Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Beam Instrumentation Challenges for the Fermilab PIP-II Accelerator

Fermilab is undertaking the development of a new 800 MeV superconducting RF linac to replace it’s present normal conducting 400 MeV linac. The PIP-II linac warm front-end consists of an ion source, LEBT, RFQ and MEBT which includes an arbitrary pattern bunch chopper, to generate a 2.1 MeV, 2mA H⁻ beam. This is followed immediately by a series of superconducting RF cryomodules to produce a 800 MeV beam. Commissioning, operate and safety present challenges to the beam instrumentation. This paper describes these beam instrumentation challenges and the choices made for PIP-II.

43 PARTICLE ACCELERATORS↗

Ion acceleration in a helicon source due to the self-bias effect

Time-averaged plasma potential differences up to 165 V over several hundred Debye lengths are observed in low pressure (p{sub n} < 1 mTorr) expanding argon plasmas in the Madison Helicon eXperiment (MadHeX). The potential gradient leads to ion acceleration greater than that predicted by ambipolar expansion, exceeding E{sub i} Almost-Equal-To 7 kT{sub e} in some cases. RF power up to 500 W at 13.56 MHz is supplied to a half-turn, double-helix antenna in the presence of a nozzle magnetic field, adjustable up to 1 kG. A retarding potential analyzer (RPA) measures the ion energy distribution function (IEDF) and a swept emissive probe measures the plasma potential. Single and double probes measure the electron density and temperature. Two distinct mode hops, the capacitive-inductive (E-H) and inductive-helicon (H-W) transitions, are identified by jumps in density as RF power is increased. In the capacitive (E) mode, large fluctuations of the plasma potential (V{sub p-p} Greater-Than-Or-Equivalent-To 140V, V{sub p-p}/V{sub p} Almost-Equal-To 150%) exist at the RF frequency and its harmonics. The more mobile electrons can easily respond to RF-timescale gradients in the plasma potential whereas the inertially constrained ions cannot, leading to an initial flux imbalance and formation of a self-bias voltage between the source and expansion chambers. In the capacitive mode, the ion acceleration is not well described by an ambipolar relation, while in the inductive and helicon modes the ion acceleration more closely follows an ambipolar relation. The scaling of the potential gradient with the argon flow rate and RF power are investigated, with the largest potential gradients observed for the lowest flow rates in the capacitive mode. The magnitude of the self-bias voltage agrees with that predicted for RF self-bias at a wall. Rapid fluctuations in the plasma potential result in a time-dependent axial electron flux that acts to 'neutralize' the accelerated ion population, resulting in a zero net time-averaged current through the acceleration region when an insulating upstream boundary condition is enforced. Grounding the upstream endplate increases the self-bias voltage compared to a floating endplate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion bombardment in RF guns

We use the ponderomotive potential of the RF field to study the motion of ions in an RF gun. We apply this method to the BNL 1/2-cell SRF photogun and demonstrate that a significant portion of the ions produced in the gun can reach the cathode if no special precautions are taken. Also, we propose simple mitigation techniques that can reduce the rate of ion bombardment.

43 PARTICLE ACCELERATORS↗

Extraction characteristics of a low-energy ion beam system with a remote plasma chamber

Low-energy argon beams were extracted from a dual-chamber ion source system. The first chamber is a quartz cylinder where dense inductively coupled plasmas were produced using 13.56 MHz radio frequency (rf) power. The discharge was driven into an adjacent chamber which acts as a reservoir for ion beam extraction using a dual-electrode extractor configuration. Extraction of ions from the second chamber with energies in the 100 eV range was achieved while minimizing fluctuations induced by the rf signal. A custom-built retarding potential analyzer was used to analyze the effectiveness of ion beam transport using the remote plasma chamber. Well-defined beams were extracted between 60 and 100 V extraction potentials at 50–100 W rf powers. An increase in rf power resulted in an increase in average ion energy, increase in ion current density while the energy spread remains constant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An overview of LINAC ion sources

This paper discusses ion sources used in high-duty-factor proton and H{sup -} Linacs as well as in accelerators utilizing multi-charged heavy ions, mostly for nuclear physics applications. The included types are Electron Cyclotron Resonance (ECR) sources as well as filament and rf driven multicusp sources. The paper does not strive to attain encyclopedic character but rather to highlight major lines of development, peak performance parameters and type-specific limitations and problems of these sources. The main technical aspects being discussed are particle feed, plasma generation and ion production by discharges, and plasma confinement.

43 PARTICLE ACCELERATORS↗

Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast fall-time ion beam in neutron generators

Ion beam with a fast fall time is useful in building neutron generators for the application of detecting hidden, gamma-shielded SNM using differential die-away (DDA) technique. Typically a fall time of less than 1 {micro}s can't be achieved by just turning off the power to the ion source due to the slow decay of plasma density (partly determined by the fall time of the RF power in the circuit). In this paper, we discuss the method of using an array of mini-apertures (instead of one large aperture beam) such that gating the beamlets can be done with low voltage and a small gap. This geometry minimizes the problem of voltage breakdown as well as reducing the time of flight to produce fast gating. We have designed and fabricated an array of 16 apertures (4 x 4) for a beam extraction experiment. Using a gating voltage of 1400 V and a gap distance of 1 mm, the fall time of extracted ion beam pulses is less than 1 {micro}s at various beam energies ranging between 400 eV to 800 eV. Usually merging an array of beamlets suffers the loss of beam brightness, i.e., emittance growth, but that is not an important issue for neutron source applications.

43 PARTICLE ACCELERATORS↗

Operation of the ORNL High Particle Flux Helicon Plasma Source

A high power, high particle flux rf-based helicon plasma source has been constructed at ORNL and operated at power levels up to 30 kW. High-density hydrogen and helium plasmas have been produced. The source has been designed as the basis for a linear plasma materials interaction (PMI) test facility that will generate particle fluxes {Gamma}{sub p}10{sup 23} m{sup -3} s{sup -1}, and utilize additional ion and electron cyclotron heating to produce high parallel (to the magnetic field) heat fluxes of {approx}10 MW/m{sup 2}. An rf-based source for PMI research is of interest because high plasma densities are generated with no internal electrodes, allowing true steady state operation with minimal impurity generation. The ORNL helicon source has a diameter of 15 cm and to-date has operated at a frequency f = 13.56 MHz, with magnetic field strength |B| in the antenna region up to {approx}0.15 T. Maximum densities of 3x10{sup 19} m{sup -3} in He and 2.5x10{sup 19} m{sup -3} in H have been achieved. Radial density profiles have been seen to be dependent on the axial |B| profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RF System Requirements for a Medium-Energy Electron-Ion Collider (MEIC) at JLab

JLab is studying options for a medium energy electron-ion collider that could fit on the JLab site and use CEBAF as a full-energy electron injector. A new ion source, linac and booster would be required, together with collider storage rings for the ions and electrons. In order to achieve the maximum luminosity these will be high-current storage rings with many bunches. We present the high-level RF system requirements for the storage rings, ion booster ring and high-energy ion beam cooling system, and describe the technology options under consideration to meet them. We also present options for staging that might reduce the initial capital cost while providing a smooth upgrade path to a higher final energy. The technologies under consideration may also be useful for other proposed storage ring colliders or ultimate light sources.

43 PARTICLE ACCELERATORS↗

Direct plasma injection scheme with beam extraction in a radio frequency quadrupole linac cavity

Direct plasma injection scheme (DPIS) is a recently developed idea about beam injection into a radio frequency quadrupole (RFQ) linac to obtain high current pulsed heavy ion beam. Since a laser ion source is directly connected to an RFQ linac, a low energy beam transport is not needed. An ion beam is extracted at the edge of the cavity. We shifted the extraction position in the RFQ cavity to improve the beam loss problem due to beam diverging before arriving at the entrance of the RFQ electrode region. In this scheme, ion beam is extracted at the entrance of the RFQ electrode region and the extracted beam is immediately captured by a rf quadrupole electric field. A plasma electrode is inserted in the accelerator resonant cavity. It is required to avoid serious effect on the acceleration characteristics of the RFQ linac. The rf properties were measured using a network analyzer to verify the effect. The shifts of resonant frequency were negligibly small by inserting the electrode. The measurements of the electric field distribution along the beam axis in the RFQ linac showed that the plasma electrode had little effect on it. The result of beam acceleration experiment showed that the beam current was increased by about 20%. It was confirmed that the beam loss was reduced by this scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Can we estimate plasma density in ICP driver through electrical parameters in RF circuit?

To avoid regular maintenance, invasive plasma diagnostics with probes are not included in the inductively coupled plasma (ICP) based ITER Neutral Beam (NB) source design. Even non-invasive probes like optical emission spectroscopic diagnostics are also not included in the present ITER NB design due to overall system design and interface issues. As a result, negative ion beam current through the extraction system in the ITER NB negative ion source is the only measurement which indicates plasma condition inside the ion source. However, beam current not only depends on the plasma condition near the extraction region but also on the perveance condition of the ion extractor system and negative ion stripping. Nevertheless, inductively coupled plasma production region (RF driver region) is placed at distance (∼ 30cm) from the extraction region. Due to that, some uncertainties are expected to be involved if one tries to link beam current with plasma properties inside the RF driver. Plasma characterization in source RF driver region is utmost necessary to maintain the optimum condition for source operation. In this paper, a method of plasma density estimation is described, based on density dependent plasma load calculation.

43 PARTICLE ACCELERATORS↗

Ag ion generation irradiated by Nd:YAG laser onto solid target for use of direct plasma injection scheme

Direct plasma injection scheme (DPIS) is an acceleration scheme which consists of laser ion source and a radio frequency quadrupole linac (RFQ) linac for high current heavy ion acceleration. With this scheme, over 60 mA of carbon and aluminum beam was achieved at the RFQ exit. We are planning to accelerate Ag ions as a heavier material than used previously. Ag plasma properties using Nd:YAG laser (2.3 J/6 ns) were measured toward the acceleration with DPIS. The results showed that the highest ion yield was obtained at Ag{sup 15+}. Based on these results, multicharged Ag ion transportation inside RFQ was simulated and the expected current at the exit of RFQ was over 14 mA for Ag{sup 15+} using the RFQ dedicated for Ag acceleration.

36 MATERIALS SCIENCE↗

Measurement of radial and axial high energy x-ray spectra in electron cyclotron resonance ion source plasmas

Radial and axial x-ray measurements of electron cyclotron resonance ion sources operating at microwave frequencies of 6.4 and 14 GHz are presented. Results indicate a greater detected photon energy in the radial direction than the axial direction for both the 6.4 GHz source and the 14 GHz source. It is also seen that the 14 GHz source produces x-rays with higher energies, when compared to the 6.4 GHz source, in both radial and axial directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stability study of all-permanent-magnet electron cyclotron resonance ion source

Beam intensity fluctuation was investigated using an electron cyclotron resonance ion source of an all-permanent-magnet type under development for highly stable beam intensity. While the source achieved a stability of better than 3.2% by strict regulation of the coolant temperature change within {+-}0.1 deg. C, the intensity varies strongly with intentional changes in the temperature of the plasma chamber coolant. The influence of the temperature on chamber expansion, magnetic field strength, and vacuum was measured or estimated in detail. The result shows that a slight change in vacuum and magnetic field strength has considerable influence on the intensity fluctuation.

43 PARTICLE ACCELERATORS↗

Performance of a liquid Ga target for Laser Ion Source

We experimentally proved the feasibility of a liquid-based target for Laser Ion Source (LIS) application. The target consists of melted metal gallium contained in a heated crucible. Ions current resulting from laser irradiation. Moreover, given the explosive ablation mechanism involved, each laser shot has been found to induce fluctuations in the surface level. It takes about 0.7 sec to recover the steady condition fully. Despite the maximum fluctuation being 2.7 mm (top-bottom maximum displacement), these fluctuations have shown no significant influence on total ion current and are independent of the temperature of the sample within the tested repetition rate. This study provides valuable insights into the potential of employing such a system for LIS.

43 PARTICLE ACCELERATORS↗

The use of particle-in-cell codes for designing electron cyclotron resonance ion sources (invited) (abstract)

We illustrate how particle-in-cell simulation techniques have been useful in past design and modeling of electron cyclotron resonance (ECR) ion sources, and discuss advances that will benefit how they can continue to be useful in the future. Electromagnetic particle-in-cell codes excel in situations of interesting geometry and magnetic field nonuniformity. We review early particle-in-cell design work leading up to the validation of volume heating effects in carefully tailored flat-field-type ECR sources. Modern computing power now favors fully three-dimensional simulation, with more realistic rf injection and accessibility modeling, and confinement field representation, for more optimal design capability, and more thorough investigation of electromagnetic transport in novel, more efficient ECR heating concepts. We also demonstrate algorithm advances, including particle-fluid hybrid methods that promise relief from computational restrictions of earlier simulations, specifically the scaling requirements associated with the small Debye length of the ECR plasma relative to its total size. Particle-in-cell codes also offer the potential for accurate modeling of particle creation, destruction, and transport dynamics. We will illustrate these capabilities from recent work incorporating neutral transport, ionization, and recombination physics, aimed at optimization of ion current in heavy ion sources. This work involves accurate modeling of geometrically localized sources, and points toward future integrated models covering the full range of physics from ion production to extraction.

43 PARTICLE ACCELERATORS↗

Discharge regime of non-ambipolarity with a self-induced steady-state magnetic field in plasma sources with localized radio-frequency power deposition

Involving the idea for the Biermann effect known from space physics as well as recent discussions on non-ambipolarity of the electron and ion fluxes in low-pressure discharges, the study builds the discharge pattern in a source with localized RF power deposition outside the region of high electron density. A vortex dc current flowing in an RF discharge and a steady-state magnetic field induced by this current govern the discharge behavior. Owing to a shift in the positions of the electron-density and plasma-potential maxima, the dc current is driven with the purpose of keeping the conservativity of the dc field in the discharge. The results present the spatial structure of a discharge in a regime of non-ambipolarity of the electron and ion fluxes, including its modifications by the magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Induction heating pure vapor source of high temperature melting point materials on electron cyclotron resonance ion source

Multicharged ions that are needed are produced from solid pure material with high melting point in an electron cyclotron resonance ion source. We develop an evaporator by using induction heating (IH) with multilayer induction coil, which is made from bare molybdenum or tungsten wire without water cooling and surrounding the pure vaporized material. We optimize the shapes of induction coil and vaporized materials and operation of rf power supply. We conduct experiment to investigate the reproducibility and stability in the operation and heating efficiency. IH evaporator produces pure material vapor because materials directly heated by eddy currents have no contact with insulated materials, which are usually impurity gas sources. The power and the frequency of the induction currents range from 100 to 900 W and from 48 to 23 kHz, respectively. The working pressure is about 10{sup -4}-10{sup -3} Pa. We measure the temperature of the vaporized materials with different shapes, and compare them with the result of modeling. We estimate the efficiency of the IH vapor source. We are aiming at the evaporator's higher melting point material than that of iron.

36 MATERIALS SCIENCE↗