Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Transport Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

MCNP 6.2.0 Delayed-Particle Production Improvements

Development began on a delayed-particle physics package for the Monte Carlo Radiation transport code MCNPX in 2004 incorporating the CINDER90 depletion code and delayed particle libraries. When MCNP5 was merged with MCNPX to form MCNP6 in 2010, this delayed-particle capability was passed on and has been continuously improved in subsequent versions of MCNP6. Today, the delayed-particle feature in MCNP6 allows for the production of delayed neutrons, gammas, betas, and alpha particles. Future development includes the addition of delayed-positron production in the next release of MCNP6. Delayed particles can be sampled with MCNP using the ACT card in conjunction with the FISSION and NONFISS keywords. The user can specify one or more of the four available delayed-particle types mentioned above on one or both of the FISSION and NONFISS keywords. If a delayed-particle type is selected on the FISSION keyword, then delayed production of that particle from fission products and their progeny will be produced. Likewise, if a delayed-particle type is selected on the NONFISS keyword then delayed production of that particle from non-fission interactions and spontaneous decay will be produced. In some cases, the sheer number of delayed particles that can be produced from nuclear reactions and spontaneous decay (i.e. hundreds of delayed gamma lines when spontaneous fission is possible) can make it difficult to achieve converged solutions in an efficient and timely manner. Truncation methods are the simplest form of variance reduction and can be used to decrease convergence times by limiting calculations to the phase space of interest. This paper introduces several such truncation methods that allow the user to restrict the number of possible delayed particles available for sampling to only those of interest in the problem. It is important to stress that the use of any truncation method should be verified by first assessing the impact of the truncated particles (i.e. by disabling the truncation) for one or more baseline cases. In addition to these new methods, a new delayed-gamma sampling algorithm implemented in MCNP 6.2.0 is introduced. Comparisons to ENDF data and analytical benchmarking with the new algorithm show a substantial improvement in accuracy over previous versions. New improvements to the delayed-particle capability have been added to MCNP 6.2.0. These improvements include an updated treatment of the THRESH keyword which omits delayed-particle lines below a set amplitude, and addition of the PECUT and HLCUT keywords which allow the user to truncate delayed-particles lines based on energy and half-life, respectively. The delayed-gamma sampling algorithm has also been improved to allow exact energy sampling. Comparisons of MCNP calculations directly to ENDF data and analytical benchmarks have verified the significant improvement in the new delayed gamma sampling algorithm. (authors)

97 MATHEMATICS AND COMPUTING↗

SU-F-T-49: Dosimetry Parameters and TPS Commissioning for the CivaSheet Directional Pd-103 Brachytherapy Source

Purpose: The CivaSheet is a new LDR Pd-103 brachytherapy device offering directional-radiation for preferentially irradiating malignancies with healthy-tissue sparing. Observations are presented on dosimetric characterization, TPS commissioning, and evaluation of the dosesuperposition- principle for summing individual elements comprising a planar CivaSheet Methods: The CivaSheet comprises individual sources (CivaDots, 0.05cm thick and 0.25cm diam.) inside a flexible bioabsorbable substrate with a 0.8cm center-to-center rectangular array. All non-radioactive components were measured to ensure accuracy of manufacturer-provided dimensional information. The Pd spatial distribution was gleaned from radioactive and inert samples, then modeled with the MCNP6 radiation-transport-code. A 6×6 array CivaSheet was modeled to evaluate the dose superposition principle for treatment planning. Air-kerma-strength was estimated using the NIST WAFAC geometry. Absorbed dose was estimated in water with polar sampling covering 0.05≤r≤15cm in 0.05cm increments and 0°≤θ≤180° in 1° increments. These data were entered into VariSeed9.0 and tested for the dose-superposition-principle. Results: The dose-rate-constant was 0.579 cGy/h/U with g(r) determined along the rotational-axis of symmetry (0°) instead of 90°. gP(r) values at 0.1, 0.5, 2, 5, and 10cm were 1.884, 1.344, 0.558, 0.088, and 0.0046. F(r,θ) decreased between 0° and 180° by factors of 270, 23, and 5.1 at 0.1, 1, and 10cm. The highest dose-gradient was at 92°, changing by a factor of 3 within 1° due to Au-foil shielding. TPS commissioning from 0.1≤r≤11cm and 0°≤θ≤180° demonstrated 2% reproducibility of input data except at the high-dose-gradient where interpolations caused 3% differences. Dose superposition of CivaDots replicated a multi-source CivaSheet array within 2% except where another CivaDot was present. Following implantation, the device is not perfectly planar. TPS accuracy utilizing the dose-superposition-principle through geometric repositioning of CivaDots supersedes TPS limitations of intersource shielding effects Conclusion: Dosimetric characterization, source commissioning, and evaluation of the dose-superposition-principle with VariSeed9.0 permits treatment planning for the CivaSheet brachytherapy device. Research supported in part by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

Algorithms Performance Investigation of a Generalized Spreader-Bar Detection System

A “generic” gantry-crane-mounted spreader bar detector has been simulated in the Monte-Carlo radiation transport code MCNP [1]. This model is intended to represent the largest realistically feasible number of detector crystals in a single gantry-crane model intended to sit atop an InterModal Cargo Container (IMCC). Detectors were chosen from among large commonly-available sodium iodide (NaI) crystal scintillators and spaced as evenly as is thought possible with a detector apparatus attached to a gantry crane. Several scenarios were simulated with this model, based on a single IMCC being moved between a ship’s deck or cargo hold and the dock. During measurement, the gantry crane will carry that IMCC through the air and lower it onto a receiving vehicle (e.g. a chassis or a bomb cart). The case of an IMCC being moved through the air from an unknown radiological environment to the ground is somewhat complex; for this initial study a single location was picked at which to simulate background. An HEU source based on earlier validated models was used, and placed at varying depths in a wood cargo. Many statistical realizations of these scenarios are constructed from simulations of the component spectra, simulated to have high statistics. The resultant data are analyzed with several different algorithms. The simulated data were evaluated by each algorithm, with a threshold set to a statistical-only false alarm probability of 0.001 and the resultant Minimum Detectable Amounts were generated for each Cargo depth possible within the IMCC. Using GADRAS as an anomaly detector provided the greatest detection sensitivity, and it is expected that an algorithm similar to this will be of great use to the detection of highly shielded sources.

97 MATHEMATICS AND COMPUTING↗

SU-F-19A-05: Experimental and Monte Carlo Characterization of the 1 Cm CivaString 103Pd Brachytherapy Source

Purpose: To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of the CivaString {sup 103}Pd brachytherapy source through measurements and Monte Carlo (MC) simulations. American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters were also determined for this source. Methods: The in-air azimuthal anisotropy of the source was measured with a NaI scintillation detector and simulated with the MCNP5 radiation transport code. Measured and simulated results were normalized to their respective mean values and compared. The TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function for this source were determined from LiF:Mg,Ti thermoluminescent dosimeter (TLD) measurements and MC simulations. The impact of {sup 103}Pd well-loading variability on the in-water dose distribution was investigated using MC simulations by comparing the dose distribution for a source model with four wells of equal strength to that for a source model with strengths increased by 1% for two of the four wells. Results: NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy showed that ≥95% of the normalized data were within 1.2% of the mean value. TLD measurements and MC simulations of the TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function agreed to within the experimental TLD uncertainties (k=2). MC simulations showed that a 1% variability in {sup 103}Pd well-loading resulted in changes of <0.1%, <0.1%, and <0.3% in the TG-43 dose-rate constant, radial dose distribution, and polar dose distribution, respectively. Conclusion: The CivaString source has a high degree of azimuthal symmetry as indicated by the NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy. TG-43 dosimetry parameters for this source were determined from TLD measurements and MC simulations. {sup 103}Pd well-loading variability results in minimal variations in the in-water dose distribution according to MC simulations. This work was partially supported by CivaTech Oncology, Inc. through an educational grant for Joshua Reed, John Micka, Wesley Culberson, and Larry DeWerd and through research support for Mark Rivard.

07 ISOTOPE AND RADIATION SOURCES↗

Genetic algorithm optimization of nuclear criticality experiment for reduction of intermediate-energy 239 Pu nuclear data uncertainties

Nuclear criticality experiments are conducted to investigate specific nuclear data important for safe handling and storage of fissile materials, reactor design and operation, and the validation of radiation transport codes. Incorrect or uncertain nuclear data can prohibitively impact operational safety limits, reactor licensing, and predictive simulation capability; therefore, integral measurements from criticality experiments are necessary and should be performed frequently. To maximize the impact of the integral measurements, it is important to consider experiment geometry, material selection, and component dimensions. When taking these considerations into account, the experiment design process becomes iterative and very time intensive. This work utilizes a genetic algorithm to efficiently explore potential nuclear criticality experiment designs for the Laboratory Directed Research & Development project PARADIGM (PARallel Approach of Differential and InteGral Measurements) at Los Alamos National Laboratory. In this paper, the building blocks of the genetic algorithm are discussed in detail, the genetic algorithm methodology is verified, and the genetic algorithm is used to produce three candidate experiment models for the final PARADIGM design. The three candidate models produced by the genetic algorithm consist of copper-reflected assemblies containing 14 repeating units of alumina, graphite, boron, and plutonium plates. Furthermore, in addition to the optimization results, final design considerations are also discussed for designs with a height and/or weight very close to or slightly above assembly machine operational limits.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Delayed-Gamma Energy Biasing with Exact Energy Sampling in MCNP 6.2.0

Characterization of delayed-particle signatures is of the utmost importance for detecting, identifying, and quantifying special nuclear material (SNM). Various non-destructive assay (NDA) techniques used in nuclear material safeguards rely on characteristic gamma-ray or neutron emissions to infer properties of a material. The all-particle, all-energy Monte-Carlo radiation transport code MCNP6 is capable of simulating delayed-particle signatures from SNM in addition to modeling the transport of emitted particles to a detector or other instrument. In some cases, NDA techniques require the measurement of low probability emissions from a given material. In physical scenarios, this problem can be bypassed by longer count-times or may be simply irrelevant due to the mass, and therefore the total activity, of the material being measured. However, when applying the Monte-Carlo method to such scenarios, sampling of low probability emissions requires a large number of histories to converge to a statistically acceptable solution. To address this issue, the delayed-neutron and gamma energy biasing feature was introduced in MCNP6 by H. Armstrong et al. in 2013 which allows the user to set up energy windows in which delayed-particle emission sampling can be adjusted. For delayed-gamma sampling, this biasing method was based on the bin-wise structure of gamma emission data for both the multi-bin gamma and line-emission sampling modes. Recent improvements have been made to the line-emission sampling algorithm which upgrade the previous mini-bin sampling treatment to an exact energy-line treatment. This upgrade was not compatible with the biasing method implemented by H. Armstrong et al. due to the sampled data no longer having a bin-wise structure in line-emission mode. For this reason the delayed-gamma energy biasing feature has been rewritten to support the exact line-sampling treatment. This paper provides a description of the delayed-gamma energy biasing (DGEB) feature in MCNP6 as well as results and discussion for a gamma-ray spectroscopy example used to demonstrate the biasing utility. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local Power Impact Experiment Design for a New Fuel Type for use in the Advanced Test Reactor

The Advanced Test Reactor (ATR), and complimentary zero-power ATR Critical (ATRC) reactor, located at Idaho National Labs (INL), are undergoing conversion from Highly Enriched Uranium (HEU) to Low Enriched Uranium (LEU). Both have a variety of testing locations that can receive large variations in flux due to its unique serpentine design, consisting of five lobes (see Figure 1). Initial criticality and power distribution throughout the core are controlled by core-external outer shim control cylinders (OSCCs). Distinct test loops allow for testing at specific temperatures, pressures, and irradiation conditions. The ATR is one of the key nuclear engineering research and testing facilities within the DOE National Laboratory Complex, and the ATRC supports its operation [1]. Currently, the Office of Material Management and Minimization (M3) within the National Nuclear Security Administration of the DOE is working to convert the remaining research reactors, including the ATR, from 93% HEU fuel to 19.75% LEU fuel (LEU) to support non-proliferation [2]. Extensive materials testing at INL and internationally has demonstrated that a high-density uranium molybdenum (U 10Mo) alloy can meet the performance requirements of the remaining high powered research reactors. However, there are many technical challenges to address before the conversion to LEU can be successful, including the accurate characterization of the reactor core physics with LEU fuel. Reactor physics safety evaluations currently use Monte Carlo for the 21st Century (MC21), a continuous-energy Monte Carlo radiation transport code [3]. Existing MC21 models of the ATR and ATRC cores have a validation basis for use in neutronics analyses with HEU fuel. The models are used to support safety analyses that include comparisons to the safety requirements for the reactors. However, the use of the LOWE element in the ATR and ATRC is not currently covered by the current model validation basis. To deploy the new fuel type, extensive computational reactor physics support is necessary to support the use of LOWE in the ATR and ATRC. Therefore, LOWE requires a rigorous validation basis, aligned with that of HEU fuel, that takes advantage of the existing software tools and processes currently used for the ATR and ATRC. The experiment to validate of the MC21 models for determining power, the Power Impact Validation Experiment, will consist of two flux runs in the ATRC, one with fully HEU loading and one with a single LOWE element. Both flux runs will be instrumented with 20 sets of azimuthal fission wires and 3 sets of axial fission wires, as shown in Figure 4. Standard flux run methodology will be used [4]. Power Impact Validation Experiment data will be compared against MC21 calculated data, both for absolute fission rate accuracy and to determine the relative change in fission rates between the two runs. The results of the Power Impact Validation Experiment and subsequent evaluations will provide the validation basis for MC21 for use with LOWE elements. Key features of the Power Impact Validation Experiment include: (1) Two flux runs to allow for LOWE perturbed measurements to be compared to already validated measurements taken from a full core of HEU fuel, (2) Optimization of instrumentation to balance analytical needs with practical considerations (e.g., limited time window to count beta particles from fission products), and (3) Standard ATRC core loading, including both driver positions and flux traps, to minimize cost while remaining representative of typical ATR core loading.

42 ENGINEERING↗

TRIPOLI-4{sup R} version 9 Shielding for the Shielding Community: Overview, Relevant Benchmarking for Shielding and Licensing Policy - Paper 49

This is a review paper of the Shielding only version of TRIPOLI-4. TRIPOLI-4 and TRIPOLI-4 S: TRIPOLI{sup R} represents a family of radiation transport codes using the Monte Carlo method (1,2). It has been continuously developed at CEA since the mid 60's. TRIPOLI-4{sup R}, being the fourth generation, has been developed starting from the mid 90's in C++. It tracks neutrons from 20 MeV down to 10{sup -5} eV, photons, electrons and positrons from 100 MeV to 1 keV, in 3D arbitrary geometries either in TRIPOLI{sup R} proprietary format or ROOT(4) format. It reads its continuous energy nuclear data from any evaluation in ENDF format, including but not limited to JEFF-3.1.1 and ENDF/BVII.0. It has various simulation modes, fixed-source (with or without fission), criticality, or both of them chained. A variety of tallies are available: averaged flux in a volume (track length and collision estimators), surface flux and current, point flux, reaction rates, deposited energy, dpa, pka, gamma spectroscopy, mesh tallies, tallies for criticality (k{sub eff}, beta eff, kinetic parameters). It provides the user with embedded response functions from IRDF and EAF as well. Several variance reduction techniques (3), including automated ones, make it particularly suitable to deep penetration problems (implicit capture, Russian roulette, exponential biasing with automatic estimation of the importance map). It may run in parallel, on single multi-core machines as well as heterogeneous networks of stations or massively parallel machines. It comes with productivity tools designed to speed-up the elaboration and verification of the input deck as well as the output analysis: 2D interactive display of geometry; 2D display of mesh tallies and collision sites; 3D input deck modeler; compatibility with ROOT tools to post-process TRIPOLI{sup R} outputs. Its V and V test base is made of more than 1000 internationally accepted benchmarks from ICSBEP and SINBAD (REPLICA, ASPIS, NESDIP) and covers all its application domains, including several shielding cases which will be detailed in the talk. TRIPOLI-4{sup R} is the reference Monte Carlo code for CEA, EDF, and also for AREVA for a number of applications. A 'Shielding-only' version has been designed to specifically answer the needs of the shielding community. It is distributed through the NEA Databank with a license for R and D, covering the fusion applications, whose terms are detailed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the feasibility of polyurethane based 3D dosimeters with optical CT for dosimetric verification of low energy photon brachytherapy seeds

Purpose: To investigate the feasibility of and challenges yet to be addressed to measure dose from low energy (effective energy <50 keV) brachytherapy sources (Pd-103, Cs-131, and I-125) using polyurethane based 3D dosimeters with optical CT. Methods: The authors' evaluation used the following sources: models 200 (Pd-103), CS-1 Rev2 (Cs-131), and 6711 (I-125). The authors used the Monte Carlo radiation transport code MCNP5, simulations with the ScanSim optical tomography simulation software, and experimental measurements with PRESAGE{sup ®} dosimeters/optical CT to investigate the following: (1) the water equivalency of conventional (density = 1.065 g/cm{sup 3}) and deformable (density = 1.02 g/cm{sup 3}) formulations of polyurethane dosimeters, (2) the scatter conditions necessary to achieve accurate dosimetry for low energy photon seeds, (3) the change in photon energy spectrum within the dosimeter as a function of distance from the source in order to determine potential energy sensitivity effects, (4) the optimal delivered dose to balance optical transmission (per projection) with signal to noise ratio in the reconstructed dose distribution, and (5) the magnitude and characteristics of artifacts due to the presence of a channel in the dosimeter. Monte Carlo simulations were performed using both conventional and deformable dosimeter formulations. For verification, 2.8 Gy at 1 cm was delivered in 92 h using an I-125 source to a PRESAGE{sup ®} dosimeter with conventional formulation and a central channel with 0.0425 cm radius for source placement. The dose distribution was reconstructed with 0.02 and 0.04 cm{sup 3} voxel size using the Duke midsized optical CT scanner (DMOS). Results: While the conventional formulation overattenuates dose from all three sources compared to water, the current deformable formulation has nearly water equivalent attenuation properties for Cs-131 and I-125, while underattenuating for Pd-103. The energy spectrum of each source is relatively stable within the first 5 cm especially for I-125. The inherent assumption of radial symmetry in the TG43 geometry leads to a linear increase in sample points within the 3D dosimeter as a function of distance away from the source, which partially offsets the decreasing signal. Simulations of dose reconstruction using optical CT showed the feasibility of reconstructing dose out to a radius of 10 cm without saturating projection images using an optimal dose and high dynamic range scanning; the simulations also predicted that reconstruction artifacts at the channel surface due to a small discrepancy in refractive index should be negligible. Agreement of the measured with calculated radial dose function for I-125 was within 5% between 0.3 and 2.5 cm from the source, and the median difference of measured from calculated anisotropy function was within 5% between 0.3 and 2.0 cm from the source. Conclusions: 3D dosimetry using polyurethane dosimeters with optical CT looks to be a promising application to verify dosimetric distributions surrounding low energy brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

Utilization of ACE nuclear data file toolkit ACEtk to calculate relative sensitivity coefficients of point-kinetics parameters

Sensitivity and uncertainty methods are quintessential for nuclear criticality safety and experiment design. This type of analysis relies on calculations of sensitivity coefficients; sensitivity coefficients of the effective neutron multiplication factor with respect to some nuclear data are predominantly calculated and used. As a part of the Laboratory Directed Research & Development project EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) at Los Alamos National Laboratory, sensitivity coefficients of many radiation detector measurement responses with respect to nuclear data were investigated. Specifically, this paper outlines a method to calculate point-kinetics parameters relative sensitivity coefficients with respect to nuclear data. Point-kinetics parameters such as the prompt neutron decay constant, effective delayed neutron fraction, and neutron generation time are especially important to experimenters and reactor operators designing systems with dynamic neutron populations. This method couples capabilities of the ACE (A Compact ENDF) nuclear data file toolkit, ACEtk, with the ability to load cross sections into the radiation transport code Monte Carlo N-Particle (MCNP). In conclusion, key aspects of optimizing this method for a particular application and sensitivity profiles of the Jezebel criticality experiment are examined and discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Multigrid in energy preconditioner for Krylov solvers

We have added a new multigrid in energy (MGE) preconditioner to the Denovo discrete-ordinates radiation transport code. This preconditioner takes advantage of a new multilevel parallel decomposition. A multigroup Krylov subspace iterative solver that is decomposed in energy as well as space-angle forms the backbone of the transport solves in Denovo. The space-angle-energy decomposition facilitates scaling to hundreds of thousands of cores. The multigrid in energy preconditioner scales well in the energy dimension and significantly reduces the number of Krylov iterations required for convergence. This preconditioner is well-suited for use with advanced eigenvalue solvers such as Rayleigh Quotient Iteration and Arnoldi.

97 MATHEMATICS AND COMPUTING↗

Excited State Electronic Properties of Sodium Iodide and Cesium Iodide

We compute from first principles the dielectric function, loss function, lifetime and scattering rate of quasiparticles due to electronic losses, and secondary particle spectrum due to plasmon decay in two scintillating alkali halides, sodium iodide and cesium iodide. Particular emphasis is placed on quasiparticles within several multiples of the band gap from the band edges. A theory for the decay spectra of plasmons and other electronic excitations in crystals is presented. Applications to Monte Carlo radiation transport codes are discussed.

Campbell, Luke W↗

Observation and modeling of inner divertor re-attachment in discharges with lithium coatings in NSTX

In the National Spherical Torus Experiment (NSTX), modifications to the inner divertor plasma regimes are observed in high triangularity, H-mode, NBI heated discharges due to lithium coatings evaporated on the plasma facing components. In particular, the drop in the recombination rate, the reduced neutral pressure and the reduced electron density (inferred from Stark broadening measurements of high-n deuterium Balmer lines) suggested that the inner divertor, which is usually detached in discharges without lithium, re-attached. In conclusion, experimental results are compared to simulations obtained with a 1D partially ionized plasma transport model integrated in the non-local thermodynamic equilibrium radiation transport code CRETIN to understand how the reduced recycling affects the divertor parameters in NSTX discharges with lithium coatings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multilevel acceleration of scattering-source iterations with application to electron transport

Acceleration/preconditioning strategies available in the SCEPTRE radiation transport code are described. A flexible transport synthetic acceleration (TSA) algorithm that uses a low-order discrete-ordinates (S N ) or spherical-harmonics (P N ) solve to accelerate convergence of a high-order S N source-iteration (SI) solve is described. Convergence of the low-order solves can be further accelerated by applying off-the-shelf incomplete-factorization or algebraic-multigrid methods. Also available is an algorithm that uses a generalized minimum residual (GMRES) iterative method rather than SI for convergence, using a parallel sweep-based solver to build up a Krylov subspace. TSA has been applied as a preconditioner to accelerate the convergence of the GMRES iterations. The methods are applied to several problems involving electron transport and problems with artificial cross sections with large scattering ratios. These methods were compared and evaluated by considering material discontinuities and scattering anisotropy. Observed accelerations obtained are highly problem dependent, but speedup factors around 10 have been observed in typical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed modeling of fission with F R E Y A

For many years, the state of the art for treating fission in radiation transport codes has involved sampling from average distributions. However, such “average” fission models have limited interaction-by-interaction capabilities. Energy is not explicitly conserved and no correlations are available because all particles are emitted isotropically and independently. However, in a true fission event, the energies, momenta and multiplicities of emitted particles are correlated. Such correlations are interesting for many modern applications, including detector development and detection of small amounts of special material. Recently, several Monte Carlo codes have become available that calculate complete fission events. Event-by-event techniques are particularly useful because it is possible to obtain the fission products as well as the prompt neutrons and photons emitted during an individual fission process, all with complete kinematic information. It is therefore possible to extract any desired correlation observables. Such codes, when included in broader Monte Carlo transport codes, such as MCNP, can be made broadly available to the community. One such code, FREYA (Fission Reaction Event Yield Algorithm), is particularly fast and can readily generate large samples of complete fission events. We briefly describe here the physics in FREYA and compare our results with relevant available data on prompt neutron and photon emission. We discuss correlated measurements in particular for validation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Startup Test Plan and Predictions for Highly Enriched Uranium to Low-Enriched Uranium Fuel Conversion at the University of Missouri Research Reactor

Nonpower reactors licensed by the U.S. Nuclear Regulatory Commission require a startup test plan as part of any facility modification to verify operability prior to resumption of operations. In order to support conversion of the University of Missouri Research Reactor from the use of highly enriched uranium to low-enriched uranium (LEU) fuel, a startup test plan has been devised to measure certain reactor physics parameters for the initial all-fresh LEU core licensing documentation that will be submitted. These parameters include the approach to critical, primary coolant void coefficient of reactivity, flux trap void coefficient of reactivity, determination of flux trap sample reactivity worth, radial and axial thermal neutron flux mapping, control blade worth calibration, primary and pool coolant temperature coefficient of reactivity, and flux mapping of experimental positions. Here, predictions for these parameters made using the Monte Carlo N-Particle Version 5 (MCNP5) radiation transport code are reported. These predictions will support the startup tests by providing a baseline set of expectations and additional insight into the performance of the LEU core.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Discovering Active Subspaces for High-Dimensional Computer Models

Dimension reduction techniques have long been an important topic in statistics, and active subspaces (AS) have received much attention this past decade in the computer experiments literature. The most common approach towards estimating the AS is to use Monte Carlo with numerical gradient evaluation. While sensible in some settings, this approach has obvious drawbacks. Recent research has demonstrated that active subspace calculations can be obtained in closed form, conditional on a Gaussian process (GP) surrogate, which can be limiting in high-dimensional settings for computational reasons. In this paper, we produce the relevant calculations for a more general case when the model of interest is a linear combination of tensor products. These general equations can be applied to the GP, recovering previous results as a special case, or applied to the models constructed by other regression techniques including multivariate adaptive regression splines (MARS). Furthermore, using a MARS surrogate has many advantages including improved scaling, better estimation of active subspaces in high dimensions and the ability to handle a large number of prior distributions in closed form. In one real-world example, we obtain the active subspace of a radiation-transport code with 240 inputs and 9,372 model runs in under half an hour.

97 MATHEMATICS AND COMPUTING↗

Exploration of the Transition from the Hydrodynamic-like to the Strongly Kinetic Regime in Shock-Driven Implosions

Clear evidence of the transition from hydrodynamiclike to strongly kinetic shock-driven implosions is, for the first time, revealed and quantitatively assessed. Implosions with a range of initial equimolar D 3 He gas densities show that as the density is decreased, hydrodynamic simulations strongly diverge from and increasingly over-predict the observed nuclear yields, from a factor of ~2 at 3.1 mg/cm 3 to a factor of 100 at 0.14 mg/cm 3 . (The corresponding Knudsen number, the ratio of ion mean-free path to minimum shell radius, varied from 0.3 to 9; similarly, the ratio of fusion burn duration to ion diffusion time, another figure of merit of kinetic effects, varied from 0.3 to 14.) This result is shown to be unrelated to the effects of hydrodynamic mix. As a first step to garner insight into this transition, a reduced ion kinetic (RIK) model that includes gradient-diffusion and loss-term approximations to several transport processes was implemented within the framework of a one-dimensional radiation-transport code. After empirical calibration, the RIK simulations reproduce the observed yield trends, largely as a result of ion diffusion and the depletion of the reacting tail ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗