Search NASA⌕ Search

SEARCH · Search NASA

Results for “Structured scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

Low-energy cross-section measurement of the B 10 ( α , n ) N 13 reaction and its impact on neutron production in first-generation stars

Nucleosynthesis in the first generation of massive stars offers a unique setting to explore the creation of the first heavier nuclei in an environment free of impurities from earlier stellar generations. In later generations of massive stars, hydrogen burning occurs predominantly through the CNO cycles, but without the carbon, nitrogen, and oxygen to catalyze the reaction sequence, first stars would have to rely on the inefficient pp chains for their energy production. Observations of second and third generation stars show pronounced abundances of carbon and oxygen isotopes, which suggests a rapid conversion of the primordial abundances to heavier elements. While the triple-alpha-process primarily facilitates this conversion, there are alternative reaction sequences, such as 2 H(α,γ) 6 Li(α,γ) 10 B(α,n) 13 N, that may play a significant role. To study such alternate reaction pathways for production of carbon and heavier nuclei, a number of new measurements are needed. In this work, new measurements are reported for the 10 B(α,n) 13 N reaction, extending the cross section down to 575 keV incident α-particle energy. The measurements were made using a state-of-the-art deuterated liquid scintillator and a spectrum unfolding technique. An R-matrix analysis was performed in order to facilitate a comparison of the underlying nuclear structure with the reaction measurements. An unexpected upturn is observed in the low-energy S factor that indicates the presence of a new low-energy resonance. Finally, a revised reaction rate is determined that takes into account the present data as well as other previous measurements from the literature that were previously neglected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel method for modeling the neutron time of flight (nTOF) detector response in current mode to inertial confinement fusion experiments.

There are several machines in this country that produce short bursts of neutrons for various applications. A few examples are the Z machine, operated by Sandia National Laboratories in Albuquerque, NM ; the OMEGA Laser Facility at the University of Rochester in Rochester, NY ; and the National Ignition Facility (NIF) operated by the Department of Energy at Lawrence Livermore National Laboratory in Livermore, California . They all incorporate neutron time of flight (nTOF) detectors which measure neutron yield, and the shapes of the waveforms from these detectors contain germane information about the plasma conditions that produce the neutrons. However, the signals can also be %E2%80%9Cclouded%E2%80%9D by a certain fraction of neutrons that scatter off structural components and also arrive at the detectors, thereby making analysis of the plasma conditions more difficult. These detectors operate in current mode - i.e., they have no discrimination, and all the photomultiplier anode charges are integrated rather than counted individually as they are in single event counting. Up to now, there has not been a method for modeling an nTOF detector operating in current mode. MCNP PoliMi was developed in 2002 to simulate neutron and gamma ray detection in a plastic scintillator, which produces a collision data output table about each neutron and photon interaction occurring within the scintillator; however, the post processing code which accompanies MCNP PoliMi assumes a detector operating in single event counting mode and not current mode. Therefore, the idea for this work had been born: could a new post processing code be written to simulate an nTOF detector operating in current mode? And if so, could this process be used to address such issues as the impact of neutron scattering on the primary signal? Also, could it possibly even identify sources of scattering (i.e., structural materials) that could be removed or modified to produce %E2%80%9Ccleaner%E2%80%9D neutron signals? This process was first developed and then applied to the axial neutron time of flight detectors at the Z Facility mentioned above. First, MCNP PoliMi was used to model relevant portions of the facility between the source and the detector locations. To obtain useful statistics, variance reduction was utilized. Then, the resulting collision output table produced by MCNP PoliMi was further analyzed by a MATLAB postprocessing code. This converted the energy deposited by neutron and photon interactions in the plastic scintillator (i.e., nTOF detector) into light output, in units of MeVee%D1%84 (electron equivalent) vs time. The time response of the detector was then folded into the signal via another MATLAB code. The simulated response was then compared with experimental data and shown to be in good agreement. To address the issue of neutron scattering, an %E2%80%9CIdeal Case,%E2%80%9D (i.e., a plastic scintillator was placed at the same distance from the source for each detector location) with no structural components in the problem. This was done to produce as %E2%80%9Cpure%E2%80%9D a neutron signal as possible. The simulated waveform from this %E2%80%9CIdeal Case%E2%80%9D was then compared with the simulated data from the %E2%80%9CFull Scale%E2%80%9D geometry (i.e., the detector at the same location, but with all the structural materials now included). The %E2%80%9CIdeal Case%E2%80%9D was subtracted from the %E2%80%9CFull Scale%E2%80%9D geometry case, and this was determined to be the contribution due to scattering. The time response was deconvolved out of the empirical data, and the contribution due to scattering was then subtracted out of it. A transformation was then made from dN/dt to dN/dE to obtain neutron spectra at two different detector locations.

Nelson, Alan J.↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The veto system of the DarkSide-50 experiment

Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ce{sup 3+} activated LaBr{sub 3-x}I{sub x}: High-light-yield and fast-response mixed halide scintillators

Here, we report the scintillation properties of LaBr{sub 3-x}I{sub x}:5%Ce{sup 3+} with four different compositions of x, i.e., x=0.75, 1.5, 2, and 2.25. Radioluminescence spectra reveal a shift of the emission wavelength with the LaBr{sub 3} to LaI{sub 3} ratio. LaBr{sub 1.5}I{sub 1.5}:5%Ce{sup 3+} shows the highest scintillation light yield of 58 000 photons/MeV, whereas LaBr{sub 0.75}I{sub 2.25}:5%Ce{sup 3+} shows the fastest scintillation decay time of 12 ns under 662 keV {gamma}-ray excitation. This decay time is faster than that of 16 ns in LaBr{sub 3}:Ce{sup 3+}. The temperature dependence of radioluminescence spectra is presented. The structures and lattice parameters of the materials were determined from powder x-ray diffraction.

36 MATERIALS SCIENCE↗

Descattering of giant pulses in PSR B1957+20

The interstellar medium scatters radio waves, which causes pulsars to scintillate. For intrinsically short bursts of emission, the observed signal should be a direct measurement of the impulse response function. We show that this is indeed the case for giant pulses from PSR B1957+20: from baseband observations at 327 MHz, we demonstrate that the observed voltages of a bright pulse allow one to coherently descatter nearby pulses. We find that while the scattering timescale is 12.2 μs, the power in the descattered pulses is concentrated within a span almost two orders of magnitude shorter, of ≲200 ns. This sets an upper limit to the intrinsic duration of the giant pulses. We verify that the response inferred from the giant pulses is consistent with the scintillation pattern obtained by folding the regular pulsed emission, and that it decorrelates on the same timescale, of 84 s. In principle, with large sets of giant pulses, it should be possible to constrain the structure of the scattering screen much more directly than with other current techniques, such as holography on the dynamic spectrum and cyclic spectroscopy.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence for regions of negligible cosmic-ray modulation in the inner heliosphere ( 10 AU)

Gold and Venkatesan report observations of periods during 1974-1976 when extended regions of heliolongitude that emitted lower than average solar wind velocities at 1 AU also exhibited higher than average cosmic ray intensities as measured by the E 35 MeV CPME anti-coincidence scintillator (28 sq cm omnidirectional geometric factor) on IMP-8. Their observations reproduced by a simple model, based on the observed steady solar wind structure, wherein there is little modulation of cosmic rays in the inner heliosphere until they reach the shocked plasma beyond the stream interactions in the outer heliosphere (similar to 5 to 10 AU). Beyond the interaction boundary, the intensity exhibits a constant radial gradient (similar to 2%/AU). The model also offers an explanation for the irregular behavior of the rotation averaged radial gradients observed by inside 10 AU, as well as the significant, but often ephemeral, latitude gradients observed by Voyagers 1 and 2 and IMP-8.

Roelof, E. C.↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Murchison widefield array observations of anomalous variability: a serendipitous night-time detection of interplanetary scintillation

We present observations of high-amplitude rapid (2 s) variability toward two bright, compact extragalactic radio sources out of several hundred of the brightest radio sources in one of the 30{sup ∘}×30{sup ∘} Murchison Widefield Array (MWA) Epoch of Reionization fields using the MWA at 155 MHz. After rejecting intrinsic, instrumental, and ionospheric origins we consider the most likely explanation for this variability to be interplanetary scintillation (IPS), likely the result of a large coronal mass ejection propagating from the Sun. This is confirmed by roughly contemporaneous observations with the Ooty Radio Telescope. We see evidence for structure on spatial scales ranging from <1000 to >10{sup 6} km. The serendipitous night-time nature of these detections illustrates the new regime that the MWA has opened for IPS studies with sensitive night-time, wide-field, low-frequency observations. This regime complements traditional dedicated strategies for observing IPS and can be utilized in real-time to facilitate dedicated follow-up observations. At the same time, it allows large-scale surveys for compact (arcsec) structures in low-frequency radio sources despite the 2{sup ′} resolution of the array.

79 ASTRONOMY AND ASTROPHYSICS↗

Crystal Growth, Optical and Scintillation Properties of Eu 2+ -doped TlSr 2 Br 5

Crystals of undoped and Eu 2+ -doped TlSr 2 Br 5 of up to 16 mm in diameter and 50 mm in length were grown by the Vertical Bridgman technique. TlSr 2 Br 5 has the monoclinic crystal structure with space group P21/c. Its density and Z eff are 5.03 g/cm 3 and 58.6, respectively. Radioluminescence spectra of undoped and Eu 2+ -doped TlSr 2 Br 5 feature a broad emission band peaking at about 440 nm for undoped and 520 nm for Eu 2+ -doped crystals. The light yield of undoped TlSr 2 Br 5 is 42,000 ph/MeV, which increases to 55,000 ph/MeV for Eu 2+ -doped crystals. The energy resolution at 662 keV ( 137 Cs) is about 5 – 6% (FWHM). As a result, the scintillation decay of undoped and Eu 2+ -doped TlSr 2 Br 5 is of the order of 100s of nanoseconds.

Bridgman technique↗

Recent results from the MINERvA experiment

MINERvA is a dedicated neutrino-nucleus scattering experiment with multiple nuclear targets in the Neutrinos from the Main Injector (NuMI) beam line at Fermilab. MINERvA can provide high precision measurements of neutrino interaction cross sections in the 1 to 20 GeV energy range in support to current and future oscillation experiments. MINERvA can also provide information about the structure of protons and neutrons and about the dynamics affecting neutrino-nucleus interactions. The heart of the MINERvA detector is a fine-grained scintillating tracking cham-ber, surrounded by electromagnetic and hadronic calorimeters. Carbon, iron and lead targets are used to study the effect of the nuclear medium on neutrino-induced interactions. In conclusion, this document summarizes the most recent MINERvA results

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear structure analysis using the Orange Spectrometer

Recently, an Orange spectrometer, a focusing iron-free magnetic spectrometer, has been installed at a beam line of the 10 MV Tandem accelerator of the IKP of the University of Cologne. The high efficiency of 15% of 4{pi} for the detection of conversion electrons and the energy resolution of 1% makes the Orange spectrometer a powerful instrument. From the conversion electron spectrum, transition multipolarities can be determined using the so called K to L ratio. In combination with an array of germanium and lanthanum bromide detectors, e{sup -}-{gamma}-coincidences can be performed to investigate the level scheme. Moreover, the very fast lanthanum bromide scintillator with an energy resolution of 3% allows e{sup -}-{gamma} lifetime measurements down to 0.3 ns. A second Orange spectrometer can be added to build the Double Orange Spectrometer for e{sup -}-e{sup -}-coincidences. It is indispensable for lifetime measurements of low intensity or nearby lying transitions as often occur in odd-A and odd-odd nuclei. The capabilities are illustrated with several examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Green and red luminescence in co-precipitation synthesized Pr:LuAG nanophosphor

Pr:LuAG nanophosphor is an effective candidate in magnetic resonance imaging coupled positron emission tomography (MRI-PET) for medical imaging and scintillator applications. LuAG:Pr (0.05, 0.15 mol%) nanoscale ceramic powders were synthesized by co-precipitation method using urea as precipitant. Effect of antisite defect on structure and luminescence behavior was investigated. Pr:LuAG nanoceramic powders are found crystallized in cubic structure by high temperature calcination at 1400 °C and it shows antisite defect. HR-SEM analysis revealed spherically shaped Pr:LuAG nanoceramic particulate powders with ∼100 nm size. By the excitation at 450 nm, Pr:LuAG nanophosphor exhibit green to red luminescence in the wavelength range of 520 to 680 nm, which is originated from multiplet transition of Pr{sup 3+} ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

VUV light collection enhancement with metasurface lenses

Vacuum-ultraviolet (VUV) light has applications in many areas of fundamental research and technology, including high-energy physics (HEP) experiments and especially those based on scintillation of noble elements (xenon and argon).There are persistent challenges associated with the detection of the VUV photons in particle detectors, e.g. strong absorption by structural materials and low detection efficiency of the photosensors.Metasurfaces are relatively novel nano-fabricated devices which offer unprecedented control of light with a wide field of view and diffraction-limited focusing.This contribution will present the first linear metasurface lens operating in the VUV spectral range with the measured diffraction efficiencies above 50%.The design and fabrication processes will be described in detail, as well as the characterization measurements, and possible applications in the HEP experiments will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The University of Chicago cosmic ray electrons and nuclei experiment on the H spacecraft

The University of Chicago instrument on the Heliocentric spacecraft (MEH experiment) will measure the energy spectrum of cosmic electrons in the range 5-400 MeV. In addition, the energy spectra and relative abundances of nuclei from protons to the iron group, with energies ranging from 30 MeV/n to 15 GeV/n, will be determined. Primary scientific objectives involve the study of the long and short term variability of these components as a probe of the structure of the heliosphere. Particles are identified by multiparameter analysis using the pulse height analyzed signals from eight active detectors - silicon solid state, plastic and crystal scintillators are solid and gas Cerenkov counters. Data return is optimized by a three level priority logic scheme.

Meyer, P.↗

Structure and luminescence properties of Dy 2 O 3 doped bismuth-borate glasses

In this study heavy bismuth-borate glasses were studied as host matrices of Dy 2 O 3 rare earth, for potential application as scintillator materials in high energy physics experiments and in general radiation detection systems. Glass matrices were prepared from 20BaO-xBi 2 O 3 -(80-x)B 2 O 3 (x = 20, 30, 40 mol%) ternary systems and synthesized by the melt-quenching method at different temperatures in order to obtain high density and high transparency in the UV/Vis range. Particularly, the glass manifesting the higher transparency and with sufficiently high density was doped with Dy 2 O 3 (2.5 and 5 mol%) in order to induce the luminescence characteristics. The effects of Bi 2 O 3 and Dy 2 O 3 on density, thermal behaviour, transmission as well as luminescence properties under UV excitation, were investigated. The experimental results show that the synthesized glasses can be considered promising candidate materials as dense scintillators, due to the Dy 3 + centres emission.

36 MATERIALS SCIENCE↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗