Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensing error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

THE ROTATING MOLECULAR STRUCTURES AND THE IONIZED OUTFLOW ASSOCIATED WITH IRAS 16547-4247

We present Very Large Array 1.3 cm radio continuum and water maser observations as well as Submillimeter Array SO{sub 2} (226.300 GHz) and 1.3 mm dust continuum observations toward the massive star formation region IRAS 16547-4247. We find evidence of multiple sources in the central part of the region. There is evidence of a rotating structure associated with the most massive of these sources, traced at small scales ({approx}50 AU) by the water masers. At large scales ({approx}1000 AU), we find a velocity gradient in the SO{sub 2} molecular emission with a barely resolved structure that can be modeled as a rotating ring or two separate objects. The velocity gradients of the masers and of the molecular emission have the same sense and may trace the same structure at different size scales. The position angles of the structures associated with the velocity gradients are roughly perpendicular to the outflow axis observed in radio continuum and several molecular tracers. We estimate the mass of the most massive central source to be around 30 solar masses from the velocity gradient in the water maser emission. The main source of error in this estimate is the radius of the rotating structure. We also find water masers that are associated with the large-scale molecular outflow of the system, as well as water masers that are associated with other sources in the region. Our results suggest that the formation of this source, one of the most luminous protostars or protostellar clusters known, is taking place with the presence of ionized jets and disk-like structures.

79 ASTRONOMY AND ASTROPHYSICS↗

On-line monitoring for static and dynamic performance verification of I and C systems at Sizewell B nuclear power station - 329

Plant operations and maintenance (O and M) activities account for nearly 75% of the generation cost of a modern nuclear power plant (NPP). This is largely due to time-based maintenance strategies that are expensive, time-consuming, prone to error, and sometimes detrimental to plant equipment. In contrast, condition-based maintenance via on-line monitoring (OLM) can reduce costs, increase equipment availability, and improve safety. OLM uses signals from existing plant sensors to verify the performance of plant instrumentation and equipment while the plant is operating. The Sizewell B nuclear power station in the United Kingdom, a four-loop pressurized water reactor (PWR), uses OLM techniques for several condition-based performance verification activities including pressure, level, and flow transmitter calibration monitoring, resistance temperature detector (RTD) cross calibration, and dynamic performance monitoring of pressure, level, and flow sensing systems. The implementation of OLM has enabled the plant to extend the calibration intervals of its pressure, level, and flow transmitters from 18 to 54 months and has significantly reduced the amount of critical path time needed to perform RTD cross calibration testing (up to 36 hours). Dynamic performance monitoring of its pressure, level, and flow transmitters with OLM has enabled the plant to monitor transmitter and sensing line response degradation while the plant is operating at 100% power and has dramatically reduced testing time versus the traditional hydraulic ramp testing method. The Sizewell B OLM implementation provides valuable insights into on how to overcome the technical and regulatory challenges for widespread OLM adoption by the nuclear industry. This paper describes the technical and regulatory aspects of this implementation and includes detailed examples of static and dynamic performance testing results to demonstrate the types of capabilities of OLM. Analyzing existing signals with OLM technologies can provide significant cost and safety benefits for the existing fleet of nuclear power plants. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improved sensing of vertical velocity for vertical position control using loop voltage signals on EAST

Vertical position control of shaped plasma is critical for all elongated tokamaks to achieve safe and stable plasma discharge. In EAST, the in-vessel coil (IC) is employed for fast control of plasma vertical motion which power supply capabilities limits the controllability of vertical instability. Moreover, adequate signal-to-noise ratio of vertical position measurement can also realize an improvement in vertical control. In EAST, plasma vertical position Z p is produced nearly by all integrated magnetics, fast Z error signal is obtained by filtering from Zp. Then this fast Z error and its derivative term (dz/dt) are controlled by IC with a separate PD controller. Yet, it has a low signal-to-noise ratio which limits the gains that can be used successfully in the PD control loops. To provide less noisy dz/dt signal, the successful use of multiple up/down loop voltage pairs instead of derivative of z derived from magnetic probe signals will be discussed. Experiment show that even a single pair of loop voltage signal has better signal-to-noise ratio than differentiation of Z p . In addition, flux loop pickup signals from the IC current are also measured with series of positive and negative IC current pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

The reliability of computational fluid dynamics (CFD) codes is checked by comparing simulations with experimental data. A typical data set consists chiefly of velocity and temperature readings, both ideally having high spatial and temporal resolution to facilitate rigorous code validation. While high resolution velocity data is readily obtained through optical measurement techniques such as particle image velocimetry, it has proven difficult to obtain temperature data with similar resolution. Traditional sensors such as thermocouples cannot fill this role, but the recent development of distributed sensing based on Rayleigh scattering and swept-wave interferometry offers resolution suitable for CFD code validation work. Thousands of temperature measurements can be generated along a single thin optical fiber at hundreds of Hertz. Sensors function over large temperature ranges and within opaque fluids where optical techniques are unsuitable. But this type of sensor is sensitive to strain and humidity as well as temperature and so accuracy is affected by handling, vibration, and shifts in relative humidity. Such behavior is quite unlike traditional sensors and so unconventional installation and operating procedures are necessary to ensure accurate measurements. This paper demonstrates implementation of a Rayleigh scattering-type distributed temperature sensor in a thermal mixing experiment involving two air jets at 25 and 45 °C. We present criteria to guide selection of optical fiber for the sensor and describe installation setup for a jet mixing experiment. We illustrate sensor baselining, which links readings to an absolute temperature standard, and discuss practical issues such as errors due to flow-induced vibration. This material can aid those interested in temperature measurements having high data density and bandwidth for fluid dynamics experiments and similar applications. We highlight pitfalls specific to these sensors for consideration in experiment design and operation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation into the Development and Testing of a Simplex Capacitance Sensor for Rotor Tip Clearance Measurement in Turbo Machinery

The rotor tip clearance is a vital parameter to characterize turbomachinery performance. It is an essential measurement during engine development and testing. The efficiency of the major modules like fan, compressor and turbine depends on the optimum running clearances. The capacitive sensor is preferred for tip clearance measurements because of various inherent advantages. They are fabricated through complex processes for turbomachinery application and are expensive. These sensors are exposed to harsh engine environments and are likely to exhibit degraded performance. Insulation failure at sensing head, connector contamination and micro-cracks in the MI (Mineral Insulated) cable leads to noise in the signal output. Frequent mechanical failures are also seen due to work hardening of MI cables, lead connector detachments and failure of micro fins at interconnects. Fault fixing of these is tedious and very expensive. This paper presents the concerted effort in developing a simple capacitance sensor addressing potential sensor failure issues. The design features include simple construction, ease of sensor assembly, component realization and troubleshooting. The design also addresses all safety requirements. The sensor has a large sensing area (7.6 mm diameter) producing very stable, high-level signal. The developed sensor produces output that varies from 1 V{sub P-P} to 11 V{sub P-P} for blade-tip gaps between 3 mm to 0.4 mm respectively. Blade pass simulation studies across the sensor, display almost flat response at minimum clearance. This feature results in very minimal data acquisition errors. The sensor along with RC (Resistance-Capacitance) conditioning electronics was successfully used for clearance measurement on fan stage of gas turbine engine. Test results are in line with the predictions. Extensive tip clearance measurements on the engine validate the design. The current work provides an insight into the development of a simplex capacitance sensor for tip clearance measurement.

42 ENGINEERING↗

Discrimination of Temperature and Strain in Brillouin Optical Time Domain Analysis Using a Multicore Optical Fiber

Brillouin optical time domain analysis is the sensing of temperature and strain changes along an optical fiber by measuring the frequency shift changes of Brillouin backscattering. Because frequency shift changes are a linear combination of temperature and strain changes, their discrimination is a challenge. Here, a multicore optical fiber that has two cores is fabricated. The differences between the cores’ temperature and strain coefficients are such that temperature (strain) changes can be discriminated with error amplification factors of 4.57 °C/MHz (69.11 μϵ /MHz), which is 2.63 (3.67) times lower than previously demonstrated. As proof of principle, using the multicore optical fiber and a commercial Brillouin optical time domain analyzer, the temperature (strain) changes of a thermally expanding metal cylinder are discriminated with an error of 0.24% (3.7%).

47 OTHER INSTRUMENTATION↗

UTILIZATION OF THE WAVEFRONT SENSOR AND SHORT-EXPOSURE IMAGES FOR SIMULTANEOUS ESTIMATION OF QUASI-STATIC ABERRATION AND EXOPLANET INTENSITY

Heretofore, the literature on exoplanet detection with coronagraphic telescope systems has paid little attention to the information content of short exposures and methods of utilizing the measurements of adaptive optics wavefront sensors. This paper provides a framework for the incorporation of the wavefront sensor measurements in the context of observing modes in which the science camera takes millisecond exposures. In this formulation, the wavefront sensor measurements provide a means to jointly estimate the static speckle and the planetary signal. The ability to estimate planetary intensities in as little as a few seconds has the potential to greatly improve the efficiency of exoplanet search surveys. For simplicity, the mathematical development assumes a simple optical system with an idealized Lyot coronagraph. Unlike currently used methods, in which increasing the observation time beyond a certain threshold is useless, this method produces estimates whose error covariances decrease more quickly than inversely proportional to the observation time. This is due to the fact that the estimates of the quasi-static aberrations are informed by a new random (but approximately known) wavefront every millisecond. The method can be extended to include angular (due to diurnal field rotation) and spectral diversity. Numerical experiments are performed with wavefront data from the AEOS Adaptive Optics System sensing at 850 nm. These experiments assume a science camera wavelength {lambda} of 1.1 {mu}, that the measured wavefronts are exact, and a Gaussian approximation of shot-noise. The effects of detector read-out noise and other issues are left to future investigations. A number of static aberrations are introduced, including one with a spatial frequency exactly corresponding the planet location, which was at a distance of Almost-Equal-To 3{lambda}/D from the star. Using only 4 s of simulated observation time, a planetary intensity, of Almost-Equal-To 1 photon ms{sup -1}, and a stellar intensity of Almost-Equal-To 10{sup 5} photons ms{sup -1} (contrast ratio 10{sup 5}), the short-exposure estimation method recovers the amplitudes' static aberrations with 1% accuracy, and the planet brightness with 20% accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal sensing on an asymmetric exceptional surface

We study the connection between exceptional points (EPs) and optimal parameter estimation, in a simple system consisting of two counterpropagating traveling wave modes in a microring resonator. The unknown parameter to be estimated is the strength of a perturbing cross-coupling between the two modes. Partially reflecting the output of one mode into the other creates a non-Hermitian Hamiltonian that exhibits a family of EPs, creating an exceptional surface (ES). We use a fully quantum treatment of field inputs and noise sources to obtain a quantitative bound on the estimation error by calculating the quantum Fisher information (QFI) in the output fields, whose inverse gives the Cramér-Rao lower bound on the mean-squared error of any unbiased estimator. We determine the bounds for two input states, namely, a semiclassical coherent state and a highly nonclassical NOON state. We find that the QFI is enhanced in the presence of an EP for both of these input states and that both states can saturate the Cramér-Rao bound. We then identify idealized yet experimentally feasible measurements that achieve the minimum bound for these two input states. We also investigate how the QFI changes for parameter values that do not lie on the ES, finding that these can have a larger QFI, suggesting alternative routes to optimize the parameter estimation for this problem.

Exceptional points↗

Enforcing the Courant–Friedrichs–Lewy condition in explicitly conservative local time stepping schemes

In this study, an optimally efficient explicit numerical scheme for solving fluid dynamics equations, or any other parabolic or hyperbolic system of partial differential equations, should allow local regions to advance in time with their own, locally constrained time steps. However, such a scheme can result in violation of the Courant-Friedrichs-Lewy (CFL) condition, which is manifestly non-local. Although the violations can be considered to be "weak" in a certain sense and the corresponding numerical solution may be stable, such calculation does not guarantee the correct propagation speed for arbitrary waves . We use an experimental fluid dynamics code that allows cubic "patches" of grid cells to step with independent, locally constrained time steps to demonstrate how the CFL condition can be enforced by imposing a condition on the time steps of neighboring patches. We perform several numerical tests that illustrate errors introduced in the numerical solutions by weak CFL condition violations and show how strict enforcement of the CFL condition eliminates these errors. In all our tests the strict enforcement of the CFL condition does not impose a significant performance penalty.

79 ASTRONOMY AND ASTROPHYSICS↗

Long distance fiber-optic displacement sensor based on fiber collimator

A simple fiber-optic displacement sensor based on reflective intensity modulated technology is demonstrated using a fiber collimator. The sensing range is over 30 cm, which is over 100 times that of the conventional fiber-optic displacement sensor based on the normal single-mode fiber. The measured data are fitted into linear equation very well and the values of R-square are more than 0.995. The sensitivity of the device achieves 0.426 dB/cm over the range of 5-30 cm. By applying the relative technique, the errors resulted from the fluctuation of light source and influences of environment are effectively eliminated, and the stability for wide range measurement can be improved. The simplicity of the design, high dynamic range, stability and the ease of the fabrication make it suitable for applications in industries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing the Delayed Gamma Capability in MCNP6

The mission of the Domestic Nuclear Detection Office is to quickly and reliably detect unauthorized attempts to import or transport special nuclear material for use against the United States. Developing detection equipment to meet this objective requires accurate simulation of both the detectable signature and detection mechanism. A delayed particle capability was initially added to MCNPX 2.6.A in 2005 to sample the radioactive fission product parents and emit decay particles resulting from the decay chain. To meet the objectives of detection scenario modeling, the capability was designed to sample a particular time for emitting particular multiplicity of a particular energy. Because the sampling process of selecting both time and energy is interdependent, to linearize the time and emission sampling, atom densities are computed at several discrete time steps, and the time-integrated production is computed by multiplying the atom density by the decay constant and time step size to produce a cumulative distribution function for sampling the emission time, energy, and multiplicity. The delayed particle capability was initially given a time-bin structure to help reasonably reproduce, from a qualitative sense, a fission benchmark by Beddingfield, which examined the delayed gamma emission. This original benchmark was only qualitative and did not contain the magnitudes of the actual measured data but did contain relative graphical representation of the spectra. A better benchmark with measured data was later provided by Hunt, Mozin, Reedy, Selpel, and Tobin at the Idaho Accelerator Center; however, because of the complexity of the benchmark setup, sizable systematic errors were expected in the modeling, and initial results compared to MCNPX 2.7.0 showed errors outside of statistical fluctuation. Presented in this paper is a more simplified approach to benchmarking, utilizing closed form analytic solutions to the granddaughter equations for particular sets of decay systems. We examine five different decay chains (two-stage decay to stable) and show the predictability of the MCNP6 delayed gamma feature. Results do show that while the default delayed gamma calculations available in the MCNP6 1.0 release can give accurate results for some isotopes (e.g., 137 Ba), the percent differences between the closed form analytic solutions and the MCNP6 calculations were often >40% ( 28 Mg, 28 Al, 42 K, 47 Ca, 47 Sc, 60 Co). With the MCNP6 1.1 Beta release, the tenth entry on the DBCN card allows improved calculation within <5% as compared to the closed form analytic solutions for immediate parent emissions and transient equilibrium systems. While the tenth entry on the DBCN card for MCNP6 1.1 gives much better results for transient equilibrium systems and parent emissions in general, it does little to improve daughter emissions of secular equilibrium systems. Finally, hypotheses were presented as to why daughter emissions of secular equilibrium systems might be mispredicted in some cases and not in others.

42 ENGINEERING↗

Modeling Subsurface Explosions Recorded on a Distributed Fiber Optic Sensor

Fiber optic distributed acoustic sensors (DAS) are becoming a widely used tool for seismic sensing. Here we examine recordings of two subsurface chemical explosions, DAG-1 and DAG-3, each of which was about one metric ton (TNT equivalent), that were recorded from a helical fiber installed in two boreholes 80 m away from the source location. Several clear phases including the initial P wave, a weak S wave, and a surface reflected P wave are observed on the helical DAS data. We estimate a velocity model using arrival times measured from the fiber. The DAS waveform data were compared with colocated accelerometers at specific depths in both frequency and time domains. Furthermore, the spectra of the DAS data matched spectra estimated from the accelerometer records. Comparisons of observed waveform shape between the accelerometer records and the fiber measurements (strain-rate) show reasonable agreement except for the data near the event depth. The DAS data and the accelerometer agreed in relative amplitudes but we had difficulties in matching absolute amplitudes, possibly due to errors in metadata. Synthetic strain-rate waveforms were calculated using a 2D wavenumber algorithm and matched the waveform shape and relative amplitudes. In general, DAS is effective at recording strong ground motions at high spatial density. Comparison of the synthetic seismograms with observed data indicate that the waveforms are not consistent with a pure isotropic explosion source and that the observed S waves originate from very near the source region.

58 GEOSCIENCES↗

Remote Sensing of Droplet Number Concentration in Warm Clouds: A Review of the Current State of Knowledge and Perspectives

Abstract The cloud droplet number concentration ( N d ) is of central interest to improve the understanding of cloud physics and for quantifying the effective radiative forcing by aerosol‐cloud interactions. Current standard satellite retrievals do not operationally provide N d , but it can be inferred from retrievals of cloud optical depth ( τ c ) cloud droplet effective radius ( r e ) and cloud top temperature. This review summarizes issues with this approach and quantifies uncertainties. A total relative uncertainty of 78% is inferred for pixel‐level retrievals for relatively homogeneous, optically thick and unobscured stratiform clouds with favorable viewing geometry. The uncertainty is even greater if these conditions are not met. For averages over 1° ×1° regions the uncertainty is reduced to 54% assuming random errors for instrument uncertainties. In contrast, the few evaluation studies against reference in situ observations suggest much better accuracy with little variability in the bias. More such studies are required for a better error characterization. N d uncertainty is dominated by errors in r e , and therefore, improvements in r e retrievals would greatly improve the quality of the N d retrievals. Recommendations are made for how this might be achieved. Some existing N d data sets are compared and discussed, and best practices for the use of N d data from current passive instruments (e.g., filtering criteria) are recommended. Emerging alternative N d estimates are also considered. First, new ideas to use additional information from existing and upcoming spaceborne instruments are discussed, and second, approaches using high‐quality ground‐based observations are examined.

58 GEOSCIENCES↗

Discrete Hahn polynomials for numerical solution of two-dimensional variable-order fractional Rayleigh–Stokes problem

The main aim of this paper is to find the numerical solutions of 2D Rayleigh–Stokes problem with the variable-order fractional derivatives in the Riemann–Liouville sense. The presented method is based on collocation procedure in combination with the new operational matrix of the variable-order fractional derivatives, in the Caputo sense, for the discrete Hahn polynomials. The main advantage of the proposed method is obtaining a global approximation for spatial and temporal discretizations, and it reduced the problem to an algebraic system, which is easier to solve. Also, the profit of approximating a continuous function by Hahn polynomials is that for computing the coefficients of the expansion, we only have to compute a summation and the calculation of coefficients is exact. The error bound for the approximate solution is estimated. Finally, we evaluate results of the presented method with other numerical methods.

97 MATHEMATICS AND COMPUTING↗

Optimal design of acoustic metamaterial cloaks under uncertainty

In this work, we consider the problem of optimal design of an acoustic cloak under uncertainty and develop scalable approximation and optimization methods to solve this problem. The design variable is taken as an infinite-dimensional spatially-varying field that represents the material property, while an additive infinite-dimensional random field represents the variability of the material property or the manufacturing error. Discretization of this optimal design problem results in high-dimensional design variables and uncertain parameters. To solve this problem, we develop a computational approach based on a Taylor approximation and an approximate Newton method for optimization, which is based on a Hessian derived at the mean of the random field. We show our approach is scalable with respect to the dimension of both the design variables and uncertain parameters, in the sense that the necessary number of acoustic wave propagations is essentially independent of these dimensions, for numerical experiments with up to one million design variables and half a million uncertain parameters. Additionally, we demonstrate that, using our computational approach, an optimal design of the acoustic cloak that is robust to material uncertainty is achieved in a tractable manner. The optimal design under uncertainty problem is posed and solved for the classical circular obstacle surrounded by a ring-shaped cloaking region, subjected to both a single-direction single-frequency incident wave and multiple-direction multiple-frequency incident waves. Finally, we apply the method to a deterministic large-scale optimal cloaking problem with complex geometry, to demonstrate that the approximate Newton method’s Hessian computation is viable for large, complex problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution Bayesian spatial autocorrelation (SPAC) quasi-3-D Vs model of Utah FORGE site with a dense geophone array

SUMMARY We expand the application of spatial autocorrelation (SPAC) from typical 1-D Vs profiles to quasi-3-D imaging via Bayesian Monte Carlo inversion (BMCI) using a dense nodal array (49 nodes) located at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site. Combinations of 4 and 9 geophones in subarrays provide for 36 and 25 1-D Vs profiles, respectively. Profiles with error bars are determined by calculating coherency functions that fit observations in a frequency range of 0.2–5 Hz. Thus, a high-resolution quasi-3-D Vs model from the surface to 2.0 km depth is derived and shows that surface-parallel sedimentary strata deepen to the west, consistent with a 3-D seismic reflection survey. Moreover, the resulting Vs profile is consistent with a Vs profile derived from distributed acoustic sensing (DAS) data located in a borehole at the FORGE site. The quasi-3-D velocity model shows that the base of the basin dips ∼22° to the west and topography on the basement interface coincident with the Mag Lee Wash suggests that the bedrock interface is an unconformity.

Geochemistry & Geophysics↗

Feynman diagrams for matter wave interferometry

We introduce a new theoretical framework based on Feynman diagrams to compute phase shifts in matter wave interferometry. The method allows for analytic computation of higher order quantum corrections, beyond the traditional semi-classical approximation. These additional terms depend on the finite size of the initial matter wavefunction and/or have higher order dependence on ℏ. We apply the method to compute the response of matter wave interferometers to power law potentials and potentials with an arbitrary spatial dependence. The analytic expressions are validated by comparing to numerical simulations, and estimates are provided for the scale of the quantum corrections to the phase shift response to the gravitational field of the earth, anharmonic trapping potentials, and gravitational fields from local proof masses. We also find that for certain experimentally feasible parameters, these corrections are large enough to be measured and could lead to systematic errors if they are not mitigated. We find that to first order in a spatially dependent potential, quantum corrections vanish when the initial matter wavepacket has spherical symmetry and the potential satisfies Laplace's equation. We anticipate these quantum corrections will be especially important for trapped matter wave interferometers and for free-space matter wave interferometers in the presence of proof masses. These interferometers are becoming increasingly sensitive tools for mobile inertial sensing, gravity surveying, tests of gravity and its interplay with quantum mechanics, and searches for dark energy.

Glick, Jonah [Northwestern U.; Fermilab] (ORCID:00↗

Utah FORGE: Seismic Velocity Models, February 2021

This dataset contains a map, showing the Utah FORGE seismic stations, and seismic velocity model data. There are 61 1-D velocity models which are in a compressed TAR file. A paper is referenced at the end of this description which discusses the use of these data in 3D modelling. The paper summary follows: We expand the application of spatial autocorrelation (SPAC) from typical 1-D Vs profiles to quasi-3-D imaging via Bayesian Monte Carlo inversion (BMCI) using a dense nodal array (49 nodes) located at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site. Combinations of 4 and 9 geophones in subarrays provide for 36 and 25 1-D Vs profiles, respectively. Profiles with error bars are determined by calculating coherency functions that fit observations in a frequency range of 0.2-5 Hz. Thus, a high-resolution quasi-3-D Vs model from the surface to 2.0 km depth is derived and shows that surface-parallel sedimentary strata deepen to the west, consistent with a 3-D seismic reflection survey. Moreover, the resulting Vs profile is consistent with a Vs profile derived from distributed acoustic sensing (DAS) data located in a borehole at the FORGE site. The quasi-3-D velocity model shows that the base of the basin dips ~22 degrees to the west and topography on the basement interface coincident with the Mag Lee Wash suggests that the bedrock interface is an unconformity. Reference: Zhang, H. and K. L. Pankow (2021). High-resolution Bayesian spatial auto-correlation (SPAC) pseudo-3D Vs model of Utah FORGE site with a dense geophone array, Geophys. Res. Int, https://doi.org/10.1093/gji/ggab049

15 GEOTHERMAL ENERGY↗