Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 (E beam = 100 GeV) and 17 (255 GeV). For a typical 8 hour RHIC store, the measured proton beam average polarization was about P beam ~ 55 ± 2.0 stat ± 0.3 syst %. The elastic pp analyzing power, AN(t)~0.04, was determined with a precision of about |δA N (t)|~0.0002 in the momentum transfer squared range 0.001<-t<0.020 GeV 2 . In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

43 PARTICLE ACCELERATORS↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

Design of a Time-to-Digital Converter ASIC and a mini-DAQ system for the Phase-2 upgrade of the ATLAS Monitored Drift Tube detector

We present the second prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for High-Luminosity LHC operations. Compared to the first prototype, triple modular redundancy has been implemented for the configuration and flow control logic. Here, the total power consumption is increased by less than 10 mW while achieving the same time resolution and channel uniformity. A mini-DAQ system has been built to verify the front-end electronics chain with the new prototype together with other ASICs and boards in triggered mode. Cosmic ray tests with a small-diameter MDT chamber indicate that the configuration and data transmission of the readout electronics perform well. It is expected that this prototype design will be used in the final production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A position and pulse shape discriminant p -terphenyl detector module

We present the development of a neutron detector array module made with para-terphenyl, a bright, fast, n/γ discriminating crystalline organic scintillator. The module is comprised of 2 cm × 2 cm × 2 cm p-terphenyl crystals that have been optically coupled together to create a pseudo-bar module. While only relying on two photo detectors, the module is capable of distinguishing interactions between up to eight crystals. Furthermore, the module retains the p-terphenyl’s pulse shape discrimination (PSD) capability. Together this makes the pseudo-bar module a promising position-sensitive neutron detector. Here we present characteristics of the pseudo-bar module - its timing resolution as well as its pulse shape and position discrimination capabilities, and briefly discuss future plans for utilizing an array of pseudo-bar modules in a useful neutron detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STOPGAP—A time-of-flight extension for the Belle II TOP barrel PID system

The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system. Due to its mechanical design, the individual TOP modules do not overlap, leaving a gap of around 2 cm between them in the azimuthal direction. This leads to a 6%–9% drop in acceptance, depending on the track’s momentum. We propose a solution to remedy these gaps by instrumenting them with fast silicon detectors to directly measure the time-of-flight of traversing particles. We present here a simulation study discussing the performance requirements and the possible sensor technologies, and we demonstrate that such a project could be realized with novel, fast monolithic CMOS sensors, or alternatively AC-LGAD sensors, both of which are expected to reach MIP timing resolutions of down to 50 ps or better.

Hartbrich, Oskar↗

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A few-degree calorimeter for the future electron-ion collider

In this study, measuring the region 0.1 < Q 2 < 1.0 GeV 2 is essential to support searches for gluon saturation at the future Electron-Ion Collider. Recent studies have revealed that covering this region at the highest beam energies is not feasible with current detector designs, resulting in the so-called Q 2 gap. In this work, we present a design for the Few-Degree Calorimeter (FDC), which addresses this issue. The FDC uses SiPM-on-tile technology with tungsten absorber and covers the range of -4.6 < η < -3.6. It offers fine transverse and longitudinal granularity, along with excellent time resolution, enabling standalone electron tagging. Our design represents the first concrete solution to bridge the Q 2 gap at the EIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations↗

The upgraded summing NaI(Tl) (SuN++) absorption spectrometer

Simulations of astrophysical processes require a plethora of nuclear physics input. In particular, models of neutron-capture nucleosynthesis like the s, i, and r processes require β-decay information and experimentally constrained neutron-capture reaction rates. Past experiments with the 4π Summing NaI(Tl) (SuN) total absorption spectrometer have provided these physics quantities. Here, we outline an upgrade of SuN to SuN++, where 20 new segments (12 NaI(Tl) and 8 CeBr 3 ) have been integrated into the pre-existing SuN total absorption spectrometer to provide increased energy and time resolution in β-decay experiments. The details of the newly upgraded SuN++ total absorption spectrometer are discussed with results from the commissioning experiment at the Facility for Rare Isotope Beams (FRIB) utilizing a 70 Cu beam.

CeBr3↗

Improved light yield and growth of large-volume ultrafast single crystal scintillators Cs 2 ZnCl 4 and Cs 3 ZnCl 5

Due to their reported fast decay times, Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are promising candidates for detection of gamma rays and X-rays in high count rate and fast timing applications. In this work, we show that single crystals with better optical quality than previously demonstrated – and larger in size – can be grown via the vertical Bridgman method. Highly transparent Ø7 mm crystals of undoped Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are grown and measured to have light yields surpassing those previously reported, achieving 1980 ± 100 ph/MeV and 1460 ± 70 ph/MeV at 662 keV – a 55% and 232% improvement, respectively. We observe single-component scintillation decay times for both Cs 2 ZnCl 4 (1.66 ns) and Cs 3 ZnCl 5 (0.82 ns) and radioluminescence emission with maximum intensity at ~290 nm. Scalability of these materials is also evaluated based on growth of Ø22 mm crystals. Minimal cracking is observed, and the fast decay times are maintained at this size. Coincidence time resolution of 3 × 3 × 5 mm 3 and 7 × 7 × 10 mm 3 pixels cut from Ø22 mm Cs 2 ZnCl 4 are measured to be 148 ± 1 ps FWHM and 175 ± 1 ps FWHM, respectively. Here, the improved performance and ability to be fabricated in large sizes now place Cs 2 ZnCl 4 and Cs 3 ZnCl 5 on the map as potential contenders for radiation detection applications where BaF 2 – the most commonly used ultrafast inorganic scintillator – is typically considered.

36 MATERIALS SCIENCE↗

Total neutron cross-section measurement on CH with a novel 3D-projection scintillator detector

In order to extract neutrino oscillation parameters, long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section as a function of neutron energy is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 ± 0.05 barn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-fidelity kinetic theory-based approach for the prediction of particle attrition: Application to jet cup attrition system

The timescale difference between the “fast” flow dynamics of fluidized bed reactors and the relatively “slow” rate of particle degradation makes the direct computational prediction of attrition challenging. An approach to this challenge is a multi-fidelity strategy where a high fidelity model for the flow dynamics is coupled with a lower fidelity model for the long-time resolution of the bulk attrition of the reactor inventory. We implement this approach using high-fidelity kinetic theory simulations to calculate the flow dynamics which are post-processed to calculate the frequency and intensity of the particle-particle and particle-wall collisions (e.g. collision energy spectra). This is combined with the particle breakage properties to construct the coefficients for a low-fidelity model [e.g. Monazam et al., 2018, Powder Technology 340, p. 528-536]. Simulations are performed of a jet cup attrition system containing Canadian hematite (Monazam et al. 2018). Furthermore, these are first analyzed using the collision energy spectra. Quantitative predictions of the mass loss are made using a low-fidelity model derived from the collision-spectra and a calibrated material breakage coefficient. The results are found to compare favorably with the experimental measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Accelerating Quantum Materials Development with Advances in Transmission Electron Microscopy

Quantum materials are driving a technology revolution in sensing, communication, and computing, while simultaneously testing many core theories of the past century. Materials such as topological insulators, complex oxides, superconductors, quantum dots, color center-hosting semiconductors, and other types of strongly correlated materials can exhibit exotic properties such as edge conductivity, multiferroicity, magnetoresistance, superconductivity, single photon emission, and optical-spin locking. These emergent properties arise and depend strongly on the material’s detailed atomic-scale structure, including atomic defects, dopants, and lattice stacking. In this review, we describe how progress in the field of electron microscopy (EM), including in situ and in operando EM, can accelerate advances in quantum materials and quantum excitations. We begin by describing fundamental EM principles and operation modes. We then discuss various EM methods such as (i) EM spectroscopies, including electron energy loss spectroscopy (EELS), cathodoluminescence (CL), and electron energy gain spectroscopy (EEGS); (ii) four-dimensional scanning transmission electron microscopy (4D-STEM); (iii) dynamic and ultrafast EM (UEM); (iv) complementary ultrafast spectroscopies (UED, XFEL); and (v) atomic electron tomography (AET). We describe how these methods could inform structure–function relations in quantum materials down to the picometer scale and femtosecond time resolution, and how they enable precision positioning of atomic defects and high-resolution manipulation of quantum materials. For each method, we also describe existing limitations to solve open quantum mechanical questions, and how they might be addressed to accelerate progress. Among numerous notable results, our review highlights how EM is enabling identification of the 3D structure of quantum defects; measuring reversible and metastable dynamics of quantum excitations; mapping exciton states and single photon emission; measuring nanoscale thermal transport and coupled excitation dynamics; and measuring the internal electric field and charge density distribution of quantum heterointerfaces- all at the quantum materials’ intrinsic atomic and near atomic-length scale. Finally, we conclude by describing open challenges for the future, including achieving stable sample holders for ultralow temperature (below 10K) atomic-scale spatial resolution, stable spectrometers that enable meV energy resolution, and high-resolution, dynamic mapping of magnetic and spin fields. With atomic manipulation and ultrafast characterization enabled by EM, quantum materials will be poised to integrate into many of the sustainable and energy-efficient technologies needed for the 21st century.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural Transformation and Chemical Stability of a Shock-Compressed Insensitive High Explosive Single Crystal: Time-Resolved Raman Spectroscopy

Despite the considerable interest in insensitive high explosives (IHE) as a safer alternative to conventional high explosives, a good understanding of the low sensitivity of IHEs to shock initiation is lacking. In particular, real-time measurements to directly probe the molecular-level response of shock compressed IHE single crystals constitute an important need. To address this need, plate impact experiments were conducted to determine time-resolved changes in the Raman spectra of 1,1-diamino-2,2-dinitroethene (FOX-7) single crystals – a representative IHE crystal – shock compressed up to 20 GPa longitudinal stress. The Raman measurements examined vibrational frequencies from 800 cm-1 to 1500 cm-1 with 15 nanosecond time resolution and were conducted at several peak stresses. At 4 – 6 GPa, two new Raman peaks appeared, in addition to the original peaks, consistent with onset of the α' – ε structural transformation reported previously in static compression work. The measured spectra indicated completion of the transformation at 10 GPa. Raman data to 20 GPa showed neither additional transformations nor any indication of chemical decomposition. This finding, though consistent with recent continuum measurements, is in marked contrast to the chemical decomposition observed at lower stresses in shock compressed conventional high explosive single crystals. Our Raman results support the previous suggestion that strengthening of intra- and inter-molecular bonds, due to the α' – ε structural transformation, plays a significant role in the insensitivity of FOX-7 single crystals to shock initiation. In conclusion, the present work, in conjunction with previous static compression studies, provides the first experimental insight into the molecular-level response of a shock compressed IHE single crystal and can serve as a bench mark for theoretical studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗