Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Sparsity-based acoustic inversion in cross-sectional multiscale optoacoustic imaging

Purpose: With recent advancement in hardware of optoacoustic imaging systems, highly detailed cross-sectional images may be acquired at a single laser shot, thus eliminating motion artifacts. Nonetheless, other sources of artifacts remain due to signal distortion or out-of-plane signals. The purpose of image reconstruction algorithms is to obtain the most accurate images from noisy, distorted projection data. Methods: In this paper, the authors use the model-based approach for acoustic inversion, combined with a sparsity-based inversion procedure. Specifically, a cost function is used that includes the L1 norm of the image in sparse representation and a total variation (TV) term. The optimization problem is solved by a numerically efficient implementation of a nonlinear gradient descent algorithm. TV–L1 model-based inversion is tested in the cross section geometry for numerically generated data as well as for in vivo experimental data from an adult mouse. Results: In all cases, model-based TV–L1 inversion showed a better performance over the conventional Tikhonov regularization, TV inversion, and L1 inversion. In the numerical examples, the images reconstructed with TV–L1 inversion were quantitatively more similar to the originating images. In the experimental examples, TV–L1 inversion yielded sharper images and weaker streak artifact. Conclusions: The results herein show that TV–L1 inversion is capable of improving the quality of highly detailed, multiscale optoacoustic images obtained in vivo using cross-sectional imaging systems. As a result of its high fidelity, model-based TV–L1 inversion may be considered as the new standard for image reconstruction in cross-sectional imaging.

60 APPLIED LIFE SCIENCES↗

Semi-Supervised Eigenbasis Novelty Detection

Recent discoveries in high-time-resolution radio astronomy data have focused attention on a new class of events. Fast transients are rare pulses of radio frequency energy lasting from microseconds to seconds that might be produced by a variety of exotic astrophysical phenomena. For example, X-ray bursts, neutron stars, and active galactic nuclei are all possible sources of short-duration, transient radio signals. It is difficult to anticipate where such signals might appear, and they are most commonly discovered through analysis of high-time- resolution data that had been collected for other purposes. Transients are often faint and difficult to detect, so improved detection algorithms can directly benefit the science yield of all such commensal monitoring. A new detection algorithm learns a low-dimensional linear manifold for describing the normal data. High reconstruction error indicates a novel signal that does not match the patterns of normal data. One unsupervised portion of the manifold model adapts its representation in response to recent data. A second supervised portion of the model is made of a basis trained in advance using labeled examples of RFI; this prevents false positives due to these events. For a linear model, an orthonormalization operation is used to combine these bases prior to the anomaly detection decision. Another novel aspect of the approach lies in combining basis vectors learned in an unsupervised, online fashion from the data stream with supervised basis vectors learned in advance from known examples of false alarms. Adaptive, data-driven detection is achieved that is also informed by existing domain knowledge about signals that may be statistically anomalous, but are not interesting and should therefore be ignored. The method was evaluated using data from the Parkes Multibeam Survey. This data set was originally collected to search for pulsars, which are astronomical sources that emit radio pulses at regular periods. However, several non-pulsar anomalies have recently been discovered in this dataset, making it a compelling test case. By explicitly filtering known false alarm patterns, the approach yields significantly better performance than current transient detection methods.

Wagstaff, Kiri L.↗

The Mu2e experiment — Searching for charged lepton flavor violation

The Mu2e experiment will search for a Standard Model violating rate of neutrinoless conversion of a muon into an electron in the presence of an aluminum nucleus. Observation of this charged lepton flavor violating process would be an unambiguous sign of new physics. Mu2e will improve upon previous searches for this process by four orders of magnitude. This requires the world’s highest-intensity muon beam, a detector system capable of efficiently reconstructing the 105 MeV/c conversion electron signal, and minimizing sensitivity to background events. A pulsed 8 GeV proton beam strikes a target, producing pions that decay into muons. Beam outside the pulse must be suppressed to < 1 0 – 10 to reduce beam-related backgrounds. The muon beam is guided from the production target along the transport system and onto the aluminum stopping target. Conversion electrons leave the stopping target and propagate inside a solenoidal magnetic field to the tracker and electromagnetic calorimeter. The tracker is a system of straw tube panels filled with Ar/CO 2 at 1 atm that tracks particles inside of a solenoidal B-field and measures their momenta with ~ 100 keV/c resolution to resolve signal events from decay-in-orbit backgrounds. The CsI calorimeter provides E / p and is used to seed the track reconstruction algorithm with σ E / E ~ 10 % and σ t < 500 ps . Additionally, a novel cosmic ray veto with greater than 99.99% efficiency brings the expected number of background events to fewer than one over three years of running. Finally, to normalize the experiment, the stopping target monitor measures the rate of capture photons from muons incident on the stopping target by using a system of high-purity germanium and lanthanum bromide scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-EF-BRA-06: A Novel Retrospective 3D K-Space Sorting 4D-MRI Technique Using a Radial K-Space Acquisition MRI Sequence

Purpose: Current retrospective 4D-MRI provides superior tumor-to-tissue contrast and accurate respiratory motion information for radiotherapy motion management. The developed 4D-MRI techniques based on 2D-MRI image sorting require a high frame-rate of the MR sequences. However, several MRI sequences provide excellent image quality but have low frame-rate. This study aims at developing a novel retrospective 3D k-space sorting 4D-MRI technique using radial k-space acquisition MRI sequences to improve 4D-MRI image quality and temporal-resolution for imaging irregular organ/tumor respiratory motion. Methods: The method is based on a RF-spoiled, steady-state, gradient-recalled sequence with minimal echo time. A 3D radial k-space data acquisition trajectory was used for sampling the datasets. Each radial spoke readout data line starts from the 3D center of Field-of-View. Respiratory signal can be extracted from the k-space center data point of each spoke. The spoke data was sorted based on its self-synchronized respiratory signal using phase sorting. Subsequently, 3D reconstruction was conducted to generate the time-resolved 4D-MRI images. As a feasibility study, this technique was implemented on a digital human phantom XCAT. The respiratory motion was controlled by an irregular motion profile. To validate using k-space center data as a respiratory surrogate, we compared it with the XCAT input controlling breathing profile. Tumor motion trajectories measured on reconstructed 4D-MRI were compared to the average input trajectory. The mean absolute amplitude difference (D) was calculated. Results: The signal extracted from k-space center data matches well with the input controlling respiratory profile of XCAT. The relative amplitude error was 8.6% and the relative phase error was 3.5%. XCAT 4D-MRI demonstrated a clear motion pattern with little serrated artifacts. D of tumor trajectories was 0.21mm, 0.23mm and 0.23mm in SI, AP and ML directions, respectively. Conclusion: A novel retrospective 3D k-space sorting 4D-MRI technique has been developed and evaluated on human digital phantom. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

Model-independent Exoplanet Transit Spectroscopy

We propose a new data analysis method for obtaining transmission spectra of exoplanet atmospheres and brightness variation across the stellar disk from transit observations. The new method is capable of recovering exoplanet atmosphere absorption spectra and stellar specific intensities without relying on theoretical models of stars and planets. We simultaneously fit both stellar specific intensity and planetary radius directly to transit light curves. This allows stellar models to be removed from the data analysis. Furthermore, we use a data quality weighted filtering technique to achieve an optimal trade-off between spectral resolution and reconstruction fidelity homogenizing the signal-to-noise ratio across the wavelength range. Such an approach is more efficient than conventional data binning onto a low-resolution wavelength grid. We demonstrate that our analysis is capable of reproducing results achieved by using an explicit quadratic limb-darkening equation and that the filtering technique helps eliminate spurious spectral features in regions with strong telluric absorption. The method is applied to the VLT FORS2 observations of the exoplanets GJ 1214 b and WASP-49 b, and our results are in agreement with previous studies. Comparisons between obtained stellar specific intensity and numerical models indicates that the method is capable of accurately reconstructing the specific intensity. The proposed method enables more robust characterization of exoplanetary atmospheres by separating derivation of planetary transmission and stellar specific intensity spectra (that is model-independent) from chemical and physical interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

A multiresolution wavelet representation in two or more dimensions

In the multiresolution approximation, a signal is examined on a hierarchy of resolution scales by projection onto sets of smoothing functions. Wavelets are used to carry the detail information connecting adjacent sets in the resolution hierarchy. An algorithm has been implemented to perform a multiresolution decomposition in n greater than or equal to 2 dimensions based on wavelets generated from products of 1-D wavelets and smoothing functions. The functions are chosen so that an n-D wavelet may be associated with a single resolution scale and orientation. The algorithm enables complete reconstruction of a high resolution signal from decomposition coefficients. The signal may be oversampled to accommodate non-orthogonal wavelet systems, or to provide approximate translational invariance in the decomposition arrays.

Bromley, B. C.↗

Rainfall Field Reconstruction by Opportunistic Use of the Rain- Induced Attenuation on Microwave Satellite Signals: The July 2021 Extreme Rain Event in Germany as a Case Study

This paper presents a practical application of an opportunistic technique for the estimation of rainfall intensity and accumulated precipitation. The proposed technique is based upon signal strength measurements made by commercial-grade interactive satellite terminals. By applying some processing, the rain-induced attenuation on the microwave downlink from the satellite is first evaluated; then the rain attenuation is eventually mapped into a rainfall rate estimate via a tropospheric model. This methodology has been applied to a test area of 30 × 30 km 2 around the city of Dortmund (North Rhine-Westphalia, upper basin of Ermscher river), for the heavy rain event that devastated western Germany in July, 2021. A rainfall map on this area is obtained from the measurements collected by a set of satellite terminals deployed in the region, and successfully compared with a map obtained with a conventional weather radar.

Rainfall rate estimation↗

Lensing reconstruction from a patchwork of polarization maps

The lensing signals involved in CMB polarization maps have already been measured with ground-based experiments such as SPTpol and POLARBEAR, and would become important as a probe of cosmological and astrophysical issues in the near future. Sizes of polarization maps from ground-based experiments are, however, limited by contamination of long wavelength modes of observational noise. To further extract the lensing signals, we explore feasibility of measuring lensing signals from a collection of small sky maps each of which is observed separately by a ground-based large telescope, i.e., lensing reconstruction from a patchwork map of large sky coverage organized from small sky patches. We show that, although the B-mode power spectrum obtained from the patchwork map is biased due to baseline uncertainty, bias on the lensing potential would be negligible if the B-mode on scales larger than the blowup scale of 1/f noise is removed in the lensing reconstruction. As examples of cosmological applications, we also show 1) the cross-correlations between the reconstructed lensing potential and full-sky temperature/polarization maps from satellite missions such as PLANCK and LiteBIRD, and 2) the use of the reconstructed potential for delensing B-mode polarization of LiteBIRD observation.

79 ASTRONOMY AND ASTROPHYSICS↗

SELF CALIBRATED STMR ARRAY FOR MATERIAL CHARACTERIZATION AND SHM OF ORTHOTROPIC PLATE-LIKE STRUCTURES

A full ring STMR array patch had been used for Structural Health Monitoring (SHM) of anisotropic materials where the elastic moduli, correspond to the virgin sample, were used in the calculations. In the present work an in-situ SHM has been successfully demonstrated using a novel compact sensor patch (Double ring single quadrant small footprint STMR array) through simultaneous reconstruction of the elastic moduli, material symmetry, orientation of principal planes and defect imaging. The direct received signals were used to measure Lamb wave velocities, which were used in a slowness based reconstructed algorithm using Genetic Algorithm to reconstruct the elastic moduli, material symmetry and orientation of principal planes. The measured signals along with the reconstructed elastic moduli were used in the phased addition algorithm for imaging the damages present on the structure. To show the applicability of the method, simulations were carried out with the double ring single quadrant STMR array configuration to image defects and are compared with the images obtained using simulation data of the full ring STMR array configuration. The experimental validation has been carried out using 3.15 mm quasi-isotropic graphite-epoxy composite. The double ring single quadrant STMR array has advantages over the full ring STMR array as it can carry out in-situ SHM with limited footprint on the structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark Matter Reconstruction in LBAI Experiments with Imperfect Data

Long-baseline atom interferometer (LBAI) experiments offer unprecedented sensitivity to ultralight scalar dark matter (DM) [1], however reconstruction of a putative DM signal with traditional frequency-domain analysis requires ``perfect data (i.e., regularly-sampled with no missing samples). In a real LBAI experiment, there will undoubtedly be imperfections in the data leading to downtime. This downtime can arise from operational considerations (e.g., maintenance), the operational environment (motion of people and animals [2] or elevators), and robustness of the experimental apparatus (e.g., bad atom launches). In this work, we investigate the impact of various downtime models on the overall DM sensitivity of such an experiment. We compare the sensitivity for each downtime model as determined by a ``compound FFT analysis to a baseline no-downtime case. We also show how much sensitivity can be regained by moving to a Lomb-Scargle frequency analysis, as in [2]. Furthermore, we demonstrate reconstruction of the DM wave s phase as well as its frequency. [1] D. Antypas, et al, ``New Horizons: Scalar and Vector Ultralight Dark Matter (2022). arXiv:2203.14915 [2] J. Carlton and C. McCabe, ``From RATs to riches: mitigating anthropogenic and synanthropic noise in atom interferometer searches for ultra-light dark matter (2023). arXiv:2308.101731

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase Screen Determination for the GeoSAR Interferometric Mapping Instrument

GeoSAR is a dual frequency airborne radar interferometric mapping instrument designed to obtain high resolution and high accuracy digital elevation models. The X-band inteferometric antennas are mounted beneath the fuselage with a separation distance of 2.6 m. Midway between the antennas along the aircraft centerline is a large fairing housing the Laser Baseline metrology System (LBMS) and Inertial Navigtion Units (INUs). The P-band antennas are mounted in wingtip pods approximately 10 m from the aircraft centerline. Multipath signals reflected from the LBMS fairing cause phase distortions corrupting the topograhic height measurements for both the X-band and P-band systems. In addition multipath off the wing affects the P-band phase measurements. In this paper we discuss a technique used to mitigate the amount of X-Band multipath and methods calibrating and correcting the phase for both X-Band and P-Band using a high accuracy DEM. Height differences between the interferometrically derived elevations and a photogrammetrically derived DEM are converted into phase differences. Multipath phase errors are sinusoidal with spatial frequency and amplitude related to the magnitude of reflection of the multipath reflection point and its distance from the interferometric antennas. These phase residuals are fitted using a Chebyshev polynomial sequence and used as a phase screen in the processor to correct the phase prior to height reconstruction. Based on the correction signal it is possible to estimate the location and magnitude of the multipath signal. This information can then be used to extend the domain of the phase screen over mapping angles not covered during the calibration passes. Keywords: SAR,interferometry,phase screen

Hensley, Scott↗

High energy neutron transmission analysis of dry cask storage

Since the U.S. currently only approves of storing used nuclear fuel in pools or dry casks, the demand for dry cask storage is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. With the rising demand comes additional pressure to ensure the integrity of dry cask systems. Visual inspection is costly and man-power intensive, so alternative nondestructive testing techniques are desired to insure the continued safe and effective storage of fuel. One such approach being investigated by the University of Florida is neutron based computed tomography. Simulations in MCNP are preformed where D-T energy neutrons are transmitted through the dry cask and measured on the opposite side. If the transmitted signal is clear enough, the interior of the cask can be reconstructed from the measurement of the alterations of neutron signal intensity using standard mathematical techniques developed for medical imaging. Preliminary efforts show a correlation between energy and number of scatters (which is an indication of retention of position information). Work is ongoing to quantify if the correlation is strong enough that an energy discriminator may be used as a filter in future image reconstruction. The calculated transmission probability suggests that an image could be reconstructed with a week of scanning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cutoff probe using Fourier analysis for electron density measurement

This paper proposes a new method for cutoff probe using a nanosecond impulse generator and an oscilloscope, instead of a network analyzer. The nanosecond impulse generator supplies a radiating signal of broadband frequency spectrum simultaneously without frequency sweeping, while frequency sweeping method is used by a network analyzer in a previous method. The transmission spectrum (S21) was obtained through a Fourier analysis of the transmitted impulse signal detected by the oscilloscope and was used to measure the electron density. The results showed that the transmission frequency spectrum and the electron density obtained with a new method are very close to those obtained with a previous method using a network analyzer. And also, only 15 ns long signal was necessary for spectrum reconstruction. These results were also compared to the Langmuir probe's measurements with satisfactory results. This method is expected to provide not only fast measurement of absolute electron density, but also function in other diagnostic situations where a network analyzer would be used (a hairpin probe and an impedance probe) by replacing the network analyzer with a nanosecond impulse generator and an oscilloscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-197: A Novel Intra-Beam Range Detection and Adaptation Strategy for Particle Therapy

Purpose: In-vivo range detection/verification is crucial in particle therapy for effective and safe delivery. The state-of-art techniques are not sufficient for in-vivo on-line range verification due to conflicts among patient dose, signal statistics and imaging time. We propose a novel intra-beam range detection and adaptation strategy for particle therapy. Methods: This strategy uses the planned mid-range spots as probing beams without adding extra radiation to patients. Such choice of probing beams ensures the Bragg peaks to remain inside the tumor even with significant range variation from the plan. It offers sufficient signal statistics for in-beam positron emission tomography (PET) due to high positron activity of therapeutic dose. The probing beam signal can be acquired and reconstructed using in-beam PET that allows for delineation of the Bragg peaks and detection of range shift with ease of detection enabled by single-layered spots. If the detected range shift is within a pre-defined tolerance, the remaining spots will be delivered as the original plan. Otherwise, a fast re-optimization using range-shifted beamlets and accounting for the probing beam dose is applied to consider the tradeoffs posed by the online anatomy. Simulated planning and delivery studies were used to demonstrate the effectiveness of the proposed techniques. Results: Simulations with online range variations due to shifts of various foreign objects into the beam path showed successful delineation of the Bragg peaks as a result of delivering probing beams. Without on-line delivery adaptation, dose distribution was significantly distorted. In contrast, delivery adaptation incorporating detected range shift recovered well the planned dose. Conclusion: The proposed intra-beam range detection and adaptation utilizing the planned mid-range spots as probing beams, which illuminate the beam range with strong and accurate PET signals, is a safe, practical, yet effective approach to address range uncertainty issues in particle therapy.

60 APPLIED LIFE SCIENCES↗

The clustering of galaxies in the completed SDSS-III Baryon Oscillation Spectroscopic Survey: Baryon Acoustic Oscillations in Fourier-space

Here, we analyse the Baryon Acoustic Oscillation (BAO) signal of the final Baryon Oscillation Spectroscopic Survey (BOSS) data release (DR12). Our analysis is performed in Fourier-space, using the power spectrum monopole and quadrupole. The dataset includes 1 198 006 galaxies over the redshift range 0.2 < z < 0.75. We divide this dataset into three (overlapping) redshift bins with the effective redshifts z eff = 0.38, 0.51 and 0.61. We demonstrate the reliability of our analysis pipeline using N-body simulations as well as 1000 MultiDark-Patchy mock catalogues, which mimic the BOSS-DR12 target selection. We apply density eld reconstruction to enhance the BAO signal-to-noise ratio. By including the power spectrum quadrupole we can sep-arate the line-of-sight and angular modes, which allows us to constrain the angular diameter distance D A (z) and the Hubble parameter H ( z ) separately. We obtain two independent 1 : 6% and 1 : 5% constraints on D A (z) and 2.9% and 2.3% constraints on H(z) for the low (z eff = 0.38) and high (z eff = 0.61) redshift bin, respectively. We obtain two independent 1% and 0.9% constraints on the angular averaged distance D V (z), when ignoring the Alcock-Paczynski e ect. The detection significance of the BAO signal is of the order of 8σ (post-reconstruction) for each of the three redshift bins. Our results are in good agreement with the Planck prediction within CDM. This paper is part of a set that analyses the final galaxy clustering dataset from BOSS. The measurements and likelihoods presented here are combined with others in Alam et al. (2016) to produce the final cosmological constraints from BOSS.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of Unboosted Higgs Pair Production with HH to bbWW Decay with the CMS experiment at the LHC

Measurement of the Higgs boson self-interaction through the production of Higgs boson (H) pairs is critical for understanding the shape of the Higgs potential and the stability of the universe. Higgs pair production (HH) where one H decays to b quarks (H to bb) and the other to hadronically decaying W bosons (H to WW*→qqqq) has a large branching fraction with the cost of high background from jets produced through quantum chromodynamics (QCD). While previous all-hadronic HH→bbWW analyses focused on the few percent of highly energetic HH events with collimated decay products, this first study of its kind targets the more challenging 95$\%$ of HH to bbWW* in which decay products can be reconstructed as separate jets providing sensitivity to a complementary region of phase space. This poster focuses on generator level measurements of the fractions of HH to bbWW* signal events are fully or partially reconstructed and what fraction are impacted by contamination from high momentum jets from initial or final state radiation. Partially reconstructed events are further classified according to whether the H to bb, H to WW*, or W to qq are fully reconstructed

Gillespie, Emma [U. Louisville]↗

V3FIT: a code for three-dimensional equilibrium reconstruction

The V3FIT code for performing equilibrium reconstruction in three-dimensional plasmas is described. It is a modular code that has the potential to be coupled with a variety of equilibrium solvers to compute the externally measured response to an arbitrary internal state of the plasma. Singular value decomposition is used to identify the dominant components of the plasma state that can be accurately determined by the reconstruction process and to guide the minimization of the ! " 2 variance-normalized mismatch between the measured and computed signals. Comparison of a tokamak plasma equilibrium computed by V3FIT and by the axisymmetric equilibrium reconstruction code EFIT is presented. V3FIT is used to reconstruct an axisymmetric DIII-D equilibrium using experimentally observed magnetic diagnostic signals. Three-dimensional reconstructions of stellarator plasma equilibria in the CTH device show the code behaves as expected in the presence of experimental noise, appropriately ignores near-singular directions in parameter space, and robustly reconstructs equilibria starting from substantially different initial parameter values.

CIRCULAR CROSS-SECTION↗

Ionization electron signal processing in single phase LArTPCs. Part II. Data/simulation comparison and performance in MicroBooNE

The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗