Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Application of the trap-plus-precipitation hard X-ray burst model to the flare of August 4, 1972

The theory of Melrose and Brown (1976) concerning the X-ray spectrum resulting from combined precipitation and in-trap acceleration of nonthermal electrons is applied to a large solar flare on the basis of high-time-resolution hard X-ray data. The time behavior of the electron source function is inferred as a function of energy and mean ambient trap density. The results are interpreted in the context of a purely thick-target model, a static trap with continuous injection of fresh electrons, and a dynamic trap with continuous redistribution of electron energies. It is concluded that: (1) a minimum trap density exists below which the static-trap description cannot be valid; (2) a mean ambient trap density less than the cited minimum is possible if a dynamic trap is invoked; and (3) the electron source function at a given instant in such low-density dynamic traps may bear little or no resemblance to a power-law spectrum despite its production, via nonthermal bremsstrahlung, of a power-law X-ray spectrum.

Emslie, A. G.↗

Streaming reversal of energetic particles in the magnetotail during a substorm

A case of reversal in the streaming anisotropy of energetic ions and in the plasma flow observed from the IMP 8 spacecraft during a substorm on February 8, 1978 is studied in detail using measurements of energetic particles, plasma, and magnetic field. Four new features emerge when high time resolution data are examined in detail. The times of streaming reversal of energetic particles in different energy ranges do not coincide with the time of plasma flow reversal. Qualitatively different velocity distributions are observed in earthward and tailward plasma flows during the observed flow reversal intervals. Strong tailward streaming of energetic particles can be detected during northward magnetic field environments and, conversely, earthward streaming in southward field environments. During the period of tailward streaming of energetic particles, earthward streaming fluxes are occasionally detected.

Lui, A. T. Y.↗

Summer Arctic ice concentrations and characteristics from SAR and SSM/I data

The extent and concentration of the Summer minima provide indirect information about the long term ability of the perennial portion of the ice pack to survive the Arctic atmosphere and ocean system. Both active and passive microwave data were used with some success for monitoring the ice cover during the Summer, but they both suffer from similar problems caused by the presence of meltponding, surface wetness, flooding, and freeze/thaw cycles associated with periodic changes in surface air temperatures. A comparative analysis of ice conditions in the Arctic region using coregistered ERS-1 SAR (Synthetic Aperture Radar) and SSM/I (Special Sensor Microwave/Imager) data was made. The analysis benefits from complementary information from the two systems, the good spatial resolution of SAR data, and the good time resolution of and global coverage by SSM/I data. The results show that in many areas ice concentrations derived from SAR data are significantly different (usually higher) than those derived from passive microwave data. Additional insights about surface conditions can be inferred depending on the nature of the discrepancies.

Comiso, Joey C.↗

Generic Signatures of the Time Profiles of BATSE Cosmic Gamma-Ray Bursts

A new method is proposed, which allows the study of generic signatures of cosmic gamma-ray burst time histories. We average the 64 ms resolution time profiles of 275 bright bursts detected by BATSE. The profile of each burst is normalized by the maximum number of counts at the peak of the primary pulse, and individual pulses and interpulse valleys are selected from the normalized profiles by identical selection criteria. New generic temporal parameters are introduced, which characterize the duration and equivalent width of each pulse and the duration of each valley. The histograms of the total equivalent pulse width and summed pulse duration are bimodal. Bimodality is also seen in the histogram of the mean duration of individual pulses. Bursts from the short and long peaks of these distributions correspond to the two modes of the Third BATSE Burst Catalog T(sub 50) and T(sub 90) distributions. Therefore, these new burst parameters demonstrate that the observed bimodal temporal behavior results from properties of the pulsed emission of gamma-ray bursts. The long mode of the T(sub 90) histogram includes bursts with from one to approximately 20 pulses; the logarithmic mean pulse duration is 1.17 +/- 0.09 S; for the long events with more than one pulse, the logarithmic mean valley duration is 1.28 +/- 0.15 S. Bursts of the short mode of T(sub 90) are mainly single-pulse events, and the logarithmic mean pulse duration is much smaller, 0.20 +/- 0.01 s. For multipulse bursts of the T(sub 90) long mode, marginal correlations were found between the parameters of the pulses and valleys and the number of pulses. The basic signatures of the evolution of pulses and valleys along the time course of bursts are examined. Conclusions are drawn concerning the physics of gamma-ray emission by taking into account these signatures.

Mitrofanov, Igor G.↗

Anomalous Flows at Dayside High-Latitude Magnetopause as Observed by Interball Tail Probe

We analyze magnetopause crossings at high latitudes dayside magnetopause as observed by Interball Tail probe. High time resolution plasma data show strong short-time flows near magnetopause that strongly deviate from surrounding magnetosheath flow. Several quasi- periodic velocity variations are observed at times. Plasma parameters, such as number density, temperature and bulk velocity-of these flows are close to magnetosheath values. These anomalous flows are observed almost at every magnetopause crossing in this region. The ion velocity distributions in these regions indicate the presence of open field lines. Observed properties of these flows suggest their association with reconnection at high latitudes.

Vaisberg, O. L.↗

High-Speed PLIF Imaging of Hypersonic Transition over Discrete Cylindrical Roughness

In two separate test entries, advanced laser-based instrumentation has been developed and applied to visualize the hypersonic flow over cylindrical protrusions on a flat plate. Upstream of these trips, trace quantities of nitric oxide (NO) were seeded into the boundary layer. The protuberances were sized to force laminar-to-turbulent boundary layer transition. In the first test, a 10-Hz nitric oxide planar laser-induced fluorescence (NO PLIF) flow visualization system was used to provide wide-field-of-view, high-resolution images of the flowfield. The images had sub-microsecond time resolution. However these images, obtained with a time separation of 0.1 sec, were uncorrelated with each other. Fluorescent oil-flow visualizations were also obtained during this test. In the second experiment, a laser and camera system capable of acquiring NO PLIF measurements at 1 million frames per second (1 MHz) was used. This system had lower spatial resolution, and a smaller field of view, but the images were time correlated so that the development of the flow structures could be observed in time.

Danehy, P. M.↗

The annual cycle of satellite-derived sea surface temperature in the southwestern Atlantic Ocean

The annual cycle of sea surface temperature (SST) in the southwestern Atlantic Ocean was estimated using four years (July 1984-July 1988) of NOAA Advanced Very High Resolution Radiometer observations. High resolution satellite observations at 1-km space and daily time resolution were grided at 100-km space and 5-day time intervals to develop an analysis dataset for determination of low frequency SST variability. The integral time scale, a measure of serial correlation, was found to vary from 40 to 60 days in the domain of interest. The existence of superannual trends in the SST data was investigated, but conclusive results could not be obtained. The annual cycle (and, in particular, the annual harmonic) explains a large proportion of the SST variability. The estimated amplitude of the cycle ranges between 5 deg and 13 deg C throughout the study area, with minima in August-September and maxima in February. The resultant climatology is compared with an arbitrary 5-day satellite SST field, and with the COADS/ICE SST climatology. It was found that the higher resolution satellite-based SST climatology resolves boundary current structure and has significantly better structural agreement with the observed field.

Podesta, Guillermo P.↗

Shock Initiation Microscopy with High Time and Space Resolution

In this paper, we describe studies of shock initiation and shock-to-detonation transitions in energetic materials using a tabletop shock compression microscope with nanosecond time resolution and micrometer spatial resolution. Planar input shocks with durations of 4–20 ns are produced using 0–4.5 km/s laser-launched flyer plates. Emphasis is on measurements of temperature, velocities, pressure, and microstructure using photon Doppler velocimetry (PDV), optical pyrometry and high-speed videography. Techniques are discussed for fabricating disposable shock target arrays of tiny plastic-bonded explosives (PBX), liquid and powder explosives, and single-crystal explosives for high-throughput studies. Optical temperature measurements of shocked triaminotrinitrobenzene (TATB) are discussed. Since TATB is yellow, we developed methods to correct for the blue absorption to obtain more accurate temperatures. Hot spots in shocked polymer-encased HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) crystals are observed in real-time, showing a hot spot produced in a collapsing void that ignites a deflagration. Despite the small dimensions of our explosive charges (typically 1 mm diameter and 250 μm length), we produced reproducible detonation states in solid and liquid explosives using short-duration shocks near the von Neumann spike (VNS) pressure. We show the VNS pressure is associated with a transition to high-efficiency gas production from the explosives. In studies of NM, prior to detonation, we see reaction originating at hot spots which coalesce to form a superdetonation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impurity-enhanced core valence luminescence via Zn-doping in cesium magnesium chlorides

Scintillators with faster timing capabilities are currently in high demand for use in radiation detection systems in the fields of nuclear and medical physics. The limited number of suitable materials that meet the performance criteria of next generation detection systems presents an opportunity for discovery of new fast scintillator materials. In this work, the effects of doping several ultrafast core-valence luminescent (CVL) scintillators with divalent Zn is explored. Three compounds are investigated – CsMgCl 3 , Cs 2 MgCl 4 , and Cs 3 MgCl 5 – and single crystals of each doped with 5 mol% Zn are grown via the Bridgman method. Additionally, mixing across the full range of concentrations (from 0 % to 100 % Zn) is explored in the Cs 2 Mg 1-x Zn x Cl 4 and Cs 3 Mg 1-x Zn x Cl 5 systems. For low concentrations of Zn, light yields of all three compounds are enhanced (by up to ~60 %) compared to the pure crystals, achieving what we believe to be the brightest known CVL, CsMgCl 3 :Zn 5 % (3400 ± 170 ph/MeV light yield). More importantly, Zn doping does not affect the ultrafast timing properties, with each composition maintaining a single-component decay time around 1–3 ns. A sub-100 ps coincidence time resolution (CTR) is also achieved with CsMgCl 3 :Zn 5 %. The results of this work reveal a new avenue towards obtaining brighter CVL materials, which could open up possibilities for more advanced ultrafast scintillators to be discovered moving forward.

36 MATERIALS SCIENCE↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Geostationary Instrument Simulator for Aerosol Observing System Simulation Experiments

In the near future, there will be several new instruments measuring atmospheric composition from geostationary orbit over North America, East Asia, and Europe. This constellation of satellites will provide high resolution, time resolved measurements of trace gases and aerosols for monitoring air quality and tracking pollution sources. This paper describes a detailed, fast, and accurate (less than 1.0% uncertainty) method for calculating synthetic top of the atmosphere (TOA) radiances from a global simulation with a mesoscale free running model, the GEOS-5 Nature Run, for remote sensing instruments in geostationary orbit that measure in the ultraviolet-visible spectral range (UV-Vis). Generating these synthetic observations is the first step of an Observing System Simulation Experiment (OSSE), a framework for evaluating the impact of a new observation or algorithm. This paper provides details of the model sampling, aerosol and cloud optical properties, surface reflectance modeling, Rayleigh scattering calculations, and a discussion of the uncertainties of the simulated TOA radiance. An application for the simulated TOA radiance observations is demonstrated in the manuscript. Simulated TEMPO (Tropospheric Emissions: Monitoring of Pollution) and GOES-R (Geostationary Operational Environmental Satellites) observations were used to show how observations from the two instruments could be combined to facilitate aerosol type discrimination. The results demonstrate the viability of a detailed instrument simulator for radiance measurements in the UV-Vis that is capable of accurately simulating high resolution, time-resolved measurements with reasonable computational efficiency.

Castellanos, Patricia↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

XIPE the X-Ray Imaging Polarimetry Explorer

X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017. The proposal was, unfortunately, not selected. To be compliant with this schedule, we designed the payload mostly with existing items. The XIPE proposal takes advantage of the completed phase A of POLARIX for an ASI small mission program that was cancelled, but is different in many aspects: the detectors, the presence of a solar flare polarimeter and photometer and the use of a light platform derived by a mass production for a cluster of satellites. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus. Two additional GPDs filled with a 3-bar Ar-DME mixture always face the Sun to detect polarization from solar flares. The Minimum Detectable Polarization of a 1 mCrab source reaches 14 in the 210 keV band in 105 s for pointed observations, and 0.6 for an X10 class solar flare in the 1535 keV energy band. The imaging capability is 24 arcsec Half Energy Width (HEW) in a Field of View of 14.7 arcmin 14.7 arcmin. The spectral resolution is 20 at 6 keV and the time resolution is 8 s. The imaging capabilities of the JET-X optics and of the GPD have been demonstrated by a recent calibration campaign at PANTER X-ray test facility of the Max-Planck-Institut fr extraterrestrische Physik (MPE, Germany). XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil). The data policy is organized with a Core Program that comprises three months of Science Verification Phase and 25 of net observing time in the following 2 years. A competitive Guest Observer program covers the remaining 75 of the net observing time.

Astronomy X-ray Polarimetry↗

Preliminary Results from ADRIANO2 Test Beams

A novel high-granularity, dual-readout calorimetric technique (ADRIANO2) is under development as part of the research program of T1604 Collaboration. (Talk Presented at the 19th International Conference on Calorimetry in Particle Physics (CALOR 2022), University of Sussex, Sussex, UK, 16–20 May 2022). The building block of such a calorimeter consists of a pair of optically isolated, small size tiles made of scintillating plastic and lead glass. The prompt Čerenkov light from the glass can be exploited to perform high resolution timing measurements, while the high granularity provides good resolution of the spatial components of the shower. Dual-readout compensation and particle flow techniques can be applied simultaneously to the scintillation and to the Čerenkov section, providing excellent energy resolution as well as PID particle identification. These characteristics make ADRIANO2 a 6-D detector, suited for High Energy as well as High Intensity experiments. A report on the status of the ADRIANO2 project, preliminary measurements of light yield, and current and future R&D plans by T1604 Collaboration are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the U.S. Western Electric Interconnection to Understand the Consequences of Hydrometeorological Extremes and Options for Risk Mitigation

Electricity grid operators around the world face a dual challenge; withstanding increasingly severe weather and the longer term impacts of climate change, while simultaneously decarbonizing. Extreme weather events such as heat waves and droughts are rising in both severity and frequency, which is threatening the reliability of electricity grids through increased demand, generation capacity losses, and equipment failures. Consequently, incorporating hydrometeorological stressors into computational power systems analysis is becoming an even more critical tool in long term planning and short term operations. However, there is a general lack of open-source customizable grid simulation software capable of exhaustively stress testing the grid under hydrometeorological uncertainty, and/or examining potential risk mitigation pathways. A related, persistent challenge for power system modelers is striking an appropriate balance between model fidelity (e.g. spatial scale and time resolution) and computational tractability (wall clock run-time). In this study, we are proposing a solution to this problem with open-source software that allows users to seamlessly customize the scale and track the accuracy of grid operations models. Our approach allows users to search over numerous model parameters (network topology, mathematical formulation, economic hurdle rates, and transmission line scaling) to identify model instantiations that accommodate experimental design. Further, we use this approach to demonstrate the importance of including extreme weather events in model validation and model selection. Focusing on the occurrence of heatwaves and droughts in the U.S. Western Interconnection, we examine role of extreme events in balancing tradeoffs between model fidelity and run-time at the model design stage.

Economics↗

Observations of potential ultra high energy gamma-ray sources above 10(15) eV

The Haverah Park 50 m water-Cerenkov array has been used to examine a number of periodic sources for ultra high energy gamma-ray emission above 10 to the 15th power eV. The data, recorded between 1 Jan. 1979 and 31 Dec. 1984, feature a modest angular resolution of approx 3 deg with millisecond arrival time resolution post 1982. The sources investigated include the Crab pulsar, Her X-1, Au0115 + 63 and Geminga. All objects have been detected by workers in the TeV region, with varying degrees of confidence.

Lambert, A.↗

Holocinematographic Velocimeter

Holographic movies used to study turbulent flows. High-speed movie composed of single-exposure holograms of tracer particles in each of two simultaneous orthogonal views of flow. Time resolution set by movie frame rate, and total time limited by length of movie. Data from system used to verify results of theoretical models and numerical simulations of turbulence, visualize and measure coherent structures in "non-simple" turbulent flows, to examine mechanisms operative in various turbulence-control/drag-reduction concepts.

Weinstein, Leonard M.↗