Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Relative fine-structure intensities in two-photon excitation

A discrepancy is pointed out between experimental determinations of the relative intensities for different fine-structure components of the two-photon transitions 2p3P 3p3P in oxygen and 2p3 4S0 - 2p2 3p4D0 in nitrogen, which agreed well with calculations involving a single virtual intermediate level, and a two-photon selection rule dJ not equal to one, derived in a purely theoretical and erroneous treatment of these transitions. Five other experiments are also briefly examined, with the conclusion that relative fine-structure intensities in two-photon transitions are well understood as straightforward extensions of angular momentum coupling in single-photon cases, in accordance with allowed dJ = 0, + or -1, and + or -2 transitions.

Crosley, D. R.↗

Near-infrared observations of the proto-planetary nebula AFGL 618

Near-IR images and spectroscopy of the bipolar protoplanetary nebula AFGL 618 are presented. Emission from molecular hydrogen is detected in the 0.90-1.34-micron spectrum. A visual extinction of 3.4 +4.0/-2.0 mag to the H2-emitting region is derived from molecular hydrogen line ratios. Models of collisionally excited and fluorescent H2 emission are compared with the data: the near-IR H2 spectrum is found to be dominated by emission from collisionally excited molecules at Tex of about 2000 K, but a component of fluorescent emission is also present. It is shown that this type of near-IR spectrum is an excellent tool for discriminating relatively low levels of fluorescent H2 emission from a strong collisionally excited component. Images in the H- and K-bandpasses are analyzed using models which assume single scattering of photons from the central objects. The models indicate that the bipolar axis is inclined to the plane of the sky by about 45 deg. The emission in the H- and K-bands is found to be consistent with single scattering of photons by dust with a distribution such that the dust density increases with increasing stellar latitude and is nearly zero at the poles.

Latter, William B.↗

Transient Sub-Poissonian Distribution for Single-Mode Lasers

In this paper, the transient photon statistics for single-mode lasers is investigated by making use of the theory of quantum electrodynamics. By taking into account of the transitive time l,we obtain the master equation for Jaynes-Cummings model. The relation between the Mandel factor and the time is obtained by directly solving the master equation. The result shows that a transient phenomenon from the transient super-Poissonian distribution to the transient sub-Poissonian distribution occurs for single-mode lasers. In addition, the influences of the thermal light field and the cavity loss on the transient sub-Poissonian distribution are also studied.

Zang, J. Y.↗

Photonic Integrated Circuit (PIC) Device Structures: Background, Fabrication Ecosystem, Relevance to Space Systems Applications, and Discussion of Related Radiation Effects

Electronic integrated circuits are considered one of the most significant technological advances of the 20th century, with demonstrated impact in their ability to incorporate successively higher numbers transistors and construct electronic devices onto a single CMOS chip. Photonic integrated circuits (PICs) exist as the optical analog to integrated circuits; however, in place of transistors, PICs consist of numerous scaled optical components, including such "building-block" structures as waveguides, MMIs, lasers, and optical ring resonators. The ability to construct electronic and photonic components on a single microsystems platform offers transformative potential for the development of technologies in fields including communications, biomedical device development, autonomous navigation, and chemical and atmospheric sensing. Developing on-chip systems that provide new avenues for integration and replacement of bulk optical and electro-optic components also reduces size, weight, power and cost (SWaP-C) limitations, which are important in the selection of instrumentation for specific flight projects. The number of applications currently emerging for complex photonics systems-particularly in data communications-warrants additional investigations when considering reliability for space systems development. This Body of Knowledge document seeks to provide an overview of existing integrated photonics architectures; the current state of design, development, and fabrication ecosystems in the United States and Europe; and potential space applications, with emphasis given to associated radiation effects and reliability.

Body of Knowledge (BOK)↗

Two-dimensional imaging of molecular hydrogen in H2-air diffusion flames using two-photon laser-induced fluorescence

The use of a tunable ArF laser at 193.26 nm to record simultaneous single-laser-shot, planar images of molecular hydrogen and hot oxygen in a turbulent H2-air diffusion flame. Excitation spectra of fuel and oxidant-rich flame zones confirm a partial overlap of the two-photon H2 and single-photon O2 Schumann-Runge absorption bands. UV Rayleigh scattering images of flame structure and estimated detection limits for the H2 two-photon imaging are also presented.

Lempert, W.↗

Photon Counting Detectors for the 1.0 - 2.0 Micron Wavelength Range

We describe results on the development of greater than 200 micron diameter, single-element photon-counting detectors for the 1-2 micron wavelength range. The technical goals include quantum efficiency in the range 10-70%; detector diameter greater than 200 microns; dark count rate below 100 kilo counts-per-second (cps), and maximum count rate above 10 Mcps.

Krainak, Michael A.↗

Adaptive Detector Arrays for Optical Communications Receivers

The structure of an optimal adaptive array receiver for ground-based optical communications is described and its performance investigated. Kolmogorov phase screen simulations are used to model the sample functions of the focal-plane signal distribution due to turbulence and to generate realistic spatial distributions of the received optical field. This novel array detector concept reduces interference from background radiation by effectively assigning higher confidence levels at each instant of time to those detector elements that contain significant signal energy and suppressing those that do not. A simpler suboptimum structure that replaces the continuous weighting function of the optimal receiver by a hard decision on the selection of the signal detector elements also is described and evaluated. Approximations and bounds to the error probability are derived and compared with the exact calculations and receiver simulation results. It is shown that, for photon-counting receivers observing Poisson-distributed signals, performance improvements of approximately 5 dB can be obtained over conventional single-detector photon-counting receivers, when operating in high background environments.

Vilnrotter, V.↗

A Broadband Superconducting Detector Suitable for Use in Large Arrays

Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths. Single-pixel X-ray detectors now have a resolving power of (Delta)E < 5 eV for single 6-keV photons, and future X-ray astronomy missions anticipate the need for 1,000-pixel arrays. Here we report the demonstration of a superconducting detector that is easily fabricated and can readily be incorporated into such an array. Its sensitivity is already within an order of magnitude of that needed for CMB observations, and its energy resolution is similarly close to the targets required for future X-ray astronomy missions.

Day, Peter K.↗

Event Pileup in AXAF's ACIS CCD Camera

AXAF's high resolution mirrors will focus a point source near the optical axis to a spot that is contained within a radius of about two pixels on the ACIS Charge Coupled Devices (CCD) camera. Because of the small spot size, the accuracy to which fluxes and spectral energy distributions of bright point sources can be measured will be degrad3ed by event pileup. Event pileup occurs when two or more X-ray photons arrive simultaneously in a single detection cell on a CCD readout frame. When pileup occurs, ACIS's event detection algorithm registers the photons as a single X-ray event. The pulse height channel of the event will correspond to an energy E approximately E-1 + E-2...E-n, where n is the number of photons registered per detection cell per readout frame. As a result, pileup artificially hardens the observed spectral energy distribution. I will discuss the effort at the AXAF Science Center Lo calibrate pileup in ACIS using focused, nearly monochromatic X-ray source. I will discuss techniques for modeling and correcting pileup effects in polychromatic spectra.

McNamara, Brian R.↗

Segmentation and pulse shape discrimination techniques for rejecting background in germanium detectors

The possibility of rejecting the internal beta-decay background in coaxial germanium detectors by distinguishing between the multi-site energy losses characteristic of photons and the single-site energy losses of electrons in the range 0.2 - 2 MeV is examined. The photon transport was modeled with a Monte Carlo routine. Background rejection by both multiple segmentation and pulse shape discrimination techniques is investigated. The efficiency of a six 1 cm-thick segment coaxial detector operating in coincidence mode alone is compared to that of a two-segment (1 cm and 5 cm) detector employing both front-rear coincidence and PSD in the rear segment to isolate photon events. Both techniques can provide at least 95 percent rejection of single-site events while accepting at least 80 percent of the multi-site events above 500 keV.

Roth, J.↗

Directional coupler for optical waveguides

Feasibility study of transmitting optical energy in single mode through photonic waveguides results in a conceptual directional coupler consisting of two types of optical waveguides /a stratified /core/ dielectric and a mirror wall/. Waveguide medium analysis produced formulation of mode cutoff conditions, field distributions, and propagation characteristics.

Schineller, E. R.↗

Degree and direction of polarization of multiple scattered light. I - Homogeneous cloud layers.

It is shown that the Monte Carlo method can provide useful information on the polarization and its direction for homogeneous layers corresponding to the haze C, nimbostratus, and ice crystals models. Results for various optical thicknesses and two solar zenith angles show the variation with these parameters. In most cases the direction of polarization with respect to the meridian plane (which contains the outgoing photon) does not change appreciably with the optical thickness of the scattering layer, so that the conclusion that the direction of polarization is determined mainly by the direction of the incident and scattered photons, obtained for single scattering, should apply approximately when multiple scattering is taken into account.

Kattawar, G. W.↗

An X-ray shadowgraph to locate transient high-energy celestial sources

A new technique has been developed to locate strong, transient X-ray sources such as the recently discovered gamma ray bursts. The instrument, termed a shadowgraph, locates sources by detecting the X-ray shadow cast by a large occulting mask pattern on an imaging detector. Angular resolutions of from 2 to 10 arc minutes are obtainable while essentially full sky coverage is maintained. The optimum energy range of operation is between 20 keV and 100 keV. The high efficiency X-ray imaging detectors, which make it possible to locate bursts with intensities down to approximately 10 photons/sq cm sec, are capable of detecting single 20 keV photons with a spatial resolution of approximately 0.2 mm. The detectors consist of an X-ray to optical conversion phosphor, a multistage image intensifier, and a CCD image readout.

Fishman, G. J.↗

Radiation damage in scientific charge-coupled devices

Radiation damage is reported on CCDs (charge-coupled devices) that have been primarily exposed to 1.25-MeV gamma rays (Co-60 source). Two important classes of radiation damage are discussed, namely, bulk and ionization effects. Bulk damage or displacement damage is a process in which silicon atoms are displaced from their normal lattice positions by high-energy photons or particles. Single atomic displacements or cluster defect damage is produced, depending on the energy and type of radiation experienced by the detector. Bulk damage creates trapping sites within the CCD's signal channel which in turn degrades charge-transfer efficiency.

Janesick, James↗

A new near-infrared imaging study of AFGL 2688

The object AFGL 2688 is a bipolar nebula surrounding a post-asymptotic giant branch star and is in transition toward becoming a planetary nebula. We present new NIR images in the I, J, H, and K bandpasses. These images reveal a wealth of structure in the nebula not previously seen. We find that the northern lobe is not smooth, but clumpy. There is evidence in the I-band image for periodic variations in mass-loss rate. In addition, we present narrowband images centered on the V = 1 - 0 S(1) line of molecular hydrogen and nearby continuum. The narrowband images reveal that broadband flux found in the equatorial region is dominated by line emission from vibrationally excited molecular hydrogen. H2 emission is also present in the lobes. Our K-band images show the equatorial emission to be in the form of a ring or torus extending around the object at a distance R about 7 x 10 exp 16 (D/1 kpc) cm. Mechanisms for exciting the equatorial H2 emission are discussed; we conclude that shocks are the only plausible source. We have analyzed the broadband images using models which assume single scattering of photons from the central star. We find that the bipolar axis is inclined to the plane of the sky by i about 5 deg. The images are best reproduced by models in which the density of scattering dust decreases fairly rapidly with increasing stellar latitude, with little or no dust near the poles. Furthermore, the optical depth is found to have very little wavelength dependence, which implies that the dust in AFGL 2688 is different from that in the interstellar medium.

Latter, William B.↗

Characterization of microgravity effects on bone structure and strength using fractal analysis

The effect of micro-gravity on the musculoskeletal system has been well studied. Significant changes in bone and muscle have been shown after long term space flight. Similar changes have been demonstrated due to bed rest. Bone demineralization is particularly profound in weight bearing bones. Much of the current techniques to monitor bone condition use bone mass measurements. However, bone mass measurements are not reliable to distinguish Osteoporotic and Normal subjects. It has been shown that the overlap between normals and osteoporosis is found for all of the bone mass measurement technologies: single and dual photon absorptiometry, quantitative computed tomography and direct measurement of bone area/volume on biopsy as well as radiogrammetry. A similar discordance is noted in the fact that it has not been regularly possible to find the expected correlation between severity of osteoporosis and degree of bone loss. Structural parameters such as trabecular connectivity have been proposed as features for assessing bone conditions. In this report, we use fractal analysis to characterize bone structure. We show that the fractal dimension computed with MRI images and X-Ray images of the patella are the same. Preliminary experimental results show that the fractal dimension computed from MRI images of vertebrae of human subjects before bedrest is higher than during bedrest.

Acharya, Raj S.↗

The pulsed hard X-ray spectrum of PSR B1509-58

Oriented Scintillation Spectrometer Experiment (OSSE) observed the 150 ms X-ray pulsar PSR B1509-58 m the supernova remnant MSH 15-52 for 4 weeks in 1992. The pulsed spectrum from 50 keV to 5 MeV is well represented by a single-power-law photon spectrum of the form (3.14 +/- 0.16) x 10(exp -6) x (E/118.5 keV)(exp -1.68 +/- -0.09) photons cm(exp -2)s(exp -1)keV(exp -1). This is significantly harder than the Crab pulsar spectrum in this energy range. The Ginga soft X-ray spectrum (2-60 keV) reported by Kawai et al. is significantly harder than the observed OSSE spectrum and predicts a flux 2 times higher than we observe in the approximately 55-170 keV energy band. This requires a break to a steeper spectrum somewhere in the intermediate energy range (approximately 20-80 keV). The spectrum must soften again at higher energies or the pulsar would have easily been detected by EGRET, COS B, and SAS 2.

Matz, S.↗

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

We have obtained the first data on the multiplexed operation of titanium hot-electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far-infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (approximately microseconds at 300-400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per ??/2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near- IR photons (1550 nm) with a time constant of 3.5 ?s. Follow-on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

microwave readout↗