GLADE Global Liquid Argon Detector Experiment: A Letter of Intent to FNAL

The recent measurements of the θ 13 mixing angle, which controls the observable size of any CP violation effects, open a window of opportunity to take advantage of the world's most powerful existing neutrino beam together with recent successes in development of the ultimate detector technology for the detection of electron neutrinos : a liquid argon (LAr) time projection chamber. During this proposed project a 5kt LAr detector (GLADE) will be developed by European groups to be put in a cryostat in the NuMI neutrino beam at Fermi National Accelerator Laboratory in the US and will start taking data in 3-5 years time to address the neutrino mass ordering. The successful fruition of this project, along with nominal exposure at NOυA and T2K, together with information from double beta decay experiments could ascertain that neutrinos are Dirac particles in the next decade.

43 PARTICLE ACCELERATORS↗

Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector

Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. Here, we present a measurement of liquid xenon scintillation characteristics in the LUX dark matter detector and develop a pulse shaped based discrimination parameter to be used for particle identification. To accurately measure the scintillation characteristics, we develop a template-fitting method to reconstruct the detection time of photons. Analyzing calibration data collected during the 2013-16 LUX WIMP search, we measure a singlet-to-triplet scintillation ratio for electron recoils (ER) that is consistent with existing literature, and we make a first-ever measurement of the NR singlet-to-triplet ratio at recoil energies below 74 keV. A prompt fraction discrimination parameter exploits the difference of the photon time spectra for NR and ER events and is optimized to have the least number of ER events that occur in the 50% NR acceptance region. When this discriminator is used in conjunction with charge-to-light discrimination on the calibration data, the signal-to-noise ratio in the NR dark matter acceptance region increases by up to a factor of two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and perspectives of the ICARUS experiment at the Fermilab Short Baseline Neutrino program

In this study, the ICARUS collaboration has employed the 760 t T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous ν e appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around Δm 2 ~ 1 eV 2 . After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor. ICARUS will also jointly search for evidence of sterile neutrinos together with the Short-Baseline Near Detector, within the Fermilab Short-Baseline Neutrino program experiment, and will perform measurements of neutrino cross sections with both beams and several Beyond Standard Model searches with the NuMI beam. In this paper, the main technical achievements of the ICARUS detector subsystems (Time Projection Chambers, Light Detection System, Cosmic Ray Tagger, Trigger and Data Acquisition) obtained with both BNB and NuMI neutrino beams during the commissioning phase, will be presented in terms of the overall detector performance and capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Dark Matter Results from the XENON100 Experiment

The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter weakly interacting massive particles (WIMPs) scattering off 62 kg of liquid xenon in an ultralow background dual-phase time projection chamber. In this Letter, we present first dark matter results from the analysis of 11.17 live days of nonblind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the predefined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross sections above 3.4x10{sup -44} cm{sup 2} for 55 GeV/c{sup 2} WIMPs at 90% confidence level. Below 20 GeV/c{sup 2}, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics with gamma-beams and charged particle detectors: I) Nuclear structure II) Nuclear astrophysics

The Charged Particle Working Group (CPWG) is proposing to construct large area Silicon Strip Detector (SSD), a gas Time Projection Chamber detector read by an electronic readout system (eTPC) and a Bubble Chamber (BC) containing superheated high purity water to be used in measurements utilizing intense gamma-ray beams from the newly constructed ELI-NP facility at Magurele, Bucharest in Romania. We intend to use the SSD and eTPC detectors to address essential problems in nuclear structure physics, such as clustering and the many alpha-decay of light nuclei such as {sup 12}C and {sup 16}O. All three detectors (SSD, eTPC and BC) will be used to address central problems in nuclear astrophysics such as the astrophysical cross section factor of the {sup 12}C(α,γ) reaction and other processes central to stellar evolution. The CPWG intends to submit to the ELI-NP facility a Technical Design Report (TDR) for the proposed detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE): Conceptual Design Report. Volume 1: The LBNF and DUNE Projects

This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modular liquid argon time-projection chamber (LArTPC) located deep underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE will also have a high-resolution and high-precision near detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Observation of Two Protons in the Decay of {sup 54}Zn

The two protons emitted in the decay of {sup 54}Zn have been individually observed for the first time in a time projection chamber. The total decay energy and the half-life measured in this work agree with the results obtained in a previous experiment. Angular and energy correlations between the two protons are determined and compared to theoretical distributions of a three-body model. Within the shell model framework, the relative decay probabilities show a strong contribution of the p{sup 2} configuration for the two-proton emission. After {sup 45}Fe, the present result on {sup 54}Zn constitutes only the second case of a direct observation of the ground state two-proton decay of a long-lived isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

STAR results on central exclusive production in proton-proton collisions

We present a preliminary measurement of the Central Exclusive Production of the two oppositely charged pions produced in the process pp → ppπ{sup +} π{sup −}, obtained with the STAR detector at RHIC at √(s)=200 GeV. Silicon strip detectors placed in Roman Pots were used for tagging forward protons while pion pair tracks were reconstructed in the STAR Time Projection Chamber. Predictions of models based on Regge phenomenology are compared to the spectra of the kinematical variables corrected for detector acceptance and efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗

Development of a Micromegas TPC for Low Energy Heavy Ions Measurement for Nuclear Fission and Astrophysics Applications

Time Projection Chambers are widely used since many years for tracking and identification of charged particles in high energy physics. We present a new R and D project to investigate the feasibility of a Micromegas TPC for low energy heavy ions detection. Two physics cases are relevant for this project. The first is the study of the nuclear fission of actinides by measuring the fission fragments properties (mass, nuclear charge, kinetic energy) that will be performed at different installations and in particular at the NFS facility to be built in the framework of the SPIRAL2 project in GANIL. The second physics case is the study of heavy ion reactions, like ({alpha},{gamma}), ({alpha},p), ({alpha},n) and all the inverse reactions in the energy range between 1.5 and 3 AMeV using both stable and radioactive beams. These reactions have a key role in p process in nuclear astrophysics to explain the synthesis of heavy proton-rich nuclei. Within the project, a large effort is devoted to Monte-Carlo simulations and a detailed benchmark of different simulation codes on the energy loss and range in gas of heavy ions at low energy has been performed. A new approach for simulating the ion charge state evolution in GEANT4 is also presented. Finally, preliminary results of an experimental test campaign on prototype are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Studies Of An Exotic Decay Mode At The Proton Drip-Line: The Two-Proton Radioactivity

Two-proton radioactivity is an exotic decay mode for very proton-rich nuclei. It was observed experimentally for the first time in 2002 for the nucleus {sup 45}Fe but the two protons could not be directly detected. So a new detector has been developed, a Time Projection Chamber, to individually observe the two protons emitted. It was used successfully during two experiments for the study of {sup 45}Fe and {sup 54}Zn. Energy correlations have been studied and the relative angle between the two protons is calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DIURNAL AND ANNUAL VARIATIONS OF DIRECTIONAL DETECTION RATES OF DARK MATTER

Direction-sensitive direct detection of weakly interacting massive particles (WIMPs) as dark matter would provide an unambiguous non-gravitational signature of dark matter. The diurnal variation of dark matter signal due to Earth's rotation around its own axis can be a significant signature for Galactic WIMPs. Because of a particular orientation of Earth's axis of rotation with respect to the WIMP wind direction, the apparent direction of WIMP wind as observed at a detector can alter widely in a day. In this work, we calculate the directional detection rates with their daily and yearly modulations in Earth-bound dark matter experiments considering detailed features of the geometry and dynamics of the Earth-Sun system along with the solar motion in a Galactic frame. A separate halo model, namely the dark disk model other than the usual standard halo model for dark matter halo, is also considered and the results for two models are compared. We demonstrate the results for two types of gas detectors, namely DRIFT (target material CS{sub 2}) and NEWAGE (target material CF{sub 4}), which use Time Projection Chamber techniques for measuring directionality of the recoil nucleus. The WIMP mass and recoil energy dependence of the daily variation of event rates are computed for a specific detector, and the sensitive ranges of mass and recoil energies for the considered detector are probed.

79 ASTRONOMY AND ASTROPHYSICS↗

Liquid xenon detectors for particle physics and astrophysics

This article reviews the progress made over the last 20 years in the development and applications of liquid xenon detectors in particle physics, astrophysics, and medical imaging experiments. A summary of the fundamental properties of liquid xenon as radiation detection medium, in light of the most current theoretical and experimental information is first provided. After an introduction of the different type of liquid xenon detectors, a review of past, current, and future experiments using liquid xenon to search for rare processes and to image radiation in space and in medicine is given. Each application is introduced with a survey of the underlying scientific motivation and experimental requirements before reviewing the basic characteristics and expected performance of each experiment. Within this decade it appears likely that large volume liquid xenon detectors operated in different modes will contribute to answering some of the most fundamental questions in particle physics, astrophysics, and cosmology, fulfilling the most demanding detection challenges. From detectors based solely on liquid xenon (LXe) scintillation, such as in the MEG experiment for the search of the rare ''{mu}{yields}e{gamma}'' decay, currently the largest liquid xenon detector in operation, and in the XMASS experiment for dark matter detection, to the class of time projection chambers which exploit both scintillation and ionization of LXe, such as in the XENON dark matter search experiment and in the Enriched Xenon Observatory for neutrinoless double beta decay, unrivaled performance and important contributions to physics in the next few years are anticipated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ArgoNeuT and MicroBooNE: LAr-TPC's at Fermilab

Liquid Argon Time Projection Chamber technology provides unique features in event imaging and calorimetric resolution. These characteristics, combined with a good rejection power and a (virtually) unlimited active mass, make this detector one of the best candidate for the next generation of long-baseline neutrino oscillation experiments aimed at precision measurements of the MNPS matrix elements. Up to now the largest LAr-TPC operated is the first semi-module of the ICARUS T600 detector (300 tons of LAr). The scalability of this technology to massive detectors (>=5 ktons) is still to be proven. The ArgoNeuT detector, a small LAr-TPC (0.24 ton of active mass) exposed to the NuMI beam at FNAL currently producing the first low-energy neutrino events in a LAr-TPC, is the first step of a staged US program to realize and operate a massive LAr-TPC detector. The proposed MicroBooNE experiment, a LAr-TPC of 100 tons of active mass, to be exposed to the Booster Neutrino Beam and the NuMI beam at FNAL, is the next crucial step of this program. Design details and experimental goals of both experiments are reported in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

First Science Results from ZEPLIN-III

ZEPLIN-III uses a 12 kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionisation produced interactions in the liquid to differentiate between nuclear recoils expected from WIMPs and electron recoil background signals down to approx10 keV nuclear recoil energy. Analysis of 847 kgcentre dotdays of data acquired between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon elastic scattering spin-independent cross-section above 8.1x10approx{sup -8} pb at 60 GeVc{sup -2} with a 90% confidence limit. ZEPLIN-III demonstrated better discrimination at low-energy than previously achieved by any other xenon-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalability, Scintillation Readout and Charge Drift in a Kilogram Scale Solid Xenon Particle Detector

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a MICROMEGAS-based TPC in a high-energy neutron beam

The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). We report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited diffusion time. And for a binary drift gas, increasing the percentage of the molecular component (quench gas) relative to the noble component and operating at lower pressures generally improves stability.