Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shoulders”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Friction Stir Welding of Tapered Thickness Welds Using an Adjustable Pin Tool

Friction stir welding (FSW) can be used for joining weld lands that vary in thickness along the length of the weld. An adjustable pin tool mechanism can be used to accomplish this in a single-pass, full-penetration weld by providing for precise changes in the pin length relative to the shoulder face during the weld process. The difficulty with this approach is in accurately adjusting the pin length to provide a consistent penetration ligament throughout the weld. The weld technique, control system, and instrumentation must account for mechanical and thermal compliances of the tooling system to conduct tapered welds successfully. In this study, a combination of static and in-situ measurements, as well as active control, is used to locate the pin accurately and maintain the desired penetration ligament. Frictional forces at the pin/shoulder interface were a source of error that affected accurate pin position. A traditional FSW pin tool design that requires a lead angle was used to join butt weld configurations that included both constant thickness and tapered sections. The pitch axis of the tooling was fixed throughout the weld; therefore, the effective lead angle in the tapered sections was restricted to within the tolerances allowed by the pin tool design. The sensitivity of the FSW process to factors such as thickness offset, joint gap, centerline offset, and taper transition offset were also studied. The joint gap and the thickness offset demonstrated the most adverse affects on the weld quality. Two separate tooling configurations were used to conduct tapered thickness welds successfully. The weld configurations included sections in which the thickness decreased along the weld, as well as sections in which the thickness increased along the weld. The data presented here include weld metallography, strength data, and process load data.

Adams, Glynn↗

The evolution of concepts of vestibular peripheral information processing: toward the dynamic, adaptive, parallel processing macular model

In a letter to Robert Hooke, written on 5 February, 1675, Isaac Newton wrote "If I have seen further than certain other men it is by standing upon the shoulders of giants." In his context, Newton was referring to the work of Galileo and Kepler, who preceded him. However, every field has its own giants, those men and women who went before us and, often with few tools at their disposal, uncovered the facts that enabled later researchers to advance knowledge in a particular area. This review traces the history of the evolution of views from early giants in the field of vestibular research to modern concepts of vestibular organ organization and function. Emphasis will be placed on the mammalian maculae as peripheral processors of linear accelerations acting on the head. This review shows that early, correct findings were sometimes unfortunately disregarded, impeding later investigations into the structure and function of the vestibular organs. The central themes are that the macular organs are highly complex, dynamic, adaptive, distributed parallel processors of information, and that historical references can help us to understand our own place in advancing knowledge about their complicated structure and functions.

Review, Tutorial↗

Individual thermal profiles as a basis for comfort improvement in space and other environments

BACKGROUND: The development of individualized countermeasures to address problems in thermoregulation is of considerable importance for humans in space and other extreme environments. A methodology is presented for evaluating minimal/maximal heat flux from the total human body and specific body zones, and for assessing individual differences in the efficiency of heat exchange from these body areas. The goal is to apply this information to the design of individualized protective equipment. METHODS: A multi-compartment conductive plastic tubing liquid cooling/warming garment (LCWG) was developed. Inlet water temperatures of 8-45 degrees C were imposed sequentially to specific body areas while the remainder of the garment was maintained at 33 degrees C. RESULTS: There were significant differences in heat exchange level among body zones in both the 8 degrees and 45 degrees C temperature conditions (p < 0.001). The greatest amount of heat was absorbed/released by the following areas: thighs (8 degrees C: -2.12 +/- 0.14 kcal min(-1); 45 degrees C: +1.58 +/- 0.23); torso (8 degrees C: -2.12 +/- 0.13 kcal min(-1); 45 degrees C: +1.31 +/- 0.27); calves (8 degrees C: -1.59 +/- 0.26 kcal min(-1); 45 degrees C: +1.53 +/- 0.24); and forearms (8 degrees C: -1.67 +/- 0.29 kcal x min(-1); 45 degrees C: +1.45 +/- 0.20). These are primarily zones with relatively large muscle mass and adipose tissue. Calculation of absorption/release heat rates standardized per unit tube length and flow rate instead of zonal surface area covered showed that there was significantly greater heat transfer in the head, hands, and feet (p < 0.001). The areas in which there was considerable between-subject variability in rates of heat transfer and thus most informative for individual profile design were the torso, thighs, shoulders, and calves or forearms. CONCLUSIONS: The methodology developed is sensitive to individual differences in the process of heat exchange and variations in different body areas, depending on their size and tissue mass content. The design of individual thermal profiles is feasible for better comfort of astronauts on long-duration missions and personnel in other extreme environments.

NASA Discipline Life Sciences Technologies↗

Work and fatigue characteristics of unsuited and suited humans during isolated isokinetic joint motions

The effects of a pressurized suit on human performance were investigated. The suit is known as an Extra-Vehicular Mobility Unit (EMU) and is worn by astronauts while working outside their spacecraft in a low earth orbit. Isolated isokinetic joint torques of three female and three male subjects (all experienced users of the suit in 1G gravity) were measured while working at 100% and 80% of their maximum voluntary torque (MVT, which is synonymous with maximum voluntary contraction (MVC)). It was found that the average decrease in the total amount of work (the sum of the work in each repetition until fatigue) done when the subjects were wearing the EMU were 48% and 41% while working at 100% and 80% MVT, respectively. There is a clear relationship between the MVT and the time and amount of work done until fatigue. Here, the time to fatigue is defined as the ending time of the repetition for which the computed work done during that repetition dropped below 50% of the work done during the first repetition. In general the stronger joints took longer to fatigue and did more work than the weaker joints. It was found that the EMU decreases the work output at the wrist and shoulder joints the most, due to the EMU joint geometry. The EMU also decreased the joint range of motion. The average total amount of work done by the test subjects increased by 5.2% (20.4%) for the unsuited (suited) case, when the test subjects decreased the level of effort from 100% to 80% MVT. Also, the average time to fatigue increased by 9.2% (25.6%) for the unsuited (suited) case, when the test subjects decreased the level of effort from 100% to 80% MVT. It was also found that the experimentally measured torque decay could be predicted by a logarithmic equation. The absolute average errors in the predictions were found to be 18.3% and 18.9% for the unsuited and suited subjects, respectively, when working at 100% MVT, and 22.5% and 18.8% for the unsuited and suited subjects, respectively, when working at 80% MVT. These results could be very useful in the design of future EMU suits and the planning of Extra-Vehicular Activity (EVA) for the future International Space Station assembly operations.

NASA Discipline Life Sciences Technologies↗

Lumbar spine disc height and curvature responses to an axial load generated by a compression device compatible with magnetic resonance imaging

STUDY DESIGN: Axial load-dependent changes in the lumbar spine of supine healthy volunteers were examined using a compression device compatible with magnetic resonance imaging. OBJECTIVE: To test two hypotheses: Axial loading of 50% body weight from shoulder to feet in supine posture 1) simulates the upright lumbar spine alignment and 2) decreases disc height significantly. SUMMARY OF BACKGROUND DATA: Axial compression on the lumbar spine has significantly narrowed the lumbar dural sac in patients with sciatica, neurogenic claudication or both. METHODS: Using a device compatible with magnetic resonance imaging, the lumbar spine of eight young volunteers, ages 22 to 36 years, was axially compressed with a force equivalent to 50% of body weight, approximating the normal load on the lumbar spine in upright posture. Sagittal lumbar magnetic resonance imaging was performed to measure intervertebral angle and disc height before and during compression. RESULTS: Each intervertebral angle before and during compression was as follows: T12-L1 (-0.8 degrees +/- 2.5 degrees and -1.5 degrees +/- 2.6 degrees ), L1-L2 (0.7 degrees +/- 1.4 degrees and 3.3 degrees +/- 2.9 degrees ), L2-L3 (4.7 degrees +/- 3.5 degrees and 7.3 degrees +/- 6 degrees ), L3-L4 (7.9 degrees +/- 2.4 degrees and 11.1 degrees +/- 4.6 degrees ), L4-L5 (14.3 degrees +/- 3.3 degrees and 14.9 degrees +/- 1.7 degrees ), L5-S1 (25.8 degrees +/- 5.2 degrees and 20.8 degrees +/- 6 degrees ), and L1-S1 (53.4 degrees +/- 11.9 degrees and 57.3 degrees +/- 16.7 degrees ). Negative values reflect kyphosis, and positive values reflect lordosis. A significant difference between values before and during compression was obtained at L3-L4 and L5-S1. There was a significant decrease in disc height only at L4-L5 during compression. CONCLUSIONS: The axial force of 50% body weight in supine posture simulates the upright lumbar spine morphologically. No change in intervertebral angle occurred at L4-L5. However, disc height at L4-L5 decreased significantly during compression.

Non-NASA Center↗

Interstellar PAH emission in the 11-14 micron region: new insights from laboratory data and a tracer of ionized PAHs

The Ames infrared spectral database of isolated, neutral and ionized polycyclic aromatic hydrocarbons (PAHS) shows that aromatic CH out-of-plane bending frequencies are significantly shifted upon ionization. For solo- and duet-CH groups, the shift is pronounced and consistently toward higher frequencies. The solo-CH modes are blueshifted by an average of 27 cm-1 and the duet-CH modes by an average of 17 cm-1. For trio- and quartet-CH groups, the ionization shifts of the out-of-plane modes are more erratic and typically more modest. As a result of these ionization shifts, the solo-CH out-of-plane modes move out of the region classically associated with these vibrations in neutral PAHS, falling instead at frequencies well above those normally attributed to out-of-plane bending, vibrations of any type. In addition, for the compact PAHs studied, the duet-CH out-of-plane modes are shifted into the frequency range traditionally associated with the solo-CH modes. These results refine our understanding of the origin of the dominant interstellar infrared emission feature near 11.2 microns, whose envelope has traditionally been attributed only to the out-of-plane bending of solo-CH groups on PAHS, and provide a natural explanation for the puzzling emission feature near 11.0 microns within the framework of the PAH model. Specifically, the prevalent but variable long-wavelength wing or shoulder that is often observed near 11.4 microns likely reflects the contributions of duet-CH units in PAH cations. Also, these results indicate that the emission between 926 and 904 cm-1 (10.8 and 11.1 microns) observed in many sources can be unambiguously attributed to the out-of-plane wagging, of solo-CH units in moderately sized (fewer than 50 carbon atom) PAH cations, making this emission an unequivocal tracer of ionized interstellar PAHS.

Astronomy↗

Simultaneous concentration and purification through gradient deformation chromatography

Mobile-phase additives, commonly used to modulate absorbate retention in gradient elution chromatography, are usually assumed to be either linearly retained or unretained. Previous theoretical work from our laboratory has shown that these modulators, such as salts in ion-exchange and hydrophobic interaction chromatography and organic modifiers in reversed-phase chromatography, can absorb nonlinearly, giving rise to gradient deformation. Consequently, adsorbate peaks that elute in the vicinity of the head of the deformed gradient may exhibit unusual shapes, form shoulders, and/or be concentrated. These effects for a reversed-phase sorbent with aqueous acetonitrile (ACN) as the modulator are verified experimentally. Gradient deformation is demonstrated experimentally and agrees with simulations based on ACN isotherm parameters that are independently determined from batch equilibrium studies using the layer model. Unusual absorbate peak shapes were found experimentally for single-component injections of phenylalanine, similar to those calculated by the simulations. A binary mixture of tryptophan and phenylalanine is used to demonstrate simultaneous concentration and separation, again in agreement with simulations. The possibility of gradient deformation in ion-exchange and hydrophobic interaction chromatography is discussed.

NASA Discipline Number 93-10↗

The infrared spectrum of the Galactic center and the composition of interstellar dust

We have obtained 5-8 micrometers spectra of the Galactic center from the Kuiper Airborne Observatory at resolving powers of approximately 50, approximately 150, and approximately 300. These spectra show absorption features at 5.5, 5.8, 6.1, and 6.8 micrometers. Together with previously observed features in the 3 micrometers region, these features are compared with laboratory spectra of candidate materials. The 3.0 and 6.1 micrometers features are due to the OH stretching and bending variations of H2O and are well fitted by water of hydration in silicates (e.g., talc). The 3.0 micrometer band is equally well fitted by ice mixtures containing 30% H2O, but such mixtures do not provide a good fit to the observed 6.1 micrometer band. The 3.4 and 6.8 micrometers features are identified with the CH stretching and deformation modes in CH2 and CH3 groups in saturated aliphatic hydrocarbons. The 6.1 micrometer band shows a short wavelength shoulder centered on 5.8 micrometer, attributed to carbonyl (C double bond O) groups in this interstellar hydrocarbon dust component. Finally, the narrow 5.5 micrometer feature is also attributed to carbonyl groups, but in the form of metal carbonyls [e.g., Fe(CO)4]. We have derived column densities and abundances along the line of sight toward the Galactic center for the various identified dust components. This analysis shows that hydrocarbon grains contain only 0.08 of the elemental abundance of C and contribute only a relatively minor fraction (0.1) of the total dust volume. Most of the interstellar dust volume is made up of silicates (approximately 0.6). Small graphite grains, responsible for the 2200 angstroms bump, account for 0.07 of the total dust volume. The remaining one-quarter of the interstellar dust volume consists of a material(s) without strong IR absorption features. Likely candidates include large graphite grains, diamonds, or amorphous carbon grains, which all have weak or no IR active modes. Finally, various models for the origin of the hydrocarbon dust component of the interstellar dust are discussed. All of them face some problems in explaining the observations, in particular, the absence of the spectroscopic signature of hydrocrbon grains in sources associated with molecular clouds.

NASA Discipline Exobiology↗

Prediction and Validation of Mars Pathfinder Hypersonic Aerodynamic Data Base

Postflight analysis of the Mars Pathfinder hypersonic, continuum aerodynamic data base is presented. Measured data include accelerations along the body axis and axis normal directions. Comparisons of preflight simulation and measurements show good agreement. The prediction of two static instabilities associated with movement of the sonic line from the shoulder to the nose and back was confirmed by measured normal accelerations. Reconstruction of atmospheric density during entry has an uncertainty directly proportional to the uncertainty in the predicted axial coefficient. The sensitivity of the moment coefficient to freestream density, kinetic models and center-of-gravity location are examined to provide additional consistency checks of the simulation with flight data. The atmospheric density as derived from axial coefficient and measured axial accelerations falls within the range required for sonic line shift and static stability transition as independently determined from normal accelerations.

Gnoffo, Peter A.↗

Aerothermodynamic Analysis of Commercial Experiment Transporter (COMET) Reentry Capsule

An aerothermodynamic analysis of the Commercial Experiment Transporter (COMET) reentry capsule has been performed using the laminar thin-layer Navier-Stokes solver Langley Aerothermodynamic Upwind Relaxation Algorithm. Flowfield solutions were obtained at Mach numbers 1.5, 2, 5, 10, 15, 20, 25, and 27.5. Axisymmetric and 5, 10, and 20 degree angles of attack were considered across the Mach-number range, with the Mach 25 conditions taken to 90 degrees angle of attack and the Mach 27.5 cases taken to 60 degrees angle of attack. Detailed surface heat-transfer rates were computed at Mach 20 and 25, revealing that heating rates on the heat-shield shoulder ,can exceed the stagnation-point heating by 230 percent. Finite-rate chemistry solutions were performed above Mach 10, otherwise perfect gas computations were made. Drag, lift, and pitching moment coefficients are computed and details of a wake flow are presented. The effect of including the wake in the solution domain was investigated and base pressure corrections to forebody drag coefficients were numerically determined for the lower Mach numbers. Pitching moment comparisons are made with direct simulation Monte Carlo results in the more rarefied flow at the highest Mach numbers, showing agreement within two-percent. Thin-layer Navier-Stokes computations of the axial force are found to be 15 percent higher across the speed range than the empirical/Newtonian based results used during the initial trajectory analyses.

Wood, William A.↗

A fluid--structure interaction finite element analysis of pulsatile blood flow through a compliant stenotic artery

A new model is used to analyze the fully coupled problem of pulsatile blood flow through a compliant, axisymmetric stenotic artery using the finite element method. The model uses large displacement and large strain theory for the solid, and the full Navier-Stokes equations for the fluid. The effect of increasing area reduction on fluid dynamic and structural stresses is presented. Results show that pressure drop, peak wall shear stress, and maximum principal stress in the lesion all increase dramatically as the area reduction in the stenosis is increased from 51 to 89 percent. Further reductions in stenosis cross-sectional area, however, produce relatively little additional change in these parameters due to a concomitant reduction in flow rate caused by the losses in the constriction. Inner wall hoop stretch amplitude just distal to the stenosis also increases with increasing stenosis severity, as downstream pressures are reduced to a physiological minimum. The contraction of the artery distal to the stenosis generates a significant compressive stress on the downstream shoulder of the lesion. Dynamic narrowing of the stenosis is also seen, further augmenting area constriction at times of peak flow. Pressure drop results are found to compare well to an experimentally based theoretical curve, despite the assumption of laminar flow.

Non-NASA Center↗

Effects of alpha-particles on survival and chromosomal aberrations in human mammary epithelial cells

We have studied the radiation responses of a human mammary epithelial cell line, H184B5 F5-1 M/10. This cell line was derived from primary mammary cells after treatment with chemicals and heavy ions. The F5-1 M/10 cells are immortal, density-inhibited in growth, and non-tumorigenic in athymic nude mice and represent an in vitro model of the human epithelium for radiation studies. Because epithelial cells are the target of alpha-particles emitted from radon daughters, we concentrated our studies on the efficiency of alpha-particles. Confluent cultures of M/10 cells were exposed to accelerated alpha-particles [beam energy incident at the cell monolayer = 3.85 MeV, incident linear energy transfer (LET) in cell = 109 keV/microns] and, for comparison, to 80 kVp x-rays. The following endpoints were studied: (1) survival, (2) chromosome aberrations at the first postirradiation mitosis, and (3) chromosome alterations at later passages following irradiation. The survival curve was exponential for alpha-particles (D0 = 0.73 +/- 0.04 Gy), while a shoulder was observed for x-rays (alpha/beta = 2.9 Gy; D0 = 2.5 Gy, extrapolation number 1.6). The relative biological effectiveness (RBE) of high-LET alpha-particles for human epithelial cell killing was 3.3 at 37% survival. Dose-response curves for the induction of chromosome aberrations were linear for alpha-particles and linearquadratic for x-rays. The RBE for the induction of chromosome aberrations varied with the type of aberration scored and was high (about 5) for chromosome breaks and low (about 2) for chromosome exchanges.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Center JSC↗

The head and neck discomfort of autonomic failure: an unrecognized aetiology of headache

Information concerning the frequency, severity, character, location, duration, diurnal pattern of headache and ancillary symptoms were obtained in 25 patients with autonomic failure and 44 control subjects. Precipitating and ameliorating factors were identified. Autonomic failure patients had more head and neck discomfort than controls. Their discomfort was much more likely to localize in the occiput, nape of the neck and shoulder, compared with controls. There was a greater tendency for the discomfort to occur in the morning and after meals. It was sometimes less than 5 min in duration and was often associated with dimming, blurring, or tunnelling of vision. It was provoked by upright posture and relieved by lying down. Patients with severe autonomic failure and orthostatic hypotension often present with a posture-dependent headache or neck pain. Because the relationship of these symptoms to posture is often not recognized, the fact that these findings may signal an underlying autonomic disorder is underappreciated, and the opportunity to consider this aetiology for the headache may be missed.

NASA Discipline Regulatory Physiology↗

Gravitoinertial force level influences arm movement control

1. The ability to move the forearm between remembered elbow joint angles immediately after rapid increases or decreases of the background gravitoinertial force (G) level was measured. The movements had been well-practiced in a normal 1G environment before the measurements in high-(1.8G) and low-force (0G) environments. The forearm and upper arm were always unsupported to maximize the influence of altered G-loading and to minimize extraneous cues about arm position. 2. Horizontal and vertical movement planes were studied to measure the effects of varying the G load in the movement plane within a given G background. Rapid and slow movements were studied to assess the role of proprioceptive feedback. 3. G level did not affect the amplitude of rapid movements, indicating that subjects were able to plan and to generate appropriate motor commands for the new G loading of the arm. The amplitude of slow movements was affected by G level, indicating that proprioceptive feedback is influenced by G level. 4. The effects of G level were similar for horizontal and vertical movements, indicating that proprioceptive information from supporting structures, such as the shoulder joint and muscles, had a role in allowing generation of the appropriate motor commands. 5. The incidence and size of dynamic overshoots were greater in 0G and for rapid movements. This G-related change in damping suggests a decrease in muscle spindle activity in 0G. A decrease in muscle spindle activity in 0G and an increase in 1.8G are consistent with the results of our prior studies on the tonic vibration reflex, locomotion, and perception of head movement trajectory in varying force backgrounds.

NASA Program Space Physiology and Countermeasures↗

A Look from the Inside

NASA's Hubble Space Telescope has given the world amazing images of the distant stars, planets, and galaxies. The cutting-edge imaging technology that enhances the Hubble images also extends its benefits to life here on Earth, from deciphering previously unreadable portions of the Dead Sea Scrolls to improving digital mammographies for advanced cancer detection. This imaging technology is now helping physicians to perform micro-invasive arthroscopic surgery, which is the visual examination of an interior joint such as the knee. In 1997, NASA's Glenn Research Center signed a Space Act Agreement with Micro Medical Devices, Inc. (MMD), a medical device engineering company that licenses miniature surgical devices. At that time, MMD was in the process of developing a new micro-endoscope. This tool enables surgeons to view what is happening inside the body on a screen, eliminating the need for a more invasive diagnostic procedure. The images from the micro-endoscope needed to be extremely clear, a challenge with the tool s small size. The images also needed to be viewed in real time to allow surgeons to see what was happening in the body at that very moment. MMD established Clear Image Technology, LLC, of Elyria, Ohio, to commercialize the miniature endoscope. Clear Image Technology then partnered with Arthrotek, Inc., a sports medicine subsidiary of Biomet, Inc., to introduce the tool to the commercial market as the InnerVue[TM] Diagnostic Scope System. The InnerVue system is designed for use in a diagnostic environment, such as an office or outpatient service, to evaluate conditions within a joint. While the InnerVue scope is primarily being applied to the knee and shoulder, other small joints such as the wrist, elbow, and ankle are being investigated. A physician can use the system alone or in conjunction with magnetic resonance imaging (MRI) to determine the next treatment step for each patient. The procedure can be more accurate than MRI, particularly with diagnosing cartilage and articular surface damage and assessing arthritis severity.

Source record↗

Gearing Up for the Big Game...and More

Bill Elkins, a member of the U.S. Space Foundation's Space Technology Hall of Fame, is using his experience in developing cooling garments for use in sports and medicine. His company, CoolSystems, has developed the Game Ready[TM] Accelerated Recovery System. Game Ready[TM] ergonomic wraps are designed to custom fit the ankle, knee, back, torso, shoulder, elbow, and wrist and provide deep tissue cooling therapy with intermittent compression to reduce pain, swelling, and tissue damage. Recharge[TM] cooling garments have been developed to lower core body temperature in people with heat-sensitive multiple sclerosis, reducing symptoms such as fatigue, decreased balance, impaired vision, and decreased endurance. The company currently is collaborating with Stanford University Medical Center's Stanford Stroke Center to investigate the effectiveness of discrete hypothermia in stroke and head trauma patients.

Source record↗

Back to the Future: A Historical Perspective of Lunar and Martian In-situ Fabrication and Repair

Scientists, engineers, and the general public have always speculated and dreamed about living and working on other planets. The allure and challenges of this endeavor have generated innumerable Conferences, feasibility studies and six manned Moon landings. As NASA prepares to return to the Moon and eventually Mars, it is only natural to stand on the shoulders of those giants who have gone before us. This time, as we go to stay, the development of processes that maximize the use of in-situ resources will become even more important. On demand fabrication of piece-parts to reduce required spares, development of habitat structures, and the ability to make repairs will all benefit from the use of in-situ materials including raw regolith and metals and/or gases extracted from regolith or planetary atmospheres. To support these activities, there will also be a need for recycling as well as non-destructive evaluation technologies. This paper will present a historical overview of technology development associated with In-Situ Fabrication and Repair (ISFR) elements described above and discuss the ISFR program implemented at NASA/Marshall Space Flight Center.

Bassler, Julie A.↗

Trajectory Reconstruction for the Genesis Entry

An overview of the reconstruction analyses performed for the Genesis capsule entry is described. The results indicate that the actual entry prior to the drogue deployment failure was very close to the pre-entry predictions. The capsule landed 8.3 km south of the desired target at Utah Test and Training Range. Analysis on infrared video footage (obtained from the tracking stations) during the descent estimated the onset of the capsule tumble at Mach 0.9. Frequency analysis on the infrared video data indicates that the aerodynamics generated for the Genesis capsule reasonably predicted the drag and static stability. Observations of the heatshield support the pre-entry simulation estimates of a small hypersonic angles-of-attack, since there is very little, if any, charring of the shoulder region or the afterbody. Through this investigation, an overall assertion can be made that all the data gathered from the Genesis entry is consistent with flight performance close to the nominal pre-entry prediction. Consequently, the design principles and methodologies utilized for the flight dynamics, aerodynamics, and aerothermodynamics analyses have been corroborated.

Desai, Prasun N.↗