Search NASA⌕ Search

SEARCH · Search NASA

Results for “Salt Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Analysis of dust samples collected from spent nuclear fuel interim storage containers at Hope Creek, Delaware, and Diablo Canyon, California

Potentially corrosive environments may form on the surface of spent nuclear fuel dry storage canisters by deliquescence of deposited dusts. To assess this, samples of dust were collected from in-service dry storage canisters at two near-marine sites, the Hope Creek and Diablo Canyon storage installations, and have been characterized with respect to mineralogy, chemistry, and texture. At both sites, terrestrially-derived silicate minerals, including quartz, feldspars, micas, and clays, comprise the largest fraction of the dust. Also significant at both sites were particles of iron and iron-chromium metal and oxides generated by the manufacturing process. Soluble salt phases were minor component of the Hope Creek dusts, and were compositionally similar to inland salt aerosols, rich in calcium, sulfate, and nitrate. At Diablo Canyon, however, sea-salt aerosols, occurring as aggregates of NaCl and Mg-sulfate, were a major component of the dust samples. The seasalt aerosols commonly occurred as hollow spheres, which may have formed by evaporation of suspended aerosol seawater droplets, possibly while rising through the heated annulus between the canister and the overpack. The differences in salt composition and abundance for the two sites are attributed to differences in proximity to the open ocean and wave action. The Diablo Canyon facility is on the shores of the Pacific Ocean, while the Hope Creek facility is on the shores of the Delaware River, several miles from the open ocean.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of solids deposited on the modular caustic-side solvent extraction unit (MCU) coalescer media removed in May and October 2014

During routine maintenance, the coalescers utilized in the Modular Caustic-Side Solvent Extraction Unit (MCU) processing of Salt Batch 6 and a portion of Salt Batch 7 were sampled and submitted to the Savannah River National Laboratory (SRNL) for characterization, for the purpose of identifying solid phase constituents that may be accumulating in these coalescers. Specifically, two samples were received and characterized: A decontaminated salt solution (DSS) coalescer sample and a strip effluent (SE) coalescer sample. Aliquots of the samples were analyzed by XRD, Fourier Transform Infrared (FTIR) Spectroscopy, SEM, and EDS. Other aliquots of the samples were leached in acid solution, and the leachates were analyzed by ICP-AES. In addition, modeling was performed to provide a basis for comparison of the analytical results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Defense waste processing facility (DWPF) liquids model: revisions for processing higher TIO 2 containing glasses

Radioactive high level waste (HLW) at the Savannah River Site (SRS) has successfully been vitrified into borosilicate glass in the Defense Waste Processing Facility (DWPF) since 1996. Vitrification requires stringent product/process (P/P) constraints since the glass cannot be reworked once it is poured into ten foot tall by two foot diameter canisters. A unique “feed forward” statistical process control (SPC) was developed for this control rather than statistical quality control (SQC). In SPC, the feed composition to the DWPF melter is controlled prior to vitrification. In SQC, the glass product would be sampled after it is vitrified. Individual glass property-composition models form the basis for the “feed forward” SPC. The models transform constraints on the melt and glass properties into constraints on the feed composition going to the melter in order to guarantee, at the 95% confidence level, that the feed will be processable and that the durability of the resulting waste form will be acceptable to a geologic repository. This report documents the development of revised TiO 2 , Na 2 O, Li 2 O and Fe 2 O 3 coefficients in the SWPF liquidus model and revised coefficients (a, b, c, and d).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-18-123- 125 (April 2018), MCU-18-135-137 (May 2018), and MCU-18-192-197(June 2018): Quarterly Report

A trend summary of three Solvent Hold Tank (SHT) monthly samples MCU-18-123-125, MCU-18-135- 137, and MCU-18-192-197 are reported. Most of the conclusions are based on the June SHT sample (MCU- 18-192-197). Analyses of the June SHT sample (MCU-18-192-197) indicated that the Modifier (CS-7SB) and the extractant (MaxCalix) concentrations were at the nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively). The suppressor ( N,N’,N” –tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 1,116 mg/L, well above the minimum recommended concentration (479 mg/L), but below the nominal concentration. The apparent “downwards” trends observed in the TiDG, MaxCalix, Modifier, and gamma measurement are consistent with the start up (and/or proficiency runs) of MCU on May 22, 2018 since these new concentrations are consistent with the concentrations observed when MCU was fully operational in 2016.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crystalline Silicotitanate ion exchange media long-term storage evaluation

Crystalline Silicotitanate a (CST) ion exchange media is produced in an engineered form, known as IONSIV™ IE-911. This material has been tested extensively for use in removing 137 Cs from Savannah River Site (SRS) and Hanford site tank waste. This inorganic material is highly selective for removing cesium ions, even in the presence of high concentrations of sodium and potassium ions and is tolerant of the harsh conditions of the varying tank chemistries. A batch of caustic washed IE-911 that had been produced by the supplier and received at SRS in 2001 was tested to verify that it was still in good condition after the extended storage. This testing involved standard batch contacts to measure the removal of Cs from simulated tank waste. This report describes the results of testing performed to verify that the IE-911 matches the performance of previous batches of this media. To confirm that the performance of IE-911 is similar to previous batches and that no degradation had occurred during storage, batch contact testing was performed using SRNL’s standard methodology using a non-radioactive SRS Average Waste Simulant composition utilized in previous studies. Batch contact kinetics testing was also conducted to determine cesium loading on this batch versus time. The cesium equilibrium loading isotherm in SRS simulant at 23°C was compared to ZAM isotherm model predictions and previous test results with IE-911 media. The measured and predicted distribution coefficients and cesium loading (“Q”) are shown in Table ES-1. The physical properties of the material were also determined, including density, moisture content, and particle size.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the Supplementary Analyses of Salt Batch 10 and 11 Samples

Supplementary analyses of material from the Interim Salt Disposition Project (ISDP) Salt Batch (SB) 10 and Salt Batch 11 (SB11) samples were analyzed beyond what is described in previous reports. These additional analyses are required to verify these materials meet Salt Waste Processing Facility (SWPF) Waste Acceptance Criteria (WAC) feed requirements. The stored SB10 and SB11 samples have been analyzed without filtering and the results found to be very similar to the previous filtered analyses performed for SB10 and SB11. The only result of significant difference is the wt% insoluble solids result for the SB11 sample. It would appear the newer method of analyzing larger volumes gives more accurate measurements for solutions with low quantities of solids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls from the Tank 49H B4 downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. The scope of this task is to perform fluid flow analysis to determine the impact of a “plunging jet” through the B4 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF.

54 ENVIRONMENTAL SCIENCES↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Literature Review on the Impact of Thermolytic Hydrogen Generation Rate from the Next Generation Solvent

A literature review was undertaken to assess the thermolytic hydrogen generation potential of the Next Generation Solvent (NGS) system, which is planned to replace the Original Caustic-Side Solvent Extraction (CSSX) Solvent at the Salt Waste Processing Facility. NGS uses a new extractant and suppressor and the same modifier and organic carrier solvent as the Original CSSX Solvent at different concentrations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of the Literature on the Radiolytic Stability of the Next-Generation Solvent

The Original Caustic-Side Solvent Extraction (CSSX) solvent (based on the BOBCalixC6 extractant) currently in use at the Salt Waste Processing Facility (SWPF) is set to be replaced by the Next-Generation Solvent (NGS, based on the MaxCalix extractant). Current SWPF flammability safety controls use G-values for volatile gases obtained from radiolysis studies with the Original CSSX solvent. A review of past irradiation tests of both solvent systems was performed to assess the radiolytic stability of NGS with respect to flammable gas generation from radiolysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Literature Review on Next Generation Solvent Isopar ® L Vapor Pressure Curve and the Partitioning of its Modifier and Extractant

The Next Generation Solvent (NGS) is set to replace the Original Caustic Side Solvent Extractant (CSSX) at the Salt Waste Processing Facility (SWPF). The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC), formerly Savannah River Remediation (SRR), to perform a literature review on the following topics to address flammability concerns with the current solvent: Isopar ® L vapor pressure curve for NGS, partitioning ratio for the extractant MaxCalix and the modifier Cs-7SB, and high cesium concentration impacts on NGS radiolysis and potential solvent degradation rates in high cesium concentrations. The following conclusions and recommendations are made based on previous experimental work and literature: (1) Current SWPF flammable gas generation calculations use an Isopar ® L vapor pressure curve based on experimental testing with the Original CSSX solvent. No such testing to date has been performed with NGS. It is suggested that the decrease in Cs-7SB concentration for NGS compared to the Original CSSX solvent would lead to a slightly higher vapor pressure at all temperatures in SWPF vessels. A bounding NGS vapor pressure curve has been provided; it is recommended to see if these values would challenge current flammability controls and to perform testing if needed.(2) The partitioning ratio for Cs-7SB is known in the Original CSSX solvent with dilute nitric acid and caustic solutions. No tests could be found for the partitioning of Cs-7SB to dilute boric acid solutions; however, a similar partitioning ratio is expected. Due to the lipophilic alkyl chains on MaxCalix, it is expected to be even less soluble than BOBCalixC6 in the aqueous phase and should not be considered a significant contributor to the f organic term. Additionally, the reaction rate of N,N’,N’’-Tris(3,7-dimethyloctyl)guanidine (TiDG) or its degradation products with a hydrogen radical should be estimated/determined if they are found to be significant contributors to the f organic term. (3) NGS is expected to see much higher Cs concentrations at SWPF in comparison to its use at the Modular CSSX Unit (MCU). These higher Cs concentrations could influence radiolytic degradation rates of the solvent. NGS appears to be fairly stable to radiolytic degradation based on previous testing and its use at MCU. However, there has not been radiolytic flammable gas generation testing with NGS to date. There is a risk that the continued use of G-values obtained for flammable gases produced from the irradiation of the Original CSSX solvent is not bounding for NGS, but this is considered a very low risk due to the similarities in the composition of the solvents, as well as the conservatisms in the experimental design of the Original CSSX testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the Analyses of the SRNL Solvent Components

At the request of the Savannah River Mission Completion (SRMC), personnel at Savannah River Site (SRS) performed analyses on the remaining solvent components that are being stored at the Savannah River National Laboratory (SRNL). This was done to determine if the remaining stock of materials were still suitable for use for the Salt Waste processing Facility (SWPF). Two drums of Modifier, two drums BOBCalix, four drums of MAXCalix, and four jars of TiDG*HCl were analyzed. All were found to be of acceptable purity for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H solids disturbance analysis

Tank 49H serves as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb any solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L of the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer could potentially disturb any solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine whether accounting for disturbed particle settling and particle mixing and dispersion during transfer could allow the minimum liquid level to be reduced below 120 inches. The analysis utilized models from the technical literature to calculate the size and shape of the “plunging jet” as a function of input parameters such as initial velocity, initial jet diameter, elevation of the initial jet, liquid level in the tank, and solids depth. The analysis relied on the M-Star® simulations performed for the previous analysis to provide bounding estimates of the amount of solid particles disturbed and used the MStar® software to calculate the dispersion and mixing of the disturbed solids with other liquid in the tank as the solids are transported to the transfer pump. The analysis showed that with a solid particle size of 5 micron or less, a liquid level of 120 inches should be maintained to prevent significant disturbance of the solid layer at the bottom of Tank 49H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Generation Solvent Vapor Pressure Testing

Previous work by Savannah River National Laboratory (SRNL) indicated that the actual Next Generation Solvent vapor pressure would be higher than the Original Caustic Side Solvent Extraction (CSSX) solvent vapor pressure, but below a bounding vapor pressure using Raoult’s Law. Since solvent vapor pressure has a significant impact on Composite Lower Flammability Limits (CLFL) and attendant accident analyses, obtaining an additional margin from the bounding NGS vapor pressure would be valuable. In order to quantify how much margin might be gained from the NGS bounding solvent, SRNL researchers were requested to perform vapor pressure testing with the Next Generation Solvent (NGS) by Savannah River Mission Completion (SRMC). The vapor pressure curve for the NGS formulation set to be deployed at the Salt Waste Processing Facility (SWPF) has been determined by SRNL up to 55°C (131°F) using headspace Gas Chromatography (GC). It was expected that NGS would have a higher vapor pressure than the Original CSSX solvent; however, experimental results indicate a lower vapor pressure. At this time, it is uncertain if this difference is due to the 7x increase in concentration of the large calixarene in the solvent (0.007M BOBCalix in Original CSSX solvent vs. 0.05M MaxCalix in NGS) or to minor batch-to-batch variations in Isopar-L constituents. The NGS and the Original CSSX solvent vapor pressure data were fitted to the Antoine Equation. The Antoine equation gives a more accurate representation of the expected vapor pressure of the solvents outside of the temperature range tested. The Antoine equation fitting for NGS is given below: $P=10^{6.364⁻\frac{1788.4}{T+219.3}}$. Where, p is the vapor pressure (partial pressure) of NGS in mmHg and T is the temperature in °C. It is recommended that SRMC either continue using the more conservative Isopar-L vapor pressure calculations at SWPF with the equation developed for the Original CSSX solvent, or the equation presented above for the NGS solvent. Additionally, it is recommended to study the variability in Isopar-L vapor pressure between lots.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Compatibility of Tefzel™ and Viton™ B with Caustic-Side Solvent Extraction Solvents

The Salt Waste Processing Facility (SWPF) plans to switch from the current Caustic-Side Solvent Extraction (CSSX) solvent to the Next Generation Solvent-Phase II (NGS-Phase II). SRNL was requested to evaluate the compatibility between polymeric materials of construction at SWPF and NGS-Phase II solvent. The work presented here concentrated on two materials of interest: Tefzel™ and Viton™ B.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the IBC BOBCalix Solvent Samples

A second vendor for solvent extraction components has been chosen for use at the Salt Waste Processing Facility (SWPF). IBC Advanced Technologies (IBC) has provided samples of their BOBCalix, as well as complete solvent. These samples were tested for quality assurance purposes to ensure their use at SWPF is acceptable. Two Extraction, Scrub, and Strip (ESS) tests were performed on solvent samples from IBC. The purpose of testing these samples was to determine if the solvents are displaying the correct extraction and stripping behavior with cesium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗