Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stack design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Production of pulsed electric fields using capacitively coupled electrodes

It is shown that pulsed electric fields can be produced over extended volumes by taking advantage of the internal capacitances in a stacked array of electrodes. The design, construction, and performance of practical arrays are discussed. The prototype arrays involved fields of 100-1000 V/cm extending over several centimeters. Scaling to larger physical dimensions is straightforward.

Kendall, B. R. F.↗

Proton exchange membrane fuel cells for space and electric vehicle applications: From basic research to technology development

The proton exchange membrane fuel cell (PEMFC) is one of the most promising electrochemical power sources for space and electric vehicle applications. The wide spectrum of R&D activities on PEMFC's, carried out in our Center from 1988 to date, is as follows (1) Electrode Kinetic and Electrocatalysis of Oxygen Reduction; (2) Optimization of Structures of Electrodes and of Membrane and Electrode Assemblies; (3) Selection and Evaluation of Advanced Proton Conducting Membranes and of Operating Conditions to Attain High Energy Efficiency; (4) Modeling Analysis of Fuel Cell Performance and of Thermal and Water Management; and (5) Engineering Design and Development of Multicell Stacks. The accomplishments on these tasks may be summarized as follows: (1) A microelectrode technique was developed to determine the electrode kinetic parameters for the fuel cell reactions and mass transport parameters for the H2 and O2 reactants in the proton conducting membrane. (2) High energy efficiencies and high power densities were demonstrated in PEMFCs with low platinum loading electrodes (0.4 mg/cm(exp 2) or less), advanced membranes and optimized structures of membrane and electrode assemblies, as well as operating conditions. (3) The modeling analyses revealed methods to minimize mass transport limitations, particularly with air as the cathodic reactant; and for efficient thermal and water management. (4) Work is in progress to develop multi-kilowatt stacks with the electrodes containing low platinum loadings.

Srinivasan, Supramaniam↗

High-Performance I/O: HDF5 for Lattice QCD

Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design and implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.

Kurth, Thorsten↗

High-Performance I/O: HDF5 for Lattice QCD

Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design and implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.

97 MATHEMATICS AND COMPUTING↗

High-power converters for space applications

Phase 1 was a concept definition effort to extend space-type dc/dc converter technology to the megawatt level with a weight of less than 0.1 kg/kW (220 lb./MW). Two system designs were evaluated in Phase 1. Each design operates from a 5 kV stacked fuel cell source and provides a voltage step-up to 100 kV at 10 A for charging capacitors (100 pps at a duty cycle of 17 min on, 17 min off). Both designs use an MCT-based, full-bridge inverter, gaseous hydrogen cooling, and crowbar fault protection. The GE-CRD system uses an advanced high-voltage transformer/rectifier filter is series with a resonant tank circuit, driven by an inverter operating at 20 to 50 kHz. Output voltage is controlled through frequency and phase shift control. Fast transient response and stability is ensured via optimal control. Super-resonant operation employing MCTs provides the advantages of lossless snubbing, no turn-on switching loss, use of medium-speed diodes, and intrinsic current limiting under load-fault conditions. Estimated weight of the GE-CRD system is 88 kg (1.5 cu ft.). Efficiency of 94.4 percent and total system loss is 55.711 kW operating at 1 MW load power. The Maxwell system is based on a resonance transformer approach using a cascade of five LC resonant sections at 100 kHz. The 5 kV bus is converted to a square wave, stepped-up to a 100 kV sine wave by the LC sections, rectified, and filtered. Output voltage is controlled with a special series regulator circuit. Estimated weight of the Maxwell system is 83.8 kg (4.0 cu ft.). Efficiency is 87.2 percent and total system loss is 146.411 kW operating at 1 MW load power.

Park, J. N.↗

Benchmarking Solid-State Batteries Containing Sulfide Separators: Effects of Electrode Composition and Stack Pressure

Integrating sulfide separators into solid-state batteries (SSBs) containing high energy cathodes typically requires one or more materials and engineering solutions including: (i) applying interfacial coatings to mitigate electrolyte decomposition, (ii) applying high stack pressures to form robust solid-solid contacts, and (iii) using alloying anodes to avoid Li dendrite formation. Despite the promise of these approaches, a lack of standardized testing protocols makes it difficult to directly compare results among different studies. To address this problem, the present work benchmarks the performance of SSBs containing β-Li 3 PS 4 (LPS) separators and composite cathodes. By systematically varying the anode/cathode composition and stack pressure, this work demonstrates that cathode design is a major bottleneck for solid-state cells cycled at low rates (<100 µA cm -2 ). Operando stack pressure measurements show that, while mechanical confinement generally promotes higher active material utilization and cycling stability, this strategy alone does not address interfacial reactivity between LPS and high voltage cathodes. Here, these results also demonstrate that stress evolution during cycling is dominated by volume changes at the Li metal anode. Finally, we show that FeS 2 cathodes with moderate operating voltages (<3 V vs Li/Li + ) exhibit superior cycling performance compared to high voltage cathodes by facilitating formation of stable cathode/electrolyte interfaces.

25 ENERGY STORAGE↗

Hubble Space Telescope EVA Multisetting Torque Limiter redesign

The Hubble Space Telescope (HST) Multisetting Torque Limiter will be used by astronauts during the First Servicing Mission STS-61. It was designed to replace several individual torque limiters. This replacement reduces the number of tools required as well as reduce the time required for servicing. The Multisetting Torque Limiter design specified five separate torque settings: 2, 5.3, 9, 35 and 45 ft-lbs. This original units were tested at the 2, 5.3, and 9 ft-lbs settings and did not meet the design specifications. The 35 ft-lb and 45 ft-lb torque settings were not incorporated into the original flight design. The objective of the Goddard Space Flight Center (GSFC) redesign effort is to incorporate all five torque settings into a flight design which means the requirements for the first HST Servicing Mission. The first target of the redesign effort focused on the spring chamber and ball detent design. The original design used belleville springs in parallel; the new design changed this configuration to belleville springs stacked in series. The current engineering unit was successfully tested in ambient environment at all five settings. A flight design will soon undergo thermal vacuum testing to evaluate its performance at the temperature extremes.

Richards, Paul W.↗

Energy Conservation Alternatives Study (ECAS): Conceptual Design and Implementation Assessment of a Utility Steam Plant with Conventional Furnace and Wet Lime Stack Gas Scrubbers

A study was performed to estimate the technical/economic characteristics of a steam power plant (3500 pounds per square inch gauge, 1000 degrees Fahrenheit / 1000 degrees Fahrenheit) with a coal-burning radiant furnace and a wet lime stack gas scrubber to control sulfur emissions. Particulate emissions were controlled by an electrostatic precipitator operating at 300 degrees Fahrenheit. The stack gas from the scrubber was reheated from 125 degrees Fahrenheit to 250 degrees Fahrenheit as a base case, and from 125 degrees Fahrenheit to 175 degrees Fahrenheit as an alternate case. The study was performed on a basis consistent with the General Electric ECAS Phase II evaluation of advanced energy conversion systems for electric utility baseload applications using coal or coal-derived fuels. A conceptual design of the power plant was developed, including the on-site calcination of limestone to lime and the provision of sludge ponds to store the products of flue gas scrubbing. From this design, estimates were derived for power plant efficiency, capital cost, environmental intrusion characteristics, natural resource requirements, and cost of electricity at an assumed capacity factor of 65 percent. An implementation assessment was performed where factors affecting applicability of the conceptual design power plant in electric utility generation systems were appraised. At 250 degrees Fahrenheit and 175 degrees Fahrenheit stack gas temperatures respectively, the plants showed a cost of electricity of 39.8 and 37.0 mills per kilowatt-hours and overall plant efficiencies of 32 percent and 34 percent.

Brown, Dale H.↗

Asynchronous Runtimes in Action: An Introspective Framework for a Next Gen Runtime

One of the most critical challenges that new high performance systems face is the lack of system software support for these large scale systems. Investment on system stack components is essential in the development, debugging and optimization of the new emerging programming models. These emerging models have the promise to better utilize the vast hardware resources available in current and future systems. To aid in the development of applications and new system stacks, runtimes, as instances of their respective execution models, need to produce facilities to introspect their inner workings and allow an indepth attribution of performance bottlenecks and computational patterns. In other words, the runtime systems need to reduce their opacity to observers so that users of a novel program execution model can adapt their designs to fit the intended model usage, regardless of the layer that they are working on. This design/development loop (akin to co-design) enables synergistic opportunities across the entire computational stack. This paper presents the design and implementation of a simple “gray” box performance attribution harness running inside a fine grain runtime system: the Open Community Runtime (OCR). We showcase what such a framework can indicate regarding the runtime behavior while running at scale. To this end, we have designed a set of synthetic scenarios aimed to test the runtime at their best and worst cases. We present an analysis of the most important runtime features, properties and idiosyncrasies that will affect the development of new runtime features, algorithmic selection, and application development.

high performance distributed runtimes↗

Thermal management of advanced fuel cell power systems

It is shown that fuel cell devices are particularly attractive for the high-efficiency, high-reliability space hardware necessary to support upcoming space missions. These low-temperature hydrogen-oxygen systems necessarily operate with two-phase water. In either PEMFCs (proton exchange membrane fuel cells) or AFCs (alkaline fuel cells), engineering design must be critically focused on both stack temperature control and on the relative humidity control necessary to sustain appropriate conductivity within the ionic conductor. Water must also be removed promptly from the hardware. Present designs for AFC space hardware accomplish thermal management through two coupled cooling loops, both driven by a heat transfer fluid, and involve a recirculation fan to remove water and heat from the stack. There appears to be a certain advantage in using product water for these purposes within PEM hardware, because in that case a single fluid can serve both to control stack temperature, operating simultaneously as a heat transfer medium and through evaporation, and to provide the gas-phase moisture levels necessary to set the ionic conductor at appropriate performance levels. Moreover, the humidification cooling process automatically follows current loads. This design may remove the necessity for recirculation gas fans, thus demonstrating the long-term reliability essential for future space power hardware.

Vanderborgh, N. E.↗

Design of a multi-functional gel polymer electrolyte with a 3D compact stacked polymer micro-sphere matrix for high-performance lithium metal batteries

We report lithium metal batteries (LMBs) are considered as promising high energy density batteries. However, they still suffer from poor cyclability due to the instability of solid electrolyte interphases (SEIs) and Li dendrite issues. Herein, a novel 3D densely packed multifunctional crosslinked gel polymer electrolyte (PHGPE) has been synthesized by in situ copolymerization of pentaerythritol tetraacrylate and 2-hydroxyethyl acrylate in a liquid electrolyte via a thermal initiation method. Due to intermolecular hydrogen bonding in the frameworks, the PHGPE exhibits a 3D compact-stacked and crosslinked micro-sphere structure, which benefits the construction of homogeneous Li + flux, enabling uniform Li plating/stripping and formation of robust SEIs onto the lithium electrode. Benefiting from the above advantages, symmetric Li cells in the PHGPE deliver excellent cyclabilities of 6000 h at a current density of 1 mA cm -2 (1 mA h cm -2 ) and 7700 h at 0.5 mA cm -2 (2 mA h cm -2 ). Moreover, the PHGPE has such a wide electrochemical window that it is compatible with both high-voltage LiNi 0.8 Co 0.1 Mn 0.1 O 2 and sulfur cathodes to realize long cycle life. Additionally, a LiFePO 4 based pouch size LMB also presents promising performance. Therefore, this study of the PHGPE has opened a new avenue for high-performance LMBs with excellent versatility and practicality.

25 ENERGY STORAGE↗

Patterned OLEDs: effect of substrate corrugation pitch and height

Abstract An ongoing OLED challenge is cost-effective enhancement of light extraction, i.e., increasing the external quantum efficiency ( EQE ∼20% in conventional devices). OLEDs on corrugated substrates often show enhanced EQE s providing insight into light emission processes. In particular, patterned plastic substrates directly imprinted easily at room temperature and amenable to low-cost R2R production are ideal for studying/optimizing various structures, further elucidating the extraction process. We show new semi-quantitative data of the effect of the pitch ( a ) and height/depth ( h ) of plastic substrate patterns on the OLEDs’ stack and EQE , focusing on new designs, interestingly, some showing surprisingly enhanced EQE s that were neither reported nor discussed before. These includ e : ( i ) shallow ( h < 200 nm) convex polycarbonate with a ∼ 750 versus ∼400 nm, where the h gradually decreases as the OLED stack is built and ( ii ) concave PET/CAB with large a (∼2.8 and ∼7.8 μ m), where the EQE enhancement of conformal OLEDs may be due largely to scattering. EQE s of green, blue, and white phosphorescent OLEDs were measured. OLEDs on substrates with narrow a ∼ 400 nm and low h < 200 nm s h owed no enhancement, resembling flat devices. In contrast, OLEDs on substrates with comparable or smaller h , but larger a ∼ 750 nm show signific a nt EQE enhancement despite h reduction across the stack. Green OLEDs with a ∼ 750 nm and h ∼ 160 to ∼180 nm, showed EQE s ∼30%, reaching ∼58% with substrate mode extraction. Surprisingly, fully conformal OLEDs on a PET/CAB substrate with a ∼ 7.8 μ m showed blue a nd white EQE s reaching ∼33%, without substrate mode extraction. The enhancing patterns increase the OLEDs’ EQE by reducing surface plasmon excitation and internal waveguiding. The experimental results for OLEDs on substrates with a < 2 μ m are supported by scattering matrix simulations that assume conformal stacks, incorporating diffraction for internal losses reduction. EQE enhancement not predicted by simulations may be due additionally to scattering mostly for substrates with a signific a ntly larger than the emitting wavelength.

42 ENGINEERING↗

The ATIC Experiment : Performance of the Scintillator Hodoscope and the BGO Calorimeter

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its first flight from McMurdo, Antarctica, 28/12/00 to 13/01/01, recording over 360 hours of data. The design goal for ATIC was to measure the Cosmic Ray composition and energy spectra from approximately 50 GeV to near 100 TeV utilizing a Si-matrix detector, a scintillator hodoscope, carbon targets and a calorimeter consisting of a stack of BGO scintillator crystals. The design, operation, and in-flight performance of the scintillator hodoscope and the BGO calorimeter are described.

Isbert, J.↗

The ATIC Experiment: Performance of the Scintillator Hodoscopes and the BGO Calorimeter

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its first flight from Mcmurdo, Antarctica 28/12/2000 to 13/01/2001, local time, recording over 360 hours of data. The design goal of ATIC was to measure the Cosmic Ray composition and energy spectra from approximately 50 GeV to near 100 TeV utilizing a Si-matrix detector, a scintillator hodoscope, carbon targets and a calorimeter consisting of a stack of BGO scintillator crystals. The design, the operations and in-flight performance of the scintillator hodoscope and the BGO calorimeter are described.

Isbert, Joachim↗

STGSTK: A computer code for predicting multistage axial flow compressor performance by a meanline stage stacking method

A FORTRAN computer code is presented for off-design performance prediction of axial-flow compressors. Stage and compressor performance is obtained by a stage-stacking method that uses representative velocity diagrams at rotor inlet and outlet meanline radii. The code has options for: (1) direct user input or calculation of nondimensional stage characteristics; (2) adjustment of stage characteristics for off-design speed and blade setting angle; (3) adjustment of rotor deviation angle for off-design conditions; and (4) SI or U.S. customary units. Correlations from experimental data are used to model real flow conditions. Calculations are compared with experimental data.

Steinke, R. J.↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗