Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Synthesis, characterization and TL response of Ce{sup 3+} activated BaMgAl{sub 10}O{sub 17} phosphor

Phosphor material BaMgAl{sub 10}O{sub 17} with varying concentration of rare earth Ce{sup 3+} synthesis by combustion method at 500°C. The synthesized phosphor material characterized for their crystallinity and nature by XRD measurements. The thermoluminescecne response of phosphor exhibit TL spectra at 204°c and detailed analysis of kinetic parameter by de convoluted curve. These results show that concentration quenching occur at 5mol% of Ce dopant. The results suggest the possibility of utilizing as a phosphor may be in UV dosimeter and solid state lighting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Microcalorimeter Gamma-Detectors for High-Accuracy Nuclear Decay Data

Magnetic microcalorimeters (MMCs) are low-energy gamma-ray detectors with ultra-high energy resolution that are operated at temperatures below 50 mK. They use metallic Au absorbers and paramagnetic Ag:Er sensors to measure gamma-ray energies from an increase in detector temperature. Ultra-low temperatures are made accessible to non-expert users with “dry” dilution refrigerators that replace the traditional liquid N 2 and He pre-cooling with a mechanically cooled pulse-tube refrigerator. Our MMC gamma detectors have achieved an energy resolution below 40 eV FWHM at 60 keV, and they have a uniform and reproducible response function that allows adding spectra from different detector pixels without loss in energy resolution. These properties make MMCs well-suited to re-measure nuclear decay data with increased precision and smaller systematic errors to increase the accuracy of non-destructive assays (NDA). We present recent MMC gamma-ray spectra of Th-234 to show how MMCs can resolve lines that are relevant for NDA analysis and that overlap in Ge spectra. We also discuss the accuracy that MMCs can achieve for nuclear decay data with an emphasis on gamma-ray energies and intensity ratios that current NDA codes are based on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Impact of Changes in ENDF/B-VII.1 and ENDF/B-VIII.0 235U Nuclear Data Indicated by NDSE Studies on LLNL Pulsed Sphere Simulations

A recent journal article by J.A. Gomez et al. measured gamma-ray die-off curves of three subcritical static highly-enriched uranium (HEU) assemblies driven by an external neutron source with a new detector system. This new detector system was developed for being used in dynamically driven subcritical assemblies as part of the Neutron Diagnosed Subcritical Experiments (NDSE) program. Simulations of these die-off curves with various nuclear data and comparison to experimental data indicated that a decrease of the ENDF/B-VII.1 235 U(n,inl) cross section by a factor 0.8 and 0.85 for ENDF/B-VIII.0 would lead to better predictions of experimental data. Here, we test the proposed changes with another type of measurement response, namely neutron-leakage spectra emitted in LLNL pulsed sphere measurements. These spheres were pulsed by 14-MeV neutrons produced via the D+T reaction in their center. The proposed changes in nuclear data have a distinctly smaller impact on predicting pulsed-sphere neutron-leakage spectra than for the die-off curves; they lead to a worsened prediction of the inelastic valley of LLNL pulsed-sphere neutron spectra indicating that the proposed change could constitute a compensating error. Changes in the inelastic angular distributions along with the cross section might be worthwhile to study

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative comparisons of electron-scale turbulence measurements in NSTX via synthetic diagnostics for high-k scattering.

Two synthetic diagnostics are implemented for the high-k scattering system in NSTX [D. R. Smith, E. Mazzucato, W. Lee, H. K. Park, C. W. Domier, and N. C. Luhmann Jr., Rev. Sci. Instrum., 79, 123501 (2008)] allowing direct comparisons between synthetic and experimentally detected frequency and wavenumber spectra of electron-scale turbulence fluctuations. Synthetic diagnostics were formulated in real-space and in wavenumber space, and were deployed to realistic electron-scale simulations carried out with the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186 (2003) 545]. A highly unstable ETG regime (electron temperature gradient mode) in a modest beta NSTX NBI-heated H-mode discharge was chosen for the analysis. Mapping the measured wavenumbers to field aligned coordinates showed that the high-k system is sensitive to fluctuations that are closer to the spectral peak in the density fluctuation wavenumber spectrum (streamers) than originally predicted. Analysis of synthetic spectra show that the frequency response of the detected fluctuations is dominated by Doppler shift and insensitive to the turbulence drive. The shape of the high-k density fluctuation wavenumber spectrum is sensitive to the ETG turbulence drive conditions, and can be reproduced in a sensitivity scan of the most pertinent turbulent drive terms in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radar investigation of asteroids

The dual polarization CW radar system which permits simultaneous reception in the same rotational sense of circular polarization as transmitted (i.e., the "SC" sense) and in the opposite ("OC") sense, was used to observe five previously unobserved asteroids: 2 Pallas, 8 Flora, 22 Kalliope, 132 Aethra, and 471 Papagena. Echoes from Pallas and Flora were easily detected in the OC sense on each of several nights. Weighted mean echo power spectra also show marginally significant responses in the SC sense. An approximately 4.5 standard deviation signal was obtained for Aethra. The Doppler shift of the peak is about 10 Hz higher than that predicted from the a priori trial ephemeris. Calculations are performed to determine whether this frequency offset can be reconciled dynamically with optical positions reported for Aethra.

Ostro, S. J.↗

Spectroscopic investigation of Cr to Tm energy transfer in yttrium aluminum garnet crystals

A series of experiments has been conducted in order to examine the nature of the energy transfer process between the Cr(3+) and Tm(3+) ions in YAG. Data are obtained on various samples doped with Cr(3+) and/or Tm(3+). These data include absorption, luminescence, excitation spectra and time-resolved response to pulsed excitation. The measurements were carried out over a range of temperatures from 78 to 350 K. The rate of nonradiative energy transfer from Cr(3+) to Tm(3+) depends on temperature, and in the region from 200 to 350 K, this dependence is due primarily to the thermal variation in the radiative decay probability of the Cr ion.

Armagan, G.↗

A Unified Computational Model for Solar and Stellar Flares

We present a unified computational framework that can be used to describe impulsive flares on the Sun and on dMe stars. The models assume that the flare impulsive phase is caused by a beam of charged particles that is accelerated in the corona and propagates downward depositing energy and momentum along the way. This rapidly heats the lower stellar atmosphere causing it to explosively expand and dramatically brighten. Our models consist of flux tubes that extend from the sub-photosphere into the corona. We simulate how flare-accelerated charged particles propagate down one-dimensional flux tubes and heat the stellar atmosphere using the Fokker-Planck kinetic theory. Detailed radiative transfer is included so that model predictions can be directly compared with observations. The flux of flare-accelerated particles drives return currents which additionally heat the stellar atmosphere. These effects are also included in our models. We examine the impact of the flare-accelerated particle beams on model solar and dMe stellar atmospheres and perform parameter studies varying the injected particle energy spectra. We find the atmospheric response is strongly dependent on the accelerated particle cutoff energy and spectral index.

radiative transfer↗

Modeling the Proton Radiation Belt With Van Allen Probes Relativistic Electron-Proton Telescope Data

An empirical model of the proton radiation belt is constructed from data taken during 2013-2017 by the Relativistic Electron-Proton Telescopes on the Van Allen Probes satellites. The model intensity is a function of time, kinetic energy in the range 18-600 megaelectronvolts, equatorial pitch angle, and L shell of proton guiding centers. Data are selected, on the basis of energy deposits in each of the nine silicon detectors, to reduce background caused by hard proton energy spectra at low L. Instrument response functions are computed by Monte Carlo integration, using simulated proton paths through a simplified structural model, to account for energy loss in shielding material for protons outside the nominal field of view. Overlap of energy channels, their wide angular response, and changing satellite orientation require the model dependencies on all three independent variables be determined simultaneously. This is done by least squares minimization with a customized steepest descent algorithm. Model uncertainty accounts for statistical data error and systematic error in the simulated instrument response. A proton energy spectrum is also computed from data taken during the 8 January 2014 solar event, to illustrate methods for the simpler case of an isotropic and homogeneous model distribution. Radiation belt and solar proton results are compared to intensities computed with a simplified, on-axis response that can provide a good approximation under limited circumstances.

Selesnick, R. S.↗

Quantum efficiency, photoemission energy spectra, and mean transverse energy of ultrananocrystalline diamond photocathode

The quantum efficiency and mean transverse energy of electrons emitted from a cathode determine the quality of beams generated from photoinjectors. The nitrogen-incorporated ultrananocrystalline diamond, (N)UNCD, is a new class of robust semiconductor photocathodes, which has been considered in photoinjectors for high peak current extraction. In this work, we measure the spectral response in quantum efficiency, photoemission energy spectra, and mean transverse energy of the (N)UNCD photocathode using a photoemission electron microscope. The observed quantum efficiency was comparable to that of copper photocathodes. Photoemission spectra showed the evidence of scattering of electrons before emission. This relaxation of electrons due to scattering is also observed in the spectral response of the mean transverse energy. The mean transverse energy is limited to ∼70 meV at the threshold. We attribute this to the physical and chemical roughness of the (N)UNCD photocathode and, hence, smoother films will be required to further reduce the mean transverse energy obtained from the (N)UNCD photocathode.

Kachwala, A. (ORCID:0000000301756478)↗

Instrument Control Software for Spectrophotometers

SRNL has developed instrument control software for diode array spectrophotometers that can be used for real time monitoring of dynamic systems. This software has evolved through several iterations as instruments have been developed for use in processing facilities at Savannah River Site. There are several noteworthy features of the software. The wavelength calibration is checked and updated in real time against reference emission lines that are designed into the instrument light source. Nonlinearities and offsets associated with the intensity response of the instruments are characterized, and absorbance spectra are appropriately corrected. These actions are necessary for accurate calculation of an absorbance spectrum from the intensity responses of two individual diode array detectors. The corrections also result in the spectra obtained for a particular sample by two (or more) different diode array detector pairs being nearly identical. This property assures consistent measurements at multiple locations with different instruments. It also permits the use of a single analyte calibration across many instruments without modification and without loss of accuracy

47 OTHER INSTRUMENTATION↗

Quantum field theory of topological spin dynamics

Here, we develop a field theory of quantum magnets and magnetic (semi)metals, which is suitable for the analysis of their universal and topological properties. The systems of interest include collinear, coplanar, and general noncoplanar magnets. At the basic level, we describe the dynamics of magnetic moments using smooth vector fields in the continuum limit. Dzyaloshinskii-Moriya interaction is captured by a non-Abelian vector gauge field, and chiral spin couplings related to topological defects appear as higher-rank antisymmetric tensor gauge fields. We distinguish type-I and type-II magnets by their equilibrium response to the non-Abelian gauge flux, and characterize the resulting lattices of skyrmions and hedgehogs, the spectra of spin waves, and the chiral response to external perturbations. The general spin-orbit coupling of electrons is similarly described by non-Abelian gauge fields, including higher-rank tensors related to the electronic Berry flux. Itinerant electrons and local moments exchange their gauge fluxes through Kondo and Hund interactions. Hence, by utilizing gauge fields, this theory provides a unifying physical picture of “intrinsic” and “topological” anomalous Hall effects, spin-Hall effects, and other correlations between the topological properties of electrons and moments. We predict “topological” magnetoelectric effect in materials prone to hosting hedgehogs. Links to experiments and model calculations are provided by deriving the couplings and gauge fields from generic microscopic models, including the Hubbard model with spin-orbit interactions. Much of the formal analysis is generalized to d spatial dimensions in order to access the $π_{d–1}(S^{d–1})$ homotopy classification of the magnetic hedgehog topological defects, and establish the possibility of novel quantum spin liquids that exhibit a fractional magnetoelectric effect. However, we emphasize the form of all results in the physically relevant $\textit{d}$ = 3 dimensions, and discuss a few applications to topological magnetic conductors like Mn 3 Sn and Pr 2 Ir 2 O 7 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sound-producing dune and beach sands

Acoustic and seismic outputs of booming sands and singing (squeaking) sands in response to shearing are investigated, with samples of silent sands studied for controls. A vertical-axis geophone buried at shallow depth and an air microphone were used in the studies. The frequency spectra of the acoustic and seismic responses, propagation delays, comparison of acoustic and seismic traces, grain size and grain surface texture, particle morphology, coherent behavior of grains in assemblages, and relation to prevalent local winds were studied. Mechanisms are still obscure and disputed; slumping and avalanches were induced artificially in some studies. Existence of booming dune phenomena on Mars or on the moon is conjectured.

Lindsay, J. F.↗

An investigation of wing buffeting response at subsonic and transonic speeds. Phase 1: F-111A flight data analysis. Volume 2: Plotted power spectra

Volume 2 of this three volume report is presented. This volume presents plotted variations of power spectral density data with frequency for each structural response item for each data sampled and analyzed during the course of the investigation. Some of the information contained in Volume 1 are repeated to allow the reader to identify the specific conditions appropriate to each plot presented and to interpret the data.

Benepe, D. B.↗

Dynamics of lithium ions in borotellurite mixed former glasses: Correlation between the characteristic length scales of mobile ions and glass network structural units

We have studied the mixed network former effect on the dynamics of lithium ions in borotellurite glasses in wide composition and temperature ranges. The length scales of ion dynamics, such as characteristic mean square displacement and spatial extent of sub-diffusive motion of lithium ions have been determined from the ac conductivity and dielectric spectra, respectively, in the framework of linear response theory. The relative concentrations of different network structural units have been determined from the deconvolution of the FTIR spectra. A direct correlation between the ion dynamics and the characteristic length scales and the relative concentration of BO{sub 4} units has been established for different compositions of the borotellurite glasses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seismoacoustic Data Fusion for Ground Coupled Airwaves: a FACT Case Study for Calibration and Array Processing

This report covers an inquiry into seismoacoustic array processing using infrasound arrivals combined with resulting Ground Coupled Airwaves (GCA) that are present on collocated seismic sensors. In preparation, data calibration and denoising is completed for a seismoacoustic sensor array that was deployed at the Facility for Acceptance, Calibration, and Testing on Kirtland Airforce Base from August through September of 2021. The events of interest for this study are small, local explosive sources that lead to short duration, impulsive signals on the instruments. The goal is to determine if combining infrasound signals with the corresponding GCAs on collocated seismic sensors can be used to improve the results returned by automated signal detection and characterization (e.g., back azimuth estimates). Preparation for seismic and infrasound data involves removing the instrument response so that sensors have flat power spectra over the frequency range 0.1-10 Hz, where signal from events of interest may be detected. After instrument response removal, deployment conditions specific to this array require a retrospective noise analysis to determine station emplacement characteristics. Once all data is calibrated, a manual search is performed for possible GCA arrivals across the seismoacoustic network. These arrivals are then processed through beamforming and subsequent event identification, resulting in a catalogue of seismoacoustic GCA arrivals with corresponding back azimuth and trace velocity estimations.

47 OTHER INSTRUMENTATION↗

The interpretation of SN-v signals in terrestrial experiments through the folding procedure

The convolution (folding) procedure is applied in order to explore the response of Zn isotopes to the energy-spectra of the supernova neutrinos. At first, double differential cross sections are calculated in the context of the quasi-particle random phase approximation (QRPA) and, then, the cross sections obtained are folded with reliable energy distributions of supernova neutrino spectra. This leads to folded double, integrated, cumulative and total cross sections describing the nuclear response of the Zn isotopes as supernova neutrino detectors. Preliminary results of convoluted neutral-current neutrino-nucleus cross sections for the {sup 64}Zn isotope are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗