Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Design and implementation of a J -coupled spectrometer for multidimensional structure and relaxation detection at low magnetic fields

In recent years, it has been realized that low and ultra-low field (mT-nT magnetic field range) nuclear magnetic resonance (NMR) spectroscopy can be used for molecular structural analysis. However, spectra are often hindered by lengthy acquisition times or require large sample volumes and high concentrations. Here, we report a low field (50 µT) instrument that employs a linear actuator to shuttle samples between a 1 T prepolarization field and a solenoid detector in a laboratory setting. The current experimental setup is benchmarked using water and 13 C-methanol with a single scan detection limit of 2x10 20 spins (3 μL, 55 M H 2 O) and detection of 2.9x10 19 (200 μL, 617 mM 13 C-methanol) spins with signal averaging. The system has a dynamic range of >3 orders of magnitude. Investigations of room-temperature relaxation dynamics of 13Cmethanol show that sample dilution can be used in lieu of sample heating to acquire spectra with linewidths comparable to high-temperature spectra. These results indicate that the T 1 and T 2 mechanisms are governed by both the proton exchange rate and the dissolved oxygen in the sample. Finally, a 2D correlation spectroscopy (COSY) experiment is reported, performed in the strong coupling regime that resolves the multiple resonances associated with the heteronuclear Jcoupling. The spectrum was collected using 10 times less sample and in less than half the time from previous reports in the strong coupling limit.

47 OTHER INSTRUMENTATION↗

Interpolating individual line-of-sight neutron spectrometer measurements onto the “sky” at the National Ignition Facility (NIF)

Nuclear diagnostics provide measurements of inertial confinement fusion implosions used as metrics of performance for the shot. The interpretation of these measurements for shots with low mode asymmetries requires a way of combining the data to produce a “sky map” where the individual line-of-sight values are used to interpolate to other positions in the sky. These interpolations can provide information regarding the orientation of the low mode asymmetries. We describe the interpolation method, associated uncertainties, and correlations between different metrics, e.g., Tion, down scatter ratio, and hot-spot velocity direction. This work is also related to recently reported studies [H. G. Rinderknecht et al., Phys. Rev. Lett. 124, 145002 (2020) and K. M. Woo et al., Phys. Plasmas 27, 062702 (2020)] of low mode asymmetries. We report an analysis that makes use of a newly commissioned line of sight, a scheme for incorporating multiple neutron spectrum measurement types, and recent work on the sources of implosion asymmetry to provide a more complete picture of implosion performance.

Hartouni, E. P. (ORCID:0000000198694351)↗

A super-resolution technique to analyze single-crystal inelastic neutron scattering measurements using direct-geometry chopper spectrometers

Direct-geometry time-of-flight chopper neutron spectroscopy is instrumental in studying dynamics in liquid, powder, and single crystal systems. We report here that real-space techniques in optical imagery can be adapted to obtain reciprocal-space super resolution dispersion for phonon or magnetic excitations from single-crystal neutron spectroscopy measurements. The procedure to reconstruct super-resolution energy dispersion of excitations relies on an accurate determination of the momentum and energy-dependent point spread function and a dispersion correction technique inspired by an image disparity calculation technique commonly used in stereo imaging. Here by, applying these methods to spinwave dispersion data from a virtual neutron experiment demonstrates ~5-fold improvement over nominal energy resolution.

47 OTHER INSTRUMENTATION↗

EXPANSE: A time-of-flight EXPanded Angle Neutron Spin Echo spectrometer at the Second Target Station of the Spallation Neutron Source

EXPANSE, an EXPanded Angle Neutron Spin Echo instrument, has been proposed and selected as one of the first suite of instruments to be built at the Second Target Station of the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is designed to address scientific problems that involve high-energy resolution (neV– μeV) of dynamic processes in a wide range of materials. The wide-angle detector banks of EXPANSE provide coverage of nearly two orders of magnitude in scattering wavenumbers, and the wide wavelength band affords approximately four orders of magnitude in Fourier times. This instrument will offer unique capabilities that are not available in the currently existing neutron scattering instruments in the United States. Specifically, EXPANSE will enable direct measurements of slow dynamics in the time domain over wide Q-ranges simultaneously and will also enable time-resolved spectroscopic studies. The instrument is expected to contribute to a diverse range of science areas, including soft matter, polymers, biological materials, liquids and glasses, energy materials, unconventional magnets, and quantum materials.

47 OTHER INSTRUMENTATION↗

A flexible neutron spectrometer concept with a new ultra-high field steady-state vertical-bore magnet

The proposed facility explores materials under ultra-high magnetic fields. By combining the power of high fields to tune materials and of neutron scattering to probe the resulting changes down to the atomic scale, this facility will enable transformative progress in the study of quantum materials and is named for the “TITAN” subset of Greek gods to reflect this transformation. TITAN will offer DC magnetic fields up to at least 20 T. Exploiting the record brightness and bandwidth of the Second Target Station at the Spallation Neutron Source, TITAN will probe atomic-scale responses through high efficiency neutron spectroscopy up to 80 meV energy transfer, high resolution diffraction, and small angle neutron scattering. Focusing neutron optics will maximize flux on accurately positioned samples, while radial collimation and optimized shielding and detection strategies will minimize backgrounds.

47 OTHER INSTRUMENTATION↗

Preparation of a membrane-sealed cell for studying catalyst nanoparticles in flowing gas with high vacuum x-ray photoelectron spectrometer

Here a sealing-style x-ray photoelectron spectroscopy study of the surface of a 1.0 wt. %Ni/TiO2 nanoparticle catalyst in a flowing mixture of CO and O2 at 1 bar was performed with a graphene membrane-sealed Si3N4 window-based miniature cell. We report the details on how a commercial Si3N4 window is modified before assembling a graphene membrane, how single-layer graphene membranes are transferred from their metal supports to the modified Si3N4 window, how a modified Si3N4 window covered with a double-layer graphene membrane is assembled onto a blank cell cap, how a nanoparticle catalyst is introduced to the cell cap and then the cell cap is installed onto a cell body to form a complete reaction cell, and how a complete cell is interfaced with a high vacuum chamber of an XPS system before an XPS study of 1.0 wt. %Ni/TiO2 catalyst surface in a flowing mixture for 0.2 bar CO and 0.8 bar O2 is performed. How the characterization of a catalyst using this type of graphene membrane-sealed Si3N4 window-based miniature cell is relevant to the finding of the actual surface chemistry of a catalyst during catalysis is discussed.

Instruments & Instrumentation↗

Deep learning based x-ray spectrometer for high repetition rate characterization of betatron radiation

Betatron radiation produced from a laser-wakefield accelerator is a broadband, hard x-ray (>1 keV) source that has been used in a variety of applications in medicine, engineering, and fundamental science. Further development and optimization of stable, high repetition rate (HRR) (>1 Hz) betatron sources will provide a means to extend their application base to include single-shot dynamical measurements of ultrafast processes or dense materials. Recent advances in laser technology used in such experiments have enabled increases in shot-rate and system stability, providing improved statistical analysis and detailed parameter scans. However, unique challenges exist at high repetition rate, where data throughput and source optimization are now limited by diagnostic acquisition rates and analysis. Here, we present the development of a machine-learning algorithm for the real-time analysis of betatron radiation. We report on the fielding of this deep learning algorithm for online source characterization at the Institut National de la Recherche Scientifique's Advanced Laser Light Source. By fine-tuning an algorithm originally trained on a fully synthetic dataset using a subset of experimental data, the algorithm can predict the betatron critical energy with a percent error of 7.2 % with a reconstruction time of 1.5 ms, providing a valuable tool for real-time, multi-objective optimization at HRR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design of a Doppler spectrometer for 102 m/s cross-field flows in tokamak divertors

The cross-field transport in the scrape-off-layers (SOLs) and divertors in tokamaks is of a similar size to the poloidal component of the parallel flow, thereby significantly impacting the plasma transport there. However, its direct observation has been challenging because the drift velocity (102–103 m/s) is significantly below the detection limit of conventional diagnostics. To realize cross-field ion flow measurement, a variety of systematic uncertainties in the system must be narrowed down. Here, we develop a conceptual design of the Doppler spectrometry that enables us to measure the impurity flows with 102-m/s accuracy based on an in situ wavelength-calibration technique developed in the astrophysics field, the iodine-cell method. We discuss its properties and applicability. In particular, the scaling relation between wavelength accuracy and various spectroscopic parameters is newly presented, which suggests the high importance of the wavelength resolution of the system. Based on transport simulations for the JT-60SA divertor, the feasibility of the system is assessed.

Fujii, Keisuke↗

A compact x-ray spectrometer for measurements of electron temperature distributions in inertial confinement fusion implosions at OMEGA

The Wedge Range Filter (WRF), commonly used for proton spectroscopy at the OMEGA Laser Facility and National Ignition Facility, is adapted to measure the x-ray continuum spectrum through transmission measurement using a continuous-gradient filter. Continuum x rays emitted from the hotspot of an implosion contain information about the plasma composition and electron temperature. The WRF data are leveraged to probe this distribution, specifically the electron temperature distribution. In this work, the data recorded with the WRF are forward modeled using a temperature distribution model folded with the WRF response function. An uncertainty analysis is conducted through a Bayesian regression algorithm using a Hamiltonian Monte Carlo sampler. This analysis enables the uncertainties in the instrument response to be folded into the uncertainty estimation of the electron temperature and absolute x-ray emission. Data analysis for a series of OMEGA implosions is presented and compared with radiation hydrodynamic simulations.

Lasers↗