Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tensile Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The negative effect of Zr addition on the high temperature strength in alumina-forming austenitic stainless steels

The effect of a Zr addition on the precipitation behavior and mechanical properties in Nb-containing alumina-forming austenitic (AFA) stainless steels was investigated using tensile tests, scanning electron microscopy (SEM), and scanning transmission electron microscopy (STEM) analysis. The TEM observation showed that a Zr addition led to the formation of a (Nb,Zr)(C,N) complex particle, which coarsened the Nb-rich carbonitride. Tensile tests were performed at an elevated temperature (700 °C), and both the tensile and yield strengths decreased with a Zr addition. This unexpected result of a Zr addition was due to the reduction of the precipitation strengthening by particle coarsening. - Highlights: • The effect of Zr on high temperature strength in AFA steel containing Nb was studied. • Both the tensile and yield strengths of an AFA steel decreased with Zr-addition. • This is due to the reduction of precipitation strengthening by particle coarsening. • Nb(C,N) and (Nb,Zr)(C,N) particles were precipitated in an AFA and Zr-added AFA steel. • The size of (Nb,Zr)(C,N) particle is much bigger than that of Nb(C,N) particle.

36 MATERIALS SCIENCE↗

10° off-axis testing of CFRP using DIC: A study on strength, strain and modulus

For the determination of the shear properties such as strength, strain and modulus of unidirectionally reinforced composites, nearly a dozen measurement techniques exist, several of which have found their way into standards. One non-standardized method for sheet materials is the 10° off-axis tensile test of unidirectional coupons. The current work focuses on the experimental investigation of tensile testing of CFRP-UD coupon specimens using the 10° off-axis test and DIC strain mapping to measure the full-field deformation response. A sensitivity analysis on the measured stresses, strains and moduli is performed by varying the aspect ratio of the specimens and the location of strain measurement. Test related uncertainties such as the loading angle and specimen preparation details are investigated and quantified with the help of these full-field DIC measurements.

42 ENGINEERING↗

A machine learning approach to determine the elastic properties of printed fiber-reinforced polymers

This work focuses on the simultaneous determination of the elastic constants and the fiber orientation state for a short fiber-reinforced polymer composite by performing a minimum of experimental tests. Here we introduce a methodology that enables the inverse determination of fiber orientation state and the in-situ polymer properties by performing tensile tests at the composite coupon level. We demonstrate the approach for the extrusion deposition additive manufacturing (EDAM) process to illustrate one application of the methodology, but the development is such that it can be applied to short fiber-reinforced polymer (SFRP) systems processed via other methods. Currently, developing composites additive manufacturing digital twins require extensive material characterization. In particular, the mechanical characterization of the orthotropic elastic properties of a composite involves extensive sample preparation and testing, therefore the elasticity tensor is generally populated using a micromechanics model. This, however, requires measuring the fiber orientation state in addition to knowing the constituent material properties. Experimentally measuring the fiber orientation state can be tedious and time consuming. Further, optical methods are limited to resolving the orientation of cylindrical fibers or cluster of non-cylindrical fibers, and computed tomography (CT) methods scan regions of volume that are much smaller than a full printed bead. Therefore, we propose a methodology, accelerated by machine learning, to identify the anisotropic mechanical properties and fiber orientation state at the same time. Early results show that inference of the fiber orientation and composite properties is possible with as few as three tensile tests. Our results show that a combination of the choice of the micromechanics model and reliable set of experiments can yield the nine elastic constants, as well as, the fiber orientation state.

36 MATERIALS SCIENCE↗

Critical feature and seawater testing of cross-flow rotor components fabricated with additive manufacturing

Advanced manufacturing (AM) materials were investigated for their suitability for use in cross-flow turbine rotors. AM materials were categorized into 3 classes – plastics, metals, and ceramics – and reviewed for suitability based on a set of engineering requirements and criteria. Two plastics and two metals were selected to undergo further testing: Essentium CF25, Markforged Onyx, Titanium Ti-6Al-4V, and Inconel 718. Dogbone-shaped specimens were printed from each material in two sets. The first set was tensile tested to get a material baseline. The second set was submerged in the seawater tanks at PNNL-Sequim for 6 months to determine water uptake, corrosion, and biofouling resistance and then subsequently tensile tested. While few macroscopic changes could be observed after seawater testing, the plastic materials degraded significantly as compared to baseline, while the metal material properties remained consistent. Titanium and Inconel are used consistently by industry in extreme conditions, and the materials show promising performance for marine energy use cases.

McVey, James R.↗

Process development of 99.95% pure copper processed via selective electron beam melting and its mechanical and physical properties

Highlights: • Additively manufactured dense copper samples (>99.5%) • Measured electrical conductivity >58 MS/m (>100% IACS) • Equiaxed grain structure • 177 N/mm{sup 2} tensile strength, 87 N/mm{sup 2} yield strength, 59% elongation at fracture - Abstract: Additive manufacturing by selective electron beam melting (SEBM) was used to fabricate pure copper specimens. A process window at process temperature of 530 °C, gives the required beam powers and deflection speeds for manufacturing dense specimens (>99.5%). The microstructure of SEBM specimens was analyzed by using optical and scanning electron microscopy (SEM). Electrical conductivity, thermal conductivity, hardness, and mechanical performance were investigated by using eddy current, laser flash analysis, Vickers hardness and tensile tests, respectively. It was found that the variation of beam power and scan speed results in different microstructures from columnar to nearly equiaxed grain. The electrical conductivity of SEBM-processed specimens was above 58 MS/m (>100 IACS) while their hardness was around 55 HV0.05 and 46 HV5 without any dependency on processing parameters within the process window. The tensile tests revealed how vertical cracks affect the mechanical strength under tensile loading condition. The results of this study not only show a reliable process window but also introduce the links between processing parameters, defect formations, conductivity and mechanical strength of pure copper specimens manufactured by SEBM.

36 MATERIALS SCIENCE↗

Ca Addition Effects on the Microstructure, Tensile and Corrosion Properties of Mg Matrix Alloy Containing 8 wt.% Mg{sub 2}Si

The microstructure, tensile properties and corrosion behavior of the Mg-8 wt.% Mg{sub 2}Si-x%Ca alloy have been studied by the use of optical microscopy, scanning electron microscopy equipped with energy-dispersive spectroscopy, x-ray diffraction, standard tensile testing, polarization test and electrochemical impedance spectroscopy (EIS) measurements. Microstructural studies indicated that Ca modifies both primary and eutectic Mg{sub 2}Si phase. It was found that the average size of primary Mg{sub 2}Si particles is about 60 μm, which is dropped by about 82% in the alloy containing 0.05 wt.% Ca. By the addition of different Ca contents, Ca-rich intermetallics (i.e., CaSi{sub 2} and CaMgSi) were formed. The modification mechanism of adding Ca during solidification was found to be due to the strong effect of CaMgSi phase as a heterogonous nucleation site, apart from CaSi{sub 2} which was reported before, for Mg{sub 2}Si intermetallics. Tensile testing results ascertained that Ca addition enhances both ultimate tensile strength (UTS) and elongation values. The optimum amount of Ca was found to be 0.1 wt.%, which improved UTS and elongation values from about 130 MPa and 2% to 165 MPa and 5.5%, whereas more Ca addition (i.e., 3 wt.%) reduced the tensile properties of the alloy to about 105 MPa and 1.8%, which can be due to the formation of CaMgSi intermetallics with deteriorating needle-like morphology. Polarization and EIS tests also showed that the Mg-3%Si-0.5%Ca alloy pronounces as the best anti-corrosion alloy. Nevertheless, further added Ca (up to 3 wt.%) deteriorated the corrosion resistance due to predominance of worse galvanic coupling effect stemmed from the presence of stronger CaMgSi cathode in comparison with Mg{sub 2}Si. With higher Ca additions, an adverse effect was seen on corrosion resistance of the Mg-3%Si alloy, as a result of forming a weak film on the alloy specimen surface.

36 MATERIALS SCIENCE↗

Microstructural Characterization of Bonding Interfaces in Aluminum 3003 Blocks Fabricated by Ultrasonic Additive Manufacturing

Ultrasonic additive manufacturing (UAM) is a process by which hybrid and near-netshaped products can be manufactured from thin metallic tapes. One of the main concerns of UAM is the development of anisotropic mechanical properties. In this work, the microstructures in the bond regions are characterized with optical and electron microscopy. Recrystallization and grain growth across the interface are proposed as a mechanism for the bond formation. The presence of voids or unbonded areas, which reduce the load-bearing cross section and create a stress intensity factor, is attributed to the transfer of the sonotrode texture to the new foil layer. This results in large peaks and valleys that are not filled in during processing. Tensile testing revealed the weld interface strength was 15% of the bulk foil. Shear tests of the weld interfaces showed almost 50% of the bulk shear strength of the material. Finally, optical microscopy of the fracture surfaces from the tensile tests revealed 34% of the interface area was unbonded.

99 GENERAL AND MISCELLANEOUS↗

Creep Behavior and Durability of Cracked CMC

To understand failure mechanisms and durability of cracked Ceramic matrix composites (CMCs), Melt Infiltration (MI) SiCSiC composites with Sylramic-iBN fibers and full Chemical vapour infiltration SiCSiC composites with Sylramic-ion bombarded BN (iBN) and Hi-Nicalon -S fibers were pre-cracked between 150 to 200 megapascal and then creep and Sustained Peak Low Cycle Fatigue (SPLCF) tested at 13150 C at stress levels from 35 to 103 megapascal for up to 200 hours under furnace and burner rig conditions. In addition creep testing was also conducted on pre-cracked full Chemical vapour infiltration SiCSiC composites at 14500 C between 35 and 103 megapascal for up to 200 hours under furnace conditions. If the specimens survived the 200 hour durability tests, then they were tensile tested at room temperature to determine their residual tensile properties. The failed specimens were examined by Scanning electron microscope (SEM) to determine the failure modes and mechanisms. The influence of crack healing matrix, fiber types, crack density, testing modes and interface oxidation on durability of cracked Ceramic matrix composites (CMCs) will be discussed.

Creep↗

Low Earth Orbit Environmental Effects on Space Tether Materials

Atomic oxygen (AO) and ultraviolet (UV) radiation erode and embrittle most polymeric materials. This research was designed to test several different materials and coatings under consideration for their application to space tethers, for resistance to these effects. The samples were vacuum dehydrated, weighed and then exposed to various levels of AO or UV radiation at the NASA Marshall Space Flight Center. They were then re-weighed to determine mass loss due to atomic oxygen erosion, inspected for damage and tensile tested to determine strength loss. The experiments determined that the Photosil coating process, while affording some protection, damaged the tether materials worse than the AO exposure. TOR-LM also failed to fully protect the materials, especially from UV radiation. The POSS and nickel coatings did provide some protection to the tethers, which survived the entire test regime. M5 was tested, uncoated, and survived AO exposure, though its brittleness prevented any tensile testing.

Finckernor, Miria M.↗

Microstructural, mechanical and electrochemical behaviour of a 7017 Al–Zn–Mg alloy of different tempers

The aim of the investigation is to assess the microstructural features and associated physical, mechanical and electrochemical properties of a 7017 Al–Zn–Mg alloy of various tempers. A 7017 Al–Zn–Mg alloy was subjected to different ageing schedules to produce under-(T4), peak-(T6), over-(T7) and highly over-aged tempers. Optical microscopy, hardness measurement, electrical conductivity measurement, tensile testing and SEM fractographs, differential scanning calorimetry (DSC), transmission electron microscopy (TEM), and electrochemical polarization studies have been used to characterize the alloy tempers. Hardness measurement and tensile testing showed the characteristic age hardening phenomenon of aluminium alloys. Optical and TEM micrographs have revealed the variation in size of matrix strengthening η′ (MgZn{sub 2}) and also the size and distribution of grain boundary η (MgZn{sub 2}) precipitate with ageing time. DSC thermograms exhibiting exothermic and endothermic peaks indicated the characteristic solid state reaction sequence of the 7017 alloy. Potentiodynamic polarization study of the 7017 alloy of various tempers in 3.5 wt.% NaCl solution at near neutral pH showed typical active metal dissolution behaviour, but at pH 12 an active–passive–transpassive transition behaviour has been observed. - Graphical abstract: TEM micrograph of the 7017 aluminium alloy of various tempers (a, b) under aged (T4), (c, d) peak aged (T6), (e, f) over aged (T7) and (g, h) highly over-aged. Display Omitted - Highlights: • 7017 Al-Zn-Mg alloy was subjected to different artificial ageing treatments. • Characterization of 7017 alloy tempers by hardness, tensile, DSC, TEM and electrochemical behaviour. • Structure-properties relationship of the 7017 Al-Zn-Mg alloy of various tempers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary report on tests of tensile specimens with a part-through surface notch for a filament wound graphite/epoxy material

The behavior of tensile coupons with surface notches of various semi-elliptical shapes were evaluated for specimens obtained from a filament wound graphite/epoxy cylinder. The quasi-static test results, in some instances, are inadequate for defining complete trend curves and the interpretive analysis is considered to be preliminary. Specimens with very shallow notches were observed to be notch insensitive and the unnotched strength from these specimens was determined to be 54.97 Ksi. The failure strain of the laminate was found to be 1.328%. Specimens with deeper notches were sensitive to notch depth, notch aspect ratio, and specimen width. Using the unnotched strength of 54.97 Ksi and Poe's general toughness parameter, the fracture toughness was estimated to be 27.2 Ksi square root of In. Isotropic linear elastic fracture mechanics together with the estimated fracture toughness correctly predicted the influence of notch depth, aspect ratio, and specimen finitewidth.

Harris, C. E.↗

Edge softening of the Shuttle TPS strain isolation pad

Tensile tests and an analytical investigation were performed to characterize the edge softening behavior of the strain isolation pad (SIP) between the Orbiter skin and thermal protection system. The tensile tests were carried out with varying sizes of disk-shaped specimens bonded between aluminum disks. The specimens strength and stiffness were determined on the basis of specimen size, and an analytical model of the microstructural stress-strain characteristics was developed. Strength and stiffness were found to decrease near the free edges because through-the-thickness fibers located there were not anchored. No size dependence at maximum load was observed in specimens between 0.75-4.0 in. thick. In-plane and out-of-plane coupling in deformation was detected. The model gave accurate predictions of the tensile behavior of the SIP as a function of distance to a free edge.

Ransone, P. O.↗

On the Mechanical Behavior of LP-DED C103 Thin-Wall Structures

Laser Powder Directed Energy Deposition (LP-DED) can produce thin-wall features on the order of 1 mm. These features are essential for large structures operating in extreme environments such as regeneratively cooled nozzles and heat exchangers, which often make use of refractory metals. In this work, the mechanical behavior of LP-DED C103 was investigated via quasi-static tensile testing and low cycle fatigue (LCF) testing. The effects of vacuum stress relief (SR) and hot isostatic pressing (HIP) heat treatments were investigated for specimens in the vertical and horizontal build orientations during tensile testing. The AB and SR properties were lower than literature values for wrought and laser powder bed fusion (L-PBF) bulk components but higher than electron beam powder bed fusion (EB-PBF). The application of a HIP cycle improved strength by 7% and ductility by 27% past the initial as-built condition. Fracture images reveal that interlayer stress concentration sites are responsible for fracture in specimens in the vertical orientation. Meanwhile, fracture in the horizontal specimens mainly propagates at a slanted angle typical of plane stress conditions. The LCF results show cycles to failure ranging from 100 cycles to 8000 cycles for max strain levels of 2% and 0.5%, respectively. Fractography on the fatigue specimens reveals an increasing propagation zone as max strain levels are increased. The impact of these findings and future work are discussed in detail.

36 MATERIALS SCIENCE↗

Orientation dependent fracture behavior of nanotwinned copper

Columnar grown nanotwinned Cu was tensile tested in-situ inside the TEM in combination with automated crystal orientation mapping scanning transmission electron microscopy to investigate the active deformation mechanisms present in this material. Two tensile directions were applied, one parallel to the twin boundaries and the other perpendicular to the twin boundaries. In case of tensile testing perpendicular to the twin boundaries, the material deformed by detwinning and the formation of new grains, whereas in the parallel case, no new grains were formed and the fracture happened along the twin boundaries and a boundary that has formed during the deformation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Brittle Fracture of 2D MoSe 2

An in situ quantitative tensile testing platform is developed in this paper to enable the uniform in-plane loading of a freestanding membrane of 2D materials inside a scanning electron microscope. The in situ tensile testing reveals the brittle fracture of large-area MoSe 2 crystals and measures their fracture strength for the first time.

36 MATERIALS SCIENCE↗

Constitutive modeling for isotropic materials (HOST)

The results of the third year of work on a program which is part of the NASA Hot Section Technology program (HOST) are presented. The goals of this program are: (1) the development of unified constitutive models for rate dependent isotropic materials; and (2) the demonstration of the use of unified models in structural analyses of hot section components of gas turbine engines. The unified models selected for development and evaluation are those of Bodner-Partom and of Walker. A test procedure was developed for assisting the generation of a data base for the Bodner-Partom model using a relatively small number of specimens. This test procedure involved performing a tensile test at a temperature of interest that involves a succession of strain-rate changes. The results for B1900+Hf indicate that material constants related to hardening and thermal recovery can be obtained on the basis of such a procedure. Strain aging, thermal recovery, and unexpected material variations, however, preluded an accurate determination of the strain-rate sensitivity parameter is this exercise. The effects of casting grain size on the constitutive behavior of B1900+Hf were studied and no particular grain size effect was observed. A systematic procedure was also developed for determining the material constants in the Bodner-Partom model. Both the new test procedure and the method for determining material constants were applied to the alternate material, Mar-M247 . Test data including tensile, creep, cyclic and nonproportional biaxial (tension/torsion) loading were collected. Good correlations were obtained between the Bodner-Partom model and experiments. A literature survey was conducted to assess the effects of thermal history on the constitutive behavior of metals. Thermal history effects are expected to be present at temperature regimes where strain aging and change of microstructure are important. Possible modifications to the Bodner-Partom model to account for these effects are outlined. The use of a unified constitutive model for hot section component analyses was demonstrated by applying the Walker model and the MARC finite-element code to a B1900+Hf airfoil problem.

Chan, Kwai S.↗

Process Optimization of Bismaleimide (BMI) Resin Infused Carbon Fiber Composite

Bismaleimide (BMI) resins are an attractive new addition to world-wide composite applications. This type of thermosetting polyimide provides several unique characteristics such as excellent physical property retention at elevated temperatures and in wet environments, constant electrical properties over a vast array of temperature settings, and nonflammability properties as well. This makes BMI a popular choice in advance composites and electronics applications [I]. Bismaleimide-2 (BMI-2) resin was used to infuse intermediate modulus 7 (IM7) based carbon fiber. Two panel configurations consisting of 4 plies with [+45deg, 90deg]2 and [0deg]4 orientations were fabricated. For tensile testing, a [90deg]4 configuration was tested by rotating the [0deg]4 configirration to lie orthogonal with the load direction of the test fixture. Curing of the BMI-2/IM7 system utilized an optimal infusion process which focused on the integration of the manufacturer-recommended ramp rates,. hold times, and cure temperatures. Completion of the cure cycle for the BMI-2/IM7 composite yielded a product with multiple surface voids determined through visual and metallographic observation. Although the curing cycle was the same for the three panellayups, the surface voids that remained within the material post-cure were different in abundance, shape, and size. For tensile testing, the [0deg]4 layup had a 19.9% and 21.7% greater average tensile strain performance compared to the [90deg]4 and [+45deg, 90deg, 90deg,-45degg] layups, respectively, at failure. For tensile stress performance, the [0deg]4 layup had a 5.8% and 34.0% greater average performance% than the [90deg]4 and [+45deg, 90deg, 90deg,-45deg] layups.

Ehrlich, Joshua W.↗

Grips for Lightweight Tensile Specimens

Set of grips developed for tensile testing of lightweight composite materials. Double-wedge design substantially increases gripping force and reduces slippage. Specimen held by grips made of hardened wedges. Assembly screwed into load cell in tensile-testing machine.

Witte, William G., Jr.↗