Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

High spectral resolution airborne spectrometry

An airborne spectroradiometer system developed at Columbia University has been providing new spectral data for use in remote sensing for natural resources. The system has been improved by addition of a solid state silicon detector array, and has been extended into the infrared by addition of a 64 element lead sulfide detector array. The infrared data in the 2000 to 2500 nm region especially holds large potential for mineral and oil exploration.

Collins, W.↗

Mass spectrometry in the stratosphere

A gas expansion system incorporating a mass spectrometer that has been successfully flown in the stratosphere is described. Neutral gas particles are formed into a molecular beam that traverses the ion source of the mass spectrometer without wall interactions. It is noted that vertical profiles of such constituents as H2O, CO2, and O3 have been measured in the altitude range of 20 to 40 km during balloon descents. Isotopes of important gases (N2, O2, Ar) provided in-flight calibration standards. Before each flight the mass spectrometer system is calibrated in the laboratory for many gases of interest, including ozone. Mixing ratios of ozone established from recent flights have accuracies of better than 5 percent. The sensitivity of the system is sufficient to detect as well the heavy isotope of ozone at mass 50. A noticeable enhancement of heavy ozone in the upper stratosphere has been found. The mass spectrometer system is seen as providing a unique opportunity to perform in situ measurements in the stratosphere in combination with isotopic studies.

Mauersberger, K.↗

Applications of mass spectrometry techniques to autoclave curing of materials

Mass spectrometer analysis of gases evolved from polymer materials during a cure cycle can provide a wealth of information useful for studying cure properties and procedures. In this paper data is presented for two materials to support the feasibility of using mass spectrometer gas analysis techniques to enhance the knowledge of autoclave curing of composite materials and provide additional information for process control evaluation. It is expected that this technique will also be useful in working out the details involved in determining the proper cure cycle for new or experimental materials.

Smith, A. C.↗

Measurements of I-129 in meteorites and lunar rock by tandem accelerator mass spectrometry

Precise measurements of the half-life of I-129 in three different meteorites and one lunar surface rock are reported. The meteorite source of I-129 was produced by cosmic ray secondary neutron reactions on Te, while the source in lunar materials in spallation on barium and rare earth elements. The Abee, Allende, and Dhajala meteorites were examined, together with the lunar rock 14310. Details of the process used to extract the iodine are provided. The Abee and Allende samples exhibited a production of 0.5 atom/min per gm of Te from the (n,2n) reaction and 0.05 atom/min/gm for the (n,gamma) reaction. The I-129 is concluded to be a viable tool for long-lived cosmogenic nuclide studies. Further work to extend the data to include the constancy of the cosmic ray flux, the meteorite bombardment history, and the cosmic exposure age dating by means of the I-129 and Xe-129 method is indicated.

Nizhiizumi, K.↗

Application of mass spectrometry to process control for polymer material in autoclave curing

Mass spectrometer analysis of gas samples collected during a cure cycle of polymer materials can be used as a process control technique. This technique is particularly helpful in studying the various types of solvents and resin systems used in the preparation of polymer materials and characterizing the chemical composition of different resin systems and their mechanism of polymerization.

Smith, A. C.↗

C-14 content of ten meteorites measured by tandem accelerator mass spectrometry

Measurements of C-14 in three North American and seven Antarctic meteorites show in most cases that this cosmogenic isotope, which is tightly bound, was separated from absorbed atmospheric radiocarbon by stepwise heating extractions. The present upper limit to age determination by the accelerator method varies from 50,000 to 70,000 years, depending on the mass and carbon content of the sample. The natural limit caused by cosmic ray production of C-14 in silicate rocks at 2000 m elevation is estimated to be 55,000 + or - 5000 years. An estimation is also made of the 'weathering ages' of the Antarctic meteorites from the specific activity of loosely bound CO2 which is thought to be absorbed from the terrestrial atmosphere. Accelerator measurements are found to agree with previous low level counting measurements, but are more sensitive and precise.

Brown, R. M.↗

Analyses via automated mass spectrometry (MS/DS)

New or improved uses of the Finnigan 4000 quadrupole mass spectrometer (MS) with its associated INCOS data system (DS) were investigated. The first phase involved an evaluative activity in which specific problems with miscalibration and gas chromatographic column conditioning were identified. This also revealed one solution to the problem of detection of substances not visible in the gas chromatography detection mode. A second phase was to seek useful applications of the direct inlet systems. This mode of sample introduction has not been previously utilized on the existing equipment and was successfully applied to the analysis of the components of TONOX 60/40 and in the thermal degradation products of some polymeric materials. Suggestions are made for improving and expanding the use of the MS/DS system in materials development and testing.

Koenig, T.↗

Analysis of individual biological particles by mass spectrometry

A method is developed for the detection and identification of biological particles introduced in aerosol form into a quadrupole mass spectrometer. The bacterial aerosol is generated by nebulizing an ethanol suspension. The particles are introduced into the ion source of the mass spectrometer in the form of a beam, where they are individually volatilized on a V-type rhenium filament and ionized by electron impaction. It is shown that the average intensity of a mass peak is obtained from the pulse height distribution of about a thousand ion pulses from different particles. Pseudomonas putida, Bacillus subtilis, and Bacillus cereus are used in the studies. Differences between the relative intensities of mass peaks in the spectra from P. putida and B. subtilis are found and may provide a method for differentiation of microorganisms. The results for the two species agree reasonably well with those reported by Kistemaker et al. (1975) and Schulten et al. (1973). However, there exist some differences between the two spectra in the high mass range due to the difference in the pyrolysis conditions.

Sinha, M. P.↗

High Resolution Spectrometry of Leaf and Canopy Chemistry for Biochemical Cycling

High-resolution laboratory spectrophotometer and Airborne Imaging Spectrometer (AIS) data were used to analyze forest leaf and canopy chemistry. Fundamental stretching frequencies of organic bonds in the visible, near infrared and short-wave infrared are indicative of concentrations and total content of nitrogen, phosphorous, starch and sugar. Laboratory spectrophotometer measurements showed very strong negative correlations with nitrogen (measured using wet chemistry) in the visible wavelengths. Strong correlations with green wet canopy weight in the atmospheric water absorption windows were observed in the AIS data. A fairly strong negative correlation between the AIS data at 1500 nm and total nitrogen and nitrogen concentration was evident. This relationship corresponds very closely to protein absorption features near 1500 nm.

Spanner, M. A.↗

Infrared polar brightening on Jupiter. III - Spectrometry from the Voyager 1 IRIS experiment

Spectra from the Voyager 1 IRIS experiment confirm the existence of enhanced infrared emission near Jupiter's north magnetic pole in March 1979. The spectral characteristics of the enhanced emission are consistent with a Planck source function. A temperature-pressure profile is derived for the region near the north magnetic pole, from which quantitative abundance estimates of minor species are made. Some species previously detected on Jupiter, including CH3D, C2H2, and C2H6, have been observed again near the pole. Newly discovered species, not previously observed on Jupiter, include C2H4, C3H4, and C6H6. All of these species except CH3D appear to have enhanced abundances at the north polar region with respect to midlatitudes. Upper limits are determined for C4H2 and C3H8. The quantitative results are compared with model calculations based on ultraviolet results from the IUE satellite. The plausibility of the C6H6 identification is discussed in terms of the literature on C2H2 polymerization. The relation of C6H6 to cuprene is also discussed.

Kim, S. J.↗

Elemental analysis of a comet nucleus by passive gamma ray spectrometry from a penetrator

The Comet Rendezvous Asteroid Flyby (CRAF) spacecraft, to be launched in 1991, was designed to study the physical and chemical properties of cometary and asteroid bodies. It is proposed that these properties can be determined by utilizing a penetrator experiment delivery system aboard the CRAF, which would deliver a passive gamma ray spectrometer to the comet and determine the composition of subsurface materials. Results of calculations for a model comet (50 percent CI carbonaceous chrondrite, 50 percent ices) provide data on the expected gamma ray fluxes, the minimum detectable limits, and the detection uncertainties for 35 isotopes. These results confirm that this technique can determine the composition of both the rocky and ice components, and the rock-to-ice ratio in the nucleus. In addition, useful information regarding the formation of the solar system is provided.

Evans, L. G.↗

Detection of hydrothermal alteration at Virginia City, Nevada using Airborne Imaging Spectrometry (AIS)

Airborne Imaging Spectrometer (AIS) data were collected over Virginia City, Nevada; an area of gold and silver mineralization with extensive surface exposures of altered volcanic rocks. The data were corrected for atmospheric effects by a flat-field method, and compared to library spectra of various alteration minerals using a spectral analysis program SPAM. Areas of strong clay alteration were identified on the AIS images that were mapped as kaolinitic, illitic, and sericitic alterations zones. Kaolinitic alteration is distinguishable in the 2.1 to 2.4 and 1.2 to 1.5 micrometer wavelength regions. Montmorillonite, illite, and sericite have absorption features similar to each other at 2.2 micrometer wavelength. Montnorillonite and illite also may be present in varying proportions within one Ground Instantaneous Field of View (GIFOV). In general AIS data is useful in identifying alteration zones that are associated with or lie above precious metal mineralization at Virginia City.

Hutsinpiller, A.↗

Spectrometry: Report of panel

Spectroscopic measurements are required to define the spectral background and provide the detailed spectral information that is essential for the design of species-specific systems and the analysis of data obtained from them. This function of spectroscopic measurements is expected to be an important part of any tropospheric remote-sensing program, and both emission and absorption spectroscopy are relevant in this context. The data from such observations are of value to tropospheric science in their own right, during the initial phases while species-specific techniques and instruments are under development. In addition, there are a number of unresolved problems in tropospheric radiative transfer and spectroscopy which presently limit the accuracy and reliability of all remote sensing methods. Only through a supporting program of spectroscopic measurements can progress be made in improving the understanding of these aspects of radiative transfer and ultimately reaching the desired confidence in the accuracy to species-specific monitoring techniques.

Farmer, C. Barney↗