) located in Mol, Belgium, and operated by the Belgian Nuclear Research Centre (SCK CEN) since 1963. The reactor is highly versatile as the number and location of fuel elements and control rods can change significantly from cycle to cycle to accommodate different needs. Argonne National Laboratory (ANL or Argonne) Reactor Conversion (RC) team has collaborated with SCK CEN for over a decade on the conversion of domestic and international research reactors from highly enriched uranium (HEU, ≥20 wt.% of 235 U) to low enriched uranium (LEU, <20 wt.% of 235 U) fuel. The U.S. High-Performance Research Reactor (USHPRR) project within the M3 Reactor Conversion Program aims at converting five U.S. high performance research reactors (MITR, MURR, NBSR, HFIR, and ATR) and one critical facility (ATR-C) to LEU fuel. These USHPRRs still use and regularly refuel with HEU fuel. Each facility has a unique reactor design, operating conditions, and fuel element design to accomplish its mission. The goal of the USHPRR project is to convert the USHPRRs and the critical facility to LEU fuel while maintaining experimental performance and ensuring safe facility operation. The current technical report focuses on two reactors requiring very high-density LEU fuel: the Massachusetts Institute of Technology Reactor (MITR) and the National Bureau of Standards Reactor (NBSR). To support the conversion of these reactors, so-called design demonstration elements (DDE) are planned to be irradiated in the BR2 reactor under conditions similar to the targeted reactors and using a prototypic geometry. In support of this experiment, SCK CEN studied and modeled the DDE irradiations using MCNP6.2 to investigate the feasibility of irradiating the MITR DDE and NBSR DDE in BR2. Argonne reviewed and confirmed the conclusions of this study. Structural analysis is another step toward converting USHPRR to LEU fuel. The objective of the current report is to provide information useful to the structural analysis of the NBSR & MITR DDEs to support its irradiation in BR2. Specifically, the goal is to provide the fast neutron (E>0.1MeV) fluence in the cladding of the fuel plates in BR2 for the whole period of irradiation (8 cycles for MITR DDE and 10 cycles for NBSR DDE). Additionally, fast neutron fluences in the side plates and in the NBSR DDE’s outside plates were calculated and reported. Neutronic calculations were performed using MCNP6.2 on the RTRHPC cluster.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of Metallic Structural Materials for Molten Salt Reactors

In the US and around the world, significant interest surrounds development and deployment of nuclear systems using molten salts to transfer heat. Several configurations are being explored, including the use of fluoride salts either as the primary coolant of a reactor with solid fuel or with the fissile material dissolved in the salt. Molten Salt Reactors (MSRs) with fluoride salt typically have a thermal neutron spectrum. There are also fast-spectrum reactors that could use chloride salts to transfer heat. As a result of operation of the Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory during the 1960s, a system with uranium fuel dissolved in a fluoride-salt medium is the most well-established technology. A nickel alloy with about 6%Cr and molybdenum as a solid solution strengthening agent was developed and deployed for all structural applications in this reactor. The alloy was commercialized as Hastelloy N. During these experiments and in post-decommissioning characterization of material behavior, it was determined that the most significant challenges for structural materials are embrittlement, from helium introduced by transmutation of Ni, and corrosion and grain boundary embrittlement from the fission product tellurium. The MSRE had an outlet temperature of approximately 650°C. The mechanical properties of Hastelloy N are not sufficient to support long-term operation of an MSR above this temperature. Qualification of a material for use in the ASME Boiler and Pressure Vessel Code, Section III, “Rules for Construction of Nuclear Facility Components,” Division 5, “High Temperature Reactors,” will facilitate licensing with the Nuclear Regulatory Commission. Hastelloy N has not been qualified for use in nuclear construction, and significant additional characterization would be required for Code qualification. Given that this alloy is susceptible to He embrittlement and has limited high-temperature strength, it is not recommended that Code qualification be pursued. Instead, it is recommended that a systematic development program be initiated to develop new nickel alloys that contain a fine, stable dispersion of intermetallic particles to trap He at the interface between the matrix and particle and with increased solid solution strengthening from addition of refractory elements. Extensive screening of attractive alloy compositions for elevated temperature strength, microstructural stability, weldability, and resistance to He embrittlement (characterized using ion implantation) will lead to an alloy down-selection for commercialization and Code qualification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modification of the Core Cooling System of TRIGA 2000 Reactor

To accomplish safety requirements, a set of actions has to be performed following the recommendations of the IAEA safety series 35 applied to research reactor. Such actions are considered in modernization of the old system, improving the core cooling system and safety evaluations. Due to the complexity of the process and the difficulty in putting the apparatus in the reactor core, analytical and experimental study on the determination of flow and temperature distribution in the whole coolant channel are difficult to be done. In the present work, a numerical study of flow and temperature distribution in the coolant channel of TRIGA 2000 has been carried out using CFD package. For this study, simulations were carried out on 3-D tested model. The model consists of the reactor tank, thermal and thermalizing column, reflector, rotary specimen rack, chimney, fuel element, primary pipe, diffuser, beam tube and a part of the core are constructed by 1.50 million unstructured tetrahedral cell elements. The results show that for the initial condition (116 fuel elements in the core) and for the inlet temperature of 24 deg. C and the primary velocity of 5.6 m/s, there no boiling phenomena occur in the coolant channel. Due to this result, it is now possible to improve the core cooling system of TRIGA 2000 reactor. Meanwhile, forced flow from the diffuser system only affected the flow pattern in the outside of chimney and put on a small effect to the fluid flow's velocity in the inside of chimney.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗