Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Results for the Fourth Quarter 2012 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2012 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC).1 Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: The concentration of the reported chemical and radioactive contaminants were less than their respective WAC Limits and Targets, unless noted in this section. Norpar 13 and Isopar L have higher detection limits 5 compared with the Saltstone WAC 1 . The data provided in this report is based upon the concentrations in the sub-sample, and due to the limited solubility in aqueous solution, may not represent the concentrations of the analytes in Tank 50. Diisooctyl adipate (or diisooctyl hexanedioate) was measured at 1.30E+00 mg/L in one of two replicate measurements conducted on an at-depth sample. a The organic analysis of the at-depth sample was conducted at the request of SRR. 4 This analyte was below the detection limit in the surface sample. The low insoluble solids content increases the measurement uncertainty for insoluble species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of structural defects on optical properties of In x Ga 1-x N layers and quantum wells

This review concentrates on the microstructure of In x Ga 1-x N layers and quantum wells (QWs) in relation to their optical properties. The microstructure of In x Ga 1-x N, with a constant In(x) concentration, shifts with layer thickness. Only layers below 100 nm for x = 0.1 are nearly defect-free. A photoluminescence peak is observed at 405 nm, in line with ~10% In, suggesting band-edge luminescence. Layers with greater thickness and In content present a corrugated surface with numerous structural defects, including V-defects, causing redshifts and multi-peaks in photoluminescence up to 490 nm. These defects, resembling those in GaN, lead to a corrugated sample surface. Atomic force microscopy shows a 3.7-fold larger corrugation in samples with 20 QWs compared to those with 5 QWs measured on 2 × 2 μm 2 areas. Like in GaN, dual growth on different crystallographic planes results in varied QW thicknesses, influencing optical traits of devices made from In x Ga 1-x N layers. The purpose of this review and the chosen subject is to highlight the significant contribution of Wladek Walukiewicz and his group to the current research on the properties of In x Ga 1-x N, which are crucial alloys in the field of optoelectronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superhydrophobic Analyte Concentration Utilizing Colloid-Pillar Array SERS Substrates

In order to detect a few molecules present in a large sample it is important to know the trace components in the medicinal and environmental sample. Surface enhanced Raman spectroscopy (SERS) is a technique that can be utilized to detect molecules at very low absolute numbers. However, detection at trace concentration levels in real samples requires properly designed delivery and detection systems. Moreover, the following work involves superhydrophobic surfaces that includes silicon pillar arrays formed by lithographic and dewetting protocols. In order to generate the necessary plasmonic substrate for SERS detection, simple and flow stable Ag colloid was added to the functionalized pillar array system via soaking. The pillars are used native and with hydrophobic modification. The pillars provide a means to concentrate analyte via superhydrophobic droplet evaporation effects. A 100-fold concentration of analyte was estimated, with a limit of detection of 2.9 10-12 M for mitoxantrone dihydrochloride. Additionally, analytes were delivered to the surface via a multiplex approach in order to demonstrate an ability to control droplet size and placement for scaled-up applications in real world applications. Finally, a concentration process involving transport and sequestration based on surface treatment selective wicking is demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface and bulk effects of K in highly efficient Cu 1-x K x InSe 2 solar cells

To advance knowledge of the beneficial effects of K in Cu(In,Ga)(Se,S) 2 (CIGS) photovoltaic (PV) absorbers, recent Cu-K-In-Se phase growth studies have been extended to PV performance. First, the effect of distributing K throughout bulk Cu 1-x K x InSe 2 absorbers at low K/(K+Cu) compositions (0 = x = 0.30) was studied. Efficiency, open-circuit voltage (VOC), and fill factor (FF) were greatly enhanced for x ~ 0.07, resulting in an officially-measured 15.0%-efficient solar cell, matching the world record CuInSe 2 efficiency. The improvements were a result of reduced interface and bulk recombination, relative to CuInSe 2 (x ~ 0). However, higher x compositions had reduced efficiency, short-circuit current density (J SC ), and FF due to greatly increased interface recombination, relative to the x ~ 0 baseline. Next, the effect of confining K at the absorber/buffer interface at high K/(K+Cu) compositions (0.30 = x = 0.92) was researched. Previous work showed that these surface layer growth conditions produced CuInSe 2 with a large phase fraction of KInSe 2 . After optimization (75 nm surface layer with x ~ 0.41), these KInSe 2 surface samples exhibited increased efficiency (officially 14.9%), VOC, and FF as a result of decreased interface recombination. The KInSe 2 surfaces had features similar to previous reports for KF post-deposition treatments (PDTs) used in world record CIGS solar cells - taken as indirect evidence that KInSe 2 can form during these PDTs. Both the bulk and surface growth processes greatly reduced interface recombination. However, the KInSe 2 surface had higher K levels near the surface, greater lifetimes, and increased inversion near the buffer interface, relative to the champion bulk Cu 1-x K x InSe 2 absorber. These characteristics demonstrate that K may benefit PV performance by different mechanisms at the surface and in the absorber bulk.

14 SOLAR ENERGY↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

Off-Equilibrium Reactivity of Boron-Enriched Metal Diboride Surfaces in Electroreduction Conditions

Boron-based materials, featuring B-dependent reactivity and diverse phases, are emerging as promising catalyst systems. However, the catalytic mechanism on many borides remains poorly understood due to complex surface reconstructions under reaction conditions. Here, we investigate the MoB 2 surface in conditions of hydrogen evolution reaction in acidic media, using grand canonical global optimization, grand canonical density functional theory, ab initio molecular dynamics, free energy surface sampling, and an analytical model for electrochemical barrier evaluation. We propose a boron-enrichment strategy to tune the surface reactivity of the hexagonal face of MoB 2 . We reveal the dynamic nature of the B-enriched surface under H coverage and kinetic trapping of the system in the metastable regime with an extensive examination of the deactivation pathways. The metastable center B site on B-enriched surfaces, featuring buckled-up configuration and a usual relaxation effect, is found to be highly active toward HER via the Volmer–Heyrovsky mechanism. In conclusion, this work demonstrates how off-equilibrium behaviors can arise from the interplay between adsorbate coverage and surface reconstruction on a seemingly simple surface, and we present a theoretical framework and computational workflows to address these behaviors, along with other realistic complexities, in kinetics simulations.

Adsorption↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

X-ray quantification of oxygen groups on diamond surfaces for quantum applications

Abstract Identifying the surface chemistry of diamond materials is increasingly important for device applications, especially quantum sensors. Oxygen-related termination species are widely used because they are naturally abundant, chemically stable, and compatible with stable nitrogen vacancy centres near the diamond surface. Diamond surfaces host a mixture of oxygen-related species, and the precise chemistry and relative coverage of different species can lead to dramatically different electronic properties, with direct consequences for near-surface quantum sensors. However, it is challenging to unambiguously identify the different groups or quantify the relative surface coverage. Here we show that a combination of x-ray absorption and photoelectron spectroscopies can be used to quantitatively identify the coverage of carbonyl functional groups on the { 100 } diamond surface. Using this method we reveal an unexpectedly high fraction of carbonyl groups ( > 9%) on a wide range of sample surfaces. Furthermore, through a combination of ab initio calculations and spectroscopic studies of engineered surfaces, we reveal unexpected complexities in the x-ray spectroscopy of oxygen terminated diamond surfaces. Of particular note, we find the binding energies of carbonyl-related groups on diamond differs significantly from other organic systems, likely resulting in previous misestimation of carbonyl fractions on diamond surfaces.

36 MATERIALS SCIENCE↗

Measurement of Dielectric Multipactor Thresholds at 110 GHz

We report experimental measurements of the threshold for multipactor discharges on dielectric surfaces at 110 GHz. Multipactor was studied in two geometries: electric field polarized parallel to or perpendicular to the sample surface. Measured multipactor thresholds ranged from 15 to 34 MV /m, more than 10 times higher than those found at conventional microwave frequencies. Measured thresholds were compared with prior data at lower frequencies, showing agreement with theoretical predictions that thresholds increase linearly with frequency. Measurements of the rf power dissipated in the multipactor show low dissipation (≤ 1%) for the parallel electric field case, but very strong dissipation for the perpendicular case, also in agreement with theoretical predictions. In conclusion, the agreement between experiment and theory over a wide range of frequencies provides a strong basis for the understanding of dielectric multipactor discharges.

43 PARTICLE ACCELERATORS↗

Flexural strength of a conventionally processed and additively manufactured debased 94% alumina

Mechanical strength of a 94 wt% debased alumina was measured using ASTM-C1161 specimens fabricated via conventional and lithography-based ceramic manufacturing (LCM) methods. The effects of build orientation and a 1500°C wet hydrogen fire added to the LCM firing sequence on strength were evaluated. Additionally, a Weibull fit to the conventional flexural specimen data yielded 20 and 356 MPa for the modulus and characteristic strength, respectively. Weibull fits of the data from the LCM specimens yielded moduli between 7.5 and 11.3 and characteristics strengths between 333 and 339 MPa. A Weibull fit to data from LCM specimens subjected to the wet hydrogen fire yielded 14.2 and 376 MPa for the modulus and characteristic strength, respectively. The 95% confidence intervals for all Weibull parameters are reported. Average Archimedes bulk densities of LCM and conventional specimens were 3.732 and 3.730 g/cm 3 , respectively. Process dependent differences in surface morphology were observed in scanning electron microscope (SEM) images of specimen surfaces. SEM images of LCM specimen cross-sections showed alumina grain texture dependent on build direction, but no evidence of porosity concentrated in planes between printed layers. Fracture surfaces of LCM and conventionally processed specimens revealed hackle lines and mirror regions indicative of fracture initiation at the sample surface rather than the interior.

36 MATERIALS SCIENCE↗

Atmospheric-pressure Molecular Imaging of Biological Tissues and Biofilms by LAESI Mass Spectrometry

Ambient ionization methods in mass spectrometry allow analytical investigations to be performed directly on a tissue or biofilm under nativelike experimental conditions. Laser ablation electrospray ionization (LAESI) is one such development and is particularly well-suited for the investigation of water-containing specimens. LAESI utilizes a mid-infrared laser beam (2.94 μm wavelength) to excite the water molecules of the sample. When the ablation fluence threshold is exceeded, the sample material is expelled in the form of particulate matter and these projectiles travel to tens of millimeters above the sample surface. In LAESI, this ablation plume is intercepted by highly charged droplets to capture a fraction of the ejected sample material and convert its chemical constituents into gas-phase ions. A mass spectrometer equipped with an atmospheric-pressure ion source interface is employed to analyze and record the composition of the released ions originating from the probed area (pixel) of the sample. A systematic interrogation over an array of pixels opens a way for molecular imaging in the microprobe analysis mode. A unique aspect of LAESI mass spectrometric imaging is depth profiling that, in combination with lateral imaging, enables threedimensional (3D) molecular imaging. With current lateral and depth resolutions of ~100 μm and ~40 μm, respectively, LAESI mass spectrometric imaging helps to explore the molecular structure of biological tissues. Herein, we review the major elements of a LAESI system and provide guidelines for a successful imaging experiment.

59 BASIC BIOLOGICAL SCIENCES↗

Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

47 OTHER INSTRUMENTATION↗

Constant-Distance Mode Nanospray Desorption Electrospray Ionization Mass Spectrometry Imaging of Biological Samples with Complex Topography

A new approach for constant distance mode mass spectrometry imaging of biological samples using nanospray desorption electrospray ionization (nano-DESI MSI) was developed by integrating a shear-force probe with nano-DESI probe. The technical concept and basic instrumental setup as well as general operation of the system are described. Mechanical dampening of resonant oscillations due to the presence of shear forces between the probe and the sample surface enables constant-distance imaging mode via a computer controlled closed feedback loop. The capability of simultaneous chemical and topographic imaging of complex biological samples is demonstrated using living Bacillus Subtilis ATCC 49760 colonies on agar plates. The constant-distance mode nano-DESI MSI enabled imaging of many metabolites including non-ribosomal peptides (surfactin, plipastatin and iturin) and iron-bound heme on the surface of living bacterial colonies ranging in diameter from 10 mm to 13 mm with height variations of up to 0.8 mm above the agar plate. Co-registration of ion images to topographic images provided higher-contrast images. Constant-mode nano-DESI MSI is ideally suited for imaging biological samples of complex topography in their native state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing physical, chemical, and magnetic properties at the nanoscale

Synchrotron light sources are extremely useful for the characterization of materials in many different research fields (including physics, chemistry, materials science, biology, medicine, geology, and cultural heritage). The evolution of technology, however, currently points toward the miniaturization of devices and molecular motors, as well as the creation (through atomic manipulation) of new materials. This brings an acute necessity for direct chemical imaging of materials, i.e., with the use of x-ray microscopy at the nanometer and atomic length scales.1, 2 Although a variety of new x-ray nanoprobes and x-ray microscopy techniques have been developed in recent years, the spatial resolution of direct chemical or magnetic contrast imaging techniques remains on the order of several nanometers. Invented in the 1980s, scanning tunneling microscopy (STM) allows a large range of materials to be viewed at the atomic level.3 STM also offers a finer degree of spatial resolution than almost any other image technique, but it is chemically ‘blind’ and thus cannot be used alone to directly identify chemical elements on a surface. For many years, researchers have attempted to solve this problem by combining STM with synchrotron x-ray excitations,4–7 and a new technique—known as synchrotron xray scanning tunneling microscopy (SX-STM)—has emerged. In this technique—which combines the chemical sensitivity of xrays with the high spatial resolution of STM—a monochromatic x-ray beam is used to illuminate a tip-sample junction, while the tip makes raster scans across the sample surface. A feedback system maintains a tip–sample separation that is typically less than 1nm. The goal is tomodulate the tunneling current through x-ray excitation and therewith obtain electronic and chemical contrast. It is difficult, however, to achieve real chemical contrast because of three serious issues. First, electrons excited by x-rays do not just tunnel into the tip, but can also be ejected from the sample and hit the sidewalls of the tip detector (which degrades the spatial resolution). Second, because photoejected electrons still provide a deceptive current signal in the far field, the STM feedback system can lift the tip out of the tunneling regime without being noticed. Last, themeasured tip current is always a convolution of the conventional tunnel current (which is related to the sample topography) and the x-ray-excited electrons (which carry the material’s chemical information).

36 MATERIALS SCIENCE↗

Chemical stability of highly (0001) textured Sm(CoCu){sub 5} thin films with a thin Ta capping layer

With the highest magnetocrystalline anisotropy constant (Ku) among practical magnetic materials, SmCo{sub 5} could be a very attractive candidate for future high areal density magnetic recording. However, its corrosion resistance is always a concern in recording media applications. In this paper, the chemical stability and microstructures of highly (0001) textured Sm(CoCu){sub 5} thin films with and without a 3 nm Ta capping layer were reported. For Sm(CoCu){sub 5} thin films without a capping layer, the coercivity decreases significantly (from 8kOe to 1kOe) within one month. Sm(CoCu){sub 5} thin films capped with a thin Ta layer (3 nm) behave differently. Even exposed to a laboratory environment (25 deg. C) over 3 years, the Ta-capped Sm(CoCu){sub 5} thin films are stable in terms of structural and magnetic properties, i.e., there were no changes in X-ray diffraction peaks and vibrating sample magnetometer hysteresis loops. Microstructure of Ta-capped Sm(CoCu){sub 5} thin films showed that Sm(CoCu){sub 5} formed a domelike particle assembly structure on a smooth Ru underlayer and were well covered by partially oxidized Ta capping layer, as shown by TEM cross-section micrographs. Accelerated corrosion treatment (130 deg. C, 95% relative humidity, 6 h) was performed on Ta-capped Sm(CoCu){sub 5} thin films. X-ray photoelectron spectroscopy (XPS) results showed that no Co was detected on the sample surface before the corrosion treatment, but strong XPS signals of CoOx and Co(OH)x were observed after treatment. Therefore, none of our Sm(CoCu){sub 5} thin films can pass the accelerated corrosion test. Hcp-phased CoPt-alloys are proposed as better capping materials for Sm(CoCu){sub 5} thin films in future high-density magnetic recording applications.

36 MATERIALS SCIENCE↗

ARTIFACT FORMATION DURING NEUTRALIZATION OF TANK 50 SAMPLES

Degradation products have been identified in the extracts of Tank 50 samples analyzed by semivolatile organic compound analysis (SVOA) using gas chromatography/mass spectrometry (GC/MS). These materials, identified as short chain alkyl alcohols, were formed by acidification during sample preparation. A number of questions were raised about the formation of these and other materials reported in Tank 50 surface samples, and this report serves to address these questions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental Soil Screening Levels for Cs-137 at University of Washington Medical Center

Current radiological surveys (exposure rate measurements and smear surveys) conducted outside the University of Washington (UW) Harborview Research and Training building found no evidence of Cs-137 contamination in public walk ways, or open areas, and preliminary soil concentrations from samples upwind and downwind of the building were within global fallout levels found in the region. Additional soil and outdoor surface sampling is being considered to more fully assess the possibility of an environmental release during the incident and the radiological impact, if any. This analysis is designed to assist in the evaluation of soil sample results and provide radiation dose-based Soil Screening Levels (SSLs) to help develop sampling and analysis plans and for evaluating these measurements in the context of radiation dose limits. Soil samples could be used to answer two general questions. The first asks if any detected Cs-137 in the soil is above global fallout levels measured in the area. Calculations based on fallout levels from Beck and Bennett (2002) and NCRP 154 suggest that current global fallout levels in Seattle area soil would range up to about 3 pCi/g in undisturbed soils, but there would be large variations based on a variety of transport factors related to the urban environment surrounding the area. Based on the sample result, any measurement significantly above background could prompt additional analysis including looking at the ratio of the Cs-137 to Pu-239/240 to help identify the source of the Cs-137, that is, from global fallout or from the incident. The second question is if there is detectable Cs-137 in the soil, what is the radiological impact of the Cs-137? For this, a dose pathway analysis using the RESRAD model was done to protectively estimate soil-based dose conversion factors and SSLs for Cs-137 in soil.

54 ENVIRONMENTAL SCIENCES↗

Large magnetoresistance and Fermi surface study of Sb 2 Se 2 Te single crystal

Here, we have studied the magnetotransport properties of a Sb 2 Se 2 Te single crystal. Magnetoresistance (MR) is maximum when the magnetic field is perpendicular to the sample surface and reaches a value of 1100% at B = 31 T with no sign of saturation. MR shows Shubnikov de Haas (SdH) oscillations above B = 15 T. The frequency spectrum of SdH oscillations consists of three distinct peaks at α = 32 T, β = 80 T, and γ = 117 T indicating the presence of three Fermi surface pockets. Among these frequencies, β is the prominent peak in the frequency spectrum of SdH oscillations measured at different tilt angles of the sample with respect to the magnetic field. From the angle dependence β and Berry phase calculations, we have confirmed the trivial topology of the β-pocket. The cyclotron masses of charge carriers, obtained by using the Lifshitz–Kosevich formula, are found to be m$*\atop{β}$= 0.16m o and m$*\atop{γ}$= 0.63m o for the β and γ bands, respectively. The Large MR of Sb 2 Se 2 Te is suitable for utilization in electronic instruments such as computer hard discs, high field magnetic sensors, and memory devices.

36 MATERIALS SCIENCE↗