SEARCH · Search NASA
Results for “SIZE”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Thermodynamic properties of Pt nanoparticles: Size, shape, support, and adsorbate effects
Not Available
Ferroelectricity in ultrathin strained BaTiO3 films: probing the size effect by ultraviolet Raman spectroscopy
We demonstrate a dramatic effect of film thickness on the ferroelectric phase transition temperature, Tc, in strained BaTiO3 films grown on SrTiO3 substrates. Using variable temperature ultraviolet Raman spectroscopy enables measuring Tc in ¯lms as thin as 1.6 nm, and film thickness variation from 1.6 to 10 nm leads to Tc tuning from 70 to about 925 K. Raman data are consistent with synchrotron x-ray scattering results, which indicate the presence of of 180± domains below Tc, and thermodynamic phase-field model calculations of Tc as a function of thickness.
Proton Size Anomaly
A measurement of the Lamb shift in muonic hydrogen yields a charge radius of the proton that is smaller than the CODATA value by about 5 standard deviations. We explore the possibility that new scalar, pseudoscalar, vector, and tensor flavor-conserving nonuniversal interactions may be responsible for the discrepancy. We consider exotic particles that, among leptons, couple preferentially to muons and mediate an attractive nucleon-muon interaction. We find that the many constraints from low energy data disfavor new spin-0, spin-1, and spin-2 particles as an explanation.
Observation of Size-Dependent Thermalization in CdSe Nanocrystals Using Time-Resolved Photoluminescence Spectroscopy
Not Available
Allelic Variation in the Chloroplast Division Gene FtsZ2-2 Leads to Natural Variation in Chloroplast Size
Not provided.
Sizing Energy Storage Systems to Mitigate Variability of Renewable Generation for Grid Stability using Inverse Uncertainty Propagation
Explore the source record for details and available documents.
Optimal Sizing of Behind-the-Meter Energy Storage with Stochastic Load and PV Generation for Islanded Operation
Abstract not provided.
Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images
Purpose: To estimate attenuation using cross sectional CT images and scanned projection radiograph (SPR) images in a series of thorax and abdomen phantoms. Methods: Attenuation was quantified in terms of a water cylinder with cross sectional area of A{sub w} from both the CT and SPR images of abdomen and thorax phantoms, where A{sub w} is the area of a water cylinder that would absorb the same dose as the specified phantom. SPR and axial CT images were acquired using a dual-source CT scanner operated at 120 kV in single-source mode. To use the SPR image for estimating A{sub w}, the pixel values of a SPR image were calibrated to physical water attenuation using a series of water phantoms. A{sub w} and the corresponding diameter D{sub w} were calculated using the derived attenuation-based methods (from either CT or SPR image). A{sub w} was also calculated using only geometrical dimensions of the phantoms (anterior-posterior and lateral dimensions or cross sectional area). Results: For abdomen phantoms, the geometry-based and attenuation-based methods gave similar results for D{sub w}. Using only geometric parameters, an overestimation of D{sub w} ranging from 4.3% to 21.5% was found for thorax phantoms. Results for D{sub w} using the CT image and SPR based methods agreed with each other within 4% on average in both thorax and abdomen phantoms. Conclusions: Either the cross sectional CT or SPR images can be used to estimate patient attenuation in CT. Both are more accurate than use of only geometrical information for the task of quantifying patient attenuation. The SPR based method requires calibration of SPR pixel values to physical water attenuation and this calibration would be best performed by the scanner manufacturer.
Texture of Nanocrystalline Nickel: Probing the Lower Size Limit of Dislocation Activity
Explore the source record for details and available documents.
Size- and morphology-dependent structural transformations in anatase TiO[subscript 2] nanowires under high pressures
Abstract not provided
Critical Size Range of Sub-Nanometer Au Clusters for the Catalytic Activity in the Hydrogen Oxidation Reaction
N/A
Determination of Single- and Multi-Component Nanoparticle Sizes by X-ray Absorption Spectroscopy
Not Available