Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory↗

Characterization of a radiation detector based on opaque water-based liquid scintillator

Here, we present the characterization of a novel radiation detector based on an opaque water-based liquid scintillator. Opaque scintillators, also known as LiquidO, are made to be highly scattering, such that the scintillation light is effectively confined, and read out through wavelength-shifting fibers. The 1-liter, 32-channel prototype demonstrates the capability for both spectroscopy and topological reconstruction of point-like events. The design, construction, and evaluation of the detector are described, including modeling of the scintillation liquid optical properties and the detector’s response to gamma rays of several energies. A mean position reconstruction error of 4.4 mm for 1.6 MeV-equivalent events and 7.4 mm for 0.8 MeV-equivalent events is demonstrated using a simple reconstruction approach analogous to center-of-mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

The Monte Carlo simulation of the Borexino detector

Borexino is a 300 ton sub-MeV liquid scintillator solar neutrino detector which has been running at the Laboratori Nazionali del Gran Sasso (Italy) since 2007. Thanks to its unprecedented radio-purity, it was able to measure the flux of 7 Be, 8 B, pp, and pep solar neutrinos and to detect geo-neutrinos. A reliable simulation of the detector is an invaluable tool for all Borexino physics analyses. The simulation accounts for the energy loss of particles in all the detector components, the generation of the scintillation photons, their propagation within the liquid scintillator volume, and a detailed simulation of the electronics chain. A novel efficient method for simulating the external background which survives the Borexino passive shield was developed. This technique allows to reliably predict the effect of the contamination in the peripheral construction materials. The techniques developed to simulate the Borexino detector and their level of refinement are of possible interest to the neutrino and dark matter communities, especially for current and future large-volume liquid scintillator experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the angular distribution of wavelength-shifted light emitted by TPB

We present measurements of the angular distribution of re-emitted light from tetraphenyl butadiene thin films when exposed to 128 nm light, which is the peak of the liquid Argon (LAr) scintillation spectrum, in vacuum. Films ranging from 250 nm to 5.5 μm in thickness are measured. All films were fabricated by evaporation deposition on ultraviolet transmitting (UVT) acrylic substrates. Preliminary comparisons of the angular distribution to that produced by a detailed Monte Carlo model are also presented. The current shortcomings of the model are discussed and future plans briefly outlined.

47 OTHER INSTRUMENTATION↗

The ATIC Experiment : Performance of the Scintillator Hodoscope and the BGO Calorimeter

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its first flight from McMurdo, Antarctica, 28/12/00 to 13/01/01, recording over 360 hours of data. The design goal for ATIC was to measure the Cosmic Ray composition and energy spectra from approximately 50 GeV to near 100 TeV utilizing a Si-matrix detector, a scintillator hodoscope, carbon targets and a calorimeter consisting of a stack of BGO scintillator crystals. The design, operation, and in-flight performance of the scintillator hodoscope and the BGO calorimeter are described.

Isbert, J.↗

The ATIC Experiment: Performance of the Scintillator Hodoscopes and the BGO Calorimeter

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its first flight from Mcmurdo, Antarctica 28/12/2000 to 13/01/2001, local time, recording over 360 hours of data. The design goal of ATIC was to measure the Cosmic Ray composition and energy spectra from approximately 50 GeV to near 100 TeV utilizing a Si-matrix detector, a scintillator hodoscope, carbon targets and a calorimeter consisting of a stack of BGO scintillator crystals. The design, the operations and in-flight performance of the scintillator hodoscope and the BGO calorimeter are described.

Isbert, Joachim↗

Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector

To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and 0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. In order to bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. Overall, this enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proof-of-concept of a neutron time-of-flight ellipsoidal detector

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

Jeet, J. (ORCID:0000000291091563)↗

Effect of an electric field on liquid helium scintillation produced by fast electrons

The dependence on applied electric field (0–40 kV/cm) of the scintillation light produced by fast electrons and α particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations and has a dependence on the energy of the primary ionization electron. Here, we discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the Hamamatsu 8-inch R14688-100 PMT

Large-scale optical neutrino and dark-matter detectors rely on large-area photomultiplier tubes (PMTs) for cost-effective light detection. The new R14688-100 8-inch PMT developed by Hamamatsu provides state-of-the-art timing resolution of around 1 ns (FWHM), which can help improve vertex reconstruction and enable Cherenkov and scintillation light separation in scintillation-based detectors. This PMT also provides excellent charge resolution, allowing for precision photoelectron counting and improved energy reconstruction. The Eos experiment is the first large-scale optical detector to utilize these PMTs. Here, in this manuscript, we present a characterization of the R14688-100 single photoelectron response, such as the transit-time spreads, the dark-rates, and the afterpulsing. The single photoelectron response measurements are performed for the 206 PMTs that will be used in Eos.

47 OTHER INSTRUMENTATION↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron time-of-flight detectors (nTOF) used at Sandia’s Z-Machine

Neutron time-of-flight (nTOF) detectors have been used on Sandia National Laboratories’ Z-Machine for inertial confinement fusion and magnetized liner fusion experiments to infer physics parameters including the apparent fuel-ion temperature, neutron yield, the magnetic-radius product (BR), and the liner rho-r. Single-paddle, dual-paddle, and co-axial scintillation nTOF detectors are used in axial lines-of-sight (LOS) and LOS that are 12° from the midplane. Detector fabrication, characterization, and calibration are discussed.

Chandler, G. A. (ORCID:0000000219640927)↗

Micro-Fabricated Solid-State Radiation Detectors for Active Personal Dosimetry

Active radiation dosimetry is important to human health and equipment functionality for space applications outside the protective environment of a space station or vehicle. This is especially true for long duration missions to the moon, where the lack of a magnetic field offers no protection from space radiation to those on extravehicular activities. In order to improve functionality, durability and reliability of radiation dosimeters for future NASA lunar missions, single crystal silicon carbide devices and scintillating fiber detectors are currently being investigated for applications in advanced extravehicular systems. For many years, NASA Glenn Research Center has led significant efforts in silicon carbide semiconductor technology research and instrumentation research for sensor applications under extreme conditions. This report summarizes the technical progress and accomplishments toward characterization of radiation-sensing components for the recommendation of their fitness for advanced dosimetry development.

Wrbanek, John D.↗

NOvA as a Supernova Observatory

Extra-solar system neutrino astronomy was born in February 1987 when a supernova in a nearby satellite galaxy deposited a couple dozen neutrino events across three solar neutrino and nucleon decay experiments. This marked the first-ever observation of supernova neutrinos, as well as the first supernova in our galactic neighborhood visible to the naked eye in nearly 400 years. There is still much we do not know about the dynamics of these powerful explosions, but one thing is certain: neutrinos play a central role in driving a supernova. They also provide a unique opportunity for probing the interior conditions of a collapsing stellar core. Since 1987, the number of neutrino detectors around the world has grown. When the next supernova occurs, detectors must be ready to seize the moment and record data from this rare event that only happens a couple times per century. The NOvA experiment has been prepared for this for some time, but it has been unclear how well NOvA will be ab le to se parate supernova-like events from the large cosmogenic backgrounds and extract meaningful physical insight. In this thesis, I show that the cosmic-induced backgrounds in the NOvA detectors---especially the far detector---can be reduced to an acceptable level for core-collapse supernovae within $\sim$15 kpc and that a determination of the neutrino mass ordering can be made for nearby supernovae under certain conditions. This thesis paves the way for future sensitivity studies and eventual analyses of real supernova data, and shows that NOvA's liquid scintillator neutrino detectors are a capable supernova observatory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NOvA as a Supernova Observatory

Extra-solar system neutrino astronomy was born in February 1987 when a supernova in a nearby satellite galaxy deposited a couple dozen neutrino events across three solar neutrino and nucleon decay experiments. This marked the first-ever observation of supernova neutrinos, as well as the first supernova in our galactic neighborhood visible to the naked eye in nearly 400 years. There is still much we do not know about the dynamics of these powerful explosions, but one thing is certain: neutrinos play a central role in driving a supernova. They also provide a unique opportunity for probing the interior conditions of a collapsing stellar core. Since 1987, the number of neutrino detectors around the world has grown. When the next supernova occurs, detectors must be ready to seize the moment and record data from this rare event that only happens a couple times per century. The NOvA experiment has been prepared for this for some time, but it has been unclear how well NOvA will be ab le to se parate supernova-like events from the large cosmogenic backgrounds and extract meaningful physical insight. In this thesis, I show that the cosmic-induced backgrounds in the NOvA detectors---especially the far detector---can be reduced to an acceptable level for core-collapse supernovae within $\sim$15 kpc and that a determination of the neutrino mass ordering can be made for nearby supernovae under certain conditions. This thesis paves the way for future sensitivity studies and eventual analyses of real supernova data, and shows that NOvA's liquid scintillator neutrino detectors are a capable supernova observatory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing individual single atom electrocatalyst sites by advanced analytical scanning transmission electron microscopy

Single atom electrocatalysts (SAEs) are promising next-generation materials for promoting a variety of important reactions, such as the oxygen reduction, nitrogen reduction, and CO 2 reduction reactions. While bulk characterization techniques such as X-ray absorption spectroscopy and Mössbauer spectroscopy have significantly enhanced our understanding of these catalysts, direct probing of individual single metal atom sites at the atomic scale is necessary to understand local variations in the properties of these sites and accelerate design and synthesis of improved SAEs. Aberration-corrected scanning transmission electron microscopy (STEM) has become a powerful tool for providing this type of atomic-scale information about SAE metal sites. These sites are typically unstable under the electron beam, however, which, in combination with conventional acquisition methods and detectors, has limited the type and quantity of information obtainable by spectroscopic STEM techniques. Here, we map multiple individual SAE metal sites in a nitrogen-doped carbon containing atomically dispersed Fe and Re (FeReNC) at the atomic scale by direct electron detection electron energy-loss spectroscopy (EELS). Direct electron detection provides an improved signal-to-noise ratio over conventional scintillator-based detectors and enables detection and real space localization of weak signals. In addition, we demonstrate an automated method for identification of metal atom positions, placement of the probe on these sites, and simultaneous EELS and energy dispersive X-ray spectroscopic (EDS) signal acquisition. This simultaneous acquisition of EELS and EDS provides access to the composition and bonding of a wide range of SAE metal sites. In this study, focusing the probe directly on the metal sites also increases the relevant data acquisition rate by more than an order of magnitude over two-dimensional mapping, enabling improved statistical measurements of site properties. The versatility, sensitivity, and speed that these techniques provide enhances our ability to probe the local elemental and chemical environment of a large number of individual SAE metal site structures at the atomic scale, enabling an improved understanding of the variations in the local properties of these electrocatalysts to be gained. As a result, significantly increased information about individual metal sites will be available to future electrochemical studies through these techniques, accelerating the development of advanced SAEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗