Search NASA⌕ Search

SEARCH · Search NASA

Results for “SILICON RADIATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

MaPSA Quality Control and AI-Enhanced Grading For the CMS Phase-II Tracker Upgrade

The Compact Muon Solenoid (CMS) experiment will undergo changes as part of the Large Hadron Collider upgrade. The CMS tracker will be upgraded to cope with the new radiation environment and to provide tracking at the first level trigger. This upgrade features a new type of silicon module called PS Module, which combines a Pixel sensor and a Strip sensor in the same module. The pixel portion of the PS module has a sensor bump bonded to 16 Macro Pixel ASICs (MPA) to form a Macro Pixel Sub Assembly (MaPSA). At Fermilab, MaPSAs are tested for quality control before being assembled with the strip sensors, readout and service electronics to form a PS Module. All of this test data is stored in a centralized database, and is used to grade the final module to determine if it will be installed in the detector. The Phase II Outer Tracker Analyzer of Test Outputs (POTATO) is the software that processes this data and determines the module grades. Using recent technologies, an AI agent is being im plemented into POTATO in order to allow users to more efficiently sort through the large amounts of analysis data and ensure that only the user specified data is being considered. This poster will display the process of testing a MaPSA, how that test data is relevant to module assembly and grading, and how the POTATO grading tool is being improved with the use of an embedded AI agent.

Gzamouranis, Olivia [Purdue U.]↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Superconducting Hot-Electron Submillimeter-Wave Detector

A superconducting hot-electron bolometer has been built and tested as a prototype of high-sensitivity, rapid-response detectors of submillimeter-wavelength radiation. There are diverse potential applications for such detectors, a few examples being submillimeter spectroscopy for scientific research; detection of leaking gases; detection of explosive, chemical, and biological weapons; and medical imaging. This detector is a superconducting-transition- edge device. Like other such devices, it includes a superconducting bridge that has a low heat capacity and is maintained at a critical temperature (T(sub c)) at the lower end of its superconducting-transition temperature range. Incident photons cause transient increases in electron temperature through the superconducting-transition range, thereby yielding measurable increases in electrical resistance. In this case, T(sub c) = 6 K, which is approximately the upper limit of the operating-temperature range of silicon-based bolometers heretofore used routinely in many laboratories. However, whereas the response speed of a typical silicon- based laboratory bolometer is characterized by a frequency of the order of a kilohertz, the response speed of the present device is much higher characterized by a frequency of the order of 100 MHz. For this or any bolometer, a useful figure of merit that one seeks to minimize is (NEP)(tau exp 1/2), where NEP denotes the noise-equivalent power (NEP) and the response time. This figure of merit depends primarily on the heat capacity and, for a given heat capacity, is approximately invariant. As a consequence of this approximate invariance, in designing a device having a given heat capacity to be more sensitive (to have lower NEP), one must accept longer response time (slower response) or, conversely, in designing it to respond faster, one must accept lower sensitivity. Hence, further, in order to increase both the speed of response and the sensitivity, one must make the device very small in order to make its heat capacity very small; this is the approach followed in developing the present device.

Karasik, Boris↗

Low-threshold sapphire detector for rare event searches

Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CE$v$NS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. Here, we report experimental results from a 100 g single-crystal sapphire detector design with a diameter of 76 mm and thickness of 4 mm instrumented with transition edge sensors (TES). Sapphire is a crystal of aluminum oxide (Al 2 O) and has been found to be a good candidate for light mass dark matter search experiments due to its lower atomic mass compared to other detector materials such as germanium and silicon. This new phonon-assisted sapphire detector was characterized to yield a baseline recoil energy resolution of 28.4 ± 0.4 eV. The detector is designed to be sensitive to low-energy rare interactions with an intention to investigate the low-mass region of dark matter phase-space and search for CE$v$NS at the reactor site.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS↗

First measurement of proton decay from a transfer reaction to 21 Na

Decay protons from excited states in Na 21 populated through a previously reported Mg 24 ( p , α ) Na 21 transfer reaction [Cha et al. , Phys. Rev. C 96 , 025810 (2017) ] were analyzed to extract the proton branching ratios of the energy levels. Additionally, by utilizing 31-MeV proton beams from the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory and isotopically enriched Mg 24 solid targets, the decay protons were detected in coincidence with α particles from the ( p , α ) reaction using a silicon strip detector array. Proton decay branching ratios of several Na 21 levels were deduced for the p 0 and p 1 decay channels to the ground and first excited states in Ne 20 , respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operation and performance of the ATLAS semiconductor tracker in LHC Run 2

The semiconductor tracker (SCT) is one of the tracking systems for charged particles in the ATLAS detector. It consists of 4088 silicon strip sensor modules. During Run 2 (2015–2018) the Large Hadron Collider delivered an integrated luminosity of 156 fb ₋1 to the ATLAS experiment at a centre-of-mass proton-proton collision energy of 13 TeV. The instantaneous luminosity and pile-up conditions were far in excess of those assumed in the original design of the SCT detector. Due to improvements to the data acquisition system, the SCT operated stably throughout Run 2. It was available for 99.9% of the integrated luminosity and achieved a data-quality efficiency of 99.85%. Detailed studies have been made of the leakage current in SCT modules and the evolution of the full depletion voltage, which are used to study the impact of radiation damage to the modules.

47 OTHER INSTRUMENTATION↗

Characterization of silicon drift detectors with electrons for the TRISTAN project

Sterile neutrinos are a minimal extension of the standard model of particle physics. A promising model-independent way to search for sterile neutrinos is via high-precision β-spectroscopy. The Karlsruhe tritium neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector’s response to electrons on the final sterile neutrino sensitivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compact Focal Plane Assembly for Planetary Science

A compact radiometric focal plane assembly (FPA) has been designed in which the filters are individually co-registered over compact thermopile pixels. This allows for construction of an ultralightweight and compact radiometric instrument. The FPA also incorporates micromachined baffles in order to mitigate crosstalk and low-pass filter windows in order to eliminate high-frequency radiation. Compact metal mesh bandpass filters were fabricated for the far infrared (FIR) spectral range (17 to 100 microns), a game-changing technology for future planetary FIR instruments. This fabrication approach allows the dimensions of individual metal mesh filters to be tailored with better than 10- micron precision. In contrast, conventional compact filters employed in recent missions and in near-term instruments consist of large filter sheets manually cut into much smaller pieces, which is a much less precise and much more labor-intensive, expensive, and difficult process. Filter performance was validated by integrating them with thermopile arrays. Demonstration of the FPA will require the integration of two technologies. The first technology is compact, lightweight, robust against cryogenic thermal cycling, and radiation-hard micromachined bandpass filters. They consist of a copper mesh supported on a deep reactive ion-etched silicon frame. This design architecture is advantageous when constructing a lightweight and compact instrument because (1) the frame acts like a jig and facilitates filter integration with the FPA, (2) the frame can be designed so as to maximize the FPA field of view, (3) the frame can be simultaneously used as a baffle for mitigating crosstalk, and (4) micron-scale alignment features can be patterned so as to permit high-precision filter stacking and, consequently, increase the filter bandwidth and sharpen the out-of-band rolloff. The second technology consists of leveraging, from another project, compact and lightweight Bi0.87Sb0.13/Sb arrayed thermopiles. These detectors consist of 30-layer thermopiles deposited in series upon a silicon nitride membrane. At 300 K, the thermopile arrays are highly linear over many orders of magnitude of incident IR power, and have a reported specific detectivity that exceeds the requirements imposed on future mission concepts. The bandpass filter array board is integrated with a thermopile array board by mounting both boards on a machined aluminum jig.

Brown, Ari↗

Direct Alpha Spectrometry of Nuclear Fallout

Advanced instruments and methods are under development to allow direct alpha spectrometry of nuclear fallout debris near the point of collection, to support nuclear forensics (NF). New approaches are needed to support NF in order to accelerate the process for data generation and reduce the overall timeline for decision making. Fallout debris at short time periods following detonation can be difficult to work with for alpha spectrometry, due to the presence of intense beta radiation originating from significant quantities of high-activity fission products. Intense beta radiation can challenge traditional silicon-based high-resolution alpha spectrometers. Addressing this, single-crystal (sc) chemical vapor deposition (CVD) produced diamond semiconductors have been studied for use for alpha spectrometry for assaying nuclear fallout debris. Tests have been performed using scCVD sensors to assay a variety of actinide-bearing samples. Sample preparation, when done, has been limited to pulverization using a mechanical ball mill. To reduce measurement times, multi-chip arrays of scCVD diamond semiconductor have been developed in form factors suitable for field deployment in support of NF objectives. These arrays have been tested using high-beta-activity sol gel surrogate nuclear explosive debris (SNED) containing varying concentrations of uranium and plutonium. Results from the use of scCVD detectors with sol gel SNED will be presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Monte Carlo Simulations of the Response of the MARIE Instrument

The MARIE instrument aboard Mars Odyssey functions as a telescope for the detection of charged, energetic, nuclei. The directionality that leads to the telescope description is achieved by requiring coincident signals in two designated detectors in MARIE s silicon detector stack for the instrument to trigger. Because of this, MARIE is actually a bi directional telescope. Triggering particles can enter the detector stack by passing through the lightly shielded front of the instrument, but can also enter the back of the instrument by passing through the bulk of Odyssey. Because of this, understanding how to relate the signals recorded by MARIE to astrophysically important quantities such as particle fluxes or spectra exterior to the spacecraft clearly requires detailed modeling of the physical interactions that occur as the particles pass through the spacecraft and the instrument itself. In order to facilitate in the calibration of the MARIE data, we have begun a program to simulate the response of MARIE using the FLUKA [1] [2] Monte Carlo radiation transport code.

Andersen, V.↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasibility of crystal-assisted collimation in the CERN accelerator complex

Bent silicon crystals mounted on high-accuracy angular actuators were installed in the CERN Super Proton Synchrotron (SPS) and extensively tested to assess the feasibility of crystal-assisted collimation in circular hadron colliders. The adopted layout was exploited and regularly upgraded for about a decade by the UA9 Collaboration. The investigations provided the compelling evidence of a strong reduction of beam losses induced by nuclear inelastic interactions in the aligned crystals in comparison with amorphous orientation. A conceptually similar device, installed in the betatron cleaning insertion of CERN Large Hadron Collider (LHC), was operated through the complete acceleration and storage cycle and demonstrated a large reduction of the background leaking from the collimation region and radiated into the cold sections of the accelerator and the experimental detectors. The implemented layout and the relevant results of the beam tests performed in the SPS and in the LHC with stored proton and ion beams are extensively discussed.

43 PARTICLE ACCELERATORS↗

Identification and mitigation of memory block timing issue in ITk ABCStar during ASIC production

The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the ABCStar that was reducing wafer yields in some manufactured lots from the expected 90% to as low as 2%. The root cause was determined to be a timing issue in the logic synthesized to control previously silicon proven memory blocks re-used for this ASIC. The solutions proposed included manufacturing process changes by the wafer foundry, changes to the operating parameters for the ABCStar in the detector, and the possibility that a redesign might be required. The two mitigation efforts were undertaken in parallel, with the process modification route a less desirable solution since already manufactured wafers would need to be scrapped in favour of the new ones. Based on a knowledge of the existing process, and testing done on the worst performing wafers, it was proposed that raising the core operating voltage of the ABCStar from 1.20V to 1.25V could address the timing issue by sufficiently speeding up its transistors. An extensive testing program that included the effects of temperature and radiation expected over the lifetime of the ITk detector was conducted to validate that approach. Those tests and studies proved that even the worst performing wafers would have yields over 80% with the 1.25V core voltage, and neither the modified process nor redesign would be required for ensuring reliable operation of the ITk. Based on testing, a further timing mitigation was implemented to provide an additional margin of reliability by increasing the duty cycle of the clock to the ABCStar. Testing of all ABCStar wafers has been completed and the production of the detector modules using these ASICs is now well underway as a result of the efforts detailed herein.

FOS: Physical sciences↗

Soft X-ray quantum efficiency of a commercial CMOS imaging sensor

The demonstrated performance and cost-effectiveness of complementary metal-oxide-semiconductor (CMOS) sensors make them a potentially attractive option for low-cost space-based X-ray observatories. We have previously reported on the performance of a commercially available backside-illuminated Sony IMX290LLR-C CMOS sensor and found it to offer X-ray spectral resolutions comparable to the charged coupled devices (CCDs) aboard Suzaku and Chandra and to have a sufficient radiation hardness for use in low Earth orbit. Here, in this work, we report on the quantum efficiency (QE) of this sensor, an essential metric for modeling the sensitivity of an instrument as an X-ray detector. Using the Advanced Photon Source at Argonne National Laboratory, we measure the soft X-ray QE of this CMOS sensor to be 0.28 ± 0.02 at a photon energy of 490.5 eV. This energy was chosen for its proximity to the astrophysically important O VII triplet emission lines (~574 eV) studied by the HaloSat mission. Although not surpassing that of the back-illuminated CCDs aboard Suzaku and Chandra, this QE compares favorably to that of the front-illuminated CCDs aboard the same observatories and is competitive with that of the silicon drift detectors used aboard HaloSat, making it a strong candidate for use on future X-ray small satellite (SmallSat) missions.

47 OTHER INSTRUMENTATION↗

Beam Test Characterization of an Irradiated Pixel-Strip Module for HL_LHC CMS Tracker Upgrade

A new tracker, for the CMS detector at The Large Hadron Collider, will be built to address the demands of the High Luminosity upgrade which aims to achieve peak instantaneous luminosities from 5 up to 7.5 10^34 cm^-2 s^-1 and an integrated luminosity of 3000 4000 fb^-1 at a center of mass energy of 14 TeV. To meet the resulting challenges, the CMS experiment is changing its outer tracker silicon modules to include tracking capabilities at the Level-1 trigger. As part of this upgrade effort, a prototype module, combining both pixel and strip sensors (PS-module), was irradiated and subsequently tested at the Fermilab Test Beam and Irradiation facilities. These tests evaluated the module's ability to maintain precise tracking, effective particle momentum discrimination, and consistent performance when exposed to the radiation levels expected in the High Luminosity LHC environment. Results from these studies are presented with a focus on comparing the module's performance before and after irradiation.

43 PARTICLE ACCELERATORS↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗