Search NASA⌕ Search

SEARCH · Search NASA

Results for “Strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy

Background: We investigated the extent to which the administered dose (activity) level can be reduced without sacrificing diagnostic accuracy for three reconstruction strategies for SPECT-myocardial perfusion imaging (MPI). Methods: We optimized the parameters of the three reconstruction strategies for perfusion-defect detection over a range of simulated administered dose levels using a set of hybrid studies (derived from 190 subjects) consisting of clinical SPECT-MPI data modified to contain realistic simulated lesions. The optimized strategies we considered are filtered backprojection (FBP) with no correction for degradations, ordered-subsets expectation-maximization (OS-EM) with attenuation correction (AC), scatter correction (SC), and resolution correction (RC), and OS-EM with scatter and resolution correction only. Each study was evaluated using a total perfusion deficit (TPD) score computed by the Quantitative Perfusion SPECT (QPS) software package. We conducted a receiver operating characteristics (ROC) study based on the TPD scores for each dose level and reconstruction strategy. Results: For FBP, the achieved optimum values of the area under the ROC curve (AUC) at 100%, 50%, 25%, and 12.5% of standard dose were 0.75, 0.74, 0.72, and 0.70, respectively, compared to 0.81, 0.79, 0.76, and 0.74 for OS-EM with AC–SC–RC and 0.78, 0.77, 0.74, 0.72 for OS-EM with SC–RC. Conclusions: Our results suggest that studies reconstructed by OS-EM with AC–SC–RC could possibly be reduced, on average, to 25% of the originally administered dose without causing diagnostic accuracy (AUC) to decrease below that of FBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the effect of multiple load flexibility strategies on commercial building electricity demand and services via surrogate modeling

The expansion of commercial building demand response as a demand-side management resource for the electric grid necessitates new decision support resources for customers seeking to assess the benefit–risk tradeoffs of possible strategies for energy flexible building operations. To address this need, we, in this study, develop surrogate models that predict the impacts of several load flexibility strategies on commercial building electricity demand and indoor temperature, focusing on offices and retail buildings at multiple scales. The surrogate models are fit to a synthetic database generated via whole building simulations, which establish the relationships between the key operational features of a given strategy and potential changes in building demand and temperature across a variety of contexts. The surrogate models are translated to a Bayesian framework to allow straightforward communication of uncertainty and parameter updating given new evidence. We find strong predictive performance across the suite of models, underscoring the usefulness of the approach in guiding decisions about implementing load flexibility strategies under a particular set of operational and environmental conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of fuel film formation and soot emissions in a GDI engine during cold-start with Split-injection strategies

This study investigates the impact of fuel-film formation on engine-out soot emissions in a gasoline direct injection (GDI) engine under cold-start conditions. Split-injection strategies were applied by varying the number of injections, injection duration, and total fuel quantity to affect wall wetting and control the average in-cylinder equivalence ratio. A combined experimental and numerical approach was employed to analyze fuel-film deposition, combustion efficiency, and engine-out soot and unburnt hydrocarbons (UHC) emissions. In particular, fuel film distribution estimated by means of non-reacting, 3-D, computational fluid dynamics (CFD) simulations, together with experimentally measured soot data, were used to investigate fuel film formation and its role in soot generation. In the experiments, a skip-fired engine control strategy was applied to mimic the transient nature of engine cold-start operation. The results indicate that, under the same total number of injections, increasing the average in-cylinder equivalence ratio through longer injection durations improves combustion stability, as indicated by the decrease of the coefficient of variation of IMEP n (Net Indicated Mean Effective Pressure) from 6.0 % to 0.6 %. However, this strategy leads to higher soot emissions, which increased by nearly an order of magnitude, primarily due to enhanced wall-film formation. In contrast, increasing the number of injections while maintaining a constant equivalence ratio significantly impacts fuel-film deposition and, consequently, soot emissions, with a fivefold reduction of the measured engine-out soot, decreasing from 3.5 mg to 0.7 mg. A soot-film correlation was developed and achieved a high coefficient of determination (r 2 = 0.95) and was further extended to account for spark timing effects. These findings confirm the effectiveness of split-injection for avoiding wall film formation and soot emissions, and the critical role of fuel film in soot generation, supporting the hypothesis that pool fires play a crucial role in contributing to soot formation under these cold-start conditions. In conclusion, the study also indicates the value of a predictive soot-film correlation for developing cold-start emission control strategies.

Engine Cold-start↗

A hetero-micro-seeding strategy for readily crystallizing closely related protein variants

Protein crystallization remains difficult to rationalize and screening for optimal crystallization conditions is a tedious and time consuming procedure. Here, we report a hetero-micro-seeding strategy for producing high resolution crystals of closely related protein variants, where micro crystals from a readily crystallized variant are used as seeds to develop crystals of other variants less amenable to crystallization. We applied this strategy to Bovine Pancreatic Trypsin Inhibitor (BPTI) variants, which would not crystallize using standard crystallization practice. Out of six variants in our analysis, only one called BPTI-[5,55]A14G formed well behaving crystals; and the remaining five (A14GA38G, A14GA38V, A14GA38L, A14GA38I, and A14GA38K) could be crystallized only using micro-seeds from the BPTI-[5,55]A14G crystal. All hetero-seeded crystals diffracted at high resolution with minimum mosaicity, retaining the same space group and cell dimension. Moreover, hetero-micro-seeding did not introduce any biases into the mutant’s structure toward the seed structure, as demonstrated by A14GA38I structures solved using micro-seeds from A14GA38G, A14GA38L and A14GA38I. Though hetero-micro-seeding is a simple and almost naïve strategy, this is the first direct demonstration of its workability. We believe that hetero-micro-seeding, which is contrasting with the popular idea that crystallization requires highly purified proteins, could contribute a new tool for rapidly solving protein structures in mutational analysis studies. - Highlights: • In hetero-micro-seeding, hard-to-crystalize mutants are crystallized using micro-seeds from a readily crystalized variant. • Hetero-micro-seeding did not introduce any biases of the mutant structure toward the seed structure. • Though hetero-micro-seeding is a simple strategy, this is the first direct demonstration of its workability at atomic level.

36 MATERIALS SCIENCE↗

Active learning strategy for high fidelity short-term data-driven building energy forecasting

The quality of a data-driven model is heavily dependent on the quality of data. Data from building operation often have data bias problems, which means that the data sample is collected in a way that some members of the intended data population are less likely to be included than others. Data-driven energy forecasting models built on such data hence are biased and could lead to large forecasting errors. Active learning—an effective method to defying data bias—is rarely studied or applied in the area of data-driven building energy forecasting modeling. This paper attempts to fill this gap and explores the application of active learning in data-driven building energy forecasting. The developed strategy in this paper efficiently generate informative training data within a time budget and uses block design to passively consider weather disturbances. The developed active learning strategy is applied and evaluated in both virtual and real-building testbeds against traditional data-driven methods. Via these virtual and real-building evaluation cases, we have demonstrated that the data bias problem typically exists in building operation data is resolved by applying the developed active learning strategy. Furthermore, building energy forecasting models trained from data generated from the active learning strategy have shown improved performances in both model accuracy and model extendibility perspectives. The effectiveness of the block design module is also validated to effectively consider the impact of weather conditions on active learning design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient cooling strategies – A critical review and qualitative assessment

The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of robust pressure management strategies for geologic CO 2 sequestration

Injecting CO 2 into deep geologic formations for permanent storage can potentially lead to leakage or induced seismicity if the overpressures exceed the fracture gradient or fault re-activation pressure. Strategies that remove reservoir fluids before or after injection may reduce these risks. But, even extensively characterized reservoirs can have substantial gaps in characterization necessary for developing optimal deterministic or even probabilistic pressure management strategies. The characterization data may not provide well-defined bounds or distributions of reservoir parameters or conditions (permeability, fault locations, fracture gradient, fault reactivation pressure). To assess the impact of these uncertainties, we present an approach for evaluating alternative pressure management strategies based on their robustness of meeting project performance criteria. We quantify the robustness of alternative strategies against several criteria: (1) exceeding fault re-activation pressure, (2) failing to inject a desired quantity of CO 2 , (3) exceeding a maximum quantity of extracted brine, and (4) failing to reach a desired extraction efficiency. Our approach allows nuances of competing and complimentary criteria to be quantitatively evaluated in a manner and in a level of detail not possible with optimization approaches. We illustrate the fundamentals of the approach on a simple one-dimensional analytical example using the Thiem equation. Here, we demonstrate the approach using a numerical flow and transport model with uncertain heterogeneous permeabilities using data and site characteristics from the Rock Springs Uplift Carbon Storage Site in southwestern Wyoming.

58 GEOSCIENCES↗

Evaluation of a self-equilibrium cutting strategy for the contour method of residual stress measurement

An assessment of cutting-induced plasticity (CIP) is performed, by finite element (FE) prediction of the plastic strain accumulation along the cut tip when the EDM wire sections the NeT TG4 weld benchmark specimen along two cutting directions. The first direction corresponds to a conventional (C) cutting strategy, whereby the EDM wire cuts through the thickness of the weld specimen and travels in a direction transverse to the weld. The second direction corresponds to a self-equilibrating cutting (SE) strategy, whereby the EDM wire cuts across the transverse direction of the weld specimens and travels through the thickness of the plate. The cutting thus progresses simultaneously through the compression-tension-compression regions of present weld residual stress (WRS) field. This type of cutting strategy is believed to minimize the CIP by minimising residual stress redistribution during cutting, due to stress equilibration across the sectioned material. The simulated cutting procedures are conducted under a range of clamping conditions to assess whether mechanical restraint has a primary or secondary influence on CIP accumulation. Both predictions of CIP and the resultant back-calculated WRS demonstrate that (i) mechanical restraint is the primary variable influencing CIP development, and (ii) under no circumstance does a self-equilibrating cutting strategy perform significantly better than a conventional cutting approach. Furthermore, the reason that self-equilibrating cuts are not effective is illustrated by calculating the Mode I (K I ) stress intensity factor (SIF) along the cut tip, and correlating trends in K I to CIP development.

36 MATERIALS SCIENCE↗

Strategies for Online Organ Motion Correction for Intensity-Modulated Radiotherapy of Prostate Cancer: Prostate, Rectum, and Bladder Dose Effects

Purpose: To quantify and evaluate the accumulated prostate, rectum, and bladder dose for several strategies including rotational organ motion correction for intensity-modulated radiotherapy (IMRT) of prostate cancer using realistic organ motion data. Methods and Materials: Repeat computed tomography (CT) scans of 19 prostate patients were used. Per patient, two IMRT plans with different uniform margins were created. To quantify prostate and seminal vesicle motion, repeat CT clinical target volumes (CTVs) were matched onto the planning CTV using deformable registration. Four different strategies, from online setup to full motion correction, were simulated. Rotations were corrected for using gantry and collimator angle adjustments. Prostate, rectum, and bladder doses were accumulated for each patient, plan, and strategy. Minimum CTV dose (D{sub min}), rectum equivalent uniform dose (EUD, n = 0.13), and bladder surface receiving >=78 Gy (S78), were calculated. Results: With online CTV translation correction, a 7-mm margin was sufficient (i.e., D{sub min} >= 95% of the prescribed dose for all patients). A 4-mm margin required additional rotational correction. Margin reduction lowered the rectum EUD(n = 0.13) by approx2.6 Gy, and the bladder S78 by approx1.9%. Conclusions: With online correction of both translations and rotations, a 4-mm margin was sufficient for 15 of 19 patients, whereas the remaining four patients had an underdosed CTV volume <1%. Margin reduction combined with online corrections resulted in a similar or lower dose to the rectum and bladder. The more advanced the correction strategy, the better the planned and accumulated dose agreed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of 18F-Fluoro-2-Deoxyglucose Positron Emission Tomography on Treatment Strategy and Radiotherapy Planning for Stage I-II Hodgkin Disease: A Prospective Multicenter Study

Purpose: To quantify the impact of preradiotherapy 18F-fluoro-2-deoxyglucose positron-emission tomography (FDG-PET) on treatment strategy and radiotherapy planning for patients with Stage I/II Hodgkin disease included in a large prospective multicenter study. Patients and Methods: Conventional computed tomography and FDG-PET were performed just before the planned radiotherapy. The radiotherapy plan was first elaborated under blinded conditions for FDG-PET data. Then, the medical staff was asked to confirm or not confirm the treatment strategy and, if appropriate, to modify the radiotherapy plan based on additional information from FDG-PET. Results: Between January 2004 and January 2006, 137 patients were included (124 were available for analysis) in 11 centers (108 adults, 16 children). All but 1 patient had received chemotherapy before inclusion. Prechemotherapy work-up included FDG-PET for 61 patients, and data were available for elaboration of the first radiotherapy plan. Based on preradiotherapy FDG-PET data, the radiotherapy was cancelled in 6 patients (4.8%), and treatment plan modifications occurred in 16 patients (12.9%): total dose (11 patients), CTV volume (5 patients), number of beam incidences (6 patients), and number of CTV (6 patients). The concordance between the treatment strategies with or without preradiotherapy FDG-PET was 82.3%. Concordance results were not significantly different when prechemotherapy PET-CT information was available. Conclusion: Preradiotherapy FDG-PET for treatment planning in Hodgkin lymphoma may lead to significant modification of the treatment strategy and the radiotherapy planning in patients with Stage I or II Hodgkin disease, even in those who have undergone FDG-PET as part of the prechemotherapy work-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiration-Correlated Image Guidance Is the Most Important Radiotherapy Motion Management Strategy for Most Lung Cancer Patients

Purpose: The purpose of this study was to quantify the effects of four-dimensional computed tomography (4DCT), 4D image guidance (4D-IG), and beam gating on calculated treatment field margins in a lung cancer patient population. Materials and Methods: Images were acquired from 46 lung cancer patients participating in four separate protocols at three institutions in Europe and the United States. Seven patients were imaged using fluoroscopy, and 39 patients were imaged using 4DCT. The magnitude of respiratory tumor motion was measured. The required treatment field margins were calculated using a statistical recipe (van Herk M, et al. Int J Radiat Oncol Biol Phys 2000;474:1121-1135), with magnitudes of all uncertainties, except respiratory peak-to-peak displacement, the same for all patients, taken from literature. Required margins for respiratory motion management were calculated using the residual respiratory tumor motion for each patient for various motion management strategies. Margin reductions for respiration management were calculated using 4DCT, 4D-IG, and gated beam delivery. Results: The median tumor motion magnitude was 4.4 mm for the 46 patients (range 0-29.3 mm). This value corresponded to required treatment field margins of 13.7 to 36.3 mm (median 14.4 mm). The use of 4DCT, 4D-IG, and beam gating required margins that were reduced by 0 to 13.9 mm (median 0.5 mm), 3 to 5.2 mm (median 5.1 mm), and 0 to 7 mm (median 0.2 mm), respectively, to a total of 8.5 to 12.4 mm (median 8.6 mm). Conclusion: A respiratory management strategy for lung cancer radiotherapy including planning on 4DCT scans and daily image guidance provides a potential reduction of 37% to 47% in treatment field margins. The 4D image guidance strategy was the most effective strategy for >85% of the patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A general solution strategy of modified power method for higher mode solutions

A general solution strategy of the modified power iteration method for calculating higher eigenmodes has been developed and applied in continuous energy Monte Carlo simulation. The new approach adopts four features: 1) the eigen decomposition of transfer matrix, 2) weight cancellation for higher modes, 3) population control with higher mode weights, and 4) stabilization technique of statistical fluctuations using multi-cycle accumulations. The numerical tests of neutron transport eigenvalue problems successfully demonstrate that the new strategy can significantly accelerate the fission source convergence with stable convergence behavior while obtaining multiple higher eigenmodes at the same time. The advantages of the new strategy can be summarized as 1) the replacement of the cumbersome solution step of high order polynomial equations required by Booth's original method with the simple matrix eigen decomposition, 2) faster fission source convergence in inactive cycles, 3) more stable behaviors in both inactive and active cycles, and 4) smaller variances in active cycles. Advantages 3 and 4 can be attributed to the lower sensitivity of the new strategy to statistical fluctuations due to the multi-cycle accumulations. The application of the modified power method to continuous energy Monte Carlo simulation and the higher eigenmodes up to 4th order are reported for the first time in this paper. -- Graphical abstract: -- Highlights: •Modified power method is applied to continuous energy Monte Carlo simulation. •Transfer matrix is introduced to generalize the modified power method. •All mode based population control is applied to get the higher eigenmodes. •Statistic fluctuation can be greatly reduced using accumulated tally results. •Fission source convergence is accelerated with higher mode solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A critical review of operational strategies for the management of harmful algal blooms (HABs) in inland reservoirs

Occurrences of freshwater harmful algal blooms (HABs) are increasing on a global scale, largely in part due to increased nutrient input and changing climate patterns. While reservoir management strategies that can influence phytoplankton are known, there is no published guideline or protocol for the management of harmful algal blooms. There is a need to establish what factors are the predominant drivers of blooms, and how common reservoir management strategies specifically influence each factor. The following literature review seeks to establish the benefits and drawbacks of operational management strategies that currently exist. The main focus is altering hydrodynamic conditions (hypolimnetic withdrawals, surface flushing, pulsed inflow, artificial mixing), in order to induce environmental changes within the reservoir itself. Since excess nutrients are one of the biggest contributors to worsening bloom conditions, internal nutrient dynamics and reduction are also discussed. Additionally, we review the predominant seasonal factors (stratification, light, temperature, and wind) that affect likelihood of bloom occurrence and duration. In conclusion, the ultimate objective of this review is to increase understanding of the relationships between HAB drivers and reservoir operations in order to inform the development of data, modeling, and management strategies for the prevention and mitigation of blooms.

54 ENVIRONMENTAL SCIENCES↗

Characterizing the performance of node-aware strategies for irregular point-to-point communication on heterogeneous architectures

Supercomputer architectures are trending toward higher computational throughput due to the inclusion of heterogeneous compute nodes. These multi-GPU nodes increase on-node computational efficiency, while also increasing the amount of data to be communicated and the number of potential data flow paths. In this work, we characterize the performance of irregular point-to-point communication with MPI on heterogeneous compute environments through performance modeling, demonstrating the limitations of standard communication strategies for both device-aware and staging-through-host communication techniques. Presented models suggest staging communicated data through host processes then using node-aware communication strategies for high inter-node message counts. Notably, the models also predict that node-aware communication utilizing all available CPU cores to communicate inter-node data leads to the most performant strategy when communicating with a high number of nodes. Furthermore, model validation is provided via a case study of irregular point-to-point communication patterns in distributed sparse matrix–vector products. Importantly, we include a discussion on the implications model predictions have on communication strategy design for emerging supercomputer architectures.

97 MATHEMATICS AND COMPUTING↗

LCA of local strategies for energy recovery from waste in England, applied to a large municipal flow

An intense waste management (WM) planning activity is currently undergoing in England to build the infrastructure necessary to treat residual wastes, increase recycling levels and the recovery of energy from waste. From the analyses of local WM strategic and planning documents we have identified the emerging of three different energy recovery strategies: established combustion of residual waste; pre-treatment of residual waste and energy recovery from Solid Recovered Fuel in a dedicated plant, usually assumed to be a gasifier; pre-treatment of residual waste and reliance on the market to accept the 'fuel from waste' so produced. Each energy recovery strategy will result in a different solution in terms of the technology selected; moreover, on the basis of the favoured solution, the total number, scale and location of thermal treatment plants built in England will dramatically change. To support the evaluation and comparison of these three WM strategy in terms of global environmental impacts, energy recovery possibilities and performance with respect to changing 'fuel from waste' market conditions, the LCA comparison of eight alternative WM scenarios for a real case study dealing with a large flow of municipal wastes was performed with the modelling tool WRATE. The large flow of waste modelled allowed to formulate and assess realistic alternative WM scenarios and to design infrastructural systems which are likely to correspond to those submitted for approval to the local authorities. The results show that all alternative scenarios contribute to saving abiotic resources and reducing global warming potential. Particularly relevant to the current English debate, the performance of a scenario was shown to depend not from the thermal treatment technology but from a combination of parameters, among which most relevant are the efficiency of energy recovery processes (both electricity and heat) and the calorific value of residual waste and pre-treated material. The contribution and relative importance of recycling and treatment/recovery processes change with the impact category. The lack of reprocessing plants in the area of the case study has shown the relevance of transport distances for recyclate material in reducing the efficiency of a WM system. Highly relevant to the current English WM infrastructural debate, these results for the first time highlight the risk of a significant reduction in the energy that could be recovered by local WM strategies relying only on the market to dispose of the 'fuel from waste' in a non dedicated plant in the case that the SRF had to be sent to landfill for lack of treatment capacity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗