Neutron Imaging dataset for SMC 2021 data challenge

The neutron radiography (nR) dataset provides information of the neutron events as measured for the Siemens star mask using the Timepix3 detector. The recordings consist of the position (x and y axes), the time-stamp, and time-over-threshold (TOT) values of each neutron event.

Peterson, Peter↗

Design, production, and testing of field effect transistors

Cryogenic MOSFETS (CRYOFETS), specifically designed for low temperature preamplifier application with infrared extrinsic detectors were produced and comparatively tested with p-channel MOSFETs under matched conditions. The CRYOFETs exhibit lower voltage thresholds, high source-follower gains at lower bias voltage, and lower dc offset source voltage. The noise of the CRYOFET is found to be 2 to 4 times greater than the MOSFET with a correspondingly lower figure of merit (which is established for source-follower amplifiers). The device power dissipation at a gain of 0.98 is some two orders of magnitude lower than for the MOSFET. Further, CRYOFETs are free of low temperature I vs V character hysteresis and balky conduction turn-on effects and operate effectively in the 2.4 to 20 K range. These devices have promise for use on long term duration sensor missions and for on-focal-plane signal processing at low temperatures.

Sclar, N.↗

Galileo and Ulysses dust measurements - From Venus to Jupiter

The Galileo and Ulysses spaceprobes carry two similar dust detectors through interplanetary space from Venus to Jupiter. Impacts are reported which correspond to dust particles above a mass threshold of about 10 exp 13 g for which complete records exist. Between December 1989 and January 1992 Galileo repeatedly traversed interplanetary space between 0.7 and 2.26 AU and recorded 374 impacts. The observed impact rates ranged from 0.1 to about 3 impacts per day strongly dependent on whether the spacecraft moved toward or away from the sun. From October 1990 to January 1992 the Ulysses spacecraft had reached a distance of 5.17 AU from the sun and had recorded 72 impacts at rates between 0.1 and 0.5 per day. Inside about 2 AU the observed fluxes are compatible with a population of interplanetary dust particles moving on low to moderately eccentric and low inclination orbits. Outside this distance a dust particle population on different orbits is required in order to explain the Ulysses data.

Gruen, E.↗

Automated Monitoring with a BCP Fault-Decision Test

The Bayesian conditional probability (BCP) technique is a statistical fault-decision technique that is suitable as the mathematical basis of the fault-manager module in the automated-monitoring system and method described in the immediately preceding article. Within the automated-monitoring system, the fault-manager module operates in conjunction with the fault-detector module, which can be based on any one of several fault-detection techniques; examples include a threshold-limit-comparison technique or the BSP or SPRT technique mentioned in the preceding article. The present BCP technique is used to evaluate a series of one or more fault-detection events for the purpose of filtering out occasional false alarms produced by many types of statistical fault-detection procedures. The BCP technique increases the probability that an automated monitoring system produces a correct decision regarding the presence or absence of a fault. Because occasional false alarms are an inevitable consequence of the SPRT, BSP, or any other statistically based fault-detection test, there is a need for a logical procedure to distinguish between true and false alarms. Heretofore, it has been common practice to make a fault decision on an ad hoc basis for example by following a multiple-observation voting strategy in which a signal is declared to be indicative of a fault if m of the last n observations produced a fault-detection alarm. The BCP technique was developed to obtain results more reliable than those afforded by a voting strategy. The BCP technique involves a test in which one applies Bayesian inference techniques to a series of one or more single-observation alarms produced by a fault-detection test. One considers the last n decisions generated by a fault-detection test in order to evaluate the conditional probability that a failure is indicated (see figure). Each new decision reached by a fault-detection test is treated as a new piece of evidence about the state of the monitored asset, and the conditional probability of failure for the system is updated on the basis of this new evidence. The conditional probability of failure is compared with a predefined limit. For a probability below the limit, the asset is declared to be healthy. For a probability above the limit, the asset is declared to be faulty.

Bickford, Randall L.↗

First Measurement of Near-Threshold and Subthreshold 𝐽/𝜓 Photoproduction off Nuclei

We report on the first measurement of J/ψ photoproduction from nuclei in the photon energy range of 7 to 10.8 GeV, extending above and below the photoproduction threshold in the free proton of ∼ 8.2 GeV. The experiment used a tagged photon beam incident on deuterium, helium, and carbon, and the GlueX detector at Jefferson Lab to measure the semi-inclusive A(γ, e + e − p) reaction with a dilepton invariant mass M(e + e − ) ∼ m J/ψ = 3.1 GeV. The incoherent J/ψ photoproduction cross sections in the measured nuclei are extracted as a function of the incident photon energy, momentum transfer, and proton reconstructed missing light-cone momentum fraction. Comparisons with theoretical predictions assuming a dipole form factor allow extracting a gluonic radius for bound protons of p $\sqrt4⟨r^2⟩$ = 0.85 ± 0.14 fm. The data also suggest an excess of the measured cross section for sub-threshold production and for interactions with high missing light-cone momentum fraction protons. The measured enhancement can be explained by modified gluon structure for high-virtuality bound-protons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fine-Pitch CdTe Detector for Hard X-Ray Imaging and Spectroscopy of the Sun with the FOXSI Rocket Experiment

We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4 to 15 keV using the new technique of HXR focusing optics. The focal plane detector requires less than 100 micrometers position resolution (to take advantage of the angular resolution of the optics) and approximately equals 1 keV energy resolution (full width at half maximum (FWHM)) for spectroscopy down to 4 keV, with moderate cooling (greater than -30 C). Double-sided silicon strip detectors were used for the first FOXSI flight in 2012 to meet these criteria. To improve the detectors' efficiency (66% at 15 keV for the silicon detectors) and position resolution of 75 micrometers for the second launch, we fabricated double-sided CdTe strip detectors with a position resolution of 60 micrometers and almost 100% efficiency for the FOXSI energy range. The sensitive area is 7.67 mm x 7.67 mm, corresponding to the field of view of 791'' x 791''. An energy resolution of 1 keV (FWHM) and low-energy threshold of approximately equals 4 keV were achieved in laboratory calibrations. The second launch of FOXSI was performed on 11 December 2014, and images from the Sun were successfully obtained with the CdTe detector. Therefore, we successfully demonstrated the detector concept and the usefulness of this technique for future HXR observations of the Sun.

Ishikawa, Shin-nosuke↗

Nucleon Decays into Light New Particles in Neutrino Detectors

Proton and neutron decays into light new particles 𝑋 can drastically change the experimental signatures and benefit from the complementarity of large water-Cherenkov neutrino detectors such as Super- and Hyper-Kamiokande and tracking detectors such as JUNO and DUNE. The proton decays 𝑝 → ℓ + ⁢𝑋 and 𝑝 → 𝜋 + ⁢𝑋 with 𝑚 𝑋 near phase-space closure lead to charged particles below the Cherenkov threshold, rendering them practically invisible in Super- and Hyper-Kamiokande but not in JUNO and DUNE, which are therefore uniquely positioned for these baryon-number-violating signatures despite their smaller size. As an additional signature, such nucleon decays in the Earth can produce a sizable flux of 𝑋 particles in underground detectors. We present a simple model in which nucleons decay into sub-GeV sterile neutrinos that subsequently decay through active-sterile neutrino mixing, with a promisingly large number of events in Super-Kamiokande even in the seesaw-motivated parameter space.

Baryon & lepton number symmetries↗

High Statistics Measurements of $ν_μ$ Charged-Current Single $π^{+}$ Production with Zero Pion Kinetic Energy Threshold in MINERvA

This Letter presents measurements of single-differential cross sections of $ν_μ$-induced charged-current 1 $π^{+}$ production on scintillator using the MINERvA detector at Fermilab. These measurements use traditional track-based pion reconstruction as well as pions identified solely via Michel electron decays, allowing measurement of kinetic energies from 0 to 350 MeV. In total, 91,843 events were selected with $W_{exp}$$<$ 1.4 GeV/c. Differential cross sections as a function of pion and muon kinematic variables are presented and compared with the predictions of several neutrino event generators. Overall, modern pion production models tend to agree with data at the ends of the kinematic regions probed, but are discrepant with the main regions of the phase space probed by up to 15% in muon observables and up to 20% in pion observables. No model describes any of the variables well, and this result highlights model areas that require improvement for the next generation of neutrino oscillation experiments.

Granados, E. [Guanajuato U.]↗

Adaptive Thresholding and Parameter Estimation for PPM

A method of adaptive setting of a threshold level for the detection of pulses in a pulse-position modulation (PPM) free-space optical communication system has been developed. In simplified terms, it is desirable to set a threshold value high enough to greatly reduce the probability (PFA as defined below) of erroneously detecting noise as signal pulses but not so high as to greatly reduce the probability (PD as defined below) of detecting any signal pulses that may be present along with noise. In the present method, the threshold level is varied with time, in response to changing conditions in the optical-communication channel, in an effort to maintain a balance between the aforesaid competing requirements. An integral part of this adaptation scheme is a scheme for estimating key parameters of the optical-communication channel in particular, parameters that describe the fading and total attenuation in the channel, and parameters that characterize spreading of pulses by atmospheric and other effects. The method can be implemented by software processing of digitized optoelectronic-detector output, and has been tested by computational simulation. In the first stage of processing by this method, the digitized values of the detector output during noise-only time slots of received PPM symbols are averaged to obtain a background level. This background level is subtracted from the detector output in the hope of reducing or eliminating the noise component in the remaining signal. (This background level should not be confused with the detection threshold, which is computed in the last stage of processing.) Next, the remaining signal - in effect, a vector of pulse samples - is normalized by dividing it by its L1 norm (in general, the L1 norm of a vector is defined as the sum of absolute magnitudes of its orthogonal components).

Arabshahi, Payman↗

The role of fiber optics in mass spectrometer electro-optical ion detection

This paper describes the development of an electro-optical ion detector combining the best features of photographic and electrical ion detection (i.e., wide mass range coverage and low ion detection threshold respectively). A nineteen fold fiber optic image dissector is discussed which reformats the 1 mm x 361 mm mass spectrometer focal plane format to a 19 mm x 19 mm format suitable for vidicon imaging and electronic display of the data.

Norris, D. D.↗

Performance Assessment of the Optical Transient Detector and Lightning Imaging Sensor: Predicted Diurnal Variability - 1

Laboratory calibration and observed background radiance data are used to determine the effective sensitivities of the Optical Transient Detector and Lightning Imaging Sensor, as functions of local hour and pixel location within the instrument arrays. The effective LIS thresholds, expressed as radiances emitted normal to cloud top, are 4.0 plus or minus 0.7 and 7.6 plus or minus 3.3 micro J/ster/m (sup 2) for night and local noon; the OTD thresholds am 11.7 plus or minus 2.2 and 16.8 plus or minus 4.6 microJ/ster/m (sup 2). LIS and OTD minimum signal to noise ratios occur from 0800 to 1600 local time, and attain values of 10 plus or minus 2 and 20 plus or minus 3, respectively. False alarm rate due to instrument noise yields approximately 5 false triggers per month for LIS, and is negligible for OTD. Flash detection efficiency, based on prior optical pulse sensor measurements, is predicted to be 93 plus or minus 4% and 73 plus or minus 11% for LIS night and noon; 56 plus or minus 7% and 44 plus or minus 9% for OTD night and noon, corresponding to a 12 - 20% diurnal variability and LIS:OTD ratio of 1.7. Use of the weighted daily mean detection efficiency (i.e., not controlling for local hour) corresponds to a sigma = 8 - 9% uncertainty. These are likely overestimates of actual flash detection efficiency due to differences in pixel ground field-of-view across the instrument arrays, which are not accounted for in the validation optical pulse sensor data.

Boccippio, Dennis J.↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excitation of the metastable E(3 Sigma g plus) state of N2 by electron impact

The contribution of the N2(E(3 Sigma g plus)) state to the total metastable excitation function of N2 assessed on the basis of time-of-flight studies of metastable nitrogen molecules. The cross section for electron impact excitation state was determined in the domain of the resonance form threshold (11.87 eV) to an energy of about 13 eV. The maximum value of the cross section was found to be (7.0 + or - 4.0) x 10 to the -18th power sq cm at an energy of 12.2 eV. The measurement was made absolute by using the previously determined yield of the metastable detector, the lifetime of the E state, and by eliminating the energy spread in the electron beam from the raw data. The half-width (FWHM) of the resonance-like excitation function near threshold was found to be about 0.4 eV. No substantial evidence was obtained from the present data for the presence of the nonresonant part of the excitation function for the state studied.

Borst, W. L.↗

Measurements of attenuation and scattering properties of water-based liquid scintillator

Water-based liquid scintillator (WbLS) is a hybrid detector medium which has been proposed as a fill material for future large-volume rare event searches, including ν − detectors. This family of scintillating suspensions promises waterlike attenuation and scattering behavior, while offering scintillation light yield for sub-Cherenkov-threshold events. These features may allow for improved vertex and energy resolution, and concomitant improvements in background rejection and particle identification. While subscale measurements of light yield, timing and pulse-shape have been performed in several WbLS formulations, detailed measurements of the attenuation and scattering properties of WbLS remain a critical, unresolved step along the pathway to deployment. In pursuit of a better understanding of these parameters, a “long-arm” attenuation and scattering instrument has been developed at Lawrence Livermore National Laboratory, dubbed LASE (Livermore Attenuation and Scattering Experiment). Optical property measurements have been performed using LASE in DI water, Gd-water, WbLS and Gd-WbLS. Measurements of the optical properties of WbLS (1% LAB-PPO scintillator) provided by Brookhaven National Laboratory demonstrate an attenuation minimum of 4.87 × 10 − 4 ± 1.42 × 10 − 4 cm − 1 at 450 nm, while Gd-loaded WbLS (1% LAB-PPO scintillator, 0.1% Gd) demonstrated a minimum attenuation coefficient of 4.77 × 10 − 4 ± 1.27 × 10 − 4 cm − 1 at the same wavelength. Measurements of scattering in WbLS show a scattering coefficient of 3.39 × 10 − 4 ± 1.98 × 10 − 5 cm − 1 at the 450 nm attenuation minimum, while Gd-WbLS has a scattering coefficient of 2.8 × 10 − 4 ± 1.63 × 10 − 5 cm − 1 at that wavelength. These scattering and attenuation coefficients are significantly larger than measured for DI water at similar wavelengths ( 8.8 × 10 − 5 cm − 1 ± 3.8 × 10 − 5 attenuation at 430 nm, 2.2 × 10 − 5 ± 1.28 × 10 − 6 cm − 1 scattering). Though the WbLS attenuation and scattering coefficients measured are lower than the corresponding values published for ultrapure oils and LAB-PPO liquid scintillator, the material tested attenuates significantly more than water across the blue and green portions of the visible spectrum. This attenuation is markedly stronger at wavelengths under 430 nm. Published by the American Physical Society 2025

47 OTHER INSTRUMENTATION↗

Quantum noise and the threshold of hearing

It is argued that the sensitivity of the ear reaches a limit imposed by the uncertainty principle. This is possible only if the receptor cell holds the detector elements in a special nonequilibrium state which has the same noise characteristics as a ground (T = 0 K) state. To accomplish this 'active cooling' the molecular dynamics of the system must maintain quantum mechanical coherence over the time scale of the measurement.

Bialek, W.↗

Low-Noise Free-Running High-Rate Photon-Counting for Space Communication and Ranging

We present performance data for low-noise free-running high-rate photon counting method for space optical communication and ranging. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We successfully measured real-time communication performance using both the 2 detected-photon threshold and logic AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects without using other method of Time Gating The HgCdTe APD array routinely demonstrated very high photon detection efficiencies (50) at near infrared wavelength. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output. NASA GSFC has tested both detectors for their potential application for space communications and ranging. We developed and compare their performances using both the 2 detected photon threshold and coincidence methods.

Photons↗

Low-Noise Free-Running High-Rate Photon-Counting for Space Communication and Ranging

We present performance data for low-noise free-running high-rate photon counting method for space optical communication and ranging. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We successfully measured real-time communication performance using both the 2 detected-photon threshold and logic AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects without using other method of Time Gating The HgCdTe APD array routinely demonstrated very high photon detection efficiencies ((is) greater than 50%) at near infrared wavelength. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output. NASA GSFC has tested both detectors for their potential application for space communications and ranging. We developed and compare their performances using both the 2 detected photon threshold and coincidence methods.

Photons↗

Study of γ γ → γ ψ ( 2 S ) at Belle

Using 980 fb -1 of data at and around the Υ(nS)(n = 1, 2, 3, 4, 5) resonances collected with the Belle detector at the KEKB asymmetric-energy e+e- collider, the two-photon process γγ → γψ(2S) is studied from the threshold to 4.2 GeV for the first time. Two structures are seen in the invariant mass distribution of γψ(2S): one at M R 1 = 3922.4 ± 6.5 ± 2.0 MeV/c 2 with a width of Γ R 1 = 22 ± 17 ± 4 MeV, and another at M R 2 = 4014.3 ± 4.0 ± 1.5 MeV/c 2 with a width of Γ R 2 = 4 ± 11 ± 6 MeV; the signals are parametrized with the incoherent sum of two Breit- Wigner functions. The first structure is consistent with the X(3915) or the χ c2 (3930), and the local statistical significance is determined to be 3.1σ with the systematic uncertainties included. The second matches none of the known charmonium or charmonium like states, and its global significance is determined to be 2.8σ including the look-elsewhere effect. The production rates are Γ γγ B(R 1 → γψ(2S)) = 9.8 ± 3.6 ± 1.2 eV assuming (J PC , |λ|) = (0 ++ , 0) or 2.0 ± 0.7 ± 0.2 eV with (2 ++ , 2) for the first structure and Γ γγ B(R 2 → γψ(2S)) = 6.2 ± 2.2 ± 0.8 eV with (0 ++ , 0) or 1.2 ± 0.4 ± 0.2 eV with (2 ++ , 2) for the second one. Furthermore, the first errors are statistical and the second systematic, and λ is the helicity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗