Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiological”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Laser-Induced Plasmas of Plutonium Dioxide in a Double-Walled Cell

Plutonium research has been stifled by the significant number of administrative controls and safety procedures, space and instrumentation limitations in radiological gloveboxes, and the potential for personnel and equipment contamination. To address the limited number of spectroscopic studies in Pu-bearing compounds in the current scientific literature, this work presents the use of double-walled cells (DWCs) in “clean” buildings/laboratories as an alternative to research in radiological gloveboxes. This study reports the first laser-induced breakdown spectroscopy (LIBS) experiments of a PuO 2 pellet contained within a DWC, where the formation of elemental (atomic and ionic) species as well as the evolution from elemental to molecular products (Pu x O y ) was measured. Raman spectroscopy was also used to characterize the surface of the ablated pellet and the particulates deposited on the window of the inner cell. The full width half-maximum of the T 2g band enabled us to obtain an estimate of the temperature at the pellet surface after the ablation pulse and the particulates based on the crystal lattice disorder. Particulates deposited on the window of the DWC during laser ablation were characterized using scanning electron microscopy, where molten irregular particulates and spheroids were observed. This exciting research conducted in a DWC describes our initial attempts to incorporate LIBS in the arsenal of spectroscopic tools for nuclear forensics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AMS / BARC Joint Survey (Summary Report)

Report describes a series of joint aerial radiation survey flights at various locations in Southern Nevada and Colorado performed by AMS and BARC (U.S. and India). The flights were conducted over areas of well-characterized natural background in Nevada, at the Large-Area Calibration Pads at Grand Junction, CO, and over real ground contamination at the Nevada National Security Site. The intention of the joint surveys was to compare the responses, processes, and procedures of each country’s aerial radiation detection system. These systems can detect and map ground contamination that may result from a nuclear or radiological accident or incident, and play a significant role in the national radiological emergency response capabilities of both countries.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radiation Mapping UAV [Poster]

The NuMI (Neutrinos at the Main Injector) target system delivers a high-energy flux of muon-neutrinos towards a detector more than 800 km away with the goal of better understanding the origin of the universe and its evolution. The target system becomes radioactive because it is irradiated by a sub-Mega-Watt power proton beam. Radiological hazard is one of critical issues for a radiological worker which limits the iractivities near the target system; however, they often need to quantify the radiation level of the target system manually. Thus, the objective of this project is to reduce their exposure to radiation while improving the accuracy of the measurements. A quadcopter UAV fitted with a radiation dosimeter is ideal to traverse the irradiated environment as it can be deployed in any space and requires minimal hardware integration to the test room. Due to the lack of indoor GPS signal, this UAV utilizes a series of ultrasonic beacons that release several varied-frequency pulses simultaneously in order to localize the drone. The flight controller returns a 3D coordinate tied to the radiation data to understand precisely where radiation spikes are being emitted from the horn. The flight controller stores log data that can be processed into an easily interpretable map of radiation intensities. The radiation map serves as one of the primary references for planning the transportation of the NuMI horn.

43 PARTICLE ACCELERATORS↗

Composite Analysis Solid Waste Release Data Reduction of Activity Flux from Waste Sites to the Vadose Zone for Baseline Assessment

This environmental calculation file (ECF) describes the data reduction methodology for the solid waste release datasets generated by the Composite Analysis Solid Waste Release (CASWR) model (CP-62766, Model Package Report: Composite Analysis Solid Waste Release Model [CASWR Model]) and documents the resulting reduced datasets for the updated Composite Analysis (CA) baseline assessment. This ECF is in support of the updated Hanford Site CA. The purpose of the updated Hanford Site CA is to provide an estimate of the cumulative radiological impacts from active and planned low-level radioactive waste disposals and other potentially interacting radioactive waste disposal sources that will remain following Hanford Site closure. The vadose zone modeling activities associated with the CA includes solid waste forms as contaminant sources. To support the modeling of solid waste transport from the vadose zone to the groundwater at the Hanford Site, the CASWR model was designed to generate deterministic radionuclide release rates for the Hanford Site Central Plateau solid waste disposal sites. The complete CASWR model-generated dataset for the CA Baseline Assessment consists of 2,378,831 sets of time and release rates (1,073,869 sets for the 200 East Area and 1,304,962 sets for the 200 West Area), representing a course of the simulation from year 1953 to year 12,069, 16 radiological contaminants of potential concern (COPCs), and 237 solid waste sources as documented in ECFHANFORD- 19-0112, Solid Waste Release Calculations for the Composite Analysis Baseline Assessment. For several of the STOMP vadose zone models, the number of release rate data pairs required for release at all waste sites would exceed the limitations imposed by the STOMP modelling software package used to simulate contaminant transport through the vadose zone. As a result, a data reduction of the CASWR dataset is required prior to its use as a source input for the CA vadose zone modeling activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Default Radioactive and Hazardous Waste Management (RHWM) Dose Conversion Factors (DCFs) and Weighting Factors and plutonium-239 equivalent Curie (PE-Ci) methodology for acceptance into the Waste Storage Facilities

DOE-STD-5506-2007 (Ref. 1) is the standard that provides the methodology for preparing hazard analysis and accident analysis for transuranic (TRU) waste facilities. The Waste Storage Facilities hazard and accident analysis for the DSA is developed in accordance with DOE-STD- 5506-2007. Two related issues need to be addressed when implementing DOE-STD-5506-2007 regarding the calculation of consequences from TRU waste releases in accident analysis: Consequences determined in accident analysis must be modeled using inhalation Dose Conversion Factors (DCFs) that are consistent with those from the International Commission on Radiological Protection Publication 72 (ICRP-72, Ref. 2).; The use of a statistical Material at Risk (MAR) representing the distribution of radiological loading of TRU waste containers based on the use of a plutonium-239 equivalent Curie (PE-Ci) methodology. The PE-Ci methodology simplifies accident analysis by allowing one to model releases based on the Curie value of one standard nuclide (e.g., Pu-239) instead of needing to model releases for every potential nuclide of interest. This is accomplished by normalizing the Curie value of all nuclides to a single Curie value of a standard nuclide by using a Weighting Factor that is a ratio of the DCFs associated with the nuclides and that of the standard nuclide. By using the ICRP-72 DCFs to calculate PE-Ci values used in the statistical MAR, the accident analysis that uses that statistical MAR will be consistent with the consequence methodology identified in DOE-STD- 5506-2007.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford Site Composite Analysis Data Package: Exposure Scenarios and Radionuclide Specific Dose Conversion Factors

This data package summarizes the exposure assumptions, equations, and methods used to calculate radionuclide-specific unit dose factors and the radiological doses for both groundwater and atmospheric pathways as a part of the updated Hanford Site Composite Analysis (CA). An All Pathways Representative Person exposure scenario is considered to evaluate exposure via both groundwater and atmospheric transport pathways. The radiological dose assessments for both groundwater and atmospheric pathways are included in the performance assessments (PAs) for various Waste Management Areas at the Hanford Site. This data package calculates exposure route-specific and total unit dose factors for CA-specific radionuclides of concern based on the exposure assumptions used in the CA and PAs. This data package also presents the results and comparison of the radionuclide-specific unit dose factors based on the exposure assumptions used in the revised Hanford Site Composite Analysis and Hanford Site performance assessments for low-level waste disposal facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Distribution of Infiltration in the 216-U-10 and 216-B-3 Pond Systems 1944-1997

A modeling system to simulate fate and transport of contaminant plumes in groundwater beneath the Central Plateau to support the Cumulative Impact Evaluation (CIE) and Composite Analysis (CA) is being developed. The CIE will evaluate the cumulative effect of multiple Central Plateau radiological and chemical sources on groundwater quality (DOE/RL-2018-69, Cumulative Impact Evaluation Technical Approach Document ). This will enable cleanup decisions to be evaluated in the context of all Central Plateau waste sites and existing groundwater conditions. The CA evaluates the cumulative effect of all sources of radioactive materials on radiological dose to future members of the public (DOE/RL-2018-60, Annual Status Report (FY 2018): Composite Analysis of Low Level Waste Disposal in the Central Plateau of the Hanford Site ). Fate and transport modeling will be used to forecast future groundwater concentrations for both the CIE and CA. The CIE/CA subsurface modeling system is divided into source (inventory), vadose zone, and saturated zone facets. Source inventory is a necessary input to the vadose zone facet, and releases from the vadose zone to groundwater are inputs to the saturated zone facet. The vadose zone facet simulates historical and future releases from the vadose zone to groundwater for both liquid waste and solid waste disposal sites. Effluent release volumes and radionuclide inventory estimates for liquid waste sites are contained in ECFHANFORD- 17-0079, Hanford Soil Inventory Model (SIM-v2) Calculated Radionuclide Inventory of Direct Liquid Discharges to Soil in the Hanford Site’s 200 Areas , herein referred to as SIM-v2. The liquid waste sites in SIM-v2 include the 216-B-3 Pond near 200 East Area and the 216-U-10 Pond in 200 West Area. The 216-B-3 Pond system consisted of a main pond and 3 expansion lobes that were operational during overlapping time periods. It also included influent ditches, but these are not listed as liquid waste sources in SIM-v2 and are not included in the CIE/CA modeling. The total effluent volume released to the pond system was measured, but the partitioning of this volume to the various expansion lobes was not determined and is not accounted for in SIM-v2. Regarding the 216-U-10 Pond, it received water from several influent ditches. The pond and the influent ditches are listed as liquid waste sites in SIM-v2 and are included as sources in the CIE/CA modeling. Because water in the ditches flowed into the pond, only a portion of the effluent volumes and contaminant inventories assigned to the ditches in SIM-v2 infiltrated from the ditches. Thus, partitioning of infiltration and contaminant inventories between the ditches and the pond is not fully accounted for in SIM-v2. Further, some of the water in the 216-U-10 Pond entered overflow ditches and the amount of this overflow was not recorded and is not accounted for in SIM-v2. Thus, the purpose of this Environmental Calculation File (ECF) is to partition the infiltration of wastewater and contaminant inventory between the main pond and each expansion lobe of the 216-B-3 Pond system, and to partition the infiltration of wastewater and contaminant inventory between the ditches and pond of the 216-U-10 Pond system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modernization of Technical Requirements for Licensing of Advanced Non-Light Water Reactors: Risk-Informed and Performance-Based Evaluation of Defense-in-Depth Adequacy

This document supports the work contained in Nuclear Energy Institute (NEI) 18-04 “Risk-Informed Performance-Based Technology Inclusive Guidance for Advanced Reactor Licensing Basis Development” Revision 0. NEI 18-04 presents a modern, technology-inclusive, risk-informed, and performance-based (TI-RIPB) process for selection of Licensing Basis Events (LBEs); safety classification of structures, systems, and components (SSCs) and associated risk-informed special treatments; and determination of defense-in-depth (DID) adequacy for non-LWRs. The NEI guidance document provides one acceptable means for addressing the aforementioned topics as part of demonstrating a specific design provides reasonable assurance of adequate radiological protection. This report provides the framework and associated methodology guidelines and discussion for establishing, then evaluating, confirming, and documenting the adequacy of defense-in-depth (DID) for advanced non-light-water reactor technologies. It was developed as part of the Licensing Modernization Project led by Southern Company and cost-shared by the United States Department of Energy and has benefited from considerable NRC formal reviews and public workshops. The methodology converts the DID philosophy into a structured process that is implementable, embraces existing United States and international definitions and philosophies of DID that set the foundation for the process. It builds on the DID framework developed in the Department of Energy Next Generation Nuclear Plant Project and earlier works on this subject. The approach to establishing DID adequacy involves the incorporation of DID attributes into the plant capabilities and programmatic elements of DID. The integrated evaluation of DID adequacy includes both quantitative elements to incorporate risk-informed and performance-based (RIPB) considerations and qualitative elements that address uncertainties and limitations in the quantitative models and supporting data. Demonstration of DID adequacy ensures that there are multiple layers of defense for risk-significant challenges to the design and that the plant capabilities and programs that support each layer are provided in a manner that minimizes dependencies among these layers. The focus of this report is assurance of DID adequacy with respect to protection of the public from radiological exposures resulting from accidental releases of radioactive material. While other hazards are not specifically addressed, this methodology is expected to be beneficial for determining DID adequacy for them as well. Risk-informed evaluation of DID considers the integrated performance of all plant SSCs and associated programs to manage daily operational activities, transients, and accidents, including the evaluation of strategies for accident prevention and mitigation. The RIPB LBE scenario methodology used in this evaluation defines the challenges to the plant safety features included in the plant design basis and beyond, and the scope of all deterministic and probabilistic safety evaluations. By examining event sequences across the whole spectrum of LBEs, a systematic assessment of DID can be accomplished.

42 ENGINEERING↗

Operational and Mission Highlights A Monthly Summary of Top Achievements

In September 2020, the Laboratory’s Chemical Microscopy Facility tripled in size, expanding to 1,000 square feet. Located at TA-46, Building158, this facility houses a unique Laboratory resource. Operated by the Physical Chemistry and Applied Spectroscopy (C-PCS) group, this facility was established to renew the Laboratory’s rich history in radiobiology. The facility combines biological research capabilities with isotope production, as well as radioanalytical and chemical infrastructure. This facility provides space for Biosafety Level 2 (BSL-2) research, with alpha-emitting and other radionuclides of interest associated with biological systems. Equipped with a Class ll/A2 biological safety cabinet, a radiological fume hood and a host of other analytical equipment, this facility serves an effective resource to evaluate the efficacy of targeted alpha therapeutics, as well as the deleterious effects of radiological materials on living organisms. The facility receives funding through LDRD- 20180005DR, “Establishing a Radiotherapeutic Capability to Counter Biothreats,” and the BES Heavy Element Chemistry Program at the Laboratory.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

NNSA-IAEC Science and Technology Working Group Area V - Waste Management and Subsurface Science, (Q1 FY2021)

The objective of Topic Area V is to evaluate the feasibility and safety of an intermediate-depth borehole for disposal of IAEC nuclear waste. The IAEC nuclear waste is currently stored in above ground and/or in near-surface facilities that provide short-term radiological worker safety but do not provide long-term, full security and safeguards protection for the nuclear material. Disposal of the IAEC nuclear waste several hundred meters below the surface in a sealed borehole would provide long-term security and safeguards due to its depth underground, as well as long-term radiological safety, due to its isolation in a stable geological formation.

54 ENVIRONMENTAL SCIENCES↗

HPAC Validation against NRC Documentation

This report describes validation of the radiological source terms in the Nuclear Facility Accident (NFAC) module of the Defense Threat Reduction Agency (DTRA)’s Hazard Prediction and Assessment Capability (HPAC) software. The validation will be conducted by comparing the source terms defined in HPAC to published data from references approved by the U. S. Nuclear Regulatory Commission (NRC). Comparisons will be done for both pressurized water reactors (PWRs) and boiling water reactors (BWRs). This comparison includes the magnitude, isotopic composition, and timing of the release fractions over the course of a severe or moderate accident. Calculations for both facility-specific nuclear power plants and for more generic reactor categories are involved. It is shown that the NFAC radiological source terms in HPAC agree well with NRC standards for moderate and severe accidents at PWRs and BWRs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

TCR Postulated Accident and MHA Dose Assessment

Oak Ridge National Laboratory (ORNL) is engaged in regulatory activities to gain US Department of Energy (DOE) approval to build and operate a small high-temperature gas reactor, the Transformational Challenge Reactor (TCR). ORNL uses advanced manufacturing techniques to produce select reactor components. The TCR is unique in its mission: the reactor’s at-power operating lifetime will be less than one effective full-power day to limit the radiological source term to very low values, thus facilitating approval to operate. The primary regulatory documents governing construction and operation of the facility are NUREG-1537, “Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors” and DOE-STD-3009, “Preparation of Nonreactor Nuclear Facility Documented Safety Analysis.” Although this document is not a safety basis document, it provides a conservative indication of the magnitude of onsite and offsite radiological doses for specific scenarios, thus informing future design and regulatory activities. As required by NUREG-1537, scenarios included in this analysis are (1) a worstcase depressurized loss-of-forced-circulation accident, and (2) a maximum hypothetical accident. Details on the analysis of dose consequences with various system configurations are also provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dosimeter Area Monitoring Program (DAMP) Technical Basis Document

This document provides a technical basis for establishing a Dosimetry-based Area Monitoring Program (DAMP) at Lawrence Livermore National Laboratory (LLNL). A DAMP is part of a comprehensive routine monitoring program and provides information about radiation levels inside and outside of Radiologically-Controlled Areas (RCAs). The routine, hand-held radiation survey program driven by the Health Physics Discipline Action Plan (HP-DAP) helps to ensure radiological conditions within RCAs are well-characterized and routinely monitored; however, such surveys are a snapshot in time, whereas area monitoring dosimeters (AMDs) continuously monitor radiation doses in the areas where they are installed. Together, data from the hand-held radiation surveys and the DAMP provides a comprehensive picture of radiation environment at LLNL. A DAMP helps to verify the effectiveness of established engineered and administrative controls while documenting that radiation doses in RCAs are below that which requires individual monitoring. This document establishes the basis for determining which model of dosimeter to use, the exchange frequency, the occupancy factor, monitoring locations, and a method for evaluating AMD results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative Assessment of Data-driven Process Models in Health Information Technology

Process mining for conformance analysis consists of comparing a reference process model against a data-driven process model generated via log files from information technology systems. However, in the absence of a complete reference process model, we found no suggested approaches in the literature to address the need for evaluating process conformance among different healthcare facilities to assess standardization of care. Our goal is to find similarities and dissimilarities in data-driven process models among US Veterans Health Administration (VHA) facilities that can be indicative of patient safety issues. Our hypothesis was that the analysis would not produce statistically significant differences in outcome. We present a unique implementation of conformance analysis in process mining that consists of combining process mining, process mapping and statistical metrics. We illustrate our approach by applying it to the analysis of two clinical radiology order process models generated from healthcare data provided by two similar facilities in the VHA. The comparative assessment showed that about 70% of the orders completed successfully and 30% were not completed due to policy and duplications. Our analysis found a good statistical correlation between both facilities, as the Spearman’s correlation coefficient between facilities for the frequency of cases per total hours was 0.87879, for the frequency of cases by state transition was 0.79702 and for the throughput time per state transition was 0.63582. Additional statistical analyses using the Mann-Whitney U test and the root mean square error both produced values that were not significant. The foregoing approach validated our hypothesis by demonstrating a good statistical correlation of data describing the flow of clinical radiology orders absent a credible reference model. Finding good agreement between both facilities was important in confirming that the clinical orders flow in a similar manner, suggesting standardization of care.

97 MATHEMATICS AND COMPUTING↗

Application of Shift Ex-Core Calculations to a Detailed MSR Model

This report documents the collaborative research conducted between Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL) on applying the Monte Carlo neutronics code Shift to calculate the radiation dose rates for a detailed molten salt reactor (MSR) model based on the Molten Salt Breeder Reactor (MSBR). In this work scope, the ANL and ORNL teams worked together and applied Shift to calculate the radiological environments of this detailed MSR facility modeled with explicit geometries. The radiological conditions within the MSR facility were modeled for when the reactor is at two different operation modes: normal full power and drained state. The FW-CADIS hybrid method in Shift was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Dose rate maps showed that in the current MSBR numerical model, potential pathways exist for neutrons and gammas to stream through the 8-foot concrete shield to reach the top of the MSBR reactor cell. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the Shift simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates, which suggests that a steel liner in the tank model must be added for calculating the dose rates in the drain cell.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

LANL MLU TRUPACT Loading Survey Document

The following SNL document contains requested radiological survey information, as part of the documentation for the MLU shipment being performed by the LANL MLU team. The survey was performed in TA-5, on October 19th, 2021. This survey was for radiological coverage for the disassembly of two TRUPACTs, the assembly and loading of their payloads, and the reassembly of the TRUPACTs.

61 RADIATION PROTECTION AND DOSIMETRY↗