Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stack Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Total Cost of Ownership Model for Low Temperature PEM Fuel Cells in Combined Heat and Power and Backup Power Applications

A total cost of ownership model is described for low temperature proton exchange membrane stationary fuel cell systems for combined heat and power (CHP) applications from 1-250kW and backup power applications from 1-50kW. System designs and functional specifications for these two applications were developed across the range of system power levels. Bottom-up cost estimates were made for balance of plant costs, and detailed direct cost estimates for key fuel cell stack components were derived using design-for-manufacturing-and-assembly techniques. The development of high throughput, automated processes achieving high yield are projected to reduce the cost for fuel cell stacks to the $300/kW level at an annual production volume of 100 MW. Several promising combinations of building types and geographical location in the U.S. were identified for installation of fuel cell CHP systems based on the LBNL modelling tool DER CAM. Life-cycle modelling and externality assessment were done for hotels and hospitals. Reduced electricity demand charges, heating credits and carbon credits can reduce the effective cost of electricity ($/kWhe) by 26-44percent in locations such as Minneapolis, where high carbon intensity electricity from the grid is displaces by a fuel cell system operating on reformate fuel. This project extends the scope of existing cost studies to include externalities and ancillary financial benefits and thus provides a more comprehensive picture of fuel cell system benefits, consistent with a policy and incentive environment that increasingly values these ancillary benefits. The project provides a critical, new modelling capacity and should aid a broad range of policy makers in assessing the integrated costs and benefits of fuel cell systems versus other distributed generation technologies.

08 HYDROGEN↗

Hydrogen-powered Electrochemically-driven CO 2 Removal from Air Containing 400 to 5000 ppm CO 2

The performance of a hydrogen-powered, electrochemically-driven CO 2 separator (EDCS) was demonstrated at cathode inlet CO 2 concentrations from 400 ppm to 5,000 ppm. The impact of current density and CO 2 concentration were evaluated to predict operating windows for various applications. The single-cell data was used to scale a 100 cm 2 , multi-cell stack using a shorted-membrane design for four applications: direct air capture (DAC), hydroxide exchange membrane fuel cell (HEMFC) air pretreatment, submarine life support, and space habitation. For DAC, a 339-cell EDCS stack (7.7 L, 17 kg) was projected to remove 1 tonne CO 2 per year. The addition of the EDCS in HEMFC systems would result in nearly a 30% increase in volume, and therefore further improvements in performance would be necessary. A module containing five 338-cell EDCS stacks (38 L, 85 kg) in parallel can support a 150 person crew at 2.1% of the volume of the liquid amine system employed in submarines. For space habitation, a 109-cell EDCS stack (3.2 L, 10 kg) is adequate for 6 crewmembers, and is less than 1% the size and 5% the weight of the current CO 2 removal system installed on the International Space Station.

25 ENERGY STORAGE↗

Experiment S009: Nuclear Emulsion

The first exposure on a spacecraft of a nuclear emulsion apparatus designed to collect 1000 high quality tracks of heavy nuclei under a negligible thickness of matter (0.07 g/sq cm) is described. The cosmic ray detector consisted of a stack of nuclear emulsions that were designed to register at least 400 heavy nuclei tracks for each 10 hours of useful exposure. The spacecraft had to be oriented in a heads-up attitude during the 10-hour period to eliminate atmospheric albedo particles. The results are as follows: (1) a definite odd-even effect, with low abundances for elements of atomic number 7, 9, and 11; (2) a ratio O/C approximately 0.9; (3) Ne/C, Mg/C, and Si/C ratios between 0.2 and 0.3; (4) an abundance gap in the region 15 less than or equal to Z less than or equal to 19; and (5) a ratio (20 less than or equal to Z less than or equal to 28)/C 0.2, with a large concentration at Z = 26. These results are indicative that successful exposures of nuclear emulsions were obtained on the Gemini 11 mission.

Odell, F. W.↗

Regenerative fuel cell systems for space station

Regenerative fuel cell (RFC) systems are the leading energy storage candidates for Space Station. Key design features are the advanced state of technology readiness and high degree of system level design flexibility. Technology readiness was demonstrated through testing at the single cell, cell stack, mechanical ancillary component, subsystem, and breadboard levels. Design flexibility characteristics include independent sizing of power and energy storage portions of the system, integration of common reactants with other space station systems, and a wide range of various maintenance approaches. The design features led to selection of a RFC system as the sole electrochemical energy storage technology option for the space station advanced development program.

Hoberecht, M. A.↗

Three-state Potts nematic order in stacked frustrated spin models with SO(3) symmetry

Here, we propose stacked two-dimensional lattice designs of frustrated and SO(3) symmetric spin models consisting of antiferromagnetic (AF) triangular and ferromagnetic (FM) sixfold symmetric sublattices that realize emergent $\mathbb{Z}_{3}$ Potts nematic order. Considering bilinear-biquadratic spin interactions, our models describe an SO(3)-symmetric triangular lattice AF subject to a fluctuating magnetization arising from the FM coupled sublattice. We focus on the classical AFM-FM windmill model and map out the zero- and finite-temperature phase diagram using Monte Carlo simulations and analytical calculations. We discover a state with composite Potts nematic order above the ferrimagnetic three-sublattice up-up-down ground state and relate it to Potts phases in SO(3)-broken Heisenberg and Ising AFMs in external magnetic fields. Finally, we show that the biquadratic exchange in our model is automatically induced by thermal and quantum fluctuations in the purely bilinear Heisenberg model, easing the requirements for realizing these lattice designs experimentally.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving transition to IPv6-only via RFC8925 and IPv4 DNS Interventions

Nine years have passed since the American Registry for Internet Numbers exhausted its allocation of Internet Protocol version 4 (IPv4) addresses, and four years have passed since the United States Government mandated federal agencies to complete the transition to Internet Protocol version 6 (IPv6). Despite the IPv4 address shortage and IPv6 mandate, Federally Funded Research and Development Centers (FFRDCs) are still struggling to sunset IPv4. As demonstrated on SC23’s SC23v6 wireless network, newer tooling such as RFC8925 allows clients to disable their IPv4 protocol stack while retaining legacy IP connectivity via the RFC6145 translation algorithm. However, SC23v6 wireless clients without RFC8925 support or a disabled IPv6 stack would continue to receive internet access via legacy IPv4. This paper introduces a method of using poisoned IPv4 Domain Name System (DNS) records to gracefully inform IPv4-only clients at SC24’s SC24v6 wireless network about their inability to use the current version of internet protocol, with a goal of minimal impact to RFC8925 and dual-stack clients. When implemented as designed, this method may improve supportability and user experience of IPv6-only deployments at FFRDCs.

Costello, Thomas M↗

Analyzing the suitability of contemporary 3D-stacked PIM architectures for HPC scientific applications

Scaling off-chip bandwidth is challenging due to fundamental limitations, such as a fixed pin count and plateauing signaling rates. Recently, vendors have turned to 2.5D and 3D stacking to closely integrate system components. Interestingly, these technologies can integrate a logic layer under multiple memory dies, enabling computing capability inside a memory stack. This trend in stacking is making PIM architectures commercially viable. In this work, we investigate the suitability of offloading kernels in scientific applications onto 3D stacked PIM architectures. We evaluate several hardware constraints resulted from the stacked structure. We perform extensive simulation experiments and in-depth analysis to quantify the impact of application locality in TLBs, data caches, and memory stacks. Our results also identify design optimization areas in software and hardware for HPC scientific applications.

Peng, Ivy Bo↗

Production of pulsed electric fields using capacitively coupled electrodes

It is shown that pulsed electric fields can be produced over extended volumes by taking advantage of the internal capacitances in a stacked array of electrodes. The design, construction, and performance of practical arrays are discussed. The prototype arrays involved fields of 100-1000 V/cm extending over several centimeters. Scaling to larger physical dimensions is straightforward.

Kendall, B. R. F.↗

Proton exchange membrane fuel cells for space and electric vehicle applications: From basic research to technology development

The proton exchange membrane fuel cell (PEMFC) is one of the most promising electrochemical power sources for space and electric vehicle applications. The wide spectrum of R&D activities on PEMFC's, carried out in our Center from 1988 to date, is as follows (1) Electrode Kinetic and Electrocatalysis of Oxygen Reduction; (2) Optimization of Structures of Electrodes and of Membrane and Electrode Assemblies; (3) Selection and Evaluation of Advanced Proton Conducting Membranes and of Operating Conditions to Attain High Energy Efficiency; (4) Modeling Analysis of Fuel Cell Performance and of Thermal and Water Management; and (5) Engineering Design and Development of Multicell Stacks. The accomplishments on these tasks may be summarized as follows: (1) A microelectrode technique was developed to determine the electrode kinetic parameters for the fuel cell reactions and mass transport parameters for the H2 and O2 reactants in the proton conducting membrane. (2) High energy efficiencies and high power densities were demonstrated in PEMFCs with low platinum loading electrodes (0.4 mg/cm(exp 2) or less), advanced membranes and optimized structures of membrane and electrode assemblies, as well as operating conditions. (3) The modeling analyses revealed methods to minimize mass transport limitations, particularly with air as the cathodic reactant; and for efficient thermal and water management. (4) Work is in progress to develop multi-kilowatt stacks with the electrodes containing low platinum loadings.

Srinivasan, Supramaniam↗

High-Performance I/O: HDF5 for Lattice QCD

Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design and implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.

Kurth, Thorsten↗

High-Performance I/O: HDF5 for Lattice QCD

Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design and implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.

97 MATHEMATICS AND COMPUTING↗

High-power converters for space applications

Phase 1 was a concept definition effort to extend space-type dc/dc converter technology to the megawatt level with a weight of less than 0.1 kg/kW (220 lb./MW). Two system designs were evaluated in Phase 1. Each design operates from a 5 kV stacked fuel cell source and provides a voltage step-up to 100 kV at 10 A for charging capacitors (100 pps at a duty cycle of 17 min on, 17 min off). Both designs use an MCT-based, full-bridge inverter, gaseous hydrogen cooling, and crowbar fault protection. The GE-CRD system uses an advanced high-voltage transformer/rectifier filter is series with a resonant tank circuit, driven by an inverter operating at 20 to 50 kHz. Output voltage is controlled through frequency and phase shift control. Fast transient response and stability is ensured via optimal control. Super-resonant operation employing MCTs provides the advantages of lossless snubbing, no turn-on switching loss, use of medium-speed diodes, and intrinsic current limiting under load-fault conditions. Estimated weight of the GE-CRD system is 88 kg (1.5 cu ft.). Efficiency of 94.4 percent and total system loss is 55.711 kW operating at 1 MW load power. The Maxwell system is based on a resonance transformer approach using a cascade of five LC resonant sections at 100 kHz. The 5 kV bus is converted to a square wave, stepped-up to a 100 kV sine wave by the LC sections, rectified, and filtered. Output voltage is controlled with a special series regulator circuit. Estimated weight of the Maxwell system is 83.8 kg (4.0 cu ft.). Efficiency is 87.2 percent and total system loss is 146.411 kW operating at 1 MW load power.

Park, J. N.↗

Benchmarking Solid-State Batteries Containing Sulfide Separators: Effects of Electrode Composition and Stack Pressure

Integrating sulfide separators into solid-state batteries (SSBs) containing high energy cathodes typically requires one or more materials and engineering solutions including: (i) applying interfacial coatings to mitigate electrolyte decomposition, (ii) applying high stack pressures to form robust solid-solid contacts, and (iii) using alloying anodes to avoid Li dendrite formation. Despite the promise of these approaches, a lack of standardized testing protocols makes it difficult to directly compare results among different studies. To address this problem, the present work benchmarks the performance of SSBs containing β-Li 3 PS 4 (LPS) separators and composite cathodes. By systematically varying the anode/cathode composition and stack pressure, this work demonstrates that cathode design is a major bottleneck for solid-state cells cycled at low rates (<100 µA cm -2 ). Operando stack pressure measurements show that, while mechanical confinement generally promotes higher active material utilization and cycling stability, this strategy alone does not address interfacial reactivity between LPS and high voltage cathodes. Here, these results also demonstrate that stress evolution during cycling is dominated by volume changes at the Li metal anode. Finally, we show that FeS 2 cathodes with moderate operating voltages (<3 V vs Li/Li + ) exhibit superior cycling performance compared to high voltage cathodes by facilitating formation of stable cathode/electrolyte interfaces.

25 ENERGY STORAGE↗

Hubble Space Telescope EVA Multisetting Torque Limiter redesign

The Hubble Space Telescope (HST) Multisetting Torque Limiter will be used by astronauts during the First Servicing Mission STS-61. It was designed to replace several individual torque limiters. This replacement reduces the number of tools required as well as reduce the time required for servicing. The Multisetting Torque Limiter design specified five separate torque settings: 2, 5.3, 9, 35 and 45 ft-lbs. This original units were tested at the 2, 5.3, and 9 ft-lbs settings and did not meet the design specifications. The 35 ft-lb and 45 ft-lb torque settings were not incorporated into the original flight design. The objective of the Goddard Space Flight Center (GSFC) redesign effort is to incorporate all five torque settings into a flight design which means the requirements for the first HST Servicing Mission. The first target of the redesign effort focused on the spring chamber and ball detent design. The original design used belleville springs in parallel; the new design changed this configuration to belleville springs stacked in series. The current engineering unit was successfully tested in ambient environment at all five settings. A flight design will soon undergo thermal vacuum testing to evaluate its performance at the temperature extremes.

Richards, Paul W.↗

Energy Conservation Alternatives Study (ECAS): Conceptual Design and Implementation Assessment of a Utility Steam Plant with Conventional Furnace and Wet Lime Stack Gas Scrubbers

A study was performed to estimate the technical/economic characteristics of a steam power plant (3500 pounds per square inch gauge, 1000 degrees Fahrenheit / 1000 degrees Fahrenheit) with a coal-burning radiant furnace and a wet lime stack gas scrubber to control sulfur emissions. Particulate emissions were controlled by an electrostatic precipitator operating at 300 degrees Fahrenheit. The stack gas from the scrubber was reheated from 125 degrees Fahrenheit to 250 degrees Fahrenheit as a base case, and from 125 degrees Fahrenheit to 175 degrees Fahrenheit as an alternate case. The study was performed on a basis consistent with the General Electric ECAS Phase II evaluation of advanced energy conversion systems for electric utility baseload applications using coal or coal-derived fuels. A conceptual design of the power plant was developed, including the on-site calcination of limestone to lime and the provision of sludge ponds to store the products of flue gas scrubbing. From this design, estimates were derived for power plant efficiency, capital cost, environmental intrusion characteristics, natural resource requirements, and cost of electricity at an assumed capacity factor of 65 percent. An implementation assessment was performed where factors affecting applicability of the conceptual design power plant in electric utility generation systems were appraised. At 250 degrees Fahrenheit and 175 degrees Fahrenheit stack gas temperatures respectively, the plants showed a cost of electricity of 39.8 and 37.0 mills per kilowatt-hours and overall plant efficiencies of 32 percent and 34 percent.

Brown, Dale H.↗

Asynchronous Runtimes in Action: An Introspective Framework for a Next Gen Runtime

One of the most critical challenges that new high performance systems face is the lack of system software support for these large scale systems. Investment on system stack components is essential in the development, debugging and optimization of the new emerging programming models. These emerging models have the promise to better utilize the vast hardware resources available in current and future systems. To aid in the development of applications and new system stacks, runtimes, as instances of their respective execution models, need to produce facilities to introspect their inner workings and allow an indepth attribution of performance bottlenecks and computational patterns. In other words, the runtime systems need to reduce their opacity to observers so that users of a novel program execution model can adapt their designs to fit the intended model usage, regardless of the layer that they are working on. This design/development loop (akin to co-design) enables synergistic opportunities across the entire computational stack. This paper presents the design and implementation of a simple “gray” box performance attribution harness running inside a fine grain runtime system: the Open Community Runtime (OCR). We showcase what such a framework can indicate regarding the runtime behavior while running at scale. To this end, we have designed a set of synthetic scenarios aimed to test the runtime at their best and worst cases. We present an analysis of the most important runtime features, properties and idiosyncrasies that will affect the development of new runtime features, algorithmic selection, and application development.

high performance distributed runtimes↗

Thermal management of advanced fuel cell power systems

It is shown that fuel cell devices are particularly attractive for the high-efficiency, high-reliability space hardware necessary to support upcoming space missions. These low-temperature hydrogen-oxygen systems necessarily operate with two-phase water. In either PEMFCs (proton exchange membrane fuel cells) or AFCs (alkaline fuel cells), engineering design must be critically focused on both stack temperature control and on the relative humidity control necessary to sustain appropriate conductivity within the ionic conductor. Water must also be removed promptly from the hardware. Present designs for AFC space hardware accomplish thermal management through two coupled cooling loops, both driven by a heat transfer fluid, and involve a recirculation fan to remove water and heat from the stack. There appears to be a certain advantage in using product water for these purposes within PEM hardware, because in that case a single fluid can serve both to control stack temperature, operating simultaneously as a heat transfer medium and through evaporation, and to provide the gas-phase moisture levels necessary to set the ionic conductor at appropriate performance levels. Moreover, the humidification cooling process automatically follows current loads. This design may remove the necessity for recirculation gas fans, thus demonstrating the long-term reliability essential for future space power hardware.

Vanderborgh, N. E.↗