Search NASA⌕ Search

SEARCH · Search NASA

Results for “Timing spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Time-Resolved X-ray Emission Spectroscopy and Synthetic High-Spin Model Complexes Resolve Ambiguities in Excited-State Assignments of Transition-Metal Chromophores: A Case Study of Fe-Amido Complexes

To fully harness the potential of abundant metal coordination complex photosensitizers, a detailed understanding of the molecular properties that dictate and control the electronic excited-state population dynamics initiated by light absorption is critical. In the absence of detectable luminescence, optical transient absorption (TA) spectroscopy is the most widely employed method for interpreting electron redistribution in such excited states, particularly for those with a charge-transfer character. The assignment of excited-state TA spectral features often relies on spectroelectrochemical measurements, where the transient absorption spectrum generated by a metal-to-ligand charge-transfer (MLCT) electronic excited state, for instance, can be approximated using steady-state spectra generated by electrochemical ligand reduction and metal oxidation and accounting for the loss of absorptions by the electronic ground state. However, the reliability of this approach can be clouded when multiple electronic configurations have similar optical signatures. Using a case study of Fe(II) complexes supported by benzannulated diarylamido ligands, we highlight an example of such an ambiguity and show how time-resolved X-ray emission spectroscopy (XES) measurements can reliably assign excited states from the perspective of the metal, particularly in conjunction with accurate synthetic models of ligand-field electronic excited states, leading to a reinterpretation of the long-lived excited state as a ligand-field metal-centered quintet state. Furthermore, a detailed analysis of the XES data on the long-lived excited state is presented, along with a discussion of the ultrafast dynamics following the photoexcitation of low-spin Fe(II)-N amido complexes using a high-spin ground-state analogue as a spectral model for the 5 T 2 excited state.

14 SOLAR ENERGY↗

40-in. OMS Kevlar(Registered Trademark) COPV S/N 007 Stress Rupture Test NDE

The presentation examines pretest nondestructive evaluation (NDE), including external/internal visual inspection, raman spectroscopy, laser shearography, and laser profilometry; real-time NDE including eddy current, acoustic emission (AE), and real-time portable raman spectroscopy; and AE application to carbon/epoxy composite overwrapped pressure vessels.

Saulsberry, Regor↗

Photophysical and Time‐resolved Infrared Properties of Long‐Lived Rhenium(I) 4,5‐Diazafluorene Tricarbonyl Chromophores

This report investigates the synthesis, structural characterization, fundamental molecular photophysics, electrochemistry, UV-Vis spectroelectrochemistry, and time-resolved infrared spectroscopic properties of eight [fac-Re(dafR)(CO) 3 L] 0/+ complexes, where R=ethyl [(dedaf); 1, 3, 5, 7] or H [(dafH); 2, 4, 6, 8] and L=Cl− (1, 2), imidazole [(Im); 3, 4], 4-ethylpyridine [(4-Etpy); 5, 6], or pyridine [(py); 7, 8]. Universally, 1–8 yield higher energy photoluminescence (PL) emission bands and higher PL quantum yields (up to 53 %) than the classic 2,2’-bipyridine (bpy) and 1,10-phenanthroline (phen) ligated Re(I) tricarbonyl complexes. The excited state lifetimes of 1–8 lie between those corresponding to the bpy and phen derivatives, ranging from 120 and 1300 ns at room temperature. Combinations of reductive UV-Vis spectroelectrochemistry, transient absorption spectroscopy, and time-resolved infrared spectroscopy consistently assigned the lowest excited states in 1–8 being of metal-to-ligand charge transfer (MLCT) character. These new ReI MLCT chromophores follow classic energy gap law behavior and possess the characteristics necessary for serving as valuable photosensitizers suitable to energize excited state electron and energy transfer photochemistry.

Charge transfer↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Time, momentum, and energy resolved pump-probe tunneling spectroscopy of two-dimensional electron systems

Abstract Real-time probing of electrons can uncover intricate relaxation mechanisms and many-body interactions in strongly correlated materials. Here, we introduce time, momentum, and energy resolved pump-probe tunneling spectroscopy (Tr-MERTS). The method allows the injection of electrons at a particular energy and observation of their subsequent decay in energy-momentum space. Using Tr-MERTS, we visualize electronic decay processes, with lifetimes from tens of nanoseconds to tens of microseconds, in Landau levels formed in a GaAs quantum well. Although most observed features agree with simple energy-relaxation, we discovered a splitting in the nonequilibrium energy spectrum in the vicinity of a ferromagnetic state. An exact diagonalization study suggests that the splitting arises from a maximally spin-polarized state with higher energy than a conventional equilibrium skyrmion. Furthermore, we observe time-dependent relaxation of the splitting, which we attribute to single-flipped spins forming skyrmions. These results establish Tr-MERTS as a powerful tool for studying the properties of a 2DES beyond equilibrium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Does Selectivity of Molecular Catalysts Change with Time? Polymerization Imaged by Single‐Molecule Spectroscopy

Abstract The chemoselectivity of molecular catalysts underpins much of modern synthetic organic chemistry. However, little is known about the selectivity of individual catalysts because this single‐catalyst‐level behavior is hidden by the bulk catalytic behavior. Here, for the first time, the selectivity of individual molecular catalysts for two different reactions is imaged in real time at the single‐catalyst level. This imaging is achieved through fluorescence microscopy paired with spectral probes that produce a snapshot of the instantaneous chemoselectivity of a single catalyst for either a single‐chain‐elongation or a single‐chain‐termination event during ruthenium‐catalyzed polymerization. Superresolution imaging of multiple selectivity events, each at a different single‐molecular ruthenium catalyst, indicates that catalyst selectivity may be unexpectedly spatially and time‐variable.

Garcia, IV, Antonio↗

Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients

We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.

(S2-FT-IR)↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

Substrate birefringence as a source of artifacts in spintronic THz emission spectra

Terahertz (THz) emission from spintronic THz emitters (STEs) has been extensively studied, both for its potential application in THz technologies and as a tool for probing spin dynamics, conductivity, and crystal anisotropy via time-domain THz spectroscopy. However, substrate birefringence can modify the emitted THz polarization, distorting the measured spectra and leading to potential misinterpretation of the results. While some aspects of substrate birefringence on THz emission have been studied in the time domain, its effects on THz spectra have not been discussed in detail. In the THz emission spectrum from STEs, we observe distinct spectral signatures that depend on sample orientation. To understand these signatures, we use STEs grown on c-cut sapphire and systematically vary the orientation of a (100) rutile TiO 2 window in both pump-through and THz-through geometries to identify the birefringence-induced effects. These findings demonstrate that substrate birefringence plays a critical role in the emitted THz spectrum and must be carefully considered in the analysis of time-domain THz spectroscopy data. We also show that artifacts from smaller birefringence can have a more misleading effect on the THz spectra.

Shrestha, Shreya [Univ. of Delaware, Newark, DE (U↗

A Mars 2020 Perseverance SuperCam Perspective on the Igneous Nature of the Máaz Formation at Jezero Crater, Mars

The Mars2020 Perseverance rover landed in Jezero crater in February 2020,and first encountered the Máaz formation (or Crater floor-fractured rough(Cf-fr) unit previously mapped based on orbital data[1]).In this study, we use data from the SuperCam instrument(SCAM) to show that the Máaz formation has an igneous origin. SuperCam is a remote-sensing instrument onboard Perseverance, and investigates the texture, mineralogy, and chemistry of rocks and soils, as well as atmospheric features [2,3]. SuperCam comprises the Remote Micro Imager (RMI) to provide high-resolution images, laser-induced breakdown spectroscopy (LIBS)to investigate the major and minor element chemistry of materials, Raman, and passive visible-near infrared (VISIR) spectroscopy to analyze the mineralogy of targets, and time-resolved luminescence spectroscopy (TRLS)to measure organic fluorescence and inorganic luminescence. In addition, the microphone (MIC) can constrain the rock hardness through measurements of the shockwave of LIBS shots. In this study, we use LIBS-based major-oxide compositions (MOC),quantified using the calibration in [2].

Mars 2020↗

Studies of surface adsorbate electronic structure and femtochemistry at the fundamental length and time scales. Final report

The electronic structure and ultrafast (10-15 s-femtosecond timescale) electron dynamics were investigated for clean and atom/molecule covered metal surfaces. The studies were performed by scanning tunneling microscopy (STM) to measure the structure of adsorbed atoms and molecules on metal surfaces, and to investigate their electronic properties. The electronic structure of the observed molecular networks was calculated by electronic structure theory in collaboration with Prof. Jin Zhao, who is a long-time collaborator, a Professor at the University of Science and Technology of China, and holds an Adjunct Professorship at the University of Pittsburgh. We also investigated the electronic properties of C60 molecules when they are templated by corrugated black phosphorous surfaces. We found unexpected charge delocalization that is enabled by the templating. This research was done in collaboration with Professor Min Feng at the Wuhan University, and who also holds an Adjunct Professorship at the University of Pittsburgh. Moreover, the electronic structure and electron dynamics in metal surfaces were investigated by time-resolved photoemission electron spectroscopy. The focus of ultrafast spectroscopy has been on the plasmonic response of silver surfaces. One direction has been to develop multidimensional (energy, momentum, and time) photoelectron spectroscopy of the coherent response of solid surfaces. This method was applied to study the collective electron excitations known generally as plasmons, which screen optical fields from penetration into metals. Although this collective response has been known for more than 60 years and is used extensively to deposit optical energy into metals, how this happens is poorly known. We investigated the plasmonic response of silver at the point where the dielectric response passes through zero and bulk plasmon is excited by light. We discovered that the plasmon excitation decays by exciting electrons from the Fermi level of a metal, which is contrary to what is believed in the plasmonic science community. This research has been performed in collaboration with Dr. Marcel Reutzel, who was a postdoctoral fellow working on this research at the University of Pittsburgh, and now has a faculty position at the University of Göttingen in Germany. Prof. Branko Gumhalter from the Institute of Physics in Zagreb contributed on the theory of plasmonic decay processes. Furthermore, we investigated the Floquet engineering of electronic bands in metals leading to multiphoton photoemission and above threshold photoemission. Finally, we demonstrated that it is possible to change the electronic structure of metals by application of optical fields. Our studies indicated that this happens on subfemtosecond time scale and could potentially be used in ultrafast information processing and quantum computation. Related document information

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advancing electrochemical impedance analysis through innovations in the distribution of relaxation times method

Electrochemical impedance spectroscopy (EIS) is a key tool across various scientific disciplines, including energy sciences, chemistry, and biology, enabling the analysis of electrochemical systems. However, conventional methods for interpreting EIS data are often complex and model dependent. The distribution of relaxation times (DRT) offers a non-parametric approach that simplifies the interpretation process by providing a timescale interpretation of EIS data. This article provides a comprehensive review of current methods for DRT inversion. Additionally, a survey of practitioners highlights key challenges in the field. Here, the findings underscore the need for standardized DRT analysis and benchmarks, as well as the development of automated analysis tools. These advancements would improve the usability and interpretability of EIS data. Ultimately, implementing these improvements could not only propel the field forward but also expand the application of DRT in scientific research by making it accessible to a broader range of researchers, including those without specialized expertise in programming or statistics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The SuperCam Instrument Suite on the Mars 2020 Rover: Science Objectives and Mast-Unit Description

On the NASA 2020 rover mission to Jezero crater, the remote determination of the texture, mineralogy and chemistry of rocks is essential to quickly and thoroughly characterize an area and to optimize the selection of samples for return to Earth. As part of the Perseverance payload, SuperCam is a suite of five techniques that provide critical and complementary observations via Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), visible and near-infrared spectroscopy (VISIR), high-resolution color imaging (RMI), and acoustic recording (MIC). SuperCam operates at remote distances, primarily 2–7 m, while providing data at sub-mm to mm scales. We report on SuperCam’s science objectives in the context of the Mars 2020 mission goals and ways the different techniques can address these questions. The instrument is made up of three separate subsystems: the Mast Unit is designed and built in France; the Body Unit is provided by the United States; the calibration target holder is contributed by Spain, and the targets themselves by the entire science team. This publication focuses on the design, development, and tests of the Mast Unit; companion papers describe the other units. The goal of this work is to provide an understanding of the technical choices made, the constraints that were imposed, and ultimately the validated performance of the flight model as it leaves Earth, and it will serve as the foundation for Mars operations and future processing of the data.

47 OTHER INSTRUMENTATION↗

The Fast-Track Water Oxidation Channel on BiVO 4 Opened by Nitrogen Treatment

BiVO 4 is one of the most promising photoanode materials for water-splitting systems. Nitrogen incorporation into a BiVO 4 surface overcomes the known bottleneck in its charge-transfer kinetics into the electrolyte. We explored the role of nitrogen in the surface charge recombination and charge-transfer kinetics by employing transient photocurrent spectroscopy at the time scale of surface recombination and water oxidation kinetics, transient absorption spectroscopy, and X-ray photoelectron spectroscopy. We attributed the activity enhancement mechanism to the accelerated V 5+ /V 4+ redox process, in which incorporated nitrogen suppresses a limiting surface recombination channel by increasing the oxygen vacancies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Observation of Bandgap Oscillations Induced by Optical Phonons in Hybrid Lead Iodi.de Perovskites

Hybrid organic-inorganic perovskites such as methylammonium lead iodide have emerged as promising semiconductors for energy-relevant applications. The interactions between charge carriers and lattice vibrations, giving rise to polarons, have been invoked to explain some of their extraordinary optoelectronic properties. Here, time-resolved optical spectroscopy is performed, with off-resonant pumping and electronic probing, to examine several representative lead iodide perovskites. The temporal oscillations of electronic bandgaps induced by coherent lattice vibrations are reported, which is attributed to antiphase octahedral rotations that dominate in the examined 3D and 2D hybrid perovskites. The off-resonant pumping scheme permits a simplified observation of changes in the bandgap owing to the A(g) vibrational mode, which is qualitatively different from vibrational modes of other symmetries and without increased complexity of photogenerated electronic charges. The work demonstrates a strong correlation between the lead-iodide octahedral framework and electronic transitions, and provides further insights into the manipulation of coherent optical phonons and related properties in hybrid perovskites on ultrafast timescales.

coherent optical phonons↗

Remote Raman Spectroscopy of Minerals at Elevated Temperature Relevant to Venus Exploration

We have used a remote time-resolved telescopic Raman system equipped with 532 nm pulsed laser excitation and a gated intensified CCD (ICCD) detector for measuring Raman spectra of a number of minerals at high temperature to 970 K. Remote Raman measurements were made with samples at 9-meter in side a high-temperature furnace by gating the ICCD detector with 2 micro-sec gate to minimize interference from blackbody emission from mineral surfaces at high temperature as well as interference from ambient light. A comparison of Raman spectra of gypsum (CaSO4.2H2O), dolomite (CaMg(CO3)2), and olivine (Mg2Fe2-xSiO4), as a function of temperature shows that the Raman lines remains sharp and well defined even in the high-temperature spectra. In the case of gypsum, Raman spectral fingerprints of CaSO4.H2O at 518 K were observed due to dehydration of gypsum. In the case of dolomite, partial mineral dissociation was observed at 973 K at ambient pressure indicating that some of the dolomite might survive on Venus surface that is at approximately 750 K and 92 atmospheric pressure. Time-resolved Raman spectra of low clino-enstatite (MgSiO3) measured at 75 mm from the sample in side the high-temperature furnace also show that the Raman lines remains sharp and well defined in the high temperature spectra. These high-temperature remote Raman spectra of minerals show that time-resolved Raman spectroscopy can be used as a potential tool for exploring Venus surface mineralogy at shorter (75 mm) and long (9 m) distances from the samples both during daytime and nighttime. The remote Raman system could also be used for measuring profiles of molecular species in the dense Venus atmosphere during descent as well as on the surface.

Sharma, Shiv K.↗