Search NASA⌕ Search

SEARCH · Search NASA

Results for “THROUGHPUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Micro-Mechanically Guided High-Throughput Alloy Design Exploration Towards Metastability-Induced H Embrittlement Resistance

We develop a high-throughput approach for studying H embrittlement (HE)-resistance in alloys, which is based on combinatorial compositional screening of metastability effects by in situ scanning electron microscopy H-analyses. The project objective included: (i) technique development of high-throughput screening (HTS) for HE-resistance, (ii) discovery of new metallic materials with superior HE-resistance, (iii) Multiscale verification of HE-resistance of the new alloys and H-barrier layers, from atomic scale to an engineering scale. The investigation focused on a model system that enables exploration of different metastable states in Fe-based complex-concentrated alloys. Composition spread islands with hundreds of varying compositions are fabricated on a single substrate using a combinatorial co-sputtering technique. To screen these alloys, we developed and employed a home-built SEM-based integrated analysis system capable of characterizing H-permeability, H-trapping, H-influence on mechanical properties, and other material properties, as well as atomistic to continuum simulations to study the underlying physics.

08 HYDROGEN↗

High Throughput Solvent-free Manufacturing of Battery Electrodes

The project goal is to develop and demonstrate an advanced solvent-free lithium-ion battery electrode process through proposed Advanced Dry Electrode Process (ADEP) equipment, which is expected to exhibit a better binder fibrillization and high throughput and suitable for high performance electrode manufacturing, and commonize the anode and cathode dry processing equipment, supply chain and operation for lithium-ion battery OEMs for replacing the solvent-based slurry casting. Our proposed approach will facilitate low-cost battery production by addressing the following gaps in present dry electrode processing: • Extend the dry electrode fabrication process to lithium-ion battery anode manufacturing • Increase the active material content for anodes and cathodes • Intensify the process through improved mixing, powder rheology and surface modifications • Enable processing of next-generation electrode materials that are not stable to solvent or ambient air exposure. The project objectives include the development of anode-compatible binder and binder fibrillization promoter for low irreversible capacity loss, low electrode binder content yet higher film mechanical strength, and the optimization of solvent-free anode and cathode process for low cost (>60% electrode cost reduction), high performance (10% increase in energy density without sacrificing cycle life) and high throughput to enable next generation lithium-ion battery electrode production. Solvent-free electrode manufacturing will also enable next-generation cell designs based on prelithiated anodes or solid-state electrolytes.

25 ENERGY STORAGE↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗

MATRIX 2 RESULTS OF THE FY07 ENHANCED DOE HIGH-LEVEL WASTE MELTER THROUGHPUT STUDIES AT SRNL

High-level waste (HLW) throughput (i.e., the amount of waste processed per unit time) is a function of two critical parameters: waste loading (WL) and melt rate. For the Waste Treatment and Immobilization Plant (WTP) at the Hanford Site and the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS), increasing HLW throughput would significantly reduce the overall mission life cycle costs for the Department of Energy (DOE). The objective of this study was to generate supplemental validation data that could be used to determine the applicability of the current liquidus temperature (TL) model to expanded DWPF glass composition regions of interest based on higher WLs. Two specific flowsheets were used in this study to provide such insight: (1) Higher WL glasses (45 and 50%) based on future sludge batches that have (and have not) undergone the Al-dissolution process. (2) Coupled operations supported by the Salt Waste Processing Facility (SWPF), which increase the TiO{sub 2} concentration in glass to greater than 2 wt%. Glasses were also selected to address technical issues associated with Al{sub 2}O{sub 3} solubility, nepheline formation, and homogeneity issues for coupled operations. A test matrix of 28 glass compositions was developed to provide insight into these issues. The glasses were fabricated and characterized using chemical composition analysis, X-ray Diffraction (XRD), TL measurement and the Product Consistency Test (PCT). The results of this study are summarized below: (1) TiO{sub 2} concentrations up to {approx} 3.5 wt% were retained in DWPF type glasses, where retention is defined as the absence of crystalline TiO{sub 2} (i.e., unreacted or undissolved) in the as-fabricated glasses. Although this TiO{sub 2} content does not bound the projected SWPF high output flowsheet (up to 6 wt% TiO{sub 2} may be required in glass), these data demonstrate the potential for increasing the TiO{sub 2} limit in glass above the current limit of 2 wt% (based strictly on retention or solubility). (2) For those study glasses that had very close compositional overlap with the model development and/or model validation ranges of the current DWPF TL model (except TiO{sub 2} and MgO concentrations), there was very little difference in the predicted and measured TL values. Even though the TiO{sub 2} concentrations were above the 2 wt% upper limit, the results indicate that the current T{sub L} model is applicable in this compositional region with TiO{sub 2} contents up to approximately 3.5 wt%. (3) As the target glass compositions diverge from the model development and validation ranges, the T{sub L} data suggest that the model under-predicted the measured values. These discrepancies imply that there are individual oxides or oxide combinations that need to be accounted for in the model. These oxides include B{sub 2}O{sub 3}, SiO{sub 2}, MnO, TiO{sub 2} and/or their combinations. More data would be required to fill in these anticipated DWPF compositional regions for higher WL glasses so that the model coefficients could be refit to account for these differences. (4) Based on PCT response of HWL-21 and HWL-22 (two glasses that were prone to nepheline formation) it appears that increasing the B{sub 2}O{sub 3} concentration in glass does not consistently suppress the formation of nepheline in glasses with higher Al{sub 2}O{sub 3} and/or Na{sub 2}O content. Although the chemical durabilities of the quenched versions of these glasses were very acceptable, the canister centerline cooled (ccc) glasses exhibited a considerable decrease in durability and were found to contain nepheline via XRD. In fact, one of the glasses had a release that was 5 times greater than that of the Environmental Assessment (EA) benchmark glass. These results suggest a need for a more fundamental understanding of the compositional and kinetic effects of nepheline formation in high WL glasses. (5) Data have been generated in support of the replacement of the homogeneity constraint with the Al{sub 2}O{sub 3} and/or sum of alkali constraints for coupled operations as previously completed for sludge-only operations. This strategy should be pursued for either the compositional region anticipated for coupled operations or as part of the variability study for each sludge batch. The PCT responses of the study glasses suggest a high probability that this strategy could be defended at some later date.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a New Remote Handling Design for High Throughput Annular Centrifugal Contactors

Advanced designs of nuclear fuel recycling plants are expected to include more ambitious goals for aqueous based separations including; higher separations efficiency, high-level waste minimization, and a greater focus on continuous processes to minimize cost and footprint. Therefore, Annular Centrifugal Contactors (ACCs) are destined to play a more important role for such future processing schemes. Previous efforts defined and characterized the performance of commercial 5 cm and 12.5 cm single-stage ACCs in a “cold” environment. The next logical step, the design and evaluation of remote capable pilot scale ACCs in a “hot” or radioactive environment was reported earlier. This report includes the development of remote designs for ACCs that can process the large throughput rates needed in future nuclear fuel recycling plants. Novel designs were developed for the remote interconnection of contactor units, clean-in-place and drain connections, and a new solids removal collection chamber. A three stage, 12.5 cm diameter rotor module has been constructed and evaluated for operational function and remote handling in highly radioactive environments. This design is scalable to commercial CINC ACC models from V-05 to V-20 with total throughput rates ranging from 20 to 650 liters per minute. The V-05R three stage prototype was manufactured by the commercial vendor for ACCs in the U.S., CINC mfg. It employs three standard V-05 clean-in-place (CIP) units modified for remote service and replacement via new methods of connection for solution inlets, outlets, drain and CIP. Hydraulic testing and functional checks were successfully conducted and then the prototype was evaluated for remote handling and maintenance suitability. Removal and replacement of the center position V-05R ACC unit in the three stage prototype was demonstrated using an overhead rail mounted PaR manipulator. This evaluation confirmed the efficacy of this innovative design for interconnecting and cleaning individual stages while retaining the benefits of commercially reliable ACC equipment for remote applications in the nuclear industry. Minor modifications and suggestions for improved manual remote servicing by the remote handling specialists were provided but successful removal and replacement was demonstrated in the first prototype.

99 GENERAL AND MISCELLANEOUS↗

High Throughput Screening of Nanostructured Hydrogen Storage Materials

Hydrogen storage is the most challenging task for the hydrogen economy. We established a multidisciplinary research program for high throughput combinatorial synthesis and characterization of novel nanoporous and metastable complex hydrides, coupled to fundamental material studies including electronic, structural and kinetic transport modeling, and pump-probe experiments. Our research is based the concept of hybrid nanostructures that store hydrogen by a combination of chemi- and physorption: atomic hydrogen is stored in metastable hydrides while molecule hydrogen is stored in the nanometer pores of the hydrides. Metastable nanostructured hydride has been achieved by introducing structural and compositional disorders through high throughput elemental substitution/doping, catalyst addition, and nonequilibrium processing. Fast screening compatible with the combinatorial synthesis was achieved by combining X-ray structural characterization with the development of a laser-based microbalance. Manufacturing of nanoporous metahydrides that are identified as promising by the combinatorial synthesis has been explored along with the materials search.

36 MATERIALS SCIENCE↗

RESULTS OF THE FY09 ENHANCED DOE HIGH LEVEL WASTE MELTER THROUGHPUT STUDIES AT SRNL

High-level waste (HLW) throughput (i.e., the amount of waste processed per unit time) is a function of two critical parameters: waste loading (WL) and melt rate. For the Waste Treatment and Immobilization Plant (WTP) at the Hanford Site and the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS), increasing HLW throughput would significantly reduce the overall mission life cycle costs for the Department of Energy (DOE). The objective of this task is to develop data, assess property models, and refine or develop the necessary models to support increased WL of HLW at SRS. It is a continuation of the studies initiated in FY07, but is under the specific guidance of a Task Change Request (TCR)/Work Authorization received from DOE headquarters (Project Number RV071301). Using the data generated in FY07, FY08 and historical data, two test matrices (60 glasses total) were developed at the Savannah River National Laboratory (SRNL) in order to generate data in broader compositional regions. These glasses were fabricated and characterized using chemical composition analysis, X-ray Diffraction (XRD), viscosity, liquidus temperature (TL) measurement and durability as defined by the Product Consistency Test (PCT). The results of this study are summarized below: (1) In general, the current durability model predicts the durabilities of higher waste loading glasses quite well. A few of the glasses exhibited poorer durability than predicted. (2) Some of the glasses exhibited anomalous behavior with respect to durability (normalized leachate for boron (NL [B])). The quenched samples of FY09EM21-02, -07 and -21 contained no nepheline or other wasteform affecting crystals, but have unacceptable NL [B] values (> 10 g/L). The ccc sample of FY09EM21-07 has a NL [B] value that is more than one half the value of the quenched sample. These glasses also have lower concentrations of Al{sub 2}O{sub 3} and SiO{sub 2}. (3) Five of the ccc samples (EM-13, -14, -15, -29 and -30) completely crystallized with both magnetite and nepheline, and still had extremely low NL [B] values. These particular glasses have more CaO present than any of the other glasses in the matrix. It appears that while all of the glasses contain nepheline, the NL [B] values decrease as the CaO concentration increases from 2.3 wt% to 4.3 wt%. A different form of nepheline may be created at higher concentrations of CaO that does not significantly reduce glass durability. (4) The T{sub L} model appears to be under-predicting the measured values of higher waste loading glasses. Trends in T{sub L} with composition are not evident in the data from these studies. (5) A small number of glasses in the FY09 matrix have measured viscosities that are much lower than the viscosity range over which the current model was developed. The decrease in viscosity is due to a higher concentration of non-bridging oxygens (NBO). A high iron concentration is the cause of the increase in NBO. Durability, viscosity and T{sub L} data collected during FY07 and FY09 that specifically targeted higher waste loading glasses was compiled and assessed. It appears that additional data may be required to expand the coverage of the T{sub L} and viscosity models for higher waste loading glasses. In general, the compositional regions of the higher waste loading glasses are very different than those used to develop these models. On the other hand, the current durability model seems to be applicable to the new data. At this time, there is no evidence to modify this model; however additional experimental studies should be conducted to determine the cause of the anomalous durability data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

To have value, comparisons of high-throughput phenotyping methods need statistical tests of bias and variance

The gap between genomics and phenomics is narrowing. The rate at which it is narrowing, however, is being slowed by improper statistical comparison of methods. Quantification using Pearson’s correlation coefficient ( r ) is commonly used to assess method quality, but it is an often misleading statistic for this purpose as it is unable to provide information about the relative quality of two methods. Using r can both erroneously discount methods that are inherently more precise and validate methods that are less accurate. These errors occur because of logical flaws inherent in the use of r when comparing methods, not as a problem of limited sample size or the unavoidable possibility of a type I error. A popular alternative to using r is to measure the limits of agreement (LOA). However both r and LOA fail to identify which instrument is more or less variable than the other and can lead to incorrect conclusions about method quality. An alternative approach, comparing variances of methods, requires repeated measurements of the same subject, but avoids incorrect conclusions. Variance comparison is arguably the most important component of method validation and, thus, when repeated measurements are possible, variance comparison provides considerable value to these studies. Statistical tests to compare variances presented here are well established, easy to interpret and ubiquitously available. The widespread use of r has potentially led to numerous incorrect conclusions about method quality, hampering development, and the approach described here would be useful to advance high throughput phenotyping methods but can also extend into any branch of science. The adoption of the statistical techniques outlined in this paper will help speed the adoption of new high throughput phenotyping techniques by indicating when one should reject a new method, outright replace an old method or conditionally use a new method.

59 BASIC BIOLOGICAL SCIENCES↗

Robust High-Throughput Phenotyping with Deep Segmentation Enabled by a Web-Based Annotator

The abilities of plant biologists and breeders to characterize the genetic basis of physiological traits are limited by their abilities to obtain quantitative data representing precise details of trait variation, and particularly to collect this data at a high-throughput scale with low cost. Although deep learning methods have demonstrated unprecedented potential to automate plant phenotyping, these methods commonly rely on large training sets that can be time-consuming to generate. Intelligent algorithms have therefore been proposed to enhance the productivity of these annotations and reduce human efforts. We propose a high-throughput phenotyping system which features a Graphical User Interface (GUI) and a novel interactive segmentation algorithm: Semantic-Guided Interactive Object Segmentation (SGIOS). By providing a user-friendly interface and intelligent assistance with annotation, this system offers potential to streamline and accelerate the generation of training sets, reducing the effort required by the user. Our evaluation shows that our proposed SGIOS model requires fewer user inputs compared to the state-of-art models for interactive segmentation. As a case study of the use of the GUI applied for genetic discovery in plants, we present an example of results from a preliminary genome-wide association study (GWAS) of in planta regeneration in Populus trichocarpa (poplar). We further demonstrate that the inclusion of a semantic prior map with SGIOS can accelerate the training process for future GWAS, using a sample of a dataset extracted from a poplar GWAS of in vitro regeneration. The capabilities of our phenotyping system surpass those of unassisted humans to rapidly and precisely phenotype our traits of interest. The scalability of this system enables large-scale phenomic screens that would otherwise be time-prohibitive, thereby providing increased power for GWAS, mutant screens, and other studies relying on large sample sizes to characterize the genetic basis of trait variation. Our user-friendly system can be used by researchers lacking a computational background, thus helping to democratize the use of deep segmentation as a tool for plant phenotyping.

54 ENVIRONMENTAL SCIENCES↗

High-Throughput Field Plant Phenotyping: A Self-Supervised Sequential CNN Method to Segment Overlapping Plants

High-throughput plant phenotyping—the use of imaging and remote sensing to record plant growth dynamics—is becoming more widely used. The first step in this process is typically plant segmentation, which requires a well-labeled training dataset to enable accurate segmentation of overlapping plants. However, preparing such training data is both time and labor intensive. To solve this problem, we propose a plant image processing pipeline using a self-supervised sequential convolutional neural network method for in-field phenotyping systems. This first step uses plant pixels from greenhouse images to segment nonoverlapping in-field plants in an early growth stage and then applies the segmentation results from those early-stage images as training data for the separation of plants at later growth stages. The proposed pipeline is efficient and self-supervising in the sense that no human-labeled data are needed. We then combine this approach with functional principal components analysis to reveal the relationship between the growth dynamics of plants and genotypes. We show that the proposed pipeline can accurately separate the pixels of foreground plants and estimate their heights when foreground and background plants overlap and can thus be used to efficiently assess the impact of treatments and genotypes on plant growth in a field environment by computer vision techniques. This approach should be useful for answering important scientific questions in the area of high-throughput phenotyping.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring Fiber Positioning Accuracy and Throughput with Fiber Dithering for the Dark Energy Spectroscopic Instrument

Highly multiplexed, fiber-fed spectroscopy is enabling surveys of millions of stars and galaxies. The performance of these surveys depends on accurately positioning fibers in the focal plane to capture target light. We describe a technique to measure the positioning accuracy of fibers by dithering fibers slightly around their ideal locations. This approach also enables measurement of the total system throughput and point-spread function delivered to the focal plane. We then apply this technique to observations from the Dark Energy Survey Instrument (DESI), and demonstrate that DESI positions fibers to within 0farcs08 of their targets (5% of a fiber diameter) and achieves a system throughput within about 7% of expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PSTN-054: Updated estimates of the Rubin system throughput and expected LSST image depth

This document presents updated estimates, as of May 2022, of the Rubin system throughput and compares them to throughput requirements from the LSST Science Requirements Document. In addition, it uses these estimates to forecast LSST's median single-visit and co-added image depths for the current (OpSim v2.0) baseline LSST cadence simulation: (23.8, 24.5, 24.0, 23.4, 22.7, 22.0) and (25.6, 26.9, 26.9, 26.4, 25.6, 24.8) in ugrizy, respectively. In addition, it uses these estimates to forecast LSST’s median single-visit and co-added image depths for the current baseline LSST cadence simulation. Estimated system performance relies on actual measurements of the performance of various system hardware components, and on simulations where measurements are still unavailable. The updated performance estimates meet all the relevant requirements from the LSST Science Requirements Document. As our knowledge of the as-buit system continues to improve, updates to these estimates will continue to be provided.

79 ASTRONOMY AND ASTROPHYSICS↗

High Throughput Experimental Materials Database

The mission of the High Throughput Experimental Materials Database (HTEM DB) is to enable discovery of new materials with useful properties by releasing large amounts of high-quality experimental data to public. The HTEM DB contains information about materials obtained from high-throughput experiments at the National Renewable Energy Laboratory (NREL).

36 MATERIALS SCIENCE↗

Continuous flow electrophoresis: The effect of sample concentration on throughput and resolution in an upward flowing system

The effect of sample concentration on throughput and resolution in a modified continuous particle electrophoresis (CPE) system with flow in an upward direction is investigated. Maximum resolution is achieved at concentrations ranging from 2 x 10 to the 8th power cells/ml to 8 x 10 to the 8th power cells/ml. The widest peak separation is at 2 x 10 to the 8th power cells/ml; however, the sharpest peaks and least overlap between cell populations is at 8 x 10 to the 8th power cells/ml. Apparently as a result of improved electrophoresis cell performance due to coasting the chamber with bovine serum albumin, changing the electrode membranes and rinse, and lowering buffer temperatures, sedimentation effects attending to higher concentrations are diminished. Throughput as measured by recovery of fixed cells is diminished at the concentrations judged most likely to yield satisfactory resolution. The tradeoff appears to be improved recovery/throughput at the expense of resolution.

Jandebeur, T. S.↗

Undetected error probability and throughput analysis of a concatenated coding scheme

The performance of a proposed concatenated coding scheme for error control on a NASA telecommand system is analyzed. In this scheme, the inner code is a distance-4 Hamming code used for both error correction and error detection. The outer code is a shortened distance-4 Hamming code used only for error detection. Interleaving is assumed between the inner and outer codes. A retransmission is requested if either the inner or outer code detects the presence of errors. Both the undetected error probability and the throughput of the system are analyzed. Results indicate that high throughputs and extremely low undetected error probabilities are achievable using this scheme.

Costello, D. J.↗

Reliability and throughput analysis of a concatenated coding scheme

The performance of a concatenated coding scheme for error control in ARQ systems is analyzed for both random-noise and burst-noise channels. In particular, the probability of undetected error and the system throughput are calculated. In this scheme, the inner code is used for both error correction and error detection, and the outer code is used for error detection only. Interleaving/deinterleaving is assumed within the outer code. A retransmission is requested if either the inner code or the outer code detects the presence of errors. Various coding examples are considered. The results show that concatenated coding can provide extremely high system reliability (i.e., low probability of undetected error) and high system throughput.

Deng, Robert H.↗

High throughput X-ray optics - An overview

Techniques for the production of high-throughput modular arrays of telescopes with net collecting areas exceeding 10 to the 5th sq cm and 20-arsec angular resolution are discussed. Techniques considered include the automated figuring of flats as parabolic reflectors, the replication of cylindrical shells, the alignment of thin lacquer-coated conical foils, electroforming, and the use of large diamond turning machines. High-throughput programs are described, and it is noted that future missions will emphasize high resolution spectroscopy.

Gorenstein, Paul↗

Flight worthy infrared bolometers with high throughput and low NEP

This paper describes the features of flight-worthy IR bolometers that were developed to meet the requirements of the Far Infrared Absolute Spectrometer (FIRAS) and the Diffuse Infrared Background Experiment (DIRBE) on the Cosmic Background Explorer of a short time constant, high throughput, and low noise equivalent power (NEP). The new bolometers use small chips of doped and compensated silicon as sensing elements, and diamond wafers coated with thin layers of Cr and Au as the absorbing substrate. The throughput values for the FIRAS bolometers and for DIRBE are 1.28 sr-sq cm, and 0.21 sr-sq cm, respectively. At 1.6, the time constants range from 3 to 40 ms, and their NEP range from 4 x 10 to the -15th to 1 x 10 to the -14th W/sq rt of Hz.

Serlemitsos, Aristides T.↗