Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Camera for Monitoring Vegetation

Video camera uses solid-state imaging devices and light filters to bring out subtle spectral differences between healthy and stressed vegetation differences not readily detectable with infrared film cameras. Camera employs two detector arrays. Video camera made small and easily portable. Eliminates need for refrigeration of film before use, and provides instantaneous output with no delay for film development.

Martin, T. Z.↗

To catch a comet: Technical overview of CAN DO G-324

The primary photographing of aboard STS 61-E. INTRODUCTION objective of the C.E. Williams Middle School Get Away Special "CAN DO" is the Comet Halley. As it is currently scheduled, G-324 will fly in March of 1986 The project will involve middle school students, grades 6 through 8, in the study and interpretation of astronomical photographs and techniques. -The-objectives of these studies are detailed in another paper to be presented at this symposium. 6-324 is contained in a 5 cubic foot G.A.S. Canister with an opening door and pyrex window for photography. It will be pressurized with one atmosphere of dry nitrogen. Three 35mm still cameras with 250 exposure film backs and different focal length lenses will be fired by a combination of automatic timer and an active comet detector. A lightweight 35mm movie camera will shoot single exposures at about 4 minute intervals to give an overlapping "skymap" of the mission. The fifth camera is a solid state television camera specially constructed for detection of the comet by the microprocessor. In addition to the photographic goals of CAN DO, the canister also contains a separate package of middle school student designed passive experiments. These-projects will be described in detail in the accompanying paper on educational goals.

Thomas J. O'Brien↗

An Acoustic Charge Transport Imager for High Definition Television

This project, over its term, included funding to a variety of companies and organizations. In addition to Georgia Tech these included Florida Atlantic University with Dr. William E. Glenn as the P.I., Kodak with Mr. Mike Richardson as the P.I. and M.I.T./Polaroid with Dr. Richard Solomon as the P.I. The focus of the work conducted by these organizations was the development of camera hardware for High Definition Television (HDTV). The focus of the research at Georgia Tech was the development of new semiconductor technology to achieve a next generation solid state imager chip that would operate at a high frame rate (I 70 frames per second), operate at low light levels (via the use of avalanche photodiodes as the detector element) and contain 2 million pixels. The actual cost required to create this new semiconductor technology was probably at least 5 or 6 times the investment made under this program and hence we fell short of achieving this rather grand goal. We did, however, produce a number of spin-off technologies as a result of our efforts. These include, among others, improved avalanche photodiode structures, significant advancement of the state of understanding of ZnO/GaAs structures and significant contributions to the analysis of general GaAs semiconductor devices and the design of Surface Acoustic Wave resonator filters for wireless communication. More of these will be described in the report. The work conducted at the partner sites resulted in the development of 4 prototype HDTV cameras. The HDTV camera developed by Kodak uses the Kodak KAI-2091M high- definition monochrome image sensor. This progressively-scanned charge-coupled device (CCD) can operate at video frame rates and has 9 gm square pixels. The photosensitive area has a 16:9 aspect ratio and is consistent with the "Common Image Format" (CIF). It features an active image area of 1928 horizontal by 1084 vertical pixels and has a 55% fill factor. The camera is designed to operate in continuous mode with an output data rate of 5MHz, which gives a maximum frame rate of 4 frames per second. The MIT/Polaroid group developed two cameras under this program. The cameras have effectively four times the current video spatial resolution and at 60 frames per second are double the normal video frame rate.

Hunt, William D.↗

Solid-state Image Sensor with Focal-plane Digital Photon-counting Pixel Array

A solid-state focal-plane imaging system comprises an NxN array of high gain. low-noise unit cells. each unit cell being connected to a different one of photovoltaic detector diodes, one for each unit cell, interspersed in the array for ultra low level image detection and a plurality of digital counters coupled to the outputs of the unit cell by a multiplexer(either a separate counter for each unit cell or a row of N of counters time shared with N rows of digital counters). Each unit cell includes two self-biasing cascode amplifiers in cascade for a high charge-to-voltage conversion gain (greater than 1mV/e(-)) and an electronic switch to reset input capacitance to a reference potential in order to be able to discriminate detection of an incident photon by the photoelectron (e(-))generated in the detector diode at the input of the first cascode amplifier in order to count incident photons individually in a digital counter connected to the output of the second cascade amplifier. Reseting the input capacitance and initiating self-biasing of the amplifiers occurs every clock cycle of an integratng period to enable ultralow light level image detection by the may of photovoltaic detector diodes under such ultralow light level conditions that the photon flux will statistically provide only a single photon at a time incident on anyone detector diode during any clock cycle.

Fossum, Eric R.↗

CLAES focal plane array

The Cryogenic Limb Array Etalon Spectrometer for the NASA Upper Atmospheric Research Satellite uses solid-state focal plane arrays to detect emission from the earth's atmosphere over the IR wavelength range 3.5 to 13 microns. This paper discusses the design of the focal plane detector assembly and compares calculated performance with measurements. Measurements were made of focal plane noise and responsivity as functions of frequency (2 to 500 Hz) and temperature (12 to 19 K), pixel-to-pixel and across-array crosstalk, and linearity over a dynamic range of 100,000. The measurements demonstrate that the arrays satisfy the science requirements, and that, in general, there is reasonable agreement between the measurements and the analytical model.

Roche, A. E.↗

Advanced far infrared blocked impurity band detectors based on germanium liquid phase epitaxy

This research has shown that epilayers with residual impurity concentrations of 5 x 10(sup 13) cm(exp -3) can be grown by producing the purest Pb available in the world. These epilayers have extremely low minority acceptor concentrations, which is ideal for fabrication of IR absorbing layers. The Pb LPE growth of Ge also has the advantageous property of gettering Cu from the epilayer and the substrate. Epilayers have been grown with intentional Sb doping for IR absorption on lightly doped substrates. This research has proven that properly working Ge BIB detectors can be fabricated from the liquid phase as long as pure enough solvents are available. The detectors have responded at reach minimum wavenumbers. Optimization of the Sb doping concentration should further decrease the photoionization energy of these detectors. Ge BIB detectors have been fabricated that respond to 60 cm(exp -1) with low responsivity. Through reduction of the minority residual impurities, detector performance has reached responsivities of 1 A/W. These detectors have exhibited quantum efficiency and NEP values that rival conventional photoconductors and are expected to provide a much more sensitive tool for new scientific discoveries in a number of fields, including solid state studies, astronomy, and cosmology.

Olsen, C. S.↗

The Lockheed diode array magnetograph

A new magnetograph using a solid state monolithic linear silicon diode array has been constructed at Lockheed Solar Observatory. This magnetograph uses a digital image processor, and makes data available both in digital and analog form. The diode array detector is capable of a signal-to-noise ratio of 2000:1 or better when cooled to a temperature of -40 deg centigrade. Thus, intensity differences of the order of one part in a thousand may easily be detected without signal averaging. This instrument may be considered a prototype for an instrument using a two-dimensional array. The magnetograph is now fully operational, and is being used to produce data for statistical studies of solar magnetic field diffusion.

Smithson, R. C.↗

Extraction of quadrature phase information from multiple pulse NMR signals

A multiple pulse sequence (8-pulse sequence) used for high-resolution solid state NMR is analyzed with regard to the information available from each of the four wide sampling windows. It is demonstrated that full quadrature phase information can be obtained using only a single phase detector and that, for the commonly encountered situation where the spectral width is much less than the folding frequency, the signals from the various windows can be combined easily using standard complex Fourier transform software. An improvement in the signal-to-noise ratio equal to the square root of 3 is obtained over either standard single or quadrature phase detection schemes. Procedures for correcting spectral distortions are presented.

Rhim, W.-K.↗

Optical Detection of Lightning from Space

Two primary detection techniques (optical and RF) have a proven capability for detecting lightning from low earth orbit. However, the lightning processes that generate the optical and RF signals are vastly different providing significantly different information content from each sensor type. Because of the intervening ionosphere, low frequency RF components do not reach satellite altitudes. As a consequence, many of the processes associated with the major energy release of a lightning event (i.e. return strokes, k-changes, recoil streamers, etc), in all likelihood contribute little to the RF signal arriving at the satellite. The optical output from lighting, on the other hand, has been shown to be highly correlated with the energetic, charge-transferring processes mentioned above. On the down side, the optical energy, while essentially unaffected by the atmosphere once it emerges from the cloud, is heavily scattered within the cloud. While there is little absorption by the cloud, the great optical depth makes the total light energy emerging from the cloud to be dependent on where in the cloud the lightning occurred. Analyses suggest that when lightning is confined to the lowest regions of the cloud, the light is strongly attenuated and detection becomes problematic. Fortunately, the vast majority of lightning flashes are comprised of channels that propagate through the middle of the cloud and higher. These flashes produce bright signals at the top of a cloud and are readily detectable. Presently, we have two optical instruments in orbit. The Optical Transient Detector (OTD) has been orbiting the earth since April, 1995, while the Lightning Imaging Sensor (LIS) was launched on the Tropical Rainfall Measuring Mission (TRMM) in November of 1997. Both instruments are relatively small, solid state optical imagers, designed specifically to detect and locate lightning activity from low earth orbit with high detection efficiency and location accuracy.

Christian, H. J.↗

Microaltimeter

A microaltimeter measures altitude or range highly accurately from an orbiting vehicle. The microaltimeter has a low power solid state laser that is pulsed at a rate above 1 kilohertz. The pulses are delivered to a small telescope which sends them to a planetary surface and receives return reflections. A high efficiency photon detector measures received photons and supplies received photon signals to a process or which makes a time-based bin-wise comparison to find the time of flight and hence the range.

Degnan, John J↗

Nd:YAG and ruby based lidar systems for remote sensing of atmospheric aerosols

The application of solid-state lasers to the study of stratospheric and tropospheric aerosols is analyzed. A 48-inch mobile lidar which operates in the 0.6943, 1.06, 0.3472, and 0.5300 micron ranges is utilized to monitor the stratosphere. The detectors of the system consist of photomultipliers, and the dual-channel, computer-based data-acquisition-system which provides on-line plotting of scattering ratio profiles. The components of the 14-inch aperture, dual-wavelength airborne lidar system that operates with ruby and Nd:YAG transmitters are described. An 8-inch, down-looking airborne lidar with silicon diode or photomultiplier detectors was developed. The capabilities of the system alone and when combined with the 14-inch lidar are discussed. Examples of the data provided by the three lidar systems are presented, revealing the reliability and operational efficiency of the systems.

Fuller, W. H., Jr.↗

Comparison of 2 micron Ho and 10 micron CO2 lidar for atmospheric backscatter and Doppler windshear detection

The development of eye-safe, solid-state Lidar systems is discussed, with an emphasis on Coherent Doppler Lidar for Atmospheric Wind Measurements. The following subject areas are covered: tunable Ho DIAL (Differential Absorption Lidar)/lidar atmospheric measurements; atmospheric turbulence measurements and detector arrays; diurnal measurements of C(sub n)(sup 2) for KSC lidar measurements; and development of single-frequency Ho laser/lidar.

Killinger, Dennis↗

Some aspects of optical feedback with cadmium sulfide and related photoconductors

A primary limitation of many solid state photoconductors used in electro-optical systems is their slow response in converting varying light intensities into electrical signals. An optical feedback technique is presented which can extend the frequency response of systems that use these detectors by orders of magnitude without adversely affecting overall signal-to-noise ratio performance. The technique is analyzed to predict the improvement possible and a system is implemented using cadmium sulfide to demonstrate the effectiveness of the technique and the validity of the analysis.

Katzberg, S. J.↗

Breadboard linear array scan imager using LSI solid-state technology

The performance of large scale integration photodiode arrays in a linear array scan (pushbroom) breadboard was evaluated for application to multispectral remote sensing of the earth's resources. The technical approach, implementation, and test results of the program are described. Several self scanned linear array visible photodetector focal plane arrays were fabricated and evaluated in an optical bench configuration. A 1728-detector array operating in four bands (0.5 - 1.1 micrometer) was evaluated for noise, spectral response, dynamic range, crosstalk, MTF, noise equivalent irradiance, linearity, and image quality. Other results include image artifact data, temporal characteristics, radiometric accuracy, calibration experience, chip alignment, and array fabrication experience. Special studies and experimentation were included in long array fabrication and real-time image processing for low-cost ground stations, including the use of computer image processing. High quality images were produced and all objectives of the program were attained.

Tracy, R. A.↗

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

Charge-coupled device camera for the Galileo Jupiter Orbiter spacecraft

A slow-scan television camera called the solid-state imaging subsystem (SSI), built for the Galileo Jupiter Orbiter, is described. The SSI consists of a 1500-mm focal-length telescope coupled to a camera head housing a 800 x 800-element charge-coupled device (CCD) detector based on 'virtual-phase' charge transfer technology. The CCD detector provides broadband sensitivity over 100 times that of a comparable vidicon-tube camera, while also yielding improved resolution, linearity, geometric fidelity, and spectral range. The system noise floor is 30 electrons, which results in a dynamic range of about 3500. Saturation of the detector with 9000-A light, followed by a high-speed erasure cycle prior to exposing each image, stabilizes the detector quantum efficiency at its maximum level for wavelengths beyond 7000 A. An optical schematic diagram of the SSI is included.

Klaasen, K. P.↗

PRIMA: The PRobe Far-Infrared Mission for Astrophysics

PRIMA is a far-infrared observatory concept being developed to address timely and fundamental questions about the growths of galaxies and solar systems and their constituents. It will observe the build-up of heavy elements, dust, stars, and black holes in galaxies and their interrelationships, and trace the masses and water contents of protoplanetary disks to probe the growths of solar systems. The majority of observing time will be devoted to Guest Observer programs to enable the astrophysics community to identify and plan the most critical observations, with focused PI programs to address key science with rapid releases of data to inform community planning. PRIMA will have spectral, hyperspectral imaging, and polarimetric capabilities, enabled now for the first time by extraordinary progress in kinetic inductance detector (KID) array technology over the last two decades. The 2.0-meter telescope will be cooled to < 5 K to take maximum advantage of the KID sensitivities. For observations of atomic fine-structure lines, molecular lines, and solid-state emission and absorption bands, R = 200 spectral coverage will range from approximately 25 µm to 200 µm, with a high-resolution mode across the entire band that will have a spectral resolving power of a few thousand at 100 µm. R ~ 10 moderate-resolution (hyperspectral) imaging will range from 25 to 80 µm for rest-frame, mid- and far-infrared spectral energy distribution measurements to probe dust grain composition and disambiguate star formation and active galactic nuclei in galaxies. Polarimetric observations of large areas of Galactic molecular clouds and the Magellanic Clouds from 80 to ~200 µm will bridge between the large-scale polarimetry of the interstellar medium from cosmic microwave background observatories and protostellar disk-scale interferometric observations to probe magnetic fields at the critical scales at which clouds collapse to form stars. An overview of PRIMA’s basic design and capabilities will be presented. Other posters in this session describe PRIMA science, technology, and instrumentation in greater depth.

Jason Glenn↗

A Technique for Increasing the Sensitivity of a Solid-State Fission Probe

A small silicon p-n junction wafer, when coated with uranium 235, can be used as a compact fission probe for low power flux and power mapping. Because of the inverse relation between the magnitude of a neutron-induced fission pulse and the inherent capacitance of the detecting element (capacitance is proportional to area), the size, and hence the sensitivity, of the semiconductor detector has been limited. New developments in the field of semiconductor detectors have made it possible to fabricate large area detectors which are essentially free from the capacitance effect. However, preliminary results indicate that they are much more susceptible to radiation damage than the detectors described in this report and as such may not be suitable for flux mapping. increasing the sensitivity cannot be accomplished by simply fabricating a larger detector. It has been observed that by combining the silicon p-n junction wafers in a series configuration the capacitance effect can be bypassed, and a fission probe can be made with a resultant increase in sensitivity by a factor of ten while sustaining only a minor decrease in pulse height. Analysis further indicates that for n silicon wafers in series, if n(C(sub i)) + C(sub c)/C(sub b) less than 0.1 where C(sub i) and C(sub c) are the preamplifier input and cable capacitances, respectively, and C(sub b) is the junction capacitance of a single silicon wafer, there should be no substantial reduction in pulse height due to series circuitry.

Steinberg, Robert↗