Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source code (Computer science)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Effects of breast-air and breast-lung interfaces on the dose rate at the planning target volume of a MammoSite catheter for Yb-169 and Ir-192 HDR sources

Purpose: To study the effects of the breast-air and breast-lung interfaces on the absorbed dose within the planning target volume (PTV) of a MammoSite balloon dose delivery system as well as the effect of contrast material on the dose rate in the PTV. Methods: The Monte Carlo MCNP5 code was used to simulate dose rate in the PTV of a 2 cm radius MammoSite balloon dose delivery system. The simulations were carried out using an average female chest phantom (AFCP) and a semi-infinite water phantom for both Yb-169 and Ir-192 high dose rate sources for brachytherapy application. Gastrografin was introduced at varying concentrations to study the effect of contrast material on the dose rate in the PTV. Results: The effect of the density of the materials surrounding the MammoSite balloon containing 0% contrast material on the calculated dose rate at different radial distances in the PTV was demonstrated. Within the PTV, the ratio of the calculated dose rate for the AFCP and the semi-infinite water phantom for the point closest to the breast-air interface (90 deg.) is less than that for the point closest to the breast-lung interface (270 deg.) by 11.4% and 4% for the HDR sources of Yb-169 and Ir-192, respectively. When contrast material was introduced into the 2 cm radius MammoSite balloon at varying concentrations, (5%, 10%, 15%, and 20%), the dose rate in the AFCP at 3.0 cm radial distance at 90 deg. was decreased by as much as 14.8% and 6.2% for Yb-169 and Ir-192, respectively, when compared to that of the semi-infinite water phantom with contrast concentrations of 5%, 10%, 15%, and 20%, respectively. Conclusions: Commercially available software used to calculate dose rate in the PTV of a MammoSite balloon needs to account for patient anatomy and density of surrounding materials in the dosimetry analyses in order to avoid patient underdose.

60 APPLIED LIFE SCIENCES↗

A Comparison of GPU-Accelerated Multiphase CFD Solvers on the Polaris Supercomputer: Part 1

This report is in support of the Innovative and Novel Computational Impact on Theory and Experiment (INCITE) program sponsored by the U.S. Department of Energy (USDOE). With INCITE-level resources, one project, titled BubblyFlow, was granted computational resources for the 2025 calendar year on the Polaris supercomputer at the Argonne Leadership Computing Facility (ALCF). The project aims to conduct simulations to understand the fundamental characteristics of turbulent bubbly flow phenomena in nature. Staff at the ALCF and Argonne’s Computational Science division, along with collaborators at the City College of New York and University of Illinois at Chicago, helped a summer student to assess the accuracy and performance of two high performance computing (HPC) codes. Both codes, ImExLBM and FluTAS, are fundamentally different in their mathematical and numerical modeling. However, both may be used to solve the same physical problem. The collaboration sought to better understand the differences between both codes in terms of accuracy and efficiency. This would ultimately help the BubblyFlow project better utilize resources and establish a knowledge-base of code capabilities in future simulation campaigns. We compare ImExLBM and FluTAS, two high-performance multiphase computational fluid dynamics (CFD) solvers, in terms of physical fidelity, time-to-solution, and parallel efficiency. We validate ImExLBM (Implicit-Explicit Lattice Boltzmann Method) against a canonical benchmark and assess it’s performance relative to FluTAS (Fluid Transport Accelerated Solver), a well-established open-source CFD code.

97 MATHEMATICS AND COMPUTING↗

An investigation of aluminum titanate-spinel composites behavior in radiation

In the present work, the radiation attenuation properties of Aluminum titanate (Al{sub 2}TiO{sub 5})-Spinel (MgAl{sub 2}O{sub 4}) ceramics composites were investigated. Al{sub 2}TiO{sub 5}-MgAl{sub 2}O{sub 4} ceramics composites which have different Al{sub 2}TiO{sub 5} percentages (0%, 5% and 10%) were produced and performed against gamma sources. Cs-137 and Co-60 were used as gamma radiation sources. Transmission technique was used in the experiments. The linear and mass attenuation coefficients of the samples were carried out for gamma radiation sources. The experimental results were compared with the theoretical mass attenuation coefficients which were calculated by using XCOM computer code. Increasing Al{sub 2}TiO{sub 5} percentage in the Aluminum titanate/ Spinel ceramics composites causes the higher linear and mass attenuation coefficients of the composites against Cs-137 and Co-60 gamma radioisotopes. Therefore Also theoretical mass attenuation coefficients are compatible with the experimental results. In conclusion, increasing the Aluminum titanate ratio in the Al{sub 2}TiO{sub 5}-MgAl{sub 2}O{sub 4} ceramics composites increases the gamma shielding property of the Al{sub 2}TiO{sub 5}-MgAl{sub 2}O{sub 4} ceramics for nuclear shielding applications.

36 MATERIALS SCIENCE↗

Continued Validation Studies using the MOOSE Framework for Plasma Simulation with Electromagnetics

Resources and tools for the modeling and simulation of low-temperature plasma (LTP) discharges are increasingly vital to progress in the field in order to properly characterize and study complex source designs and plasma chemistries beyond the scope of traditional diagnostics. Open-source software provides powerful platforms for this work and can enable community-driven LTP R&D. Within the Multiphysics Object-Oriented Simulation Environment (MOOSE) open-source framework [1], capabilities have been demonstrated in the areas of plasma fluids (Zapdos [2]), plasma chemistry (CRANE [3]), and general electromagnetic wave theory (Electromagnetic Library for Kinetics & fluids [ELK] [4]). ELK has since been coupled to Zapdos/CRANE to enable fully coupled electromagnetic plasma simulations. This talk will detail the continued validation efforts and discuss Zapdos-ELK-CRANE code coupling with various-low temperature plasma sources. The impact of fully coupled electromagnetics on process parameters (e.g., temperature and electron/ion energy) versus an electrostatic description will also be discussed. [1] Permann et al., SoftwareX, 11 (2020) 100430. [2] Lindsay et al., J. Phys. D: Appl. Phys. 49 (2016) 235204. [3] Keniley et al., Talk, GEC Session DT3.00002 (2019). [4] Icenhour et al., Talk, GEC Session RR1.00006 (2019). Acknowledgements: INL Graduate Fellowship Program, NSF SI2 Grant 1740300, U.S. Dept. of Energy Office of Science Graduate Student Research Program

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

Nonlinear Optimization in "Synchrotron Radiation Workshop" Code

"Synchrotron Radiation Workshop" (SRW) is an open source physical optics computer code for calculation of detailed characteristics of Synchrotron Radiation (SR) generated by relativistic electrons in magnetic fields of arbitrary configuration. SRW also supports high-accuracy simulations of fully- and partially-coherent radiation propagation through X-ray optical beamlines, facilitated by so-called “Virtual Beamline” module. In this present tech note, we discuss the nonlinear optimization features of SRW with emphasis on the optimization library in SRW. This optimization library not only can be used to optimize the simulation beamline in SRW, it also can be integrated with real beamline operations and optimize the parameters based on real measurements. We also show some demos of the optimization library recently developed in SRW.

36 MATERIALS SCIENCE↗

Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions

Purpose: MatriXX is a two-dimensional ion chamber array designed for IMRT/VMAT (RapidArc, IMAT, etc.) dose verifications. Its dosimetric properties have been characterized for megavoltage beams in a number of studies; however, to the best of the authors' knowledge, there is still a lack of an investigation into its performance in the peripheral or low dose regions. In this work, the authors have carried out a systematic study on this issue. Methods: The authors compare the performance of MatriXX with a cylindrical ion chamber in solid water phantoms in the peripheral dose regions. The comparisons are performed for a number of typical irradiation conditions that involve different gantry and/or MLC motions, field sizes, and distances to the target including static gantry/open fields, static gantry/sweeping MLC gap (mimicking an IMRT delivery), dynamic gantry/oscillating sweeping MLC gap (mimicking a VMAT delivery), as well as clinical IMRT and VMAT plans. Results: MatriXX, when used according to the manufacturer's recommendations, is found to disagree with an ion chamber in peripheral dose regions. This disagreement has been attributed to four types of MatriXX errors, namely, positive bias, over-response to scattered doses, round-off error, and angular dependence, all of which contribute to dose inaccuracies in the peripheral regions. The positive bias, which is independent of the dose level, is cumulative when MatriXX operates in the movie mode. The accumulation is proportional to the number of movie frames (snaps) when the sampling time is greater than 500 ms and is proportional to the overall movie time for a sampling time shorter than 500 ms. This behavior suggests multiple sources of the bias. MatriXX is also found to over-respond to peripheral doses by about 2.0% for the regions investigated in this work (3-15 cm from the field edge), where phantom scatter and collimator scatter dominate. Round-off error is determined to be due to insufficient precision in conversion of the raw signals to MatriXX software data for low doses. Angular dependence is defined as the dose response of MatriXX at different gantry angles. Up to 8% difference in detector response has been observed between 0 deg. and 180 deg. Possible sources of these errors are discussed and a correction method is suggested. With corrections, MatriXX shows good agreement with the ion chamber in all cases involving different gantry and/or MLC dynamics, as well as the clinical plans. For both primary and peripheral doses, MatriXX shows dose linearity down to 2 cGy with an accuracy of within 1% of the local dose. Conclusions: The performance of MatriXX has been systematically evaluated in the peripheral dose regions. Major sources of error associated with MatriXX are identified and a correction method is suggested. This method has been successfully tested using both experimental and clinical plans. In all cases, good agreements between MatriXX and an ion chamber are achieved after corrections. The authors conclude that with proper corrections, MatriXX can be reliably used for peripheral dose measurements within the ranges studied.

60 APPLIED LIFE SCIENCES↗

Methodology and Determination of Field of View of Neutron and Gamma Detectors in the Atucha Spent Fuel Storage Pool

In this paper we seek to create a model by determining the field of view (FOV) of a detector (i.e. which assemblies contribute to the detector response) in the Atucha-I spent fuel pool. The FOV is determined by solving the adjoint transport equation using the 3-D, parallel PENTRAN (Parallel Environment Neutral-particle TRANsport) Sn code, with the detector cross section as the adjoint source. If this adjoint function is coupled with the source spectrum, then the contribution to the detector from each assembly can be determined. First, the reactor criticality was modeled using the MCNP5 (Monte Carlo N-Particle) Monte Carlo code in order to determine the power distribution in each assembly. Using the power distribution data, the assemblies were divided and homogenized into 8 axial and 3 radial zones for burnup analysis. Depletion calculations were performed for each zone using the ORIGEN-ARP (Automatic Rapid Processing) utility from the SCALE 5.1 (Standardized Computer Analyses for Licensing Evaluation) code package. Spent fuel pool and detector were modeled in 2-D in PENTRAN as the detector plus 3 fuel assemblies along both x and y axes. Using the resulting adjoint function combined with the source spectrum, they have determined the FOVs of the fission chamber neutron detector that was used at Atucha, and concluded that 2 assemblies along x and y axes are needed for both cases (i.e. the 4 adjacent assemblies plus the next surrounding 12). For the neutron detector, 88% of the response comes from the nearest 4 assemblies, with 99% from the nearest 16. Results for a uniformly sensitive gamma detector indicate that 2 assemblies in both directions are also needed, with 89% of the response coming from the adjacent assemblies. A Monte Carlo calculation using MCNP was performed to benchmark the neutron result, giving a similar result (87% MCNP vs. 88% PENTRAN). Based on these studies, we have developed a database of FOVs as a function of burnup and decay conditions for different detector types, and a methodology/algorithm which uses this database to analyze the response of a detector placed in a spent fuel pool with the aim of detecting gross defects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A SQL to C compiler in 500 lines of code

Abstract We present the design and implementation of a SQL query processor that outperforms existing database systems and is written in just about 500 lines of Scala code – a convincing case study that high-level functional programming can handily beat C for systems-level programming where the last drop of performance matters. The key enabler is a shift in perspective toward generative programming. The core of the query engine is an interpreter for relational-algebra operations, written in Scala. Using the open-source lightweight modular staging framework, we turn this interpreter into a query compiler with very low effort. To do so, we capitalize on an old and widely known result from partial evaluation: the first Futamura projection, which states that a process that can specialize an interpreter to any given input program is equivalent to a compiler. In this context, we discuss lightweight modular staging programming patterns such as mixed-stage data structures (e.g., data records with static schema and dynamic field components) and techniques to generate low-level C code, including specialized data structures and data loading primitives.

Computer Science↗

Toward large-scale simulation of residual stress and distortion in wire and arc additive manufacturing

In this study, we aim to advance the structural analysis of wire and arc additive manufacturing (WAAM) by considering the thermomechanical features inherent in direct energy deposition. Simulation approaches including the iterative substructure method (ISM), dynamic mesh refining method (DMRM), and graphics processing unit (GPU) based explicit finite element method (FEM) were developed for accelerating additive manufacturing stress analysis that is very time consuming by conventional numerical methods. ISM and DMRM take advantage of the strong nonlinearity phenomenon near the moving heat source by reducing the global iterations and refining the local mesh, respectively. In addition to the use of GPUs, the explicit FEM is accelerated by a time scaling technique based on the inherent strain concept. The residual stress and distortion of two large builds were analyzed, showing very consistent numerical results and good agreement with experiments. Compared with the commercial software Abaqus, the novel approaches reduced the computational cost substantially without compromising accuracy. The GPU code showed the highest computational efficiency (30~70×), while DMRM and ISM had acceleration factors of 9× and 3×, respectively. Finally, such high-fidelity modeling approaches will be very useful for building up a digital twin of WAAM to reduce development time and cost.

36 MATERIALS SCIENCE↗

BLOC Site - ASSIST Thermodynamic Retrievals TROPoe v0.18 / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). This is a post-processed dataset and recommended for use. The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Michaud-Belleau et al. 2025) operated by NOAA Physical Sciences Laboratory (PSL) on Block Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a collocated surface tower operated by NOAA PSL. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY. The TROPoe docker container (version 0.18) is available from Docker Hub at https://hub.docker.com/r/davidturner53/tropoe/tags, and the source code code is available in the GitHub repository https://github.com/OAR-atmospheric-observations/TROPoe.

17 WIND ENERGY↗

NANT Site - ASSIST Thermodynamic Retrievals TROPoe v0.18 / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). This is a post-processed dataset and recommended for use. The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Michaud-Belleau et al. 2025) operated by NOAA Physical Sciences Laboratory (PSL) on Nantucket Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a collocated surface tower operated by NOAA PSL. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY. The TROPoe docker container (version 0.18) is available from Docker Hub at https://hub.docker.com/r/davidturner53/tropoe/tags, and the source code code is available in the GitHub repository https://github.com/OAR-atmospheric-observations/TROPoe.

17 WIND ENERGY↗

GlycReSoft: A Software Package for Automated Recognition of Glycans from LC/MS Data

Glycosylation modifies the physicochemical properties and protein binding functions of glycoconjugates. These modifications are biosynthesized in the endoplasmic reticulum and Golgi apparatus by a series of enzymatic transformations that are under complex control. As a result, mature glycans on a given site are heterogeneous mixtures of glycoforms. This gives rise to a spectrum of adhesive properties that strongly influences interactions with binding partners and resultant biological effects. In order to understand the roles glycosylation plays in normal and disease processes, efficient structural analysis tools are necessary. In the field of glycomics, liquid chromatography/mass spectrometry (LC/MS) is used to profile the glycans present in a given sample. This technology enables comparison of glycan compositions and abundances among different biological samples, i.e. normal versus disease, normal versus mutant, etc. Manual analysis of the glycan profiling LC/MS data is extremely time-consuming and efficient software tools are needed to eliminate this bottleneck. In this work, we have developed a tool to computationally model LC/MS data to enable efficient profiling of glycans. Using LC/MS data deconvoluted by Decon2LS/DeconTools, we built a list of unique neutral masses corresponding to candidate glycan compositions summarized over their various charge states, adducts and range of elution times. Our work aims to provide confident identification of true compounds in complex data sets that are not amenable to manual interpretation. This capability is an essential part of glycomics work flows. We demonstrate this tool, GlycReSoft, using an LC/MS dataset on tissue derived heparan sulfate oligosaccharides. The software, code and a test data set are publically archived under an open source license.

Environmental Molecular Sciences Laboratory↗

Common workflows for computing material properties using different quantum engines

The prediction of material properties based on density-functional theory has become routinely common, thanks, in part, to the steady increase in the number and robustness of available simulation packages. This plurality of codes and methods is both a boon and a burden. While providing great opportunities for cross-verification, these packages adopt different methods, algorithms, and paradigms, making it challenging to choose, master, and efficiently use them. We demonstrate how developing common interfaces for workflows that automatically compute material properties greatly simplifies interoperability and cross-verification. We introduce design rules for reusable, code-agnostic, workflow interfaces to compute well-defined material properties, which we implement for eleven quantum engines and use to compute various material properties. Each implementation encodes carefully selected simulation parameters and workflow logic, making the implementer’s expertise of the quantum engine directly available to non-experts. All workflows are made available as open-source and full reproducibility of the workflows is guaranteed through the use of the AiiDA infrastructure.

36 MATERIALS SCIENCE↗

MAPPRAISER: A massively parallel map-making framework for multi-kilo pixel CMB experiments

Forthcoming cosmic microwave background (CMB) polarized anisotropy experiments have the potential to revolutionize our understanding of the Universe and fundamental physics. The sought-after, tale-telling signatures will be however distributed over voluminous data sets which these experiments will collect. These data sets will need to be efficiently processed and unwanted contributions due to astrophysical, environmental, and instrumental effects characterized and efficiently mitigated in order to uncover the signatures. This poses a significant challenge to data analysis methods, techniques, and software tools which will not only have to be able to cope with huge volumes of data but to do so with unprecedented precision driven by the demanding science goals posed for the new experiments. A keystone of efficient CMB data analysis is solvers of very large linear systems of equations. Such systems appear in very diverse contexts throughout CMB data analysis pipelines, however they typically display similar algebraic structures and can therefore be solved using similar numerical techniques. Linear systems arising in the so-called map-making problem are one of the most prominent and common ones. In this work we present a massively parallel, flexible and extensible framework, comprised of a numerical library, MIDAPACK, and a high level code, MAPPRAISER, which provide tools for solving efficiently such systems. Here, the framework implements iterative solvers based on conjugate gradient techniques: enlarged and preconditioned using different preconditioners. We demonstrate the framework on simulated examples reflecting basic characteristics of the forthcoming data sets issued by ground-based and satellite-borne instruments, executing it on as many as 16,384 compute cores. The software is developed as an open source project freely available to the community at: https://github.com/B3Dcmb/midapack.

79 ASTRONOMY AND ASTROPHYSICS↗

Computing water flow through complex landscapes – Part 3: Fill–Spill–Merge: flow routing in depression hierarchies

Abstract. Depressions – inwardly draining regions – are common to many landscapes. When there is sufficient moisture, depressions take the form of lakes and wetlands; otherwise, they may be dry. Hydrological flow models used in geomorphology, hydrology, planetary science, soil and water conservation, and other fields often eliminate depressions through filling or breaching; however, this can produce unrealistic results. Models that retain depressions, on the other hand, are often undesirably expensive to run. In previous work we began to address this by developing a depression hierarchy data structure to capture the full topographic complexity of depressions in a region. Here, we extend this work by presenting the Fill–Spill–Merge algorithm that utilizes our depression hierarchy data structure to rapidly process and distribute runoff. Runoff fills depressions, which then overflow and spill into their neighbors. If both a depression and its neighbor fill, they merge. We provide a detailed explanation of the algorithm and results from two sample study areas. In these case studies, the algorithm runs 90–2600 times faster (with a reduction in compute time of 2000–63 000 times) than the commonly used Jacobi iteration and produces a more accurate output. Complete, well-commented, open-source code with 97 % test coverage is available on GitHub and Zenodo.

58 GEOSCIENCES↗

A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system

Purpose: To develop a calibration phantom for {sup 192}Ir high dose rate (HDR) brachytherapy units that renders possible the direct measurement of absorbed dose to water and verification of treatment planning system.Methods: A phantom, herein designated BrachyPhantom, consists of a Solid Water™ 8-cm high cylinder with a diameter of 14 cm cavity in its axis that allows the positioning of an A1SL ionization chamber with its reference measuring point at the midheight of the cylinder's axis. Inside the BrachyPhantom, at a 3-cm radial distance from the chamber's reference measuring point, there is a circular channel connected to a cylindrical-guide cavity that allows the insertion of a 6-French flexible plastic catheter from the BrachyPhantom surface. The PENELOPE Monte Carlo code was used to calculate a factor, P{sub sw}{sup lw}, to correct the reading of the ionization chamber to a full scatter condition in liquid water. The verification of dose calculation of a HDR brachytherapy treatment planning system was performed by inserting a catheter with a dummy source in the phantom channel and scanning it with a CT. The CT scan was then transferred to the HDR computer program in which a multiple treatment plan was programmed to deliver a total dose of 150 cGy to the ionization chamber. The instrument reading was then converted to absorbed dose to water using the N{sub gas} formalism and the P{sub sw}{sup lw} factor. Likewise, the absorbed dose to water was calculated using the source strength, S{sub k}, values provided by 15 institutions visited in this work.Results: A value of 1.020 (0.09%, k= 2) was found for P{sub sw}{sup lw}. The expanded uncertainty in the absorbed dose assessed with the BrachyPhantom was found to be 2.12% (k= 1). To an associated S{sub k} of 27.8 cGy m{sup 2} h{sup −1}, the total irradiation time to deliver 150 cGy to the ionization chamber point of reference was 161.0 s. The deviation between the absorbed doses to water assessed with the BrachyPhantom and those calculated by the treatment plans and using the S{sub k} values did not exceed ±3% and ±1.6%, respectively.Conclusions: The BrachyPhantom may be conveniently used for quality assurance and/or verification of HDR planning system with a priori threshold level to spot problems of 2% and ±3%, respectively, and in the long run save time for the medical physicist.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and testing of a combined neutron and gamma assay system for measuring fissile material in fuel and waste items - 15340

A combined neutron and gamma ray assay system for the measurement of fissile material in both fuel and waste items has been designed, modelled, developed and tested. The purpose of the system is to measure and characterize a wide range of fissile materials including uranium, plutonium, americium and mixed oxide fuel arising from a variety of processes and facilities across the United Kingdom. Dounreay Site Restoration Limited at Dounreay currently stores these items form the United Kingdom Nuclear Decommissioning Authority's un-irradiated fuel inventory. This inventory comprises historic materials from ex-United Kingdom Atomic Energy Authority nuclear fuel projects and experiments together with fast reactor fuel materials and some commercial fuel items as delivered to Dounreay for recovery. The combined assay system has been designed and constructed to support the operation of a fuel processing facility, which will be operated at Dounreay to treat these historic legacy fuel materials, making them suitable for long term storage. Appropriate characterization of the fissile material is required for safety, criticality control and nuclear materials safeguards purposes prior to final disposition. The system consists of both gamma ray and neutron measurement components. The results of a neutron measurement are combined with the gamma ray isotopic ratio measurement results to generate the assay result for the fissile material being characterized. The gamma ray component of the system employs a safeguards quality high purity Germanium detector with electro-mechanical cooling and the measurements of fissile material containers are made in a shielded chamber with a tin and copper graded lining. Containers of fissile material are rotated during the gamma ray measurement and a variable automatic steel collimator aperture mechanism is employed to adjust the measured count rate to control detector dead time. Gamma ray spectra are analysed using the plutonium and uranium isotopic ratio code PC/FRAM. The gamma ray system can also be configured to perform a direct assay of small quantities of uranium bearing material. For this assay measurement a series of cadmium filters can be positioned in front of the detector to reduce the contribution from 59 keV gamma rays from Am-241. In addition to gamma ray isotopic measurements, both active and passive neutron assay is performed by the system. The neutron-measuring component consists of a thick walled cylindrical polyethylene chamber, which provides neutron moderation for 30 one-inch diameter He-3 detector tubes located in re-entrant channels in the polyethylene moderator. Two removable polyethylene-inserts incorporating lower plug assemblies are provided, one with and one without a cadmium lining. Also two top plug units are provided, again one with cadmium and one without a cadmium liner. The Neutron Subsystem can be operated both as a passive and as an active neutron coincidence counter. In both fast and thermal active neutron mode, the neutron component employs two americium-beryllium (Am-Be) alpha-n neutron sources, one positioned in the top and the other in the bottom plug unit. The neutron sources are removed when the counter is operated in passive mode. Passive neutron detection efficiency and active neutron performance has been modelled using the MCNP Monte Carlo computer simulation code as part of the design process. In the absence of fissile samples, operation of the gamma ray component of the system has been tested initially using calibrated Eu-152 and Ba-133 gamma ray sources and the use of archived spectra from fissile material measurements. Initial testing of the neutron system has employed a calibrated Cf-252 spontaneous fission neutron source. Neutron testing has been confirmed using further MCNP simulations. The results of test measurements with the system are presented and compared with the results of MCNP measurement simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗