Search NASA⌕ Search

SEARCH · Search NASA

Results for “SSL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Restoring Detroit's Street Lighting System

The City of Detroit is in the midst of a comprehensive restoration of its street lighting system that includes transitioning the existing HPS sources to LED. This report provides an objective review of the circumstances surrounding the system restoration, the processes undertaken and decisions made, and the results so far — and contains useful information about issues that arise during large-scale LED street lighting projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: Philadelphia International Airport Apron Lighting: LED System Performance in a Trial Installation

This report documents a trial installation of LED apron lighting that replaced the existing high-pressure sodium luminaires at Philadelphia International Airport. Such high-mast applications remain challenging for LED technology, and the lessons learned from this project may help facility managers and LED product manufacturers better meet those challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: LED System Performance in a Trial Installation--Two Years Later, Yuma Border Patrol, Yuma, Arizona

Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial demonstration in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations at the Yuma Sector Border Patrol Area in Yuma, Arizona. The retrofit was documented to better understand LED technology performance in high-temperature environments. This report follows the GATEWAY Yuma Phase 1.1 Report and reflects LED system results documented two years after the demonstration began.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Report Brief: Tunable-White Lighting at the ACC Care Center

Summary of a GATEWAY program report that documented the performance of tunable-white LED lighting systems installed in several spaces within the ACC Care Center, a senior-care facility in Sacramento, CA. The project results included energy savings and improved lighting quality, as well as other possible health-related benefits that may have been attributable, at least in part, to the lighting changes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Report Brief: OLED Lighting in the Offices of Aurora Lighting Design, Inc.

Summary of a GATEWAY report evaluation at the offices of Aurora Lighting Design, Inc., in Grayslake, IL, where the GATEWAY program conducted its first investigation involving OLED lighting. The project experienced several challenges, but also highlighted a number of promising attributes – which indicate that with continued improvements in efficacy, longevity, size, and flexibility, OLEDs could provide a new tool for creative and effective lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: Tuning the Light in Senior Care: Evaluating a Trial LED Lighting System at the ACC Care Center in Sacramento, CA

The GATEWAY program documented the performance of tunable-white LED lighting systems installed in several spaces within the ACC Care Center, a senior-care facility in Sacramento, CA. The project results included energy savings and improved lighting quality, as well as other possible health-related benefits that may have been attributable, at least in part, to the lighting changes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: Tuning Hospital Lighting: Evaluating Tunable LED Lighting at the Swedish Hospital Behavioral Health Unit in Seattle

The GATEWAY program evaluated a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: OLED Lighting in the Offices of DeJoy, Knauf & Blood, LLP

At the offices of the accounting firm of DeJoy, Knauf & Blood, LLP in Rochester, NY, the GATEWAY program evaluated a new lighting system that incorporates a number of different OLED luminaires. Evaluation of the OLED products included efficacy performance, field measurements of panel color, flicker measurements, and staff feedback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: OLED Lighting in the Offices of Aurora Lighting Design, Inc.

At the offices of Aurora Lighting Design, Inc., in Grayslake, IL, the GATEWAY program conducted its first investigation involving OLED lighting. The project experienced several challenges, but also highlighted a number of promising attributes – which indicate that with continued improvements in efficacy, longevity, size, and flexibility, OLEDs could provide a new tool for creative and effective lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Application Summary Report 22: LED MR16 Lamps

An initial sample of 27 LED MR16 lamps and 8 halogen benchmarks underwent photometric testing according to IES LM-79-08. CALiPER Application Summary Report 22 focuses on the initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to the benchmarks and ENERGY STAR qualification thresholds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit

Summary of a GATEWAY report evaluation of a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

59 BASIC BIOLOGICAL SCIENCES↗

CALiPER Report 23: Photometric Testing of White Tunable LED Luminaires

This report documents an initial investigation of photometric testing procedures for white-tunable LED luminaires and summarizes the key features of those products. Goals of the study include understanding the amount of testing required to characterize a white-tunable product, and documenting the performance of available color-tunable luminaires that are intended for architectural lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of an LED Retrofit Project at Princeton University's Carl Icahn Laboratory

At Princeton University’s Carl Icahn Laboratory, DOE’s Commercial Buildings Integration Program documented the implementation of LED retrofit products for recessed troffers, linear cove lighting, and downlights – as part of Princeton’s first building-wide interior LED project. The conversion to LED enables more extensive use of lighting controls to tailor the lighting to the task and limit the operating hours based on occupancy, and the estimated energy savings including controls is 62% compared to the incumbent system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Report: Tuning the Light in Classrooms: Evaluating Trial LED Lighting Systems in Three Classrooms at the Carrollton-Farmers Branch Independent School District in Carrollton, TX

The GATEWAY program evaluated a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2015 U.S. Lighting Market Characterization

The latest version of the U.S. Lighting Market Characterization estimates the installed stock, energy use, and lumen production of all general-illumination lighting products operating in the U.S. in 2015. Latest update in an ongoing series of reports.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Lighting System Interoperability Study Part 1: Application Programming Interfaces

First in a series of studies that focuses on interoperability as realized by the use of Application Programming Interfaces (APIs), explores the diversity of such interfaces in several connected lighting systems; characterizes the extent of interoperability that they provide; and illustrates challenges, limitations, and tradeoffs that were encountered during this exploration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Lighting Systems Efficiency Study - PoE Cable Energy Losses, Part 1 [Revised]

First report in a study of the efficiency of connected lighting systems. The report summarizes the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines recently introduced by the American National Standards Institute (ANSI) C137 Lighting Systems Committee.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Yuma Border Patrol Lighting Retrofit: Final LED System Performance Assessment of Trial and Full Installation

Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial evaluation in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations, and illuminance measurements were recorded initially and at 2500 hours, 5000 hours, 7000, and 11,000 hours of operation. Additionally, four second-generation LED luminaires installed as part of the full installation were evaluated initially and again after 4,000 hours of operation. While the initial energy, lighting quality, and maintenance benefits relative to the incumbent high-pressure sodium system were very satisfactory, the study raises important questions regarding the long-term performance of LED lighting systems in high-temperature environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗