Search NASA⌕ Search

SEARCH · Search NASA

Results for “Superfluidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A small helium-cooled infrared telescope for Spacelab 2

A helium cooled telescope of 15 cm aperture is being designed and constructed jointly by the University of Arizona, the Smithsonian Astrophysical Observatory and the Marshall Space Flight Center for high sensitivity infrared astronomical observations from Spacelab 2. A focal plane array of ten detectors provide a total field of view of 3 deg and cover the wavelength regions 4.5-8.5, 6-7, 9-16, 18-30 and 80-120 microns. A highly redundant all sky survey will be conducted by repeated scanning of the sky during many orbits of the spacecraft. High redundancy will allow discrimination among variable and constant celestial sources and several types of variable nearby sources. The principal astronomical result of the survey will be the absolute flux measurement of low surface brightness, large scale celestial infrared emissions but it will also extend existing IR sky surveys by a factor of 10 in point source sensitivity. The experiment will also make significant engineering measurements of contaminants in the Shuttle environment, test the technology of storage and utilization of large quantities of superfluid helium in space and test mechanical designs for future infrared telescopes for the Space Shuttle.

Gautier, T. N., III↗

Second sound shock waves and critical velocities in liquid helium 2

Large amplitude second-sound shock waves were generated and the experimental results compared to the theory of nonlinear second-sound. The structure and thickness of second-sound shock fronts are calculated and compared to experimental data. Theoretically it is shown that at T = 1.88 K, where the nonlinear wave steepening vanishes, the thickness of a very weak shock must diverge. In a region near this temperature, a finite-amplitude shock pulse evolves into an unusual double-shock configuration consisting of a front steepened, temperature raising shock followed by a temperature lowering shock. Double-shocks are experimentally verified. It is experimentally shown that very large second-sound shock waves initiate a breakdown in the superfluidity of helium 2, which is dramatically displayed as a limit to the maximum attainable shock strength. The value of the maximum shock-induced relative velocity represents a significant lower bound to the intrinsic critical velocity of helium 2.

Turner, T. N.↗

A review of the NASA/OAST cryogenic coolers technology program

Low and ultra low temperature cryogenic cooler systems for future space missions include mechanical, solid cryogen, gas adsorption, superfluid helium, helium-3, and magnetic (adiabatic demagnetization) coolers. Operating lifetimes required vary from a few weeks for a Shuttle/Spacelab mission to as long as nine years for missions to the outer planets. Temperature requirements vary from tens to tenths of kelvin. At the higher temperature, cooling loads for detectors, instruments and associated shields may be as high as 15 watts. The general requirements for low and ultra low temperature and techniques that can be employed to achieve these temperatures at expected heat loads are discussed. The NASA Centers involved in the R & T efforts and the type of cooler systems on which they are focusing their effort are considered as well as the thrust of R & T effort for each cooler type. Projected missions that will use the technology are identified.

Lundholm, J. G., Jr.↗

Infrared telescope on Spacelab 2

The infrared telescope (IRT) on Spacelab 2 which will be the first cryogenically cooled telescope operated from the Orbiter is discussed. Its objectives are to measure the induced environment about the Orbiter and to demonstrate the ability to manage a large volume of superfluid helium in space. The prime astrophysical objectives are to map extended sources of low surface brightness infrared emission, including the zodiacal light, the galactic plane, and extragalactic regions. The IRT design is described, including the f/4 15.2 cm highly baffled Herschelian telescope cooled to 8 K which may scan to within 35 deg of the sun. The focal plane cooled to 3 K consists of nine discrete photoconductors covering the wavelength of 4.5-120 microns in five bands, with a single stellar detector used for aspect determination. Overlapping scans, contiguous orbits, and a six degree per second scan rate permit rapid redundant coverage of 60 % of the sky.

Koch, D.↗

Design alternatives for the Shuttle Infrared Telescope Facility

The paper discusses the Shuttle Infrared Telescope Facility (SIRTF), a versatile astronomical telescope that can accomodate photometric, spectroscopic, and polarimetric measurements. It is expected to be 100 to 1000 times more sensitive than any existing infrared telescope; detailed designs of cooled IR telescopes were made for the Infrared Astronomical Satellite and the Small Helium Cooled Infrared Telescope for Spacelab 2. Rocket tests verified the capability of using superfluid helium as a cryogen in zero gravity. Constraints on funds for Shuttle payloads require an evolutionary approach to the development of the full potential of SIRTF, necessitating consideration of design alternatives involving the optical configuration, the cryogen, the mechanical structure, and size of SIRTF.

Witteborn, F. C.↗

NASA low and ultralow temperature cryogenic cooler systems for space missions

The paper describes the NASA research program to provide low and ultralow temperature cryogenic cooler systems for future space missions. These include mechanical, solid cryogen, superfluid helium, helium-3, and helium-3/helium-4 dilution coolers, and all systems must function in the zero gravity environment of space. The temperatures produced range from tens of kelvin down to a few millikelvin; at higher temperatures cooling loads for sensors or detectors and associated sun shields may range up to a few watts. At the ultralow temperature end, cooling loads must be limited to tens of microwatts.

Lundholm, J. G., Jr.↗

Thermal design of a Shuttle infrared telescope facility /SIRTF/

A thermal design concept has been developed for a cryogenically-cooled infrared telescope facility which will be carried aboard the Space Shuttle for missions of 14 to 30 days. Supercitical helium at 6 K is the principal coolant. Auxiliary tanks of superfluid helium at 2 K are utilized to provide additional low-temperature cooling requirements of specific instruments. The preliminary thermal design described enables SIRTF to provide the low-temperature environment for the telescope and instruments, while maintaining thermally-induced optical degradations within acceptable limits with a cryogen utilization rate compatible with weight and volumetric constraints.

Stoll, R.↗

Observations of homogeneous phase separation in liquid He3-He4 mixtures

The so-called miscibility gap that exists below the critical point in liquid He-3 - H-4 mixtures makes it possible to study binary phase composition, and the ensuing dispersions, in a system possessing an additional order parameter in one of the components. The physical behavior of a superfluid dispersion produced by pressure quenching an He-3 - He-4 mixture into the miscibility gap is described. The description applies both to quenches of homogeneous and phase-separated initial states in various regions of the miscibility gap.

Hoffer, J. K.↗

Low cost cryostat

A cryostat for use in a low or a substantially gravity-free environment adapted to cool an experiment through the use of helium 2, or helium in its super fluid state is characterized by a number of interchangeable daughter dewars and helium supply or mother dewar. A low pressure venting system is provided for converting helium contained in the mother dewar to a superfluid state for use as a primary cryogen. Each daughter dewar is adapted to be removably mounted in mated relation on the mother dewar and is characterized by support for an experiment package, a source of helium to be employed as a secondary cryogen. A heat pipe is suspended from each daughter dewar and adapted to be extended into the mother dewar for facilitating cooling of the secondary cryogen. A transfer of heat from the package to the primary cryogen, via the secondary cryogen, is accommodated as a film flow of helium 2 progresses from the heat pipe to the experiment dewar.

Stephens, J. B.↗

Mapping the infrared background radiation from the Shuttle

The Spacelab-2 Small Helium-Cooled Infrared Telescope will be used to map extended astronomical sources of low surface brightness emission, to measure the Shuttle induced environment and to develop techniques for managing large volumes of superfluid helium in space. The instrument is an f/4 15.2-cm Herschelian telescope with ten photoconductor detectors in the focal plane. This paper describes the hardware and software aspects of the instrument with emphasis on mission operations. In particular, a description is given of the observing plan formulated to meet the scientific and engineering objectives, the scan drive system, the precautions in design and operation necessary to prevent the sun, moon, and earth from adversely affecting the observations, the implications of thruster firings, and the on-board experiment computer application software to control the scanning of the telescope and support on-board displays.

Koch, D.↗

Preliminary cryogenic performance of the Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope Facility (SIRTF) is a cryogenically cooled telescope in the one-meter aperture class designed for sensing in the infrared from 2-200 microns. This facility is designed to be flown many times on the Space Shuttle with varying instrument complements. All components of the SIRTF within the field of view of the optics are cryogenically cooled. The primary coolant is supercritical helium which is stored in an external tank and routed through the telescope - cooling the instruments first, then the optical components and finally the baffles. For detector cooling below 6K small reservoirs of superfluid helium (He II) are provided. The SIRTF cryogenic system is designed to automatically control the tank pressure and telescope flow rates during prelaunch operations and flight as well as meet the Space Shuttle environmental and safety requirements. Temperatures maintained in the telescope are a function of instrument operation, design, energy dissipation, and telescope pointing angle. By control of the cryogen flow rate any selected instrument temperature can be maintained within fixed limits, and the critical secondary mirror can be maintained below 10K throughout a 14-day mission. Instrument thermal design is a critical factor in the maintenance of proper temperature differences in the experiment package. Design of a cryogenic telescope for space use presents many problems which do not exist in earth based systems. The limited opportunity for servicing, the restricted coolant supply, and the remote instrumentation and control all provide new considerations for the instrument and system designers.

Gier, H. L.↗

Spacecraft Dynamics as Related to Laboratory Experiments in Space

Proceedings are presented of a conference sponsored by the Physics and Chemistry Experiments in Space Working Group to discuss the scientific and engineering aspects involved in the design and performance of reduced to zero gravity experiments affected by spacecraft environments and dynamics. The dynamics of drops, geophysical fluids, and superfluid helium are considered as well as two phase flow, combustion, and heat transfer. Interactions between spacecraft motions and the atmospheric cloud physics laboratory experiments are also examined.

G. H. Fichtl↗

Spacelab mission 2: Experimental descriptions

The second Spacelab Mission and the 12 multidisciplinary experiments selected to fly on board are described. These experiments include the following: vitamin D metabolities and bone demineralization; interaction of oxygen and gravity influenced lignification; ejectable plasma diagnostics package; plasma depletion experiments for ionospheric and radio astronomical studies; small helium cooled IR telescope; elemental composition and energy spectra of cosmic ray nuclei; hard X-ray imaging of clusters of galaxies and other extended X-ray sources; solar magnetic and velocity field measurement system; solar coronal helium abundance Spacelab experiment; solar UV high resolution telescope and spectroraph; solar UV spectral irradiance monitor; and properties of superfluid helium in zero-G.

Clifton, K. S.↗

Giant glitches and pinned vorticity in the Vela and other pulsars

Previously unexamined regularities in the Vela pulsar timing data are noted, and explained by a theory of giant glitches in the Vela and other pulsars as the dynamic consequence of catastrophic unpinning events in the pinned crustal neutron superfluid. Postglitch behavior then results from the glitch-induced vortex creep. An implication of the theory is that the energy release in this glitch scenario need not appear instantaneously on the surface as heat.

Alpar, M. A.↗

Neutron star evolutionary sequences

Detailed numerical calculations which are solutions of the full set of general relativistic equations describing the evolution of a spherical star are presented, for the case of the evolution of neutron stars that are cooling over the central temperatures range of 10 to the 10th to 10 to the 7th K. The effects of nucleon superfluidity in the inner crust and core are included, and models are constructed with and without a pion condensate at high densities. It is found that the localized neutrino cooling which dominates the early evolution of neutron stars is so rapid that heat transport within the star cannot keep pace, and temperature distribution is not isothermal. The residual contraction of the neutron star during the early cooling phase contributes little to the heat budget of the star, and most of the gravitational energy released raises the Fermi energy of the degenerate nucleons. It is concluded that since calculations with and without pion condensate are consistent with the upper limits of current observations, these are not sufficient in distinguishing between the various models of neutron star cooling.

Richardson, M. B.↗

Electrostriction in liquid He-4

The two-fluid model of liquid He-4 is extended to include effects of applied electric fields. New terms that account for electrostriction in equations of motion for superfluid and normal fluid are derived with the aid of a variational principle subject to the assumption that the Clausius-Mossotti relation for the dielectric constant is applicable. Corresponding additions to conservation laws for momentum and energy are presented.

Jackson, H. W.↗

Investigation Development Plan for Reflight of the Small Helium-cooled Infrared Telescope Experiment. Volume 1: Investigation and Technical/management

The Infrared Telescope (IRT) is designed to survey extended celestial sources of infrared radiation between 4 and 120 micrometers wavelength. It will provide data regarding Space Shuttle induced environmental contamination and the zodical light. And, it will provide experience in the management of large volumes of superfluid helium in the space environment.

Source record↗

Ordered pairing in liquid metallic hydrogen

We study two possible types of pairing involving the protons of a proposed low-temperature liquid phase metallic hydrogen. Electron-proton pairing, which can result in an insulating phase, is investigated by using an approximate solution of an Eliashberg-type equation for the anomalous self-energy. A very low estimate of the transition temperature is obtained by including proton correlations in the effective interaction. For proton-proton pairing, we derive a new proton pair potential based on the Abrikosov wave function. This potential includes the electron-proton interaction to all orders and has a much larger well depth than is obtained with linear screening methods. This suggests the possibility of either a superfluid paired phase analogous to that in He-3, or alternatively a phase with true molecular pairing.

Carlsson, A. E.↗