Search NASA⌕ Search

SEARCH · Search NASA

Results for “Strip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Electrochemical Immunoassay of Cotinine in Serum Based on Nanoparticle Probe and Immunochromatographic Strip

A disposable sensor for the determination of cotinine in human serum was developed based on immunochromatographic test strip and quantum dot label. In this assay, cotinine modified on quantum dot competes with cotinine in sample to bind to anti-cotinine antibody in the test strip and the quantum dots serve as signal vehicles for electrochemical readout. Some parameters governing the performance of the sensor were optimized. The sensor shows a wide linear range from 1 ng mL-1 to 100 ng mL-1 cotinine with a detection limit of 1.0 ng mL-1. The relative standard deviation (R.S.D.) of the sensor was less than 2% for cotinine. The sensor was validated with spiked human serum samples and it was found that this method was reliable in measuring cotinine in human serum with average recovery of 100.99%. The results demonstrate that this sensor is a rapid, clinically accurate, and less expensive and has the potential for point of care (POC) detection of cotinine and fast screening of tobacco smoke exposure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

From micro- to nano-scale molding of metals : size effect during molding of single crystal Al with rectangular strip punches.

A single crystal Al specimen was molded at room temperature with long, rectangular, strip diamond punches. Quantitative molding response curves were obtained at a series of punch widths, ranging from 5 {micro}m to 550 nm. A significant size effect was observed, manifesting itself in terms of significantly increasing characteristic molding pressure as the punch width decreases to 1.5 {micro}m and below. A detailed comparison of the present strip punch molding results was made with Berkovich pyramidal indentation on the same single crystal Al specimen. The comparison reveals distinctly different dependence of the characteristic pressure on corresponding characteristic length. The present results show the feasibility of micro-/nano-scale compression molding as a micro-/nano-fabrication technique, and offer an experimental test case for size-dependent plasticity theories.

36 MATERIALS SCIENCE↗

Butanol production from wood pulping hydrolysate in an integrated fermentation-gas stripping process

Wood pulping hydrolysate (WPH) containing mainly xylose and glucose as a potential substrate for acetone-butanol-ethanol (ABE) fermentation was studied. Due to the inhibitors present in the hydrolysate, several dilution levels and detoxification treatments, including overliming, activated charcoal adsorption, and resin adsorption, were evaluated for their effectiveness in relieving the inhibition on fermentation. Detoxification using resin and evaporation was found to be the most effective method in reducing the toxicity of WPH. ABE production in batch fermentation by Clostridium beijerinckii increased 68%, from 6.73 g/L in the non-treated and non-diluted WPH to 11.35 g/L in the resin treated WPH. With gas stripping for in situ product removal, ABE production from WPH increased to 17.73 g/L, demonstrating that gas stripping was effective in alleviating butanol toxicity by selectively separating butanol from the fermentation broth, which greatly improved solvents production and sugar conversion in the fermentation. (C) 2013 Elsevier Ltd. All rights reserved.

Lu, CC↗

Stannous chloride as a tool for mercury stripping in contaminated streams: Experimental assessment of toxicity in an invertebrate model species

In this work, the chronic toxicity of an innovative Hg water treatment system using tin (Sn) (II) chloride (SnCl 2 ) followed by air stripping was assessed through measurements of survival, growth, and reproduction rate in the freshwater cladoceran Ceriodaphnia dubia, a model species for toxicity testing. We first calculated the concentrations of Hg causing 25% reduction in survival and reproduction (Lethal or Inhibition Concentrations, or LC 25 and IC 25 , for survival and reproduction, respectively) through exposure to aqueous Hg at concentrations ranging from 0 to 25,000 ng L -1 . Then, we treated media (DMW and natural stream water) contaminated with Hg at LC 25 and IC 25 concentrations with SnCl 2 at a Sn:Hg stoichiometric ratio of 8:1 and air stripping and exposed C. dubia to this Sn-amended media. Our results showed that Hg significantly affected survival, reproduction rates and impaired growth. SnCl 2 -treatment removed 100% of the Hg from the media at all concentrations tested with no deleterious effects on survival, growth and reproduction. Our results confirmed the efficacy of SnCl 2 in removing aqueous Hg from stream water and showed that the added Sn did not impact C. dubia at the concentrations tested, supporting the suitability of SnCl 2 -based treatments in appropriate Hg-contaminated environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvent Degradation and Emissions from a 0.7MWe Pilot CO 2 Capture System with Two-stage Stripping

The UKy-CAER team successfully tested an advanced 0.7 MWe post-combustion CO 2 capture system on a coal-fired power plant using a heat integration process combined with two-stage stripping to enhance the CO 2 absorber performance. One of the unique feature of the UKy-CAER integrated process is a two-stage stripping unit for solvent regeneration. The secondary stripper is empowered by the heat rejection from a conventional steam-heated (primary) stripper. The secondary stripper outlet stream at the commercial scale can be used as boiler secondary combustion air, consequently enriching the flue gas with CO 2 , resulting in less energy penalty required by the CO2 capture system. The primary goal of this study was to form an initial assessment of the impact on the amine solvent from coal combustion flue gas contaminants and the potential higher oxygen content in the solvent due to incorporation of the secondary air stripper into the conventional amine scrubber/stripper system. The overall oxidative degradation was comparable to previous reports with 30 wt% MEA solvent at similar flue gas run hours. This suggests that the addition of the secondary air stripper appears to be negligible with regards to solvent oxidation.

20 FOSSIL-FUELED POWER PLANTS↗

Multiplex Electrochemical Immunoassay Using Gold Nanoparticle Probes and Immunochromatographic Strips

We describe a multiplex electrochemical immunoassay based on the use of gold nanoparticle (Au-NP) probes and immunochromatographic strips (ISs). The approach takes advantage of the speed and low cost of the conventional IS tests and the high sensitivities of the nanoparticle-based electrochemical immunoassays. Rabbit IgG(R-IgG) and human IgM (H-IgM) were used as model targets for the demonstration of the proof of concept. The Au-NPs based sandwich immunoreactions were performed on the IS, and the captured gold nanoparticle labels on the test zones were determined by highly-sensitive stripping voltammetric measurement of the dissolved gold ions (III) with a carbon paste electrode. The detection limits are 1.0 and 1.5 ng/mL with the linear ranges of 2.5-250 ng/mL for quantitative detection of R-IgG and H-IgM, respectively. The total assay time is around 25 minutes. Such multiplex electrochemical immunoassay could be readily highly multiplexed to allow simultaneous parallel detection of numerous proteins and is expected to open new opportunities for protein diagnostics and biosecurity.

59 BASIC BIOLOGICAL SCIENCES↗

Natural convection in metal foam strips with internal heat generation

Natural convection heat transfer in metal foam strips, with internal heat generation, was investigated experimentally for two porosities. An estimate of the non-equilibrium temperature distribution was done by image processing of the thermal maps on both the surface and the inner region of the metal foam specimen. It was shown that heat transfer at natural convection in the strip of metal foam was increased drastically (up to 18-20 times for metal foam of 20 ppi) relative to the flat plate of the same overall dimensions. The heat transfer from ligaments of metal foam was estimated. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanical and microstructural characterization of 6061 aluminum alloy strips severely deformed by Dissimilar Channel Angular Pressing

Dissimilar Channel Angular Pressing (DCAP) is a severe plastic deformation technique to improve the mechanical properties of flat products by producing ultrafine grains. In this study, the changes in the microstructure and mechanical properties of 6061 Al-alloy strips deformed by various numbers of DCAP passes were investigated. Some DCAPed samples were also held at 200 deg. C and 350 deg. C to investigate the effect of post-annealing. Mechanical properties were determined by hardness and tension tests; and microstructural changes were investigated by TEM analysis. Up to a critical level of plastic strain, remarkable improvements have been observed in the strength and hardness of the severely deformed strips; and the improvements have been explained by variations in grain size, dislocation structure, and formation of subgrains. - Research Highlights: {yields}Dissimilar Channel Angular Pressing (DCAP). {yields}Severe plastic deformation (SPD). {yields}Transmission Electron Microscopy of the 6061 Al alloy. {yields}Mechanical Properties of 6061 Al alloy.

36 MATERIALS SCIENCE↗

Synthesis of carboxyl-capped and bright YVO{sub 4}:Eu,Bi nanoparticles and their applications in immunochromatographic test strip assay

Graphical abstract: - Highlights: • The morphology and properties of YVO{sub 4}:Eu,Bi nanoparticles were investigated. • YVO{sub 4}:Eu,Bi were coupled with IgG for bioprobes due to their good properties. • YVO{sub 4}:Eu,Bi were applied to immunochromatographic test strip assay. - Abstract: Carboxyl-capped YVO{sub 4}:Eu,Bi nanoparticles with average diameter of ∼10 nm were synthesized via a copolymer of phosphono and carboxylic acid mediated hydrothermal method. Under a 350 nm ultraviolet light excitation, the YVO{sub 4}:Eu,Bi NPs exhibit sharp and bright red emission peaked at 615 nm and with highest quantum yield of ∼43%. Furthermore, the nanoparticles show good water/buffer stability and feasible bioconjugation benefiting from the carboxylic groups on their surface. Based on these kind optical and surface properties of the YVO{sub 4}:Eu,Bi nanoparticles, an immunochromatographic test strip assay for quantitative determination of human IgG was achieved. This protocol can be extended to other rare-earth nanoparticles with the purpose of developing bioprobes for desired applications.

36 MATERIALS SCIENCE↗

Time and position resolution of the scintillator strips for a muon system at future colliders

In this study, prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signals from fluorescent materials on the surface of silicon micro-strip sensors

For the High-Luminosity Upgrade of the Large Hadron Collider at CERN, the ATLAS Inner Detector will be replaced with a new, all-silicon tracker (ITk). In order to minimise the amount of material in the ITk, circuit boards with readout electronics will be glued onto the active area of the sensor. Several adhesives, investigated to be used for the construction of detector modules, were found to become fluorescent when exposed to UV light. These adhesives could become a light source in the high-radiation environment of the ATLAS detector. The effect of fluorescent material covering the sensor surface in a high-radiation environment has been studied for a silicon micro-strip sensor using a micro-focused X-ray beam. By positioning the beam parallel to the sensor surface and pointing it both inside the sensor and above the sensor surface inside the deposited glue, the sensor responses from direct hits and fluorescence can be compared with high precision. This contribution presents a setup to study the susceptibility of silicon strip sensors to light contamination from fluorescent materials and shows their impact on the noise and fake signal rate of a sensor operated in a high-radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation tolerance study on irradiated AC-coupled, poly-silicon biased, p-on-n silicon strip sensors developed in India

The silicon sensors to be deployed in the next generation high energy physics experiments for operation in high luminosity scenarios, will require a high level of radiation tolerance. AC-coupled silicon strip sensors integrated with biasing poly-silicon resistors have been fabricated in collaboration with the Bharat Electronics Limited foundry using 4 inch n-type wafers in p-on-n configuration. Several sensors were irradiated with protons at different fluences at the Karlsruhe Cyclotron facility under the Advanced European Infrastructures for Detectors at Accelerators (AIDA) program. This paper reports on these radiation hardness study performed on the AC-coupled silicon sensors fabricated in India. The characterization comprises of electrical tests, including total current, voltage and strip scans and charge collection studies.

AC-coupled↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of dissolved organic matter in landfill leachate during the combined treatment process of air stripping, Fenton, SBR and coagulation

Highlights: • DOM fractions spectra analysis during the whole treatment process. • Efficient method was achieved to remove organic matters in landfill leachate. • Molecular weight distribution and fractions were discussed. - Abstract: A combined treatment process of air stripping + Fenton + sequencing batch reactor (SBR)+ coagulation was performed to remove the pollutants in landfill leachate. Molecular weight (MW) distribution and fractions of dissolved organic matter (DOM) were discussed to study the characteristics. The experiment showed that the removal rate of chemical oxygen demand (COD), five day biological oxygen demand (BOD{sub 5}) and ammonia nitrogen (NH{sub 3}−N) by the combined process were 92.8%, 87.8% and 98.0%, respectively. Humic acid (HA) and fulvic acid (FA) were the main fractions in raw leachate with 81.8% of the total COD concentration, while hydrophilic organic matter (HyI) was the dominant fraction in the final effluent of the combined process with 63.5% of the total COD concentration. After the combined treatment process, the removal rate of DOM and fractions HA, FA, HyI were 91.9%, 97.1%, 95.8% and 71.7%, respectively. Organic matters of MW < 2 k and MW > 100 k were removed with 90.5% and 97.9% COD concentration after the treatment. The ultraviolet–visible spectra (UV–vis), Fourier transform infrared spectra (FTIR) and three-dimensional excitation-emission matrices spectra (EEMs) indicated that benzene materials and phenol compounds were preferentially removed in air stripping. High MW matters, aromatic rings, conjugated moieties and some functional groups were mainly removed by Fenton. While small MW fractions, carboxylic acids, alcohols and protein-like materials were preferentially biodegraded via SBR. Fulvic-like and humic-like materials were mainly destroyed via Fenton oxidation and coagulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents

An integrated lateral flow test strip with electrochemical sensor (LFTSES) device with rapid, selective and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of post-exposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with detection limit of 0.02 nM. Based on this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values, but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding the initial stages of reversible Mg deposition and stripping in inorganic nonaqueous electrolytes

Multivalent (MV) battery architectures based on pairing a Mg metal anode with a high-voltage (~3 V) intercalation cathode offer a realistic design pathway toward significantly surpassing the energy storage performance of traditional Li-ion-based batteries, but there are currently only few electrolyte systems that support reversible Mg deposition. Using both static first-principles calculations and ab initio molecular dynamics, we perform a comprehensive adsorption study of several salt and solvent species at the interface of Mg metal with an electrolyte of Mg 2+ and Cl–dissolved in liquid tetrahydrofuran (THF). Our findings not only provide a picture of the stable species at the interface but also explain how this system can support reversible Mg deposition, and as such, we provide insights in how to design other electrolytes for Mg plating and stripping. Furthermore, the active depositing species are identified to be (MgCl) + monomers coordinated by THF, which exhibit preferential adsorption on Mg compared to possible passivating species (such as THF solvent or neutral MgCl 2 complexes). We found that upon deposition, the energy to desolvate these adsorbed complexes and facilitate charge transfer is shown to be small (~61–46.2 kJ mol –1 to remove three THF from the strongest adsorbing complex), and the stable orientations of the adsorbed but desolvated (MgCl) + complexes appear to be favorable for charge transfer. Lastly, observations of Mg–Cl dissociation at the Mg surface at very low THF coordinations (0 and 1) suggest that deleterious Cl incorporation in the anode may occur upon plating. In the stripping process, this is beneficial by further facilitating the Mg removal reaction.

25 ENERGY STORAGE↗

Evolution at the Solid Electrolyte/Gold Electrode Interface during Lithium Deposition and Stripping

Quasi-binary thiophosphate-based solid electrolytes (SEs) are attracting substantial interest for lithium batteries due to their outstanding room temperature ionic conductivities. This work describes reactions occurring at the solid electrolyte (SE)/Au interface during Li deposition and stripping for two exemplary SE materials: β-Li 3 PS 4 (β-LPS) and Li 10 GeP 2 S 12 (LGPS). We used in situ Raman spectroscopy, along with X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) to evaluate potential-dependent changes in the chemistry of these materials at active electrode interfaces. For β-LPS, a partially reversible conversion of PS 4 3– to P 2 S 6 4– was found along with the formation of Li2S during Li deposition and stripping. In contrast, LGPS exhibited only irreversible changes at potentials below 0.7 V vs Li + /Li. The different behaviors likely relate to differences in the structures of the two SE materials and the availability of easily bridged anion components in close proximity. In conclusion, the work shows that SE integrity at interfaces can be altered by applied potential and illustrates important speciations for the interfacial structures that mediate their electrochemical activities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Passivation dynamics in the anisotropic deposition and stripping of bulk magnesium electrodes during electrochemical cycling

Rechargeable magnesium (Mg) batteries show promise for use as a next generation technology for high-density energy storage, though little is known about the Mg anode solid electrolyte interphase and its implications for the performance and durability of a Mg-based battery. We explore in this report passivation effects engendered during the electrochemical cycling of a bulk Mg anode, characterizing their influences during metal deposition and dissolution in a simple, nonaqueous, Grignard electrolyte solution (ethylmagnesium bromide, EtMgBr, in tetrahydrofuran). Scanning electron microscopy images of Mg foil working electrodes after electrochemical polarization to dissolution potentials show the formation of corrosion pits. The pit densities so evidenced are markedly potential-dependent. When the Mg working electrode is cycled both potentiostatically and galvanostatically in EtMgBr these pits, formed due to passive layer breakdown, act as the foci for subsequent electrochemical activity. Detailed microscopy, diffraction, and spectroscopic data show that further passivation and corrosion results in the anisotropic stripping of the Mg {0001} plane, leaving thin oxide-comprising passivated side wall structures that demark the {0001} fiber texture of the etched Mg grains. Upon long-term cycling, oxide side walls formed due to the pronounced crystallographic anisotropy of the anodic stripping processes, leading to complex overlay anisotropic, columnar structures, exceeding 50 μm in height. Finally, the passive responses mediating the growth of these structures appear to be an intrinsic feature of the electrochemical growth and dissolution of Mg using this electrolyte.

36 MATERIALS SCIENCE↗