Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Theory of anomalous backscattering in second harmonic X-mode ECRH experiments

A quantitative model explaining generation of the anomalous backscattering signal in the second harmonic X-mode electron cyclotron resonance heating (ECRH) experiments at TEXTOR tokamak as a secondary nonlinear process which accompanies a primary low-threshold parametric decay instability (PDI) leading to excitation of two—upper hybrid (UH)—plasmons trapped in plasma is developed. The primary absolute PDI enhancing the UH wave fluctuations from the thermal noise level is supposed to be saturated due to a cascade of secondary low-threshold decays of the daughter UH wave leading to excitation of the secondary UH waves down-shifted in frequency and the ion Bernstein wave. A set of equations describing the cascade is derived and solved numerically. The results of numerical modelling are shown to be in agreement with the analytical estimations of the growth rate of the initial and secondary parametric decays and the saturation level. The generation of backscattering signal is explained by coupling of the daughter UH waves. The fine details of the frequency spectrum of the anomalously reflected extraordinary wave and the absolute value of the observed backscattering signal in the second harmonic X-mode ECRH experiments at TEXTOR are reproduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Choice of tip, signal stability, and practical aspects of piezoresponse-force-microscopy

Piezoresponse force-microscopy (PFM) has become the standard tool to investigate ferroelectrics on the micro- and nanoscale. However, reliability of PFM signals is often problematic and their quantification is challenging and thus not widely applied. Here, we present a study of the reproducibility of PFM signals and of the so-called PFM background signal which has been reported in the literature. We find that PFM signals are generally reproducible to certain extents. The PFM signal difference between 180° domains on periodically poled lithium niobate (PPLN) is taken as the reference signal in a large number of measurements, carried out in a low frequency regime (30-70 kHz). We show that in comparison to Pt coated tips, diamond coated tips exhibit improved signal stability, lower background signal, and less imaging artifacts related to PFM which is reflected in the spread of measurements. This is attributed to the improved mechanical stability of the conductive layer. The average deviation of the mean PFM signal is 38.3%, for a diamond coated tip. Although this deviation is relatively high, it is far better than values from the literature which showed a deviation of approx. 73.1%. Additionally, we find that the average deviation of the background signal from 0 is 11.6% of the PPLN domain contrast. Thus, the background signal needs to be taken into account when quantifying PFM signals and should be subtracted from PFM signals. Those results are important for quantification of PFM signals, since PPLN might be used for this purpose when PFM signals measured on PPLN are related to its macroscopic d{sub 33} coefficient. Finally, the crucial influence of sample polishing on PFM signals is shown and we recommend to use a multistep polishing route with a final step involving 200 nm sized colloidal silica particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmission and reflection of terahertz plasmons in two-dimensional plasmonic devices

We found that plasmons in two-dimensional semiconductor devices will be reflected by discontinuities, notably, junctions between gated and non-gated electron channels. The transmitted and reflected plasmons can form spatially- and frequency-varying signals, and their understanding is important for the design of terahertz detectors, oscillators, and plasmonic crystals. Using mode decomposition, we studied terahertz plasmons incident on a junction between a gated and a nongated channel. The plasmon reflection and transmission coefficients were found numerically and analytically and studied between 0.3 and 1 THz for a range of electron densities. At higher frequencies, we could describe the plasmons by a simplified model of channels in homogeneous dielectrics, for which the analytical approximations were accurate. At low frequencies, however, the full geometry and mode spectrum had to be taken into account. Moreover, the results agreed with simulations by the finite-element method. As a result, mode decomposition thus proved to be a powerful method for plasmonic devices, combining the rigor of complete solutions of Maxwell's equations with the convenience of analytical expressions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of doping profiles on coherent acoustic phonon detection and generation in semiconductors

The doping profile in different n-doped GaAs homoepitaxial structures grown by molecular beam epitaxy is investigated in the time domain by employing a laser based picosecond ultrasound technique in a contactless and noninvasive way. Experiments based on asynchronous optical sampling employ two femtosecond lasers, which allow us to detect changes in the optical reflectivity over a 1 ns time delay with a signal-to-noise ratio of 10{sup 7} and 100 fs time resolution in <1 min of acquisition time. We show that the doping profile with doping densities of the order of 10{sup 18} cm{sup -3} can be detected with picosecond ultrasound, although there is no difference in the acoustic properties of the doped and undoped region. The detection mechanism is based on a different sensitivity function for a coherent strain pulse in the doped and undoped regions. These results are corroborated by experiments at room temperature and 10 K.

36 MATERIALS SCIENCE↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Strong intracellular signal inactivation produces sharper and more robust signaling from cell membrane to nucleus

For a chemical signal to propagate across a cell, it must navigate a tortuous environment involving a variety of organelle barriers. In this work we study mathematical models for a basic chemical signal, the arrival times at the nuclear membrane of proteins that are activated at the cell membrane and diffuse throughout the cytosol. Organelle surfaces within human B cells are reconstructed from soft X-ray tomographic images, and modeled as reflecting barriers to the molecules’ diffusion. We show that signal inactivation sharpens signals, reducing variability in the arrival time at the nuclear membrane. Inactivation can also compensate for an observed slowdown in signal propagation induced by the presence of organelle barriers, leading to arrival times at the nuclear membrane that are comparable to models in which the cytosol is treated as an open, empty region. In the limit of strong signal inactivation this is achieved by filtering out molecules that traverse non-geodesic paths.

59 BASIC BIOLOGICAL SCIENCES↗

Hyperspectral imaging of minerals in the longwave infrared: the use of laboratory directional-hemispherical reference measurements for field exploration data

Hyperspectral Imaging (HSI) continues to grow as a method for remote detection of vegetation, materials, minerals, and pure chemicals. We have used a longwave infrared (7.7 - 11.8 µm) imaging spectrometer in a static outdoor experiment to collect HSI data from 24 minerals and background materials to determine the efficacy with which HSI can remotely detect and distinguish both pure minerals and mineral mixtures at three solar angles (25°, 35°, and 45° relative to ground) as well as varying backgrounds and other sample effects. Measurements were obtained separately for the minerals and materials mounted directly both on a bare plywood board and a plywood board coated with aluminum foil: 19 powders (3 mixtures and 16 pure mineral powders) held in polyethylene bottle lids as well as 5 samples in rock form were taped directly to the boards. The primary goal of the experiment was to demonstrate that a longwave infrared (LWIR) library of solids and minerals collected as directional-hemispherical reflectance spectra in the laboratory can be used directly for HSI field identification. Prior to the experiment, all 24 mineral/inorganic samples were measured in the laboratory using a Fourier transform infrared spectrometer (FTIR) equipped with a gold-coated IR integrating sphere; the spectra were assimilated as part of a larger reference library of 21 pure minerals, 3 mixtures, and the polyethylene lid. Principal components analysis (PCA) with mean-centering was used in an exploratory analysis of the HSI images and showed that for the aluminum coated board, the first principal component captured the difference between signal that resembled a blackbody and the highly reflective aluminum background. In contrast, principal components PC 2, 3, and 4 were able to discriminate the materials including phosphates, sulfates, silicates, carbonates, and the mixtures. Results from generalized least squares target detection clearly showed that laboratory reference spectra of minerals could be utilized as targets with high fidelity for field detection, both for pure and mixed samples.

47 OTHER INSTRUMENTATION↗

Final Scientific/Technical report for "ABI8: Prototype of a novel signaling factor"

The Arabidopsis thaliana ABSCISIC ACID-INSENSITIVE8 locus encodes a highly conserved plant-specific protein that mediates abscisic acid (ABA) and sugar responses essential for growth. Although initial database comparisons revealed no domains of predictable function, it has recently been re-annotated as a member of the Glycosyltransferase family A. However, this function has not been demonstrated experimentally and no specific substrates have been identified. Mutations affecting ABI8 are near-lethal due to pleiotropic yet specific effects including altered ABA signaling, sugar transport, cell wall synthesis, root meristem maintenance, vascular patterning, and male sterility. Because the predicted sequence initially provided no clues, we used a guilt by association strategy to address function of this protein by determining its subcellular localization and identifying interacting proteins. Our studies showed that ABI8 is localized to the endomembrane system and may interact with proteins implicated in Golgi trafficking, lignification, and stress signaling. We found that the root meristem arrest reflects decreased auxin accumulation and resulting decreases in regulators required for meristem identity, all of which can be rescued by added glucose. Further studies showed that this glucose-dependence reflects reduced glucose uptake as well as the decreased expression of sugar-mobilizing enzymes. This work suggests that ABI8 may regulate trafficking of membrane proteins such as auxin transporters and cellulose synthase, but this hypothesis has not yet been tested. The altered gene expression is likely to be a secondary or later effect of this pleiotropic mutation.

59 BASIC BIOLOGICAL SCIENCES↗

The SuperCam remote sensing instrument suite for the Mars 2020 rover mission: A preview

We present that the SuperCam remote sensing instrument suite under development for the National Aeronautics and Space Administration’s (NASA) Mars 2020 rover performs laser-induced breakdown spectroscopy (LIBS), remote Raman spectroscopy, visible and infrared (VISIR) reflectance spectroscopy, acoustic sensing, and high-resolution color imaging. The instrument builds on the successful architecture of the ChemCam instrument, which provides LIBS and panchromatic images on the Curiosity rover, adding remote Raman spectroscopy by frequency doubling the laser and using a gated intensified detector to obtain Raman signals at distances to 12 m. To the visible reflectance spectroscopy used by ChemCam, an acousto-optic tunable filter (AOTF)-based IR spectrometer is added to cover the 1.3–2.6 µm range that contains important mineral signatures. A complementary metal-oxide semiconductor (CMOS) detector provides color (Bayer filter) images at a pixel resolution of 19 µrad and an optical resolution of 30 µrad. Sounds are recorded via a Knowles Electret microphone, which is the same one that was included but not used on two earlier missions. The acoustic signals of the LIBS plasmas will provide information on the hardness of the targets, while other sounds (wind, rover sounds) will also be recorded. The laser, telescope, IR spectrometer, and camera reside on the rover’s mast and are provided by the Centre national d’etudes spatiales (CNES), while the LIBS, Raman, and VIS spectrometers and data processing unit are built by Los Alamos National Laboratory (LANL) and reside in the rover body. A calibration target assembly provided by the University of Valladolid, Spain, resides on the back of the rover. Lastly, the overall mass of the instrument suite is 10.7 kg.

47 OTHER INSTRUMENTATION↗

Software-Defined Ultrasonic Communication System Based on Time-reversal Signal Processing

Ultrasonic communication through solid channels suffers from channel dispersion, attenuation, and multipath effect. For example, in elbow shape pipes or complex structures, the elastic waves are reflected and reverberated in multipath resulting in a major dispersion of the signals. In solid channels such as flat bar, multipath propagation is the main reason for bit-wavelet spreading and intersymbol interference (ISI). The conventional modulation method like OOK (on-off-keying) or PSK (phase-shift-keying) fails to provide a useful Signal-to-Noise Ratio (SNR). Time-reversal (TR) signal processing method is a promising technique that can compress the spreading of the bit-wavelet and strengthen the peak signal energy on the receiver. In this study, Finite Element Analysis (FEA) using ABAQUS software tools is used to characterize the bit-wavelet spreading effect caused by dispersive communication channels. Also, this study presents the impact of TR ultrasonic communication as a function of excitation pulse width, channel length, and carrier frequency through a flat-bar channel. A Software-Defined System-on-Chip (SD-SoC) platform is examined as a viable solution for the low-complexity and energy-efficient ultrasonic communication system. The proposed TR based SD-SoC ultrasonic communication system can make full use of signal dispersion for peak performance by minimizing the ISI within a dispersive and reverberant metal channel.

FEM simulation↗

The effects of the ionosphere on ground-based detection of the global 21 cm signal from the cosmic dawn and the dark ages

Detection of the global H i 21 cm signal from the Cosmic Dawn and the Epoch of Reionization is the key science driver for several ongoing ground-based and future ground-/space-based experiments. The crucial spectral features in the global 21 cm signal (turning points) occur at low radio frequencies ≲100 MHz. In addition to the human-generated radio frequency interference, Earth’s ionosphere drastically corrupts low-frequency radio observations from the ground. In this paper, we examine the effects of time-varying ionospheric refraction, absorption, and thermal emission at these low radio frequencies and their combined effect on any ground-based global 21 cm experiment. It should be noted that this is the first study of the effect of a dynamic ionosphere on global 21 cm experiments. The fluctuations in the ionosphere are influenced by solar activity with flicker noise characteristics. The same characteristics are reflected in the ionospheric corruption to any radio signal passing through the ionosphere. As a result, any ground-based observations of the faint global 21 cm signal are corrupted by flicker noise (or 1/f noise, where f is the dynamical frequency) which scales as ν{sup −2} (where ν is the frequency of radio observation) in the presence of a bright galactic foreground (∝ν{sup −s}, where s is the radio spectral index). Hence, the calibration of the ionosphere for any such experiment is critical. Any attempt to calibrate the ionospheric effects will be subject to the inaccuracies in the current ionospheric measurements using Global Positioning System (GPS) ionospheric measurements, riometer measurements, ionospheric soundings, etc. Even considering an optimistic improvement in the accuracy of GPS–total electron content measurements, we conclude that Earth’s ionosphere poses a significant challenge in the absolute detection of the global 21 cm signal below 100 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Geophysical Signatures of Crack Network Coalescence in Rocks at Multiple Length Scales

The main goal of the research project was to identify the geophysical signatures of fracture growth in natural rocks by utilizing novel geophysical techniques. The research objectives were to (a) investigate the potential for geophysical methods to determine when cracks initiate, the types and locations of propagated cracks, and the coalescence of networks of cracks in natural rocks at multiple scales, (b) determine how damage at the microscale evolved into damage at the macroscale and then link the microscopic and macroscopic observations, (c) quantify crack coalescence in rocks under realistic stress conditions using coupled mechanical-geophysical-optical visualization, and (d) identify the precursors in geophysical signals to crack coalescence. The following research thrusts were explored to achieve the research objectives: (1) uniaxial compression testing of rock specimens with and without a set of pre‐existing flaws and (2) triaxial compression testing of natural rock specimens. These thrusts allowed for exploring fracturing in rocks under realistic in situ environments and at multiple scales. This project provided educational opportunities for nine graduate and undergraduate students and resulted in 27 peer-reviewed publications. This first research thrust focused on investigating the micromechanics of fractures in rocks through uniaxial compression testing combined with advanced geophysical and imaging techniques, specifically acoustic emission (AE) monitoring, ultrasonic imaging, and 2-dimensional Digital Image Correlation (2D-DIC). By examining damage processes under time-independent and time-dependent loading conditions, insights into damage localization, crack initiation, and fracturing mechanisms were gained. It was observed that the AE signals and the strain-based measurements directly reflect the state of damage in the rock specimen and could be used to identify the cracking levels, such as the crack initiation (CI) and crack damage (CD), and the mode of deformation. A novel calibration apparatus was developed to enhance the accuracy of AE sensors, allowing for the estimation of key parameters such as magnitude, source dimension, stress drop, and radiated seismic energy associated with the fractures. The findings highlighted significant variations in the temporal evolution of AE source parameters during the primary, secondary, and tertiary stages of creep, identifying tensile cracking as the primary deformation mode. The second research thrust focused on enhancing the understanding of fracturing processes in natural rocks through triaxial compression testing, real-time AE monitoring, and ultrasonic monitoring. We investigated the impact of various factors such as fracture propagation regimes, injection parameters, rock types, and pre-existing conditions on the hydraulic fracture (HF) behavior using scaled true-triaxially loaded specimens of Barre granite and Lyons sandstone. Custom sensor housing facilitated concurrent active and passive monitoring to analyze hydro-mechanical responses and microseismicity associated with different HF scenarios. A coupled investigation of passive microseismicity and active signal attributes permitted a detailed comprehension of the various HF processes (aseismic deformation, fracture initiation and propagation, fluid permeation, and leak-off) and their dependence on the specific rock type. The findings of this research demonstrated the effectiveness of AE monitoring techniques in providing valuable insights into the impact of various factors on the behavior and dynamics of HF processes. The advancements in monitoring techniques, offering a more thorough and precise approach, represent a significant step towards optimizing HF practices and ensuring sustainable resource extraction.

58 GEOSCIENCES↗

Laser induced deflection technique for absolute thin film absorption measurement: optimized concepts and experimental results

Using experimental results and numerical simulations, two measuring concepts of the laser induced deflection (LID) technique are introduced and optimized for absolute thin film absorption measurements from deep ultraviolet to IR wavelengths. For transparent optical coatings, a particular probe beam deflection direction allows the absorption measurement with virtually no influence of the substrate absorption, yielding improved accuracy compared to the common techniques of separating bulk and coating absorption. For high-reflection coatings, where substrate absorption contributions are negligible, a different probe beam deflection is chosen to achieve a better signal-to-noise ratio. Various experimental results for the two different measurement concepts are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer

Core-ion temperature measurements have been carried out by the energy analysis of passive charge exchange (CX) neutrals escaping out of the ADITYA tokamak plasma (minor radius, a= 25 cm and major radius, R= 75 cm) using a 45 Degree-Sign parallel plate electrostatic energy analyzer. The neutral particle analyzer (NPA) uses a gas cell configuration for re-ionizing the CX-neutrals and channel electron multipliers (CEMs) as detectors. Energy calibration of the NPA has been carried out using ion-source and {Delta}E/E of high-energy channel has been found to be {approx}10%. Low signal to noise ratio (SNR) due to VUV reflections on the CEMs was identified during the operation of the NPA with ADITYA plasma discharges. This problem was rectified by upgrading the system by incorporating the additional components and arrangements to suppress VUV radiations and improve its VUV rejection capabilities. The noise rejection capability of the NPA was experimentally confirmed using a standard UV-source and also during the plasma discharges to get an adequate SNR (>30) at the energy channels. Core-ion temperature T{sub i}(0) during flattop of the plasma current has been measured to be up to 150 eV during ohmically heated plasma discharges which is nearly 40% of the average core-electron temperature (typically T{sub e}(0) {approx} 400 eV). The present paper describes the principle of tokamak ion temperature measurement, NPA's design, development, and calibration along with the modifications carried out for minimizing the interference of plasma radiations in the CX-spectrum. Performance of the NPA during plasma discharges and experimental results on the measurement of ion-temperature have also been reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STL-548 Non-Reflecting Protective Unit (NRPU)

This report describes the fundamental operation of the key operating points of the NRPU system, which is a 50-ohm system that protects front-end digitizers from large signal pulses and is designed to limit large signals while passing smaller signals in a single-shot type experiment with little back-reflection.

1GHz high voltage front-end digitizer protection↗

An estimation method for echo signal energy of pipe inner surface longitudinal crack detection by 2-D energy coefficients integration

The echo signal energy is directly affected by the incident sound beam eccentricity or angle for thick-walled pipes inner longitudinal cracks detection. A method for analyzing the relationship between echo signal energy between the values of incident eccentricity is brought forward, which can be used to estimate echo signal energy when testing inside wall longitudinal crack of pipe, using mode-transformed compression wave adaptation of shear wave with water-immersion method, by making a two-dimension integration of “energy coefficient” in both circumferential and axial directions. The calculation model is founded for cylinder sound beam case, in which the refraction and reflection energy coefficients of different rays in the whole sound beam are considered different. The echo signal energy is calculated for a particular cylinder sound beam testing different pipes: a beam with a diameter of 0.5 inch (12.7mm) testing a φ279.4mm pipe and a φ79.4mm one. As a comparison, both the results of two-dimension integration and one-dimension (circumferential direction) integration are listed, and only the former agrees well with experimental results. The estimation method proves to be valid and shows that the usual method of simplifying the sound beam as a single ray for estimating echo signal energy and choosing optimal incident eccentricity is not so appropriate.

36 MATERIALS SCIENCE↗