Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Double-Crystal Rocking Curve Simulation Using 2D Spectral Angular Diagrams of X-Ray Radiation

A new approach to numerical simulation of double-crystal rocking curves is proposed. This approach is based on the use of experimental spectral angular diagrams of X-ray intensity distribution. Special calculation algorithms, which take into account the instrumental function of X-ray diffractometer and possible effects of dispersion and Bragg reflection asymmetry, have been developed and applied. A specific feature of the proposed approach is the possibility of visualizing the 2D spectral angular diagram of X-ray beam after its interaction with each element of the scheme. The approach makes it possible to perform calculations for a wide range of radiation sources (from an X-ray tube with any anode to a synchrotron radiation source) and X-ray optical elements (slits and monochromators). A comparison of simulation results and experimental data for a Si(110) crystal sample has confirmed adequacy of the proposed approach and its applicability for simulating diffraction patterns recorded in real experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ASEDRA Evaluation Final Report.

The performance of the Advanced Synthetically Enhanced Detector Resolution Algorithm (ASEDRA) was evaluated by performing a blind test of 29 sets of gamma-ray spectra that were provided by DNDO. ASEDRA is a post-processing algorithm developed at the Florida Institute of Nuclear Detection and Security at the University of Florida (UF/FINDS) that extracts char-acteristic peaks in gamma-ray spectra. The QuickID algorithm, also developed at UF/FINDS, was then used to identify nuclides based on the characteristic peaks generated by ASEDRA that are inferred from the spectra. The ASEDRA/QuickID analysis results were evaluated with respect to the performance of the DHSIsotopeID algorithm, which is a mature analysis tool that is part of the Gamma Detector Response and Analysis Software (GADRAS). Data that were used for the blind test were intended to be challenging, and the radiation sources included thick shields around the radioactive materials as well as cargo containing naturally occurring radio-active materials, which masked emission from special nuclear materials and industrial isotopes. Evaluation of the analysis results with respect to the ground truth information (which was provided after the analyses were finalized) showed that neither ASEDRA/QuickID nor GADRAS could identify all of the radiation sources correctly. Overall, the purpose of this effort was primarily to evaluate ASEDRA, and GADRAS was used as a standard against which ASEDRA was compared. Although GADRAS was somewhat more accurate on average, the performance of ASEDRA exceeded that of GADRAS for some of the unknowns. The fact that GADRAS also failed to identify many of the radiation sources attests to the difficulty of analyzing the blind-test data that were used as a basis for the evaluation. This evaluation identified strengths and weaknesses of the two analysis approaches. The importance of good calibration data was also clear because the performance of both analysis methods was impeded by the inability to define the energy calibration accurately. Acronyms ACHIP adaptive chi-processed ASEDRA Advanced Synthetically Enhanced Detector Resolution Algorithm DNDO Domestic Nuclear Detection Office DRFs Detector Response Functions FINDS Florida Institute of Nuclear Detection and Security FWHM full-width half-maximum GADRAS Gamma Detector Response Analysis Software GUI graphical user interface HEU highly enriched uranium HPGe high purity germanium ID identification NaI Sodium iodide NNSA National Nuclear Security Administration NORM Naturally Occurring Radioactive Materials ppm parts per million SNL Sandia National Laboratories UF University of Florida WGPu weapons-grade plutonium

Mitchell, Dean J↗

X-pinch source of subnanosecond soft X-ray pulses based on small-sized low-inductance current generator

For the first time, the regime of a micrometer-size hot spot formation is impemented for an X-pinch in a plasma, which is fed from a current generator based on low-inductance capacitors and rapid current switches. The configurations of X-pinches, which can be used effectively as point sources of soft X-rays with this type of current generator, are determined. A prototype of a small-size radiation source for high-resolution point projection X-ray radiography has been constructed. The main parameters of X-pinch as a radiation source are analyzed and compared with X-pinch parameters in high-voltage setups with shaping lines. An analysis of the data on the operation of X-pinches in generators with different parameters has led to simple relations that can be used to select optimal initial X-pinch parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power Generation from a Radiative Thermal Source Using a Large-Area Infrared Rectenna

Electrical power generation from a moderate-temperature thermal source by means of direct conversion of infrared radiation is important and highly desirable for energy harvesting from waste heat and micropower applications. Here, we demonstrate direct rectified power generation from an unbiased large-area nanoantenna-coupled tunnel diode rectifier called a rectenna. Using a vacuum radiometric measurement technique with irradiation from a temperature-stabilized thermal source, a generated power density of 8 nW / cm 2 is observed at a source temperature of 450°C for the unbiased rectenna across an optimized load resistance. The optimized load resistance for the peak power generation for each temperature coincides with the tunnel diode resistance at zero bias and corresponds to the impedance matching condition for a rectifying antenna. Current-voltage measurements of a thermally illuminated large-area rectenna show current zero crossing shifts into the second quadrant indicating rectification. Photon-assisted tunneling in the unbiased rectenna is modeled as the mechanism for the large short-circuit photocurrents observed where the photon energy serves as an effective bias across the tunnel junction. Furthermore, the measured current and voltage across the load resistor as a function of the thermal source temperature represents direct current electrical power generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An ultrashort pulse ultra-violet radiation undulator source driven by a laser plasma wakefield accelerator

Narrow band undulator radiation tuneable over the wavelength range of 150–260 nm has been produced by short electron bunches from a 2 mm long laser plasma wakefield accelerator based on a 20 TW femtosecond laser system. The number of photons measured is up to 9 × 10{sup 6} per shot for a 100 period undulator, with a mean peak brilliance of 1 × 10{sup 18} photons/s/mrad{sup 2}/mm{sup 2}/0.1% bandwidth. Simulations estimate that the driving electron bunch r.m.s. duration is as short as 3 fs when the electron beam has energy of 120–130 MeV with the radiation pulse duration in the range of 50–100 fs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling Space Radiation with Radiomimetic Agent Bleomycin

Space radiation consists of proton and helium from solar particle events (SPE) and high energy heavy ions from galactic cosmic ray (GCR). This mixture of radiation with particles at different energy levels has different effects on biological systems. Currently, majority studies of radiation effects on human were based on single-source radiation due to the limitation of available method to model effects of space radiation on living organisms. While NASA Space Radiation Laboratory is working on advanced switches to make it possible to have a mixed field radiation with particles of different energies, the radiation source will be limited. Development of an easily available experimental model for studying effects of mixed field radiation could greatly speed up our progress in our understanding the molecular mechanisms of damage and responses from exposure to space radiation, and facilitate the discovery of protection and countermeasures against space radiation, which is critical for the mission to Mars. Bleomycin, a radiomimetic agent, has been widely used to study radiation induced DNA damage and cellular responses. Previously, bleomycin was often compared to low low Linear Energy Transfer (LET) gamma radiation without defined characteristics. Our recent work demonstrated that bleomycin could induce complex clustered DNA damage in human fibroblasts that is similar to DNA damage induced by high LET radiation. These type of DNA damage is difficult to repair and can be visualized by gamma-H2Ax staining weeks after the initial insult. The survival ratio between early and late plating of human fibroblasts after bleomycin treatment is between low LET and high LET radiation. Our results suggest that bleomycin induces DNA damage and other cellular stresses resembling those resulted from mixed field radiation with both low and high LET particles. We hypothesize that bleomycin could be used to mimic space radiation in biological systems. Potential advantages and limitations of using bleomycin to treat biological specimen as an easily available model to study effects of space radiation on biological systems and to develop countermeasures for space radiation associated risks will be discussed.

Lu, Tao↗

Absolute frequency measurements for emission transitions of molecular iodine in the range of 1053 – 1068 nm

Results of high-precision frequency measurements are presented for certain components of the {sup 127}I{sub 2} hyperfine structure, which correspond to emission transitions of the B – X band in the range of 1053 – 1068 nm. The frequencies are measured by using a femtosecond optical frequency synthesiser based on a Ti:sapphire laser. The hyperfine structure is resolved by the method of three-level laser spectroscopy. The frequency-doubled cw Nd : YAG laser is used as an excitation radiation source, and the probe radiation in the range of 1050 – 1070 nm is generated by an external-cavity diode laser. The frequencies of both lasers are simultaneously locked to those of two adjacent hyperfine structure components of iodine lines, which have a common upper level. Correspondingly, the frequency of the Nd : YAG laser is locked to the frequency of the absorption transition component, and the diode laser frequency – to the frequency of the emission transition component. The radiation frequency of the diode laser ‘locked’ in this way is measured. Frequencies of 18 hyperfine structure components for six emission lines corresponding to the bands (32 – 54) and (32 – 53) are measured. The relative uncertainty of the measurement is 8 × 10{sup –10}. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Differential Phase Contrast with a Segmented Detector in a Scanning X-ray Microprobe

Scanning X-ray microprobes are unique tools for the nanoscale investigation of specimens from the life, environmental, materials and other fields of sciences. Typically they utilize absorption and fluorescence as contrast mechanisms. Phase contrast is a complementary technique that can provide strong contrast with reduced radiation dose for weakly absorbing structures in the multi-keV range. In this paper the development of a segmented charge-integrating silicon detector which provides simultaneous absorption and differential phase contrast is reported. The detector can be used together with a fluorescence detector for the simultaneous acquisition of transmission and fluorescence data. It can be used over a wide range of photon energies, photon rates and exposure times at third-generation synchrotron radiation sources, and is currently operating at two beamlines at the Advanced Photon Source. Images obtained at around 2 keV and 10 keV demonstrate the superiority of phase contrast over absorption for specimens composed of light elements.

43 PARTICLE ACCELERATORS↗

Polarization Studies of CdZnTe Detectors Using Synchrotron X-ray Radiation

High densities of impurities and defects lead to severe charge-carrier trapping that can be major issues in assuring the high performance of CZT detectors. For some medical-imaging applications, the typical X-ray flux can be very high. Under such high irradiation conditions, the trapped charge builds up inside the detector affecting its stability. This phenomenon generally is termed the polarization effect. We conducted detailed studies on polarization in CZT crystals employing a highly collimated synchrotron X-ray radiation source available at Brookhaven's National Synchrotron Light Source (NSLS). We were able to induce polarization effects by irradiating specific areas within the detector. These measurements allowed us to make, for the first time, a quantitative comparison between areas where polarization is induced, and the electron- and hole-collection X-ray maps obtained at low flux, where no polarization is induced. We discuss the results of these polarization studies.

43 PARTICLE ACCELERATORS↗

Two-Step Calibration of a Multiwavelength Pyrometer for High Temperature Measurement Using a Quartz Lamp

There is no theoretical upper temperature limit for pyrometer application in temperature measurements. NASA Glenn's multiwavelength pyrometer can make measurements over wide temperature ranges. However, the radiation spectral response of the pyrometer's detector must be calibrated before any temperature measurement is attempted, and it is recommended that calibration be done at temperatures close to those for which measurements will be made. Calibration is a determination of the constants of proportionality at all wavelengths between the detector's output (voltage) and its input signals (usually from a blackbody radiation source) in order to convert detector output into radiation intensity. To measure high temperatures, the detectors are chosen to be sensitive in the spectral range from 0.4 to 2.5 micrometers. A blackbody furnace equilibrated at around 1000 C is often used for this calibration. Though the detector may respond sensitively to short wavelengths radiation, a blackbody furnace at 1000 C emits only feebly at very short wavelengths. As a consequence, the calibration constants that result may not be the most accurate. For pyrometry calibration, a radiation source emitting strongly at the short wavelengths is preferred. We have chosen a quartz halogen lamp for this purpose.

Ng, Daniel↗

Radiograph and passive data analysis using mixed variable optimization

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing radiography analysis. For example, certain embodiments perform radiographic analysis using mixed variable computation techniques. One exemplary system comprises a radiation source, a two-dimensional detector for detecting radiation transmitted through a object between the radiation source and detector, and a computer. In this embodiment, the computer is configured to input the radiographic image data from the two-dimensional detector and to determine one or more materials that form the object by using an iterative analysis technique that selects the one or more materials from hierarchically arranged solution spaces of discrete material possibilities and selects the layer interfaces from the optimization of the continuous interface data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IR and THz Beamlines at the Metrology Light Source of the PTB

The low-energy electron storage ring Metrology Light Source (MLS), a dedicated synchrotron radiation source, is in user operation since April 2008. As a special option it provides coherent synchrotron radiation (CSR) in the THz range when it is operated in a low-alpha mode with short electron bunches. At the MLS three beamlines dedicated to the use of IR and THz radiation were designed, built and commissioned.

43 PARTICLE ACCELERATORS↗

X-ray optics for laser-plasma sources: Aplications of intense SXR and EUV radiation pulses

In this work we present a short review of SXR and EUV optics that have been designed and developed for experiments concerning material processing and imaging, using a laser-plasma radiation source based on a gas puff target. Three different kinds of mirrors employed as the EUV collectors are presented: the grazing incidence axisymmetrical ellipsoidal mirror, the grazing incidence multifoil mirror, and the ellipsoidal mirror with Mo/Si multilayer coating. Experiments concerning characterization of the mirrors were performed using EUV radiation from Kr or Xe plasmas produced in a double stream gas puff target irradiated with Nd:YAG laser pulses (4ns, 0.8 J, 10 Hz). Intensity of the focused radiation was sufficient for micromachining of organic polymers and surface modification of organic and inorganic solids. Different kinds of micro-and nanostructures created in near-surface layers of different kinds polymers were obtained. Significant differences were revealed in XPS spectra acquired for irradiated and not irradiated polymers.

36 MATERIALS SCIENCE↗

EBT2 dosimetry of x-rays produced by the electron beam from a Plasma Focus for medical applications

The electron beam emitted from the back of Plasma Focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A Plasma Focus device is being developed to this aim, to be utilized as an x-ray source. The electron beam is driven to impinge on 50 {mu}m brass foil, where conversion x-rays are generated. Measurements with gafchromic film are performed to analyse the attenuation of the x-rays beam and to predict the dose given to the culture cell in radiobiological experiments to follow.

61 RADIATION PROTECTION AND DOSIMETRY↗

AN OPEN-SOURCE NEUTRINO RADIATION HYDRODYNAMICS CODE FOR CORE-COLLAPSE SUPERNOVAE

We present an open-source update to the spherically symmetric, general-relativistic hydrodynamics, core-collapse supernova (CCSN) code GR1D. The source code is available at http://www.GR1Dcode.org. We extend its capabilities to include a general-relativistic treatment of neutrino transport based on the moment formalisms of Shibata et al. and Cardall et al. We pay special attention to implementing and testing numerical methods and approximations that lessen the computational demand of the transport scheme by removing the need to invert large matrices. This is especially important for the implementation and development of moment-like transport methods in two and three dimensions. A critical component of neutrino transport calculations is the neutrino–matter interaction coefficients that describe the production, absorption, scattering, and annihilation of neutrinos. In this article we also describe our open-source neutrino interaction library NuLib (available at http://www.nulib.org). We believe that an open-source approach to describing these interactions is one of the major steps needed to progress toward robust models of CCSNe and robust predictions of the neutrino signal. We show, via comparisons to full Boltzmann neutrino-transport simulations of CCSNe, that our neutrino transport code performs remarkably well. Furthermore, we show that the methods and approximations we employ to increase efficiency do not decrease the fidelity of our results. We also test the ability of our general-relativistic transport code to model failed CCSNe by evolving a 40-solar-mass progenitor to the onset of collapse to a black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Capabilities of the INL ZPPR to Support Active Interrogation Research with SNM

For over 40 years Idaho National Laboratory (INL) and its predecessor organizations have maintained and operated the Zero-Power Physics Reactor (ZPPR) as a test bed for studying reactor physics and nuclear reactor design. Although the ZPPR is no longer operated as an active research reactor, it’s infrastructure (radiation shielding, safety systems, physical safeguards) and special nuclear material (SNM) inventory (variably enriched uranium and plutonium fuels available in metallic, oxide, alloy, and other forms) still makes the facility a unique national resource for research and development activities involving the use of SNM. Recently INL has utilized this facility to serve as a test and evaluation facility for active interrogation research and development. This facility is currently hosting scoping experiments using neutron and x-ray radiation sources to characterize SNM active interrogation signatures and to develop tools and techniques to detect and identify shielded SNM. This paper presents an overview of the facility’s infrastructure and assets and describes recent active interrogation experiments that have taken place using high-energy x-ray sources and compact electronic neutron generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗