Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photon sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Improved Spatial Resolution Achieved by Chromatic Intensity Interferometry

Interferometers are widely used in imaging technologies to achieve enhanced spatial resolution, but require that the incoming photons be indistinguishable. In previous work, we built and analyzed color erasure detectors which expand the scope of intensity interferometry to accommodate sources of different colors. Here we demonstrate experimentally how color erasure detectors can achieve improved spatial resolution in an imaging task, well beyond the diffraction limit. Utilizing two 10.9 mm-aperture telescopes and a 0.8 m baseline, we measure the distance between a 1063.6 nm source and a 1064.4 nm source separated by 4.2 mm at a distance of 1.43 km, which surpasses the diffraction limit of a single telescope by about 40 times. Moreover, chromatic intensity interferometry allows us to recover the phase of the Fourier transform of the imaged objects – a quantity that is, in the presence of modest noise, inaccessible to conventional intensity interferometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low voltage AC electroluminescence in silicon MOS capacitors

Low power silicon based light source and detector are attractive for on-chip photonic circuits given their ease of process integration. However, conventional silicon light emitting diodes emit photons with energies near the band edge where the corresponding silicon photodetectors lack responsivity. On the other hand, previously reported hot carrier electroluminescent silicon devices utilizing a reverse biased diode require high operating voltages. Here, we investigate hot carrier electroluminescence in silicon metal–oxide–semiconductor capacitors operating under transient voltage conditions. Further, during each voltage transient, large energy band bending is created at the edge of the source contact, much larger than what is achievable at a steady state. As a result, electrons and holes are injected efficiently from a single source contact into the silicon channel at the corresponding voltage transient, where they subsequently undergo impact ionization and phonon-assisted interband recombination. Notably, we show low voltage operation down to 2.8 V by using a 20 nm thick high-κ gate dielectric. We show further voltage scaling is possible by reducing the gate dielectric thickness, thus presenting a low voltage platform for silicon optoelectronic integrated circuits.

42 ENGINEERING↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

Considerations about future hard x-ray area detectors

X-ray sources continue to advance in both intensity and temporal domains, thereby opening new ways to analyze the structure and properties of matter, provided that the resultant x-ray images can be efficiently and quantitatively recorded. In this perspective we focus on specific limitations of pixel area x-ray detectors. Although pixel area x-ray detectors have also advanced in recent years, many experiments are still detector limited. Specifically, there is need for detectors that can acquire successive images at GHz rates; detectors that can accurately measure both single photon and millions of photons per pixel in the same image at frame rates of hundreds of kHz; and detectors that efficiently capture images of very hard x-rays (20 keV to several hundred keV). The data volumes and data rates of state-of-the-art detection exceeds most practical data storage options and readout bandwidths, thereby necessitating on-line processing of data prior to, or in lieu of full frame readouts.

36 MATERIALS SCIENCE↗

Resonant enhanced multiphoton ionization studies of atomic oxygen

In resonant enhanced multiphoton ionization (REMPI), an atom absorbs several photons making a transition to a resonant intermediate state and subsequently ionizing out of it. With currently available tunable narrow-band lasers, the extreme sensitivity of REMPI to the specific arrangement of levels can be used to selectively probe minute amounts of a single species (atom) in a host of background material. Determination of the number density of atoms from the observed REMPI signal requires a knowledge of the multiphoton ionization cross sections. The REMPI of atomic oxygen was investigated through various excitation schemes that are feasible with available light sources. Using quantum defect theory (QDT) to estimate the various atomic parameters, the REMPI dynamics in atomic oxygen were studied incorporating the effects of saturation and a.c. Stark shifts. Results are presented for REMPI probabilities for excitation through various 2p(3) (4S sup o) np(3)P and 2p(3) (4S sup o) nf(3)F levels.

Dixit, S. N.↗

Two-dimensional-lattice-confined single-molecule-like aggregates

Intermolecular distance largely determines the optoelectronic properties of organic matter. Conventional organic luminescent molecules are commonly used either as aggregates or as single molecules that are diluted in a foreigner matrix. They have garnered great research interest in recent decades for a variety of applications, including light-emitting diodes, lasers and quantum technologies, among others. However, there is still a knowledge gap on how these molecules behave between the aggregation and dilution states. Here we report an unprecedented phase of molecular aggregate that forms in a two-dimensional hybrid perovskite superlattice with a near-equilibrium distance, which we refer to as a single-molecule-like aggregate (SMA). By implementing two-dimensional superlattices, the organic emitters are held in proximity, but, surprisingly, remain electronically isolated, thereby resulting in a near-unity photoluminescence quantum yield, akin to that of single molecules. Moreover, the emitters within the perovskite superlattices demonstrate strong alignment and dense packing resembling aggregates, allowing for the observation of robust directional emission, substantially enhanced radiative recombination and efficient lasing. Molecular dynamics simulations together with single-crystal structure analysis emphasize the critical role of the internal rotational and vibrational degrees of freedom of the molecules in the two-dimensional lattice for creating the exclusive SMA phase. Furthermore, this two-dimensional superlattice unifies the paradoxical properties of single molecules and aggregates, thus offering exciting possibilities for advanced spectroscopic and photonic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Speckle correlation as a monitor of X-ray free-electron laser induced crystal lattice deformation

X-ray free-electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpretation of experimental results. This is also important for designing reliable high performance X-ray optical components. In this work, X-FEL beam-induced lattice alterations are investigated by measuring the shot-to-shot evolution of near-Bragg coherent scattering from a single crystalline germanium sample. It is shown that X-ray photon correlation analysis of sequential speckle patterns measurements can be used to monitor the nature and extent of lattice rearrangements. Additionally, abrupt, irreversible changes are observed following intermittent high-fluence monochromatic X-ray pulses, thus revealing the existence of a threshold response to X-FEL pulse intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Star Confusion Effect on SIM PlanetQuest Astrometric Performance

SIM PlanetQuest will measure star positions to an accuracy of a few microarcseconds using precise white light fringe measurements. One challenge for SIM observation scenario is "star confusion," where multiple stars are present in the instrument field of view. This is especially relevant for observing dim science targets because the density of number of stars increases rapidly with star magnitude. We study the effect of star confusion on the SIM astrometric performance due to systematic fringe errors caused by the extra photons from the confusion star(s}. Since star confusion from multiple stars may be analyzed as a linear superposition of the effect from single star confusion, we quantify the astrometric errors due to single star confusion surveying over many spectral types, including AOV, FOV, K5III, and MOV, and for various visual magnitude differences. To the leading order, the star confusion effect is characterized by the magnitude difference, spectral difference, and the angular separation between the target and confusion stars.Strategies for dealing with star confusion are presented. For example, since the presence of additional sources in the field of view leads to inconsistent delay estimates from different channels, with sufficient signal to noise ratio, the star confusion can be detected using chi-square statistics of fringe measurements from multiple spectral channels. An interesting result is that the star confusion can be detected even though the interferometer cannot resolve the separation between the target and confusion stars when their spectra are sufficiently different. Other strategies for mitigating the star confusion effect are also discussed.

crowded field↗

Methods, systems, and apparatuses for calculating global fluence for neutron and photon monte carlo transport using expected value estimators

Global fluence estimators may be calculated on accelerators and processors for neutron and photon Monte Carlo transport. Monte Carlo random walk simulation may be performed on the processors and the calculation of a Volumetric-Ray-Casting (VRC) estimator may be offloaded to the accelerators. The VRC estimator may modify an expected-value estimator to extend a pseudo-particle ray along the direction of the emitted particle from source and collision event through not only the event volume, but also through all volumes that describe the problem geometry. Additionally, many pseudo-particle rays may be sampled per event, rather than just a single pseudo-particle ray per event, in order to provide more complete angular coverage.

Sweezy, Jeremy Ed↗

New Insertion Device Control System for the APS Upgrade

New Hybrid Permanent Magnet Undulators (HPMUs) have been designed and manufactured using servo motors for precise and reliable gap motion control for the Advanced Photon Source Upgrade (APS-U) project. Meanwhile, existing HPMUs equipped with legacy stepper motors are systematically replaced with servo motors. In parallel with mechanical modifications of the undulators, a comprehensive upgrade has been implemented for the control of the devices. This upgrade includes integration of standardized industrial components for replacement of motor controllers and motor drives using the Kollmorgen Programmable Controller Multi-axis Master (PCMM) controllers and the AKD2G series servo drives. Soft Input Output Controllers (IOCs) are developed and deployed to replace the legacy VME-based IOCs for both single-period undulators and Revolver undulators. In this paper, we will present the architecture of the new insertion device control system, including control mechanisms, interlock protocols, and tools for diagnostics and troubleshooting.

Li, W.↗

A balloon-borne Ge/Li/ spectrometer for gamma-ray astronomy

On June 10, 1974, a new high-resolution gamma ray spectrometer operating in the energy range of 0.05 to 10 MeV was successfully balloon-flight tested. This system uses four 40 cu cm Ge(Li) crystals in a single cryostat as prime sensors. A 6.35 cm thick CsI (Na) shield provides background rejection and collimation, defining a solid angle of 0.095 sr. Cooling is provided by a liquid-nitrogen dewar. The system was highly stable with spectral resolution of better than 2.5 keV at 1 MeV for the flight duration. The background total count rate was about 20 counts/sec. Numerous lines were observed, most of which originated from secondary neutron interactions in the spectrometer. The sensitivity of the system to line emissions originating in cosmic point sources is 0.0001 to 0.001 photons per sq cm s over the energy range.

Jacobson, A. S.↗

Gravitational analog of the canonical acoustic black hole in Einstein-scalar-Gauss-Bonnet theory

In this work, in the context of modified gravity, a curved spacetime analogous to the 'canonical acoustic black hole (CABH)' is constructed. The source is a self-interacting scalar field which is non-minimally coupled to gravity through the Gauss–Bonnet invariant. The scalar-Gauss–Bonnet coupling function is characterized by three positive parameters: σ with units of (length), μ with units of (length)4, and a dimensionless parameter s, thus defining a three-parameter model for which the line element of CABH is a solution. The spacetime is equipped with spherical and static symmetry and has a single horizon determined in Schwarzschild coordinates by the region r = μ^(1/4). The solution admits a photon sphere at r = (3μ)^(1/4), and it is shown that in the region (3μ)^(1/4) ⩽ r < ∞ the scalar field satisfies the null, weak, and strong energy conditions. Nonetheless, the model with s = 1 has major physical relevance since for this case the scalar field is well defined in the entire region r ⩾ μ^(1/4), while for s ≠ 1 the scalar field blows up on the horizon.

Pedro Cañate↗

Density scaling approximation for Monte-Carlo simulations of radioactive plumes

The release of radioactive gas into the atmosphere can diffuse into large volumes of air downwind from the point of release. The extent of radioactivity can cover thousands of cubic meters of air. For such large volumes, the weather models used to predict the down-wind distribution of the plume and the radiation transport models used to predict the radiation reaching ground-level from the plume can take tens of hours of computer time on multi-node institutional High-Performance Computing facilities. In this paper we focus on the radiation transport aspect of plume modeling. Here, we describe a phenomenological method for approximating the amounts of radiation that reach ground level from large volumes of a static radioactive plume that can be calculated on a stand-alone personal computer in much shorter computation times than those usually needed for such large volume evaluations. We refer to this method as the Density Scaling Approximation (DSA). Its ability to approximate ground-level count rates of large plumes comes from using a small-plume volume with a scaled-up value of air density to simulate the same number of scatterings that occur during transport in larger plume volumes at normal air density. We demonstrate the DSA by using a 100 m-diameter air-filled hemispherical dome geometry with a uniform volumetric activity of 135 Xe gas throughout the air-filled volume. The DSA for a larger dome diameter is obtained by evaluating the 100 m dome with an air density scaled up by the linear ratio of the larger diameter to the 100 m diameter. We find that this approximation works well for dome diameters up to 1200 m – the largest diameter studied and a size more than sufficient for accounting for all the radiation from 135 Xe. Moreover, most of our DSA results can be calculated over 500 times faster than corresponding full-sized geometry with normal air density. To help evaluate the accuracy of the DSA and gain insight into how well it can reproduce different regions of the spectra, we use three, easily understood regions of interest to compare the DSA results to the full-sized geometry at normal air density results. These regions are the full-energy peak, the region of single-Compton scattering, and the region of multiple-Compton scattering. We show how the dominance of the Compton scattering mechanism determines this division and thus provides insight into how Compton scattering is manifested in spectra from photon scattering through air in general, and how well the DSA approximation works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IRAS surface brightness maps of visible reflection nebulae: Evidence for non-equilibrium infrared emission

Surface brightness maps at 12, 25, 60, and 100 microns of 16 visible reflection nebulae were extracted from the Infrared Astronomy Satellite (IRAS) database. The maps were produced by coadding IRAS survey scans over areas centered on the illuminating stars, and have spatial resolutions of 0.9' x 4' at 12 and 25 microns, 1.8' x 4.5' at 60 microns, and 3.6' x 5' at 100 microns. Extended emission in the four IRAS bandpasses was detected in fourteen of the reflection nebulae. The IRAS data were used to measure the flux of the infrared emission associated with each source. The energy distributions show that the 12 micron flux is greater than the 25 micron flux in 11 of the nebulae, and the peak flux occurs in the 60 or 100 micron bandpass in all 16 nebular. The 60 and 100 micron flux can be approximated by blackbodies with temperatures between 30 and 50 K, consistent with temperatures expected from extrapolation of greybody fits to the 60 and 100 micron data. The excess 12 and 25 micron emission is attributed to a nonequilibrium process such as emission from thermal fluctuations of very small grains excited by single ultraviolet photons, or emission from polycyclic aromatic hydrocarbons (PAHs) excited by ultraviolet radiation. The common features of the energy distributions of the 16 reflection nebulae, also seen in the reflection nebulae associated with the Pleiades, suggest that PAHs or very small grains may be found in most reflection nebulae.

Castelaz, M. W.↗

High-energy X-ray radiography with apodized petawatt laser beams

We have produced laser wakefield-accelerated electron beams with energies of 2 GeV in Target Area 1 of the ZEUS facility. These electron beams oscillate in the accelerating structure that is produced in the wake of an ultrashort laser pulse (25 fs). These ’betatron’ oscillations result in the emission of a collimated (4 mrad divergence) beam of high-energy X-ray/gamma photons (on the order of several hundred keV). In this work, we demonstrate the capabilities of the ZEUS laser system by showing that apodizing the laser beam in the near field allows for the production of high-quality betatron X-rays for radiography purposes. This demonstrates that a high-power, large-aperture laser beam could be split into multiple parts to drive betatron X-ray sources from multiple angles or temporal delays into a High Energy Density (HED) target to be probed, enabling pump-probe measurements at multiple temporal delays or tomography on a single shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Low-loss superconducting titanium nitride grown using plasma-assisted molecular beam epitaxy

Titanium nitride (TiN) is a known superconducting material that is attractive for use as passive components in superconducting circuits for both conventional and quantum information devices. In contrast to conventional synthesis techniques, here, plasma-assisted molecular beam epitaxy is reported to produce high-quality TiN on bare silicon wafers. Using a rf-plasma source to crack the nitrogen molecules and a conventional high-temperature effusion cell for titanium, TiN growth is completed under nitrogen-rich conditions. The growth and nucleation is monitored in situ, while the structure and composition are characterized using x-ray diffraction, atomic force microscopy, x-ray photoelectron spectroscopy, secondary ion mass spectroscopy, and scanning transmission electron microscopy. The stoichiometric TiN (111) films sit on an amorphous nitride layer with low impurity concentrations. The films superconduct with Tc=5.4 K, and coplanar waveguide resonators are fabricated with a small center width of 6 μm that demonstrate single-photon quality factors approaching 1M and high-power quality factors over 5M without observing saturation.

Richardson, C. J. K. (ORCID:0000000188175347)↗

Impact Testing of Heat Source Exemplars

This report details the heat source impact testing performed at the Shock Thermodynamics Applied Research Facility (STAR). The purpose of these tests were to measure the impact behavior of a heated Ta-10W tantalum/tungsten alloy heat source exemplar. Each exemplar resembled a cylinder with a rectangular through-hole orthogonal to the cylinder axis-of-symmetry. In each test, the exemplar was impacted by a hardened steel impactor accelerated using the STAR air gun. The exemplars were impacted perpendicular to the through-hole and at an an angle to the cylindrical axis-of-symmetry. The exemplar bar stock source, impact angle, and impact velocity were varied throughout the testing series. High-speed video was used to measure dynamic impact behavior while photon doppler velocimetry (PDV) and shorting pins were used to measure the impact velocity. Foam support structures were used to thermally isolate the exemplar and provide a support structure which was non-perturbative to the impact event. Soft-catch techniques were used to minimize secondary impacts and enable recovery for detailed post-shot analysis. Results indicate positive correlation between exemplar fracture and the variables of impact velocity and impact angle. Exemplar fracture occurred consistently along a single corner of the through-hole.

36 MATERIALS SCIENCE↗