Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single point correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A short story of imaging and spectroscopy of two-dimensional materials by scanning transmission electron microscopy

Here we present a short historical account of when single adatom impurities where first identified in two-dimensional materials by scanning transmission electron microscopy (STEM). We also present a study of the graphene low-loss (below 50 eV) response as a function of number of layers using electron energy-loss spectroscopy (EELS). The study shows that as few as three layers of graphene behave as bulk graphite for losses above 10 eV We also show examples of how point and extended defects can easily be resolved and structural dynamics can be readily capture by using aberration-corrected STEM imaging. Lastly, we show that the new generation of monochromators has opened up possibilities to explore new physics with an electron microscope. All these capabilities were enabled by the development of spherical aberration correctors and monochromators, where Ondrej Krivanek has played a key role.

2D materials↗

Laser-Accelerated Proton Beams as Diagnostics for Cultural Heritage

This paper introduces the first use of laser-generated proton beams as diagnostic for materials of interest in the domain of Cultural Heritage. Using laser-accelerated protons, as generated by interaction of a high-power short-pulse laser with a solid target, we can produce proton-induced X-ray emission spectroscopies (PIXE). By correctly tuning the proton flux on the sample, we are able to perform the PIXE in a single shot without provoking more damage to the sample than conventional methodologies. We verify this by experimentally irradiating materials of interest in the Cultural Heritage with laser-accelerated protons and measuring the PIXE emission. The morphological and chemical analysis of the sample before and after irradiation are compared in order to assess the damage provoked to the artifact. Monte Carlo simulations confirm that the temperature in the sample stays safely below the melting point. Compared to conventional diagnostic methodologies, laser-driven PIXE has the advantage of being potentially quicker and more efficient.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NASA Tech Briefs, March 2007

Topics include: Advanced Systems for Monitoring Underwater Sounds; Wireless Data-Acquisition System for Testing Rocket Engines; Processing Raw HST Data With Up-to-Date Calibration Data; Mobile Collection and Automated Interpretation of EEG Data; System for Secure Integration of Aviation Data; Servomotor and Controller Having Large Dynamic Range; Digital Multicasting of Multiple Audio Streams; Translator for Optimizing Fluid-Handling Components; AIRSAR Web-Based Data Processing; Pattern Matcher for Trees Constructed From Lists; Reducing a Knowledge-Base Search Space When Data Are Missing; Ground-Based Correction of Remote-Sensing Spectral Imagery; State-Chart Autocoder; Pointing History Engine for the Spitzer Space Telescope; Low-Friction, High-Stiffness Joint for Uniaxial Load Cell; Magnet-Based System for Docking of Miniature Spacecraft; Electromechanically Actuated Valve for Controlling Flow Rate; Plumbing Fixture for a Microfluidic Cartridge; Camera Mount for a Head-Up Display; Core-Cutoff Tool; Recirculation of Laser Power in an Atomic Fountain; Simplified Generation of High-Angular-Momentum Light Beams; Imaging Spectrometer on a Chip; Interferometric Quantum-Nondemolition Single-Photon Detectors; Ring-Down Spectroscopy for Characterizing a CW Raman Laser; Complex Type-II Interband Cascade MQW Photodetectors; Single-Point Access to Data Distributed on Many Processors; Estimating Dust and Water Ice Content of the Martian Atmosphere From THEMIS Data; Computing a Stability Spectrum by Use of the HHT; Theoretical Studies of Routes to Synthesis of Tetrahedral N4; Estimation Filter for Alignment of the Spitzer Space Telescope; Antenna for Measuring Electric Fields Within the Inner Heliosphere; Improved High-Voltage Gas Isolator for Ion Thruster; and Hybrid Mobile Communication Networks for Planetary Exploration.

Source record↗

Hand Calculation Methods for Nuclear Criticality Safety

This primer provides an overview of the most common hand calculation methods used for criticality safety calculations. The most widely used tools available to a nuclear criticality safety (NCS) practitioner are probably the common Monte Carlo or deterministic criticality safety codes, which can be used to model very complex systems. However, use of these codes can obscure the parameters to which a particular fissile system may be sensitive, whereas the hand calculation methods can be used to delve into the ways each parameter may affect the reactivity of a fissile material system. Furthermore, practitioners must avoid using computer codes as devices that take inputs and simply provide outputs (i.e., a “black box”). Many years ago, pioneers such as Joe Thomas, David Smith, and Hugh Paxton, among others in the field of nuclear criticality safety, took the time before the advent of high-speed desktop computers to create simple hand methods for criticality safety analyses. Some of the methods can be used for single fissile units; others are applicable to fissile units arranged into simple array configurations. This primer discusses the applicability of the various methods, illustrates how they are used, and provides an interpretation of the various results. The NCS practitioner will need to spend time to master the methods that could be most useful; however, they can provide the practitioner with fast and accurate answers to criticality safety problems if they are used correctly and if critical data exist for the problem at hand. Hand calculation methods can be used as a starting point for more advanced calculations, and in many circumstances, they can provide sensitivity and perturbation information more quickly than using a criticality code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A low-power, high-throughput maximum-likelihood convolutional decoder chip for NASA's 30/20 GHz program

It is pointed out that the NASA 30/20 GHz program will place in geosynchronous orbit a technically advanced communication satellite which can process time-division multiple access (TDMA) information bursts with a data throughput in excess of 4 GBPS. To guarantee acceptable data quality during periods of signal attenuation it will be necessary to provide a significant forward error correction (FEC) capability. Convolutional decoding (utilizing the maximum-likelihood techniques) was identified as the most attractive FEC strategy. Design trade-offs regarding a maximum-likelihood convolutional decoder (MCD) in a single-chip CMOS implementation are discussed.

Mccallister, R. D.↗

Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-associated Refractory Hepatic Encephalopathy by Shunt Reduction Using the Parallel Technique: Outcomes of a Retrospective Case Series

Purpose: To investigate the reproducibility and technical and clinical success of the parallel technique of transjugular intrahepatic portosystemic shunt (TIPS) reduction in the management of refractory hepatic encephalopathy (HE). Materials and Methods: A 10-mm-diameter self-expanding stent graft and a 5-6-mm-diameter balloon-expandable stent were placed in parallel inside the existing TIPS in 8 patients via a dual unilateral transjugular approach. Changes in portosystemic pressure gradient and HE grade were used as primary end points. Results: TIPS reduction was technically successful in all patients. Mean {+-} standard deviation portosystemic pressure gradient before and after shunt reduction was 4.9 {+-} 3.6 mmHg (range, 0-12 mmHg) and 10.5 {+-} 3.9 mmHg (range, 6-18 mmHg). Duration of follow-up was 137 {+-} 117.8 days (range, 18-326 days). Clinical improvement of HE occurred in 5 patients (62.5%) with resolution of HE in 4 patients (50%). Single episodes of recurrent gastrointestinal hemorrhage occurred in 3 patients (37.5%). These were self-limiting in 2 cases and successfully managed in 1 case by correction of coagulopathy and blood transfusion. Two of these patients (25%) died, one each of renal failure and hepatorenal failure. Conclusion: The parallel technique of TIPS reduction is reproducible and has a high technical success rate. A dual unilateral transjugular approach is advantageous when performing this procedure. The parallel technique allows repeat bidirectional TIPS adjustment and may be of significant clinical benefit in the management of refractory HE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252 Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROBING MILLISECOND PULSAR EMISSION GEOMETRY USING LIGHT CURVES FROM THE FERMI/LARGE AREA TELESCOPE

An interesting new high-energy pulsar sub-population is emerging following early discoveries of gamma-ray millisecond pulsars (MSPs) by the Fermi Large Area Telescope (LAT). We present results from three-dimensional emission modeling, including the special relativistic effects of aberration and time-of-flight delays and also rotational sweepback of B-field lines, in the geometric context of polar cap (PC), outer gap (OG), and two-pole caustic (TPC) pulsar models. In contrast to the general belief that these very old, rapidly rotating neutron stars (NSs) should have largely pair-starved magnetospheres due to the absence of significant pair production, we find that most of the light curves are best fit by TPC and OG models, which indicates the presence of narrow accelerating gaps limited by robust pair production-even in these pulsars with very low spin-down luminosities. The gamma-ray pulse shapes and relative phase lags with respect to the radio pulses point to high-altitude emission being dominant for all geometries. We also find exclusive differentiation of the current gamma-ray MSP population into two MSP sub-classes: light curve shapes and lags across wavebands impose either pair-starved PC (PSPC) or TPC/OG-type geometries. In the first case, the radio pulse has a small lag with respect to the single gamma-ray pulse, while the (first) gamma-ray peak usually trails the radio by a large phase offset in the latter case. Finally, we find that the flux correction factor as a function of magnetic inclination and observer angles is typically of order unity for all models. Our calculation of light curves and flux correction factor for the case of MSPs is therefore complementary to the 'ATLAS paper' of Watters et al. for younger pulsars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-BRC-16: Theory and Clinical Implications of the Constant Dosimetric Leaf Gap (DLG) Approximation

Purpose: Commercial dose calculation algorithms incorporate a single DLG value for a given beam energy that is applied across an entire treatment field. However, the physical processes associated with beam generation and dose delivery suggest that the DLG is not constant. The aim of this study is to evaluate the variation of DLG among all leaf pairs, to quantify how this variation impacts delivered dose, and to establish a novel method to correct dose distributions calculated using the approximation of constant DLG. Methods: A 2D diode array was used to measure the DLG for all 60 leaf pairs at several points along each leaf pair travel direction. This approach was validated by comparison to DLG values measured at select points using a 0.6 cc ion chamber with the standard formalism. In-house software was developed to enable incorporation of position dependent DLG values into dose distribution optimization and calculation. The accuracy of beam delivery of both the corrected and uncorrected treatment plans was studied through gamma pass rate evaluation. A comparison of DVH statistics in corrected and uncorrected treatment plans was made. Results: The outer 20 MLC leaf pairs (1.0 cm width) have DLG values that are 0.32 mm (mean) to 0.65 mm (maximum) lower than the central leaf-pair. VMAT plans using a large number of 1 cm wide leaves were more accurately delivered (gamma pass rate increased by 5%) and dose coverage was higher (D100 increased by 3%) when the 2D DLG was modeled. Conclusion: Using a constant DLG value for a given beam energy will result in dose optimization, dose calculation and treatment delivery inaccuracies that become significant for treatment plans with high modulation complexity scores delivered with 1 cm wide leaves.

60 APPLIED LIFE SCIENCES↗

Analytic corrections to CFD heating predictions accounting for changes in surface catalysis

Integral boundary-layer solution techniques applicable to the problem of determining aerodynamic heating rates of hypersonic vehicles in the vicinity of stagnation points and windward centerlines are briefly summarized. A new approach for combining the insight afforded by integral boundary-layer analysis with comprehensive (but time intensive) computational fluid dynamic (CFD) flowfield solutions of the thin-layer Navier-Stokes equations is described. The approach extracts CFD derived quantities at the wall and at the boundary layer edge for inclusion in a post-processing boundary-layer analysis. It allows a designer at a workstation to address two questions, given a single CFD solution. (1) How much does the heating change for a thermal protection system with different catalytic properties than was used in the original CFD solution? (2) How does the heating change at the interface of two different TPS materials with an abrupt change in catalytic efficiency? The answer to the second question is particularly important, because abrupt changes from low to high catalytic efficiency can lead to localized increase in heating which exceeds the usually conservative estimate provided by a fully catalytic wall assumption.

Gnoffo, Peter A.↗

Generating Dynamic System Matrices for Dynamic SPECT

The purpose of the computer program is to generate system matrices that model data acquisition process in dynamic single photon emission computed tomography (SPECT). The application is for the reconstruction of dynamic data from projection measurements that provide the time evolution of activity uptake and wash out in an organ of interest. The measurement of the time activity in the blood and organ tissue provide time-activity curves (TACs) that are used to estimate kinetic parameters. The program provides a correct model of the in vivo spatial and temporal distribution of radioactive in organs. The model accounts for the attenuation of the internal emitting radioactivity, it accounts for the vary point response of the collimators, and correctly models the time variation of the activity in the organs. One important application where the software is being used in a measuring the arterial input function (AIF) in a dynamic SPECT study where the data are acquired from a slow camera rotation. Measurement of the arterial input function (AIF) is essential to deriving quantitative estimates of regional myocardial blood flow using kinetic models. A study was performed to evaluate whether a slowly rotating SPECT system could provide accurate AIF's for myocardial perfusion imaging (MPI). Methods: Dynamic cardiac SPECT was first performed in human subjects at rest using a Phillips Precedence SPECT/CT scanner. Dynamic measurements of Tc-99m-tetrofosmin in the myocardium were obtained using an infusion time of 2 minutes. Blood input, myocardium tissue and liver TACs were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. Results: The spatiotemporal 4D ML-EM reconstructions gave more accurate reconstructions that did standard frame-by-frame 3D ML-EM reconstructions. From additional computer simulations and phantom studies, it was determined that a 1 minute infusion with a SPECT system rotation speed providing 180 degrees of projection data every 54s can produce measurements of blood pool and myocardial TACs. This has important application in the circulation of coronary flow reserve using rest/stress dynamic cardiac SPECT. They system matrices are used in maximum likelihood and maximum a posterior formulations in estimation theory where through iterative algorithms (conjugate gradient, expectation maximization, or maximum a posteriori probability algorithms) the solution is determined that maximizes a likelihood or a posteriori probability function.

Source record↗

Predicting Cycle-to-Cycle Variation With Concurrent Cycles in a Gasoline Direct Injected Engine With Large Eddy Simulations

High cycle-to-cycle variation (CCV) is detrimental to engine performance, as it leads to poor combustion and high noise and vibration. In this work, CCV in a gasoline engine is studied using large eddy simulation (LES). The engine chosen as the basis of this work is a single-cylinder gasoline direct injection (GDI) research engine. Two stoichiometric part-load engine operating points (6 BMEP, 2000 RPM) were evaluated: a non-dilute (0% EGR) case and a dilute (18% EGR) case. The experimental data for both operating conditions had 500 cycles. The measured CCV in IMEP was 1.40% for the non-dilute case and 7.78% for the dilute case. To estimate CCV from simulation, perturbed concurrent cycles of engine simulations were compared to consecutively obtained engine cycles. The motivation behind this is that running consecutive cycles to estimate CCV is quite time-consuming. For example, running 100 consecutive cycles requires 2–3 months (on a typical cluster), however, by running concurrently one can potentially run all 100 cycles at the same time and reduce the overall turnaround time for 100 cycles to the time taken for a single cycle (2 days). The goal of this paper is to statistically determine if concurrent cycles, with a perturbation applied to each individual cycle at the start, can be representative of consecutively obtained cycles and accurately estimate CCV. 100 cycles were run for each case to obtain statistically valid results. The concurrent cycles began at different timings before the combustion event, with the motivation to identify the closest time before spark to minimize the run time. Only a single combustion cycle was run for each concurrent case. The calculated standard deviation of peak pressure and coefficient of variance (COV) of indicated mean effective pressure (IMEP) were compared between the consecutive and concurrent methods to quantify CCV. It was found that the concurrent method could be used to predict CCV with either a velocity or numerical perturbation. Here, a large and small velocity perturbation were compared and both produced correct predictions, implying that the type of perturbation is not important to yield a valid realization. Starting the simulation too close to the combustion event, at intake valve close (IVC) or at spark timing, under-predicted the CCV. When concurrent simulations were initiated during or before the intake even, at start of injection (SOI) or earlier, distinct and valid realizations were obtained to accurately predict CCV for both operating points. By simulating CCV with concurrent cycles, the required wall clock time can be reduced from 2–3 months to 1–2 days. Additionally, the required core-hours can be reduced up to 41%, since only a portion of each cycle needs to be simulated.

42 ENGINEERING↗

Right-handed charged currents in the era of the Large Hadron Collider

We discuss the phenomenology of right-handed charged currents in the frame-work of the Standard Model Effective Field Theory, in which they arise due to a single gauge-invariant dimension-six operator. We study the manifestations of the nine complex couplings of the W to right-handed quarks in collider physics, flavor physics, and low-energy precision measurements. We first obtain constraints on the couplings under the assumption that the right-handed operator is the dominant correction to the Standard Model at observable energies. Here, we subsequently study the impact of degeneracies with other Beyond-the-Standard-Model effective interactions and identify observables, both at colliders and low-energy experiments, that would uniquely point to right-handed charged currents.

43 PARTICLE ACCELERATORS↗

Relating flow resistance to equivalent roughness

Describing flow resistance using the physical properties of an underlying surface is a recalcitrant problem in overland flow models. If discharge measurements are available, an equivalent roughness (e.g., Manning’s n) can be calibrated to represent the effects of surface properties within the domain with a single numerical value. Alternatively, the flow resistance can be estimated from discharge and velocity measured at a point, typically a runoff plot outlet. However, such experimental estimates are often inconsistent with the equivalent roughness determined from calibration to discharge, even if both derive from the same dataset. For example, if Manning’s equation is used to parameterize flow resistance, the Manning’s n obtained by calibrating a model to discharge differs from the value of n calculated from measured flow and velocity at the hillslope outlet. Here, this discrepancy is resolved by deriving a correction factor relating experimentally-determined flow resistance to the equivalent roughness. The derived correction factor is tested for four commonly-used resistance formulations using 129 rainfall simulator experiments. The correction factor is necessary to reproduce measured velocities, and yields minor improvements in discharge prediction. Plain Language Summary: Accurate runoff prediction is needed for land and water management in dryland regions, where sporadic and limited rainfall necessitate efficient water use and drought mitigation strategies. The skill of runoff models is known to be hindered by out ability to estimate flow resistance, which is the quantity that describes how energy is lost from flowing water to the underlying surface. Typically, models represent flow resistance with an equivalent roughness, e.g., Manning’s n, that is adjusted until the model can reproduce available discharge observations at watershed scale. However, the flow resistance measured in plot-scale experiments (1–10 m) often exceeds equivalent roughness coefficients by a factor of 10. This means that the direct use of plot-scale experimental data to parameterize runoff models could cause errors in discharge and runoff velocity predictions. Here, we resolve these differences by deriving an analytic correction factor that relates flow resistance to the equivalent roughness required for models to reproduce experimental velocity and discharge data. This correction factor is tested using rainfall simulator data from 129 experiments performed in the US Southwest covering a wide range of precipitation intensities, soil textures and vegetation types. Use of the correction factor substantially improves model prediction of flow velocity, which is needed for reproducing the timing of flood events and the estimation of erosion.

54 ENVIRONMENTAL SCIENCES↗

Investigation of an implantable dosimeter for single-point water equivalent path length verification in proton therapy

Purpose: In vivo range verification in proton therapy is highly desirable. A recent study suggested that it was feasible to use point dose measurement for in vivo beam range verification in proton therapy, provided that the spread-out Bragg peak dose distribution is delivered in a different and rather unconventional manner. In this work, the authors investigate the possibility of using a commercial implantable dosimeter with wireless reading for this particular application. Methods: The traditional proton treatment technique delivers all the Bragg peaks required for a SOBP field in a single sequence, producing a constant dose plateau across the target volume. As a result, a point dose measurement anywhere in the target volume will produce the same value, thus providing no information regarding the water equivalent path length to the point of measurement. However, the same constant dose distribution can be achieved by splitting the field into a complementary pair of subfields, producing two oppositely ''sloped'' depth-dose distributions, respectively. The ratio between the two distributions can be a sensitive function of depth and measuring this ratio at a point inside the target volume can provide the water equivalent path length to the dosimeter location. Two types of field splits were used in the experiment, one achieved by the technique of beam current modulation and the other by manipulating the location and width of the beam pulse relative to the range modulator track. Eight MOSFET-based implantable dosimeters at four different depths in a water tank were used to measure the dose ratios for these field pairs. A method was developed to correct the effect of the well-known LET dependence of the MOSFET detectors on the depth-dose distributions using the columnar recombination model. The LET-corrected dose ratios were used to derive the water equivalent path lengths to the dosimeter locations to be compared to physical measurements. Results: The implantable dosimeters measured the dose ratios with a reasonable relative uncertainty of 1%-3% at all depths, except when the ratio itself becomes very small. In total, 55% of the individual measurements reproduced the water equivalent path lengths to the dosimeters within 1 mm. For three dosimeters, the difference was consistently less than 1 mm. Half of the standard deviations over the repeated measurements were equal or less than 1 mm. Conclusions: With a single fitting parameter, the LET-correction method worked remarkably well for the MOSFET detectors. The overall results were very encouraging for a potential method of in vivo beam range verification with millimeter accuracy. This is sufficient accuracy to expand range of clinical applications in which the authors could use the distal fall off of the proton depth dose for tight margins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Shuttle Infrared Telescope Facility /SIRTF/ fine guidance sensor

Fine guidance technology development for the Shuttle Infrared Telescope Facility (SIRTF) centers upon the use of a single multiple-star-tracking sensor to provide the position information necessary to produce three-axis attitude control signals for precision payload pointing. The effort described in this paper is concerned with the development of a fine guidance sensor that employs a high-density charge-coupled imaging device for producing position information signals by using star fields. Multiple star position information produces three-axis position error signals that are used to update inertial reference gyros. The sensor employs advanced position interpolation algorithms to enhance field-of-view resolution and to correct for optical aberrations inherent in spatially chopped star images resulting from the telescope's movable secondary mirror. Operation of the sensor is under the control of a high-performance microcomputer that provides both autonomy and flexibility in a guidance application.

Salomon, P. M.↗

Predicting vapor liquid equilibria using density functional theory: A case study of argon

Predicting vapor liquid equilibria (VLE) of molecules governed by weak van der Waals (vdW) interactions using the first principles approach is a significant challenge. Due to the poor scaling of the post Hartree-Fock wave function theory with system size/basis functions, the Kohn-Sham density functional theory (DFT) is preferred for systems with a large number of molecules. However, traditional DFT cannot adequately account for medium to long range correlations which are necessary for modeling vdW interactions. Recent developments in DFT such as dispersion corrected models and nonlocal van der Waals functionals have attempted to address this weakness with a varying degree of success. In this work, we predict the VLE of argon and assess the performance of several density functionals and the second order Møller-Plesset perturbation theory (MP2) by determining critical and structural properties via first principles Monte Carlo simulations. PBE-D3, BLYP-D3, and rVV10 functionals were used to compute vapor liquid coexistence curves, while PBE0-D3, M06-2X-D3, and MP2 were used for computing liquid density at a single state point. Here, the performance of the PBE-D3 functional for VLE is superior to other functionals (BLYP-D3 and rVV10). At T = 85 K and P = 1 bar, MP2 performs well for the density and structural features of the first solvation shell in the liquid phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of downscaled wind speeds and parameterised gusts for recent and historical windstorms in Switzerland

Assessments of local-scale windstorm hazard require highly resolved spatial information on wind speeds and gusts. In this study, maximum (peak) sustained wind speeds on a 3-km horizontal grid over Switzerland are obtained by dynamical downscaling from the Twentieth Century Reanalysis (20CR) employing the Weather Research and Forecasting (WRF) model. Subsequently, simulated peak gusts are derived using four wind gust parameterizations (WGPs). Evaluations against observations at 63 locations in complex terrain include four high-impact windstorms (occurring in 1919, 1935, 1990, and 1999) and 14 recent windstorms (occurring between 1993 and 2011). Peak sustained wind speeds and directions are generally well simulated, although wind speeds are mostly overestimated. In general, performance and skill measures are best for locations on the Swiss Plateau and inferior for Alpine mountain and valley locations. An independent ERA-Interim WRF downscaling configuration produces overall comparable results, implying that the 20CR ensemble mean is a reliable data set in dynamical downscaling exercises. The four evaluated WGPs largely reproduce the observed gustiness, although the timing and magnitude of the peak gusts are not regularly captured. None of the WGPs stands out as single best for the complex topography of Switzerland. Differences among the WGPs are small compared to the biases inherited from the sustained-wind part in the WGP formulations. All WGPs transform overestimated peak sustained winds into underestimated peak gusts, which points to an underrepresentation of the turbulent part in the WGP formulations. The range of simulated peak gusts from downscaling all 20CR ensemble members does not reliably include the observed peak gust, indicating limited benefit in applying an ensemble approach. Despite the limitations, we infer that with spatial optimisations of the simulation (e.g. by bias correction or adaptation of the WGP schemes), downscaling of 20CR input is an efficient option for high-resolution assessments of windstorm hazard and risk in Switzerland.

20CR↗