Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEMPERATURE PROFILE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Temperature and EUV Intensity in a Coronal Prominence Cavity and Streamer

We analyze the temperature and EUV line emission of a coronal cavity and surrounding streamer in terms of a morphological forward model. We use a series of iron line ratios observed with the Hinode Extreme-ultraviolet Imaging Spectrograph (EIS) on 2007 Aug. 9 to constrain temperature as a function of altitude in a morphological forward model of the streamer and cavity. We also compare model prediction of the EIS EUV line intensities and polarized brightness (pB) data from the Mauna Loa Solar Observatory (MLSO) MK4. This work builds on earlier analysis using the same model to determine geometry of and density in the same cavity and streamer. The fit to the data with altitude dependent temperature profiles indicates that both the streamer and cavity have temperatures in the range 1.4-1.7 MK. However, the cavity exhibits substantial substructure such that the altitude dependent temperature profile is not sufficient to completely model conditions in the cavity. Coronal prominence cavities are structured by magnetism so clues to this structure are to be found in their plasma properties. These temperature substructures are likely related to structures in the cavity magnetic field. Furthermore, we find that the model overestimates the line intensities by a factor of 4-10, while overestimating pB data by no more than a factor of 1.4. One possible explanation for this is that there may be a significant amount of material at temperatures outside of the range log T(K) approximately equals 5.8 - 6.7 in both the cavity and the streamer.

Kucera, T. A.↗

The validation of AIRS retrievals

The initial validation of Atmospheric Infrared Sounder (SIRS) experiment retrievals were completed in August 2003 as part of public release of version 3.0 data. The associated analyses are reported at http://daac.gsfc.nasa.gov/atmodyn/airs/, where data may be accessed. Here we describe some of those analyses, with an emphasis on cloud cleared radiances, atmospheric temperature profiles, sea surface temperature, total water vapor and atmospheric water vapor profiles. The results are applicable over ocean in the latitude band +/-40 degrees.

meterology↗

Thermostructural Behavior of a Hypersonic Aircraft Sandwich Panel Subjected to Heating on One Side

Thermostructural analysis was performed on a heated titanium honeycomb-core sandwich panel. The sandwich panel was supported at its four edges with spar-like substructures that acted as heat sinks, which are generally not considered in the classical analysis. One side of the panel was heated to high temperature to simulate aerodynamic heating during hypersonic flight. Two types of surface heating were considered: (1) flat-temperature profile, which ignores the effect of edge heat sinks, and (2) dome-shaped-temperature profile, which approximates the actual surface temperature distribution associated with the existence of edge heat sinks. The finite-element method was used to calculate the deformation field and thermal stress distributions in the face sheets and core of the sandwich panel. The detailed thermal stress distributions in the sandwich panel are presented, and critical stress regions are identified. The study shows how the magnitudes of those critical stresses and their locations change with different heating and edge conditions. This technical report presents comprehensive, three-dimensional graphical displays of thermal stress distributions in every part of a titanium honeycomb-core sandwich panel subjected to hypersonic heating on one side. The plots offer quick visualization of the structural response of the panel and are very useful for hot structures designers to identify the critical stress regions.

Ko, William L.↗

Detection of the J-10 Manifold of the Pure Rotational Band of Phosphine on Saturn

The detection of the J = 10 manifold of the pure rotational band of PH3 on Saturn is reported. The observations were made from the far-infrared cooled grating spectrometer. The wavelengths and observed brightness temperatures for the full disk plus rings are 89 + or - 3 K at 97.04 micrometer, 77 + or - 3 K at 102.72 micrometer, 77 + or - 3 K at 102.94 micrometer, and 83 + or - 3 K at 105.12 micrometers. The points of 97.04 and 105.12 micrometers establish the continuum level and the two points near 103 micrometers measure the depth of the PH3 manifold. After the flux due to the rings is subtracted, the depth of the feature is 16 + or - 6 K relative to the nearby 102 K continuum. These results are compared to theoretical models which parameterize the PH3 mixing ratio as x = x sub zero (P/P sub zero)(alpha) for P P sub zero and as x = x sub zero for P or = P, where P is the total pressure and alpha = H/h is the ratio of the dynamical scale height (H) and the scale height for decreasing the PH3 mixing ratio (h). The parameters x sub zero, P sub zero, and h were varied, as well as the H/He mixing ratio and the pressure-temperature profile. The data are well fitted using pressure-temperature profiles. The preferred values of h, P sub zero, and x sub zero imply that there is little or no PH3 above the thermal inversion and that the mixing ratio below the inversion is consistent with PH3 being 1 to 4 times overabundant relative to the solar P/H ratio.

Haas, M. R.↗

Frozen start-up behavior of low-temperature heat pipes

Start-up and subsequent operation of a low-temperature heat pipe requires the liquid phase of the operating fluid to be continuously pumped back to the evaporator by the capillary action of the wick. If the pipe has been in an environment where ambient temperatures are below the freezing point of the working fluid prior to start-up, the frozen fluid in the condenser and adiabatic region scan prevent initial flow to the evaporator, causing dryout of the evaporator before all of the working fluid is in the liquid phase. This paper examines the time-dependent wall and vapor temperature profiles along the axial length of a low-temperature heat pipe during start-up from the frozen state, and freeze-out during a normal operation by applying a subfreezing temperature fluid through the condenser. In addition, the experimental transient frozen start-up wall temperature profile is compared with a two-dimensional numerical phase-change model. A successful start-up method using a pulsed power input is presented.

Faghri, Amir↗

Over-Luminous Elliptical Galaxies

The first paper from our work has been completed and accepted for publication. Another paper presents a study of the ESO 30601 70 galaxy group, combining Chandra, XMM-Newton, and optical observations. We find that the system is a true fossil galaxy group - a group whose optical light is dominated by a single galaxy. The group X-ray emission is composed of a central, dense, cool core (10 kpc in radius) and an isothermal medium beyond the central 10 kpc. The region between 10 and 50 kpc (the cooling radius) has the same temperature as the gas from 50 to 400 kpc, although the gas cooling time between 10 and 50 kpc (2-6 Gyr) is shorter than the Hubble time. Thus, the ESO 3060170 group does not have a group-sized cooling core. We suggest that the group cooling core may have been heated by a central active galactic nucleus (AGN) outburst in the past and that the small, dense, cool core is the truncated relic of a previous cooling core. The Chandra observations also reveal a variety of X-ray features in the central region, including a finger, an edge-like feature, and a small tail, all aligned along a north-south axis, as are the galaxy light and group galaxy distribution. The proposed AGN outburst may cause gas to slosh around the center and produce these asymmetric features. The observed flat temperature profile to 1/3rvir is not consistent with the predicted temperature profile in recent numerical simulations. We compare the entropy profile of the ESO 3060170 group with those of three other groups and find a flatter relation than that predicted by simulations involving only shock heating, S approximately r approximately 0.85. This is direct evidence of the importance of non-gravitational processes in group centers. We derive the mass profiles within 1/3rvir and find that the ESO 3060170 group is the most massive fossil group known.

Forman, William↗

Lunar magnetometry and mantle convection

Lunar magnetometer data was used to indicate a lunar thermal boundary layer which is no more than 200 km thick and a lunar interior which is relatively isothermal. A direct comparison of temperature profiles with the experimental observations is used. It is assumed that the significant variation in lunar electrical conductivity is due to temperature alone and that it may be written in exponential form with a fixed and unknown activation energy and normalization constant. Experimental values of the lunar transfer function compared to theoretical curves generated by several temperature profiles show a significant temperature gradient only in the very outer portion of the moon. The steep curve of the variation of the transfer function with frequency implies an increase in electrical conductivity of no more than one order of magnitude with a depth between 1565 and 1000 km.

Kuckes, A. F.↗

Global empirical model of the Venus thermosphere

Direct measurements of neutral CO2, O, CO, N2, He, and N densities from the Pioneer Venus Orbiter Neutral Mass Spectrometer are described in terms of a spherical harmonic representation (latitude and local time coordinates) of exospheric temperature and number densities at 150 km, using modified Bates temperature profiles. The exospheric temperatures are determined from the altitude variations of atomic oxygen. A global average temperature of 228 K is derived with a first harmonic variation of 5%. The altitude profiles are extended downward to 100 km by using empirical formulas to provide a transition through the turbopause region (simulating the effect of eddy diffusion and vertical flows) and matching entry probe density data. The model reflects the observed variations of temperature and density with the 10.7 cm radio flux index. For a given change in flux at the planet, the exospheric temperature on Venus changes by only 10% of the change seen in the terrestrial thermosphere.

Hedin, A. E.↗

Comparison of radiative-convective models with constant and pressure-dependent lapse rates

One of the most commonly used models for studying climatic processes is the convective adjustment radiation model. In current radiation models, stable temperature profiles are maintained with a convective adjustment in which the temperature lapse rate is set equal to a critical lapse rate whenever the computed lapse rates exceed the critical value. First introduced by Manabe and Strickler (1964), a variety of convective adjustment models are now in use. It is pointed out that on a global scale, moist adiabatic processes, and thus moist adiabatic lapse rates, approximate the atmospheric temperature profile. Comparisons of profiles from a one-dimensional-radiative-convective model have been made using the conventional 6.5 K/km as the critical lapse rate and the pressure-dependent moist adiabatic lapse rates. For a clear sky and a single effective cloud the surface temperatures are 1 to 3 K higher with the constant 6.5 K/km critical lapse rate.

Hummel, J. R.↗

Regional surface fluxes from satellite-derived surface temperatures (AVHRR) and radiosonde profiles

Radiometric surface temperatures, derived from measurements by the AVHRR instrument aboard the NOAA-9 and the NOAA-11 polar orbiting satellites, were used in combination with wind velocity and temperature profiles measured by radiosondes, to calculate surface fluxes of sensible heat. The measurements were made during FIFE, the First ISLSCP (International Satellite Land Surface Climatology Project) Field Experiment, in a hilly tall grass prairie area of northeastern Kansas. The method of calculation was based on turbulent similarity formulations for the atmospheric boundary layer. Good agreement (r = 0.7) was obtained with reference values of sensible heat flux, taken as arithmetric means of measurements with the Bowen ratio method at six ground stations. The values of evaporation (latent heat fluxes), derived from these sensible heat fluxes by means of the energy budget, were also in good agreement (r = 0.94) with the corresponding reference values from the ground stations.

Brutsaert, Wilfried↗

Mean state densities, temperatures and winds during the MAC/SINE and MAC/EPSILON campaigns

Two field campaigns were conducted, primarily in northern Norway, in the summer and late autumn of 1987; these yielded a total of 41 in situ temperature profiles and 67 in situ wind profiles. Simultaneously, ground-based measurements were conducted of OH temperatures and sodium lidar temperatures for 85 and 104 hours, respectively. The summer campaign's mean temperature profile exhibited major deviations from the CIRA (1986) reference atmosphere; the differences between this model and the observations are less pronounced in the autumn. Both the summer and autumn mean wind profiles were in general agreement with the CIRA model.

Luebken, F.-J.↗

Liquid hydrogen and liquid oxygen feedline passive recirculation analysis

During the National Launch System design phase, a computer code (FEEDLINE) was written to analyze the feasibility of using passive recirculation propellant conditioning for the LH2 and LO2 feed systems. The FEEDLINE code was employed to provide temperature profiles to the STME design team. The team used the temperature profiles to determine if the required Space Transportation Main Engine net positive suction pressure was met. One desired outcome of the LH2 testing was to determine if modifications are required for the FEEDLINE code. The initial LN2 calibration tests indicate that the environmental heat into the system decreases with increasing heater input.

Holt, Kimberly A.↗

Comparisons of Gas-phase Temperature Measurements in a Flame Using Thin-Filament Pyrometry and Thermocouples

Less-intrusive, fast-responding, and full-field temperature measurements have long been a desired tool for the research community. Recently, the emission of a silicon-carbide (SiC) fiber placed in a flowing hot (or reacting) gas has been used to measure the temperature profile along the length of the fiber. The relationship between the gas and fiber temperature comes from an energy balance on the fiber. In the present work, we compared single point flame temperature measurements using thin-filament pyrometry (TFP) and thermocouples. The data was from vertically traversing a thermocouple and a SiC fiber through a methanol/air diffusion flame of a porous-metal wick burner. The results showed that the gas temperature using the TFP technique agreed with the thermocouple measurements (25.4 m diameter wire) within 3.5% for temperatures above 1200 K. Additionally, we imaged the entire SiC fiber (with a spatial resolution of 0.14 mm) while it was in the flame using a high resolution CCD camera. The intensity level along the fiber length is a function of the temperature. This results in a one-dimensional temperature profiles at various heights above the burner wick. This temperature measurement technique, while having a precision of less than 1 K, showed data scatter as high as 38 K. Finally, we discuss the major sources of uncertainty in gas temperature measurement using TFP.

Struk, Peter↗

Differential absorption lidar measurements of atmospheric temperature and pressure profiles

The theory and methodology of using differential absorption lidar techniques for the remote measurement of atmospheric pressure profiles, surface pressure, and temperature profiles from ground, air, and space-based platforms are presented. Pressure measurements are effected by means of high resolution measurement of absorption at the edges of the oxygen A band lines where absorption is pressure dependent due to collisional line broadening. Temperature is assessed using measurements of the absorption at the center of the oxygen A band line originating from a quantum state with high ground state energy. The population of the state is temperature dependent, allowing determination of the temperature through the Boltzmann term. The results of simulations of the techniques using Voigt profile and variational analysis are reported for ground-based, airborne, and Shuttle-based systems. Accuracies in the 0.5-1.0 K and 0.1-0.3% range are projected.

Korb, C. L.↗

Numerical and Experimental Study of Transport Phenomena in Directional Solidification of Succinonitrile

A numerical and experimental study of the growth of succinonitrile (SCN) using a horizontal Bridginan furnace and transparent glass ampoule was conducted. Two experiments were considered: one in which the temperature profile was fixed relative to the ampoule (no-growth case); and a second in which the thermal profile was translated at a constant rate (steady growth case). Measured temperature profiles on the outer surface of the ampoule were used as thermal boundary conditions for the modelling. The apparent heat capacity formulation combined with the variable viscositymeth~ was used to model the phase change in SeN. Both 2-D and 3-D models were studied and numerical solutions obtained using the commercial finite element code, FIDAP1. Comparison of the numerical results to experimental data showed excellent agreement. The complex 3-D shallow-cavity flow in the melt, differences between 2-D and 3-D models, effects of natural convection on the thermal gradient and shape of the solid/liquid interface, and the sensitivity of simulations to specific assumptions, are also discussed.

de Groh, Henry C., III↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tunable coherent mixed-dimensional perovskite heterojunctions and quantum wells grown from solution

Coherent heterojunctions, quantum wells and multiple quantum wells are needed for high-performance devices; these are generally grown via a dedicated vapour phase epitaxy process. Here we demonstrate the growth of coherent perovskite heterojunctions and quantum wells made of mixed-dimensional perovskites using a solution process. By exploiting the solubility difference of methylammonium (MA + ) and 4-(aminomethyl)piperidinium (4AMP 2+ ), we assemble layered perovskites with different layer numbers. The resulting 4AMP-MA n–1 Pb n I 3n+1 materials each with different layer numbers or bandgaps form quantum wells. Heterojunctions and quantum wells made of 4AMP-MA 2 Pb 3 I 10 (n = 3) and 4AMP-MAPb 2 I 7 (n = 2) with various barrier thickness are tailored by the solution temperature profile during crystal growth. Multiple quantum wells have been formed by cycling temperature profiles. The planar heterojunction and quantum wells have lattice matching without interfacial defects, and exhibit strong thermal stability. Type I band alignment at the n = 2/n = 3 heterojunction is confirmed by both computation and optical studies. In conclusion, this study opens a new direction for the development of sophisticated perovskite heterojunction and quantum well devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗