Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Dose-Weighted Radiographic Source-Spot Size

The spatial resolution of a flash radiograph is determined by the time-integrated size of the radiation source. Since the radiation pulse includes the beam head and tail, which may be substantially larger than the beam body, the radiation source is larger than the focused flattop of the electron beam pulse. Moreover, the radiation dose rate is weighted by both beam current and electron energy, and it is the radiation dose that forms the radiograph image. Therefore, in order to estimate radiographic resolution from computer simulations of a focused electron beam, one should use a dose weighted moment analysis of the radiation source distribution. This approach is used to show that, in the absence of beam effects other than space-charge and emittance, radiographic resolution for Scorpius exceeds requirements, regardless of reasonable timing options for current and gap-voltage pulses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generalized wakefield of a microbunched electron cooler

In a previous note [1] we developed theoretical and computational tools for the study of microbunched electron cooling (MBEC [2]) in the three-dimensional regime. In this context, we were able to treat the key space charge effect in a rigorous fashion by taking explicitly into account the point-charge nature of the particles involved (electrons and hadrons). In this report, we build upon our earlier analysis by taking into consideration previously neglected effects that can cause Landau damping in the amplifier section (such as focusing, betatron oscillations and the angular spread of the electron beam). Beginning with the theoretical aspect of this work, we use our modified and expanded tools in order to calculate and study the generalized, point-hadron wakefield of the system, an important quantity that affects the cooling performance.

43 PARTICLE ACCELERATORS↗

Near-Infrared Noise in Intense Electron Beams

Requirements for the noise in electron beams (NEB) have recently approached the Shot-noise level in some new applications. The density fluctuations of intense beams in the near-infrared (NIR) region are being measured at the Fermilab Accelerator Science and Technology (FAST) facility. The main goal of the experiment is to accurately compare the Shot-noise model with the observations of optical transition radiation (OTR) generated by a relativistic electron beam ($\gamma \approx 63$), transiting an Aluminium metal surface. In addition, some evidence for longitudinal space-charge-induced microbunching for the chicane-compressed beam was obtained with coherent enhancements up to 100 in the various bandwidth-filtered NIR OTR photodiode signals. With micropulse charges up to 1 nC, the beam parameters are close to those proposed for a stage in an Electron-Ion Collider (EIC) with coherent electron cooling (CEC). In this paper we present the current progress of the NEB project and compare the low electron energy measurements with ImpactX simulations.

43 PARTICLE ACCELERATORS↗

Axially Symmetric E-Lens Based on McMillan Map

In this work, we investigate the transverse dynamics of a single particle in a model integrable accelerator lattice, based on a McMillan axially symmetric electron lens. Although the McMillan e-lens has been considered as a device potentially capable of mitigating collective space charge forces, some of its fundamental properties have not been described yet. The main goal of our work is to close this gap and understand the limitations and potential of this device. We classify possible regimes with stable trajectories and provide set of canonical action-angle variables, along with an evaluation of the dynamical aperture, Poincar\'e rotation numbers as functions of amplitudes, and spread in nonlinear tunes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of the New Beam Physics Research at the IOTA/FAST Facility

The Fermilab Accelerator Science and Technology (FAST) facility is dedicated to the exploration of novel concepts in accelerator and beam physics, and the development of a robust workforce, in order to enable and enhance next-generation particle accelerators. FAST comprises a high-brightness superconducting electron linac, and a storage ring, the Integrable Optics Test Accelerator (IOTA). Experiments in the most recent operational run include studies of nonlinear integrable lattices; tracking of single electrons; precise characterization of undulator radiation; studies with low-momentum-compaction lattices; and ultra-wide range beam diagnostics based on Photomultiplier tubes. In the linac, experiments on noise in intense electron bunches were conducted. The IOTA proton injector, currently being commissioned, will enable a diverse program on space-charge-dominated beams. Research areas include non-invasive beam profile monitoring for proton beams; beam dynamics with electron lenses; halo suppression, feedback systems, and electron cooling. In this presentation, we provide an overview of the recent results and highlight future plans together with opportunities for collaboration.

43 PARTICLE ACCELERATORS↗

Full Cycle Simulations of The Fermilab Booster

The Proton Improvement Plan phase II (PIP-II) project currently under construction at FNAL will replace the existing 400 MeV normal conducting linac with a new 800 MeV superconducting linac. The beam power in the downstream rapid-cycling Booster synchrotron will be doubled by raising the machine cycle frequency from 15 to 20 Hz and by increasing the injected beam intensity by a factor 1.5. This has to be accomplished without raising uncontrolled losses beyond the administrative limit of 500 W. In addition, slip-stacking efficiency in the Recycler, the next machine in the accelerator chain, sets an upper limit on the longitudinal emittance of the beam delivered by the Booster. As part of an effort to better understand potential losses and emittance blow-up in the Booster, we have been conducting full cycle 6D simulations using the code PyORBIT. The simulations include space charge, wall impedance effects and transition crossing. In this paper, we discuss our experience with the code and present representative results for possible operational scenarios.

43 PARTICLE ACCELERATORS↗

Demonstration of Temperature Compensation Techniques for SPNDs Operating in High Temperatures

This report presents the testing results of rhodium-based self-powered neutron detectors (Rh-SPND) irradiated in a furnace dry tube from ambient temperature to 850°C at the Ohio State University Research Reactor. The purpose of the experiment is to demonstrate the technique and application of a temperature compensation technique for the Rh-SPND. This is performed by characterizing the temperature effects observed in past experiments—a displacement current and a stabilized dark current—of the Rh-SPND as a function of temperature under the models of shifting space charges as a product of photoconductivity properties. Low-power irradiation at the OSURR was performed with stabilized temperatures of ambient, 550, 575, 600, 625, 650, 675, and 700°C were first performed to obtain the curve fit parameters that describes the temperature effects. The results provided further insight for the behavior of the SPND at high temperatures in accordance with available insulation conductivity models. Transition points from photoconductivity to ionic conductivity were identified in the range of 550–600°C. Additionally, transition points ionic to electric conductivity were observed in the range of 675–700°C, however, the data was not able to fully capture the transition and did not have enough resolution to provide predictive compensation based only on temperature readings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EIC hadron ring longitudinal stability simulations at injection

At the EIC injection energy (23.8 GeV for protons), the hadron beam experiences a relatively strong space charge field. The corresponding wakefield, in conjunction with the wakes from the RF cavities (i.e. the geometrical wakes), may become the cause of single-bunch instabilities, both longitudinal and transverse. In this report, we focus on the longitudinal stability aspect of this picture, using a simplified model for the ring.

43 PARTICLE ACCELERATORS↗

Accumulator Ring Design Energy and RCS-based Proton Driver

Traditional Fermilab proton upgrade scenarios include a "linac option" and an "RCS option". In the former case all the acceleration takes place in the linac into an accumulator ring, and in the latter case as much acceleration as possible takes place in the RCS. Whereas muon collider proton driver scenarios typically assume all linac acceleration, the possibility of an RCS option should be considered more closely. We walk through the technical risks and possible benefits injecting at a lower energy including space-charge, H- stripping, circumference, and linac design.

Eldred, Jeff [Fermilab]↗

The TRANFT User Manual version 2.0

The Fortran program TRANFT has undergone significant revision. While many of the original features remain others have been modified and new capabilities have been added. A second trans verse direction is now tracked so that the tune and force distributions associated with the beam beam force and nonlinear space charge are correct. Also, general mutibunch instabilites are now treated. For symmetric coupled bunch modes one can track one bunch for purely transverse modes or a few contiguous bunches to include longitudinal modes as well. Another option which tracks all the bunchs in the ring with provision for a clearing or abort gap is also available. In addition to this a new algorithm to model the transverse voltage on crab cavities is introduced which includes the effect of various feedbacks.

43 PARTICLE ACCELERATORS↗

Solenoidal Fields from Permanent Magnets for a Polarized Electron Preinjector

This technical note describes the design of a compact focusing solenoid constructed from permanent bar magnets, intended for the low-energy section of a spin-polarized electron injector. Typically, quadrupole triplets provide appropriate focusing for the low-energy spin rotator section; however, their large footprint precludes the insertion of sufficient beam diagnostics. The primary motivation of this study is to provide beam focusing while preserving the vertical spin orientation of the electron beam. We propose a solenoidal field composed of multiple permanent magnets arranged to naturally yield a zero longitudinal magnetic field integral ($\int B_zdz = 0$). This design serves as a compact, passive, and non-coupling alternative to traditional quadrupole triplets. We present the magnet arrangement, field calculation methodology, spin tracking simulations using space charge codes, and calculations demonstrating that the required field strength is achievable.

43 PARTICLE ACCELERATORS↗

Single-Bunch Instabilities at the Fermilab Recycler Ring

Understanding and characterizing collective instabilities is critical for high-intensity operation at the Fermilab Recycler Ring. This work presents an application of the the Nested Head-Tail (NHT) formalism for modeling single-bunch transverse instabilities, incorporating analytical solutions to the resistive wall impedances in the absence of space charge. Predicted growth rates and mode structures are benchmarked against PyHEADTAIL simulations and ongoing experimental measurements. The experimental program includes studies of bare-machine instabilities at different machine parameters. These results support the understanding of naturally-occurring instabilities in the Recycler and contribute to the development of predictive tools for beam stability in future high-intensity configurations.

Gonzalez-Ortiz, Cristhian [Fermilab]↗

SBND Calibration

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber (LArTPC) serving as the near detector of the Short-Baseline Neutrino Program at Fermilab. SBND aims to make precise measurements of neutrino-argon interactions, necessitating an extensive calibration program for the LArTPC to ensure precision/accuracy in these measurements. This talk describes the use of cosmogenic, radiogenic, and neutrino interaction activity with both Monte Carlo simulation and data in calibrating the SBND subsystems of the Time Projection Chamber, Photon Detection System, and Cosmic Ray Tagger. We will highlight some of SBND's first calibration results, including electronics calibrations, measurement of the electron lifetime, shower calibration, and studies of space charge effects in the detector.

Oh, Sungbin [Fermilab]↗

Digital Twin Framework for PIP-II Linac: AI-Driven Multi-Scale Modeling from Ion Source to 800 MeV

The PIP-II linac will enable >1.2 MW beam power for DUNE, requiring unprecedented operational reliability across its warm front-end (RFQ, MEBT) and five distinct SRF sections operating at 162.5/325/650 MHz. We present a comprehensive digital twin framework uniquely combining a fully differentiable fast beam transport code with neural network surrogates trained on high-fidelity PIC simulations, capturing space charge and nonlinear dynamics beyond traditional envelope codes while achieving 10⁴ speedup at <1% accuracy. End-to-end differentiability enables gradient-based optimization across 500+ parameters simultaneously previously impossible with conventional tools while the model incorporates static/dynamic errors and serves as a virtual commissioning platform for diverse hardware integration. The framework facilitates reinforcement learning for pulsed/CW mode transitions, predictive maintenance through anomaly detection, and autonomous tuning algorithm development with real-time execution capability. Validation against physics simulations shows excellent agreement for the front-end, with initial results demonstrating potential for 30% commissioning time reduction and proactive fault mitigation, providing a scalable blueprint for operating next-generation high-intensity accelerators.

Pathak, Abhishek [Fermilab] (ORCID:000000021704208↗

Measurement of the Emittance for the CeC Project

Coherent Electron Cooling (CeC) experiment was carried out at RHIC [1]. It required small emi ance of 10-15 MeV electron beam with high peak current. In most cases the emi ance was measured by either quadrupole or solenoid scan. For a low-energy beam with high peak current the measurements are affected by space charge forces. To overcome these difficul es the pepper-pot [2,3] or slit scan [4] can be used.

43 PARTICLE ACCELERATORS↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Calibration of calorimetric measurement in a liquid argon time projection chamber

The liquid argon time projection chamber provides high-resolution event images and excellent calorimetric resolution for studying neutrino physics and searching for beyond-standard-model physics. In this article, we review the main physics processes that affect detector response, including the electronics and field responses, space charge effects, electron attachment to impurities, diffusion, and recombination. We describe methods to measure those effects, which are used to calibrate the detector response and convert the measured raw analog-to-digital converter (ADC) counts into the original energy deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral Dependence of the Photoplastic Effect in CdZnTe and CdZnTeSe

We studied the spectral dependence of the Vickers microhardness HV0.025 of CdZnTe and CdZnTeSe samples upon illumination and found out that it increases over the entire applied spectral range of 1540–750 nm. We also found out that the photoconductivity and microhardness are correlated. We observed changes in the correlation diagram (change of slope and an abrupt change of HV0.025 at several wavelengths of the illuminating light). Based on measurements of the relative changes of the space charge upon illumination using the Pockels effect, we suggest that the observed spectral dependence of positive photoplastic effect in CdZnTe and CdZnTeSe can be explained by the trapping of photoinduced electrons and holes, which affects the motion of the partial dislocations. The underlying physical explanation relies on the assumption that reconstructed bonds break before dislocation glide.

36 MATERIALS SCIENCE↗