Testing of the United Stirling 4-95 solar Stirling engine on test bed concentrator

The objectives with the testing, test set-ups, component designs, and the results of the testing of the solar Stirling engine in a parabolic dish system are presented. The most important tests are characterization of receivers, full day performance of complete system, cavity and aperture window test including influence from windeffects, control system tests, radiator system tests and special temperature measurements with infrared camera. The influence on performance of flux distribution depnding on concentrator alignment, and the optimum receiver operating criteria when balancing flux and temperatures on cooled receiver surface while avoiding flux on uncooled surfaces are also discussed.

Nelving, H. G.↗

Alignment and Verification Testing of the GPS LRA Test Bed

The LRCTF (Laser Ranging Characterization and Test Facility) is a unique facility built at NASA GSFC to provide thermal-optical testing of the next generation GPS LRA (Global Positioning Satellite’s Laser Retroreflector Array) laser ranging target. The 400mm diameter target is an array consisting of 48 total internal reflection retroreflectors and has an optical cross section requirement of 100 MSM (million square meters). To verify that the array meets this requirement during on-orbit conditions, the LRCTF is equipped with a 400mm test beam, a data product output consisting of full aperture FFDPs (Far Field Diffraction Patterns) and a thermal chamber. The FFDPs are used to calculate the OCS. This paper will describe the facility design, alignment approach, and verification process.

Patricia Lyons↗

Redesign of Carbon Dioxide Removal System for Multifunctional Sorbent Bed Testing

Carbon dioxide removal is a key function of Environmental Control and Life Support System (ECLSS) on the International Space System (ISS). Currently, this system uses pellet beds however they have known issues such as flow channeling and uneven heating. The Multifunction Sorbent (MultiSorb) project is developing 3D-printed zeolite beds with embedded heaters to address these issues. This poster lays out the steps in modifying the Carbon Dioxide Removal and Compression System (CRCS) to test the MultiSorb beds.

MultiSORB↗

High-Fidelity CFD Simulation of Mixed Convection and Forced Convection in a Pebble Bed Test Reactor Core

The Hermes low-power [35-MW(thermal)] reactor will be built and operated by Kairos Power LLC (KP) to demonstrate its fluoride salt-cooled high-temperature reactor (FHR) technology. In the KP FHR, the reactor core is composed of randomly packed pebbles with TRISO fuel particles inside with FLiBe flow upward through the core acting as a coolant. Previous numerical and experimental studies have been limited to either a small-size bed or to a lack of detailed measurements for heat transfer. Here, to address the lack of high-fidelity heat transfer data in a real-size FHR core, in this study, we simulated a pebble bed core with 34 374 pebbles randomly packed, similar to the Hermes reactor's size. The core radius was 14 times that of the pebble diameter, while the core height was 45 times. In this work, we were particularly interested in a mixed convection regime, where buoyancy is important. Therefore, we performed several large-eddy simulations at different Reynolds numbers (160 to 1000) with gravitational force included. The spectral element computational fluid dynamics code NekRS with graphics processing unit acceleration was used for this study. The low-Mach number approximation was applied to address property changes in the FLiBe and to account for buoyancy. A pure hexahedral mesh with 60 million elements was generated by the Voronoi cell method. At the polynomial order of 5, the total degrees of freedom was 7.5 billion. The developed case in this work is the first of its kind in terms of size and complexity. The local numerical data across the domain were obtained and compared with empirical correlations. After examining the data, we found the following conclusions. For pressure drop, the Reger correlation predicted less than a 5% error. On the other hand, for heat transfer, the Wakao correlation outperformed the others. Based on our findings, we recommend the use of the Wakao correlation for the Nusselt number calculation, and for pressure drop, the KTA (Kerntechnischer Ausschuss) correclation, among the available experimental correlations. In conclusion, the Reger direct numerical simulation-driven correlation for pressure drops should also be considered, given its best agreement with our calculations.

Mixed Convection↗

ADMS Test Bed Updates

This webinar will present results from a joint project with utility partner Xcel Energy in which we evaluated their ADMS application for volt-var optimization using different levels of model quality. We were able to help Xcel Energy understand the trade-offs of telemetry measurements and model quality when managing a feeder's voltage profile to maximize energy conservation. We simulated scenarios with varying levels of model quality and measurement density to evaluate Xcel's options for best using its ADMS. The results help Xcel and other utilities understand how network data affects voltage management as grid operations see continued growth in solar photovoltaic (PV) systems and electric vehicles (EVs).

ADMS↗

Status of New Models Hosted on the Virtual Test Bed (VTB) in 2022

The VTB hosts 20 distinct models, 8 of which were recently developed during 2022 and will be discussed in more detail here. This article provides an overview of the various models hosted and their capabilities. Part of the intent of the VTB is to showcase a ‘block’ style approach to modeling and simulation: if a capability is not showcased for a specific reactor type, it could, in theory, be easily ported/replicated from another. The breadth of advanced reactor types considered is representative of the large variety of concepts being proposed for demonstration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ADMS Test Bed: Defining a Use Case for Data Improvement for ADMS Deployment: Preprint

Advanced distribution management systems (ADMS) provide a suite of tools for meeting the needs of a modern grid - higher reliability and power quality, improved resiliency and security, lower costs and enhanced customer participation. Data quality has two-fold impact on ADMS adoption: 1. Data quality improvement may constitute up to 25% of ADMS deployment costs. 2. The accuracy of data and models used by the ADMS greatly affect the utility's ability to meet the operational objectives. Thus, quantifying the data quality requirements and its impact on performance is critical to reducing the overall cost of deployment, enabling wider adoption and ensuring that the ADMS performs as specified. The paper offers the motivation, methodology and evaluation strategy for filling this critical gap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flight Test Methodology for NASA Advanced Inlet Liner on 737MAX-7 Test Bed (Quiet Technology Demonstrator 3)

This paper describes the acoustic flight test results of an advanced nacelle inlet acoustic liner concept designed by NASA Langley, in a campaign called Quiet Technology Demonstrator 3 (QTD3). NASA has been developing multiple acoustic liner concepts to benefit acoustics with multiple-degrees of freedom (MDOF) honeycomb cavities, and lower the excrescence drag. Acoustic and drag performance were assessed at a lab-scale, flow duct level in 2016. Limitations of the lab-scale rig left open-ended questions regarding the in-flight acoustic performance. This led to a joint project to acquire acoustic flyover data with this new liner technology built into full scale inlet hardware containing the NASA MDOF Low Drag Liner. Boeing saw an opportunity to collect the acoustic flyover data on the 737 MAX-7 between certification tests at no impact to the overall program schedule, and successfully executed within the allotted time. The flight test methodology and the test configurations are detailed and the acoustic analysis is summarized in this paper. After the tone and broadband deltas associated with the inlet hardware were separated and evaluated, the result was a significant decrease in cumulative EPNL (Effective Perceived Noise Level).

Wong, Jackie W.↗

FLISR in the Presence of DERs ADMS Test Bed Use Case

Fault location, isolation, and restoration (FLISR) is one of the distribution automation applications that utilities are most interested in. It operates groups of switches on distribution feeders to improve the reliability of power delivery after localizing outages. FLISR is an essential function for enabling a self-healing grid, and it directly affects grid reliability and resilience. The presence of DERs brings both new opportunities and challenges for FLISR applications. For instance, some DERs can work as backup generation sources and help energize local networks so more switching options can be achieved with the coordination of FLISR operations; however, the existence of DERs also brings new challenges. The bidirectional power flow resulting from DERs might require dynamic changes to protective devices' fault current settings, and thus the FLISR application will need to dynamically adjust its operations in coordination with the dynamic protection settings. Also, some FLISR applications make their service restoration decisions and close tie-switches based on predefined rules; however, the presence of DERs and their impact on altering net loads on the local feeder network are not considered. For this use case, the project team is using the FLISR application of the Survalent ADMS operating on a real-time simulation of a feeder from Central Georgia EMC, a cooperative electric utility. The performance of the FLISR application is being evaluated for different locations and combinations of DERs, including grid-forming battery energy storage systems.

ADMS↗

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell↗