Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fabrication and Testing of Habitat Components Using In-Situ Materials for Martian Exploration

The development of Mars for human activity will require the utilization of Martian materials in building habitats and working structures. One approach is to use polymer binders with regolith to form structural elements. Not only can useful composite materials be produced in this way but the radiation protection properties are also increased. This is important since only modest protection from space radiation is provided by the Martian atmosphere. We have studied composites fabricated using Martian regolith simulant and polymers which can be synthesized from local Martian materials for their potential use as radiation shields for manned Mars missions. To validate shielding effectiveness, composites are irradiated with a 55 MeV proton beam and neutron beams up to 800 MeV. Shielding effects on microelectronic devices are measured by placing them behind samples of the composites during irradiation. To measure structural properties of the composites, preliminary characterization and mechanical testing are made for the composites.

Kim, M.-H. Y.↗

Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

Air Craft Icing↗

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

o Aircraft Icing↗

Precision metering of microliter volumes of biological fluids in micro-gravity

Concepts were demonstrated and investigated for transferring accurately known and reproducible microliter volumes of biological fluids from sample container onto dry chemistry slides in microgravity environment. Specific liquid transfer tip designs were compared. Information was obtained for design of a liquid sample handling system to enable clinical chemical analysis in microgravity. Disposable pipet tips and pipet devices that were designed to transfer microliter volumes of biological fluid from a (test tube) sample container in 1-G environment were used during microgravity periods of parabolic trajectories of the KC-135 aircraft. The transfer process was recorded using charge coupled device camera and video cassette equipment. Metering behavior of water, a synthetic aqueous protein solution, and anticoagulated human blood was compared. Transfer of these liquids to 2 substrate materials representative of rapidly wettable and slowly wettable dry chemistry slide surface was compared.

Columbus, Richard L.↗

In Situ Identification of Mineral Resources with an X-Ray-Optical "Hands-Lens" Instrument

The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56). While a sample is being x-rayed, the instrument simultaneously acquires an optical image of the sample surface at magnifications from lx to at least 50x (200x being feasible, depending on the sample surface). We believe that imaging the sample is extremely important as corroborative sample-identification data (the need for this capability having been illustrated by the experience of the Pathfinder rover). Very few geologists would rely on instrument data for sample identification without having seen the sample. Visual inspection provides critical recognition data such as texture, crystallinity, granularity, porosity, vesicularity, color, lustre, opacity, and so forth. These data can immediately distinguish sedimentary from igneous rocks, for example, and can thus eliminate geochemical or mineral ambiguities arising, say between arkose and granite. It would be important to know if the clay being analyzed was part of a uniform varve deposit laid down in a quiescent lake, or the matrix of a megabreccia diamictite deposited as a catastrophic impact ejecta blanket. The unique design of the instrument, which combines Debye-Scherrer geometry with elements of standard goniometry, negates the need for sample preparation of any kind, and thus negates the need for power-hungry and mechanically-complex sampling systems that would have to chip, crush, sieve, and mount the sample for x-ray analysis. Instead, the instrument is simply rested on the sample surface of interest (like a hand lens); the device can interrogate rough rock surfaces, coarse granular material, or fine rock flour. A breadboard version of the instrument has been deployed from the robotic arm of the Marsokhod rover in field trials at NASA Ames, where large vesicular boulders were x-rayed to demonstrate the functionality of the instrument design, and the ability of such a device to comply with constraints imposed by a roving platform. Currently under development is a flight prototype concept of this instrument that will weigh 0.3 kg, using about 4500 J of energy per sample analysis. It requires about 5 min. for XRD analysis, and about 30 min. for XRF interrogation. Its small mass and rugged design make it ideal for deployment on small rovers of the type currently envisaged for the exploration of Mars (e.g., Sojourner-scale platforms). The design utilizes a monolithic P-N junction photodiode pixel array for XRD, a Si PIN photodiode/avalanche photodiode system for XRF, and an endoscopic imaging camera system unobtrusively embedded between the detectors and the x-ray source (the endoscope with its board-mounted camera can be adapted for IR light in addition to visible wavelenths. A rugged, miniature (7 cu cm) x-ray source for the instrument has already been breadboarded.

Marshall, J.↗

Single Drop Cytometry Onboard the International Space Station

Real-time lab analysis is needed to support clinical decision making and research on human missions to the Moon and Mars. Powerful laboratory instruments, such as flow cytometers, are generally too cumbersome for spaceflight. Here, we show that scant test samples can be measured in microgravity, by a trained astronaut, using a miniature cytometry-based analyzer, the rHEALTH ONE, modified specifically for spaceflight. The base device addresses critical spaceflight requirements including minimal resource utilization and alignment-free optics for surviving rocket launch. To fully enable reduced gravity operation onboard the space station, we incorporated bubble-free fluidics, electromagnetic shielding, and gravity-independent sample introduction. We show microvolume flow cytometry from 10 μL sample drops, with data from five simultaneous channels using 10 μs bin intervals during each sample run, yielding an average of 72 million raw data points in approximately 2 minutes. We demonstrate the device measures each test sample repeatably, including correct identification of a sample that degraded in transit to the International Space Station. This approach can be utilized to further our understanding of spaceflight biology and provide immediate, actionable diagnostic information for management of astronaut health without the need for Earth-dependent analysis.

Daniel J. Rea↗

Nonlinear optical thin films

A focused approach to development and evaluation of organic polymer films for use in optoelectronics is presented. The issues and challenges that are addressed include: (1) material synthesis, purification, and the tailoring of the material properties; (2) deposition of uniform thin films by a variety of methods; (3) characterization of material physical properties (thermal, electrical, optical, and electro-optical); and (4) device fabrication and testing. Photonic materials, devices, and systems were identified as critical technology areas by the Department of Commerce and the Department of Defense. This approach offers strong integration of basic material issues through engineering applications by the development of materials that can be exploited as the active unit in a variety of polymeric thin film devices. Improved materials were developed with unprecedented purity and stability. The absorptive properties can be tailored and controlled to provide significant improvement in propagation losses and nonlinear performance. Furthermore, the materials were incorporated into polymers that are highly compatible with fabrication and patterning processes for integrated optical devices and circuits. By simultaneously addressing the issues of materials development and characterization, keeping device design and fabrication in mind, many obstacles were overcome for implementation of these polymeric materials and devices into systems. We intend to considerably improve the upper use temperature, poling stability, and compatibility with silicon based devices. The principal device application that was targeted is a linear electro-optic modulation etalon. Organic polymers need to be properly designed and coupled with existing integrated circuit technology to create new photonic devices for optical communication, image processing, other laser applications such as harmonic generation, and eventually optical computing. The progression from microscopic sample to a suitable film-forming material in a working device is a complex, multifaceted endeavor. It requires close attention to maintaining the optical properties of the electro-optic active portion of the polymer while manipulating the polymer structure to obtain the desired secondary polymer properties.

Leslie, Thomas M.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

Laboratory investigations of cloud nuclei from combustion of Space Shuttle propellant

Small quantities of solid rocket motor propellant, of the type to launch the Space Shuttle, were burned at ambient pressure in the laboratory to provide aerosol samples for characterization. A portion of each sample was injected into an isothermal cloud chamber and the remainder into a 770-liter holding tank. Portable ice nucleus (IN) counters, filter devices for IN determinations and a cloud condensation nucleus (CCN) counter sampled from the tank. The measurements show that particles resulting from the combustion of the propellant are active IN (3.3 times 10 to the 8th to 1.5 times 10 to the 11th/g active at 20 C). The portable counters and filters detected significantly fewer IN than the isothermal cloud chamber. The propellant aerosol is a prolific source of CCN that swamped the instrument.

Hindman Ii, E. E.↗

CMOS imager for pointing and tracking applications

Systems and techniques to realize pointing and tracking applications with CMOS imaging devices. In general, in one implementation, the technique includes: sampling multiple rows and multiple columns of an active pixel sensor array into a memory array (e.g., an on-chip memory array), and reading out the multiple rows and multiple columns sampled in the memory array to provide image data with reduced motion artifact. Various operation modes may be provided, including TDS, CDS, CQS, a tracking mode to read out multiple windows, and/or a mode employing a sample-first-read-later readout scheme. The tracking mode can take advantage of a diagonal switch array. The diagonal switch array, the active pixel sensor array and the memory array can be integrated onto a single imager chip with a controller. This imager device can be part of a larger imaging system for both space-based applications and terrestrial applications.

Pain, Bedabrata↗

Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples

RNA isolation is a ubiquitous need, driven by current emphasis on microarrays and miniaturization. With commercial systems requiring 100,000 to 1,000,000 cells for successful isolation, there is a growing need for a small-footprint, easy-to-use device that can harvest nucleic acids from much smaller cell samples (1,000 to 10,000 cells). The process of extraction of RNA from cell cultures is a complex, multi-step one, and requires timed, asynchronous operations with multiple reagents/buffers. An added complexity is the fragility of RNA (subject to degradation) and its reactivity to surface. A novel, microfluidics-based, integrated cartridge has been developed that can fully automate the complex process of RNA isolation (lyse, capture, and elute RNA) from small cell culture samples. On-cartridge cell lysis is achieved using either reagents or high-strength electric fields made possible by the miniaturized format. Traditionally, silica-based, porous-membrane formats have been used for RNA capture, requiring slow perfusion for effective capture. In this design, high efficiency capture/elution are achieved using a microsphere-based "microfluidized" format. Electrokinetic phenomena are harnessed to actively mix microspheres with the cell lysate and capture/elution buffer, providing important advantages in extraction efficiency, processing time, and operational flexibility. Successful RNA isolation was demonstrated using both suspension (HL-60) and adherent (BHK-21) cells. Novel features associated with this development are twofold. First, novel designs that execute needed processes with improved speed and efficiency were developed. These primarily encompass electric-field-driven lysis of cells. The configurations include electrode-containing constructs, or an "electrode-less" chip design, which is easy to fabricate and mitigates fouling at the electrode surface; and the "fluidized" extraction format based on electrokinetically assisted mixing and contacting of microbeads in a shape-optimized chamber. A secondary proprietary feature is in the particular layout integrating these components to perform the desired operation of RNA isolation. Apart from a novel functional capability, advantages of the innovation include reduced or eliminated use of toxic reagents, and operator-independent extraction of RNA.

Sundaram, Shivshankar↗

Programmable, four-channel, 128-sample, 40-Ms/s analog-ternary correlator

A four-channel analog-ternary CCD correlator that extends the state of the art in several important areas is discussed. Surface acoustic wave, acoustic charge transport, and CCD implementation technologies are compared, and the architecture of the CCD device is described. It is shown that, in addition to a sampling rate up to 40 Ms (megasamples) per second, a dynamic range of 66 dB, and nonlinearity below -50 dB, the device exhibits a level of integration and user-friendliness not previously available. The correlator is intended for use in communications and radar systems where pseudonoise codes are employed.

Munroe, Scott C.↗

Powder Handling Device for Analytical Instruments

Method and system for causing a powder sample in a sample holder to undergo at least one of three motions (vibration, rotation and translation) at a selected motion frequency in order to present several views of an individual grain of the sample. One or more measurements of diffraction, fluorescence, spectroscopic interaction, transmission, absorption and/or reflection can be made on the sample, using light in a selected wavelength region.

Sarrazin, Philippe C.↗

Miniature cyclotron resonance ion source using small permanent magnet

An ion source using the cyclotron resonance principle is described. A miniaturized ion source device is used in an air gap of a small permanent magnet with a substantially uniform field in the air gap of about 0.5 inch. The device and permanent magnet are placed in an enclosure which is maintained at a high vacuum (typically 10 to the minus 7th power) into which a sample gas can be introduced. The ion beam end of the device is placed very close to an aperture through which an ion beam can exit into the apparatus for an experiment.

Anicich, V. G.↗

A 600-MHz median-type digital filter on GaAs

A single-chip GaAs implementation of an FIR-median hybrid filter is presented. The very high-speed digital filter combines linear averaging structures to a median selector. The filter operates on 5-b samples with ECL-compatible I/O interfaces. The 1500-transistor LSI device with 3.6-sq mm chip size was processed with a 1.0-micron GaAs depletion-mode (D-mode) MESFET process. The filter demonstrates 600-MHz sample rate when operated in test mode utilizing special built-in feedback.

Vainjo, Olli↗

Polystyrene latex separations by continuous flow electrophoresis on the Space Shuttle

The seventh mission of the Space Shuttle carried two NASA experiments in the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system. The objectives were to test the operation of continuous flow electrophoresis in a reduced gravity environment using stable particles with established electrokinetic properties and specifically to evaluate the influence of the electrical properties of the sample constituents on the resolution of the continuous flow electrophoretic device. Polystrene latex microspheres dispersed in a solution with three times the electrical conductivity of the curtain buffer separated with a significantly larger band spread compared to the second experiment under matched conductivity conditions. It is proposed that the sample of higher electrical conductivity distorted the electric field near the sample stream so that the polystyrene latex particles migrated toward the chamber walls where electroosmosis retarded and spread the sample.

Snyder, R. S.↗

Summary of activities

Four space projects' activities are summarized. Design work on the Mars Penetrator Project, in cooperation with the NASA Ames Research Center, is being continued. Efforts are focused on the drilling mechanism which must penetrate the martian subsurface soil to collect and retrieve an uncontaminated sample. The new design consists of a rotary-percussive drill mechanism. This mechanism is optimum for dry drilling, necessary to avoid contamination of the soil sample, in many different soil types. The need for a small, relatively inexpensive device to study the chemical structure of this martian soil was also established. The egg design was chosen for its low cost compared to other systems and potential for a large number of eggs to be deployed on the martian surface. The design process included analysis of the dynamics of reentry, dissipation of heat during reentry, impact with the surface, access to undisturbed soil samples, and ability to gather samples from the soil at three depths. The egg consists of the reentry systems, soil probe lifting system, soil probe package, gas chromatograph, transmitter, and battery power supply. The egg must function only once, but is designed to withstand one martian year. The Mars Mole is designed as a rover-based device which penetrates the martian soil to a depth of up to 10 m, obtains a sample of soil, and returns it to the surface for analysis. The mole was designed to meet the following specifications: (1) weight less than 10 kg; (2) size less than 20 x 20 x 30 cm; (3) power less than 100 W; (4) ability to obtain a sample of at least 5 cc; (5) ability to penetrate fine, loose sand; and (6) need to obtain at least one sample. The space station umbilical connector project is a device which provides the translational motion of the connectors on the Space Station Freedom to allow engagement for power and data transfer. The design is capable of delivering a 20 lb force within the necessary tolerances and will operate reliably in the space environment.

Source record↗