Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient load analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Multi-Fidelity Scheme for Accelerating 4D Finite Element Analysis for Mircoreactors

Next-generation microreactors are currently being designed to be operated terrestrial and extraterrestrial for remote surface power production. These systems will provide an alternative source of carbon-free energy that is versatile and can be utilized for various applications. These applications of microreactors have prompted the usage of high-fidelity unstructured finite element (FE) based approaches to provide time-dependent solutions for multiple physics fields. Computing these high-fidelity (4-D) solutions for multiple design iterations, physics fields, and transient events requires an immense computational cost. These high-fidelity solutions are computational expensive and the cost can be reduced through the implementation of less accurate low-fidelity solutions. Unlike the current fleet of commercial nuclear reactors, these next-gen systems present challenges due to the material and physical limitations required. Due to these constraints, the brute force technique of parameterizing important system characteristics determines whether a design meets the project objective. A system such as a nuclear reactor could have thousands of design parameters that affect system performance. In order to analyze the entire parameter space of such a complex system would require millions of CPU hours and countless design iterations. This costly approach is not practical due to regulatory and budget limitations. In this proposal, an approach that utilizes hybrid high-fidelity and low-fidelity FE models to reduce the computational cost of evaluating these applications in 4-D will be presented. The accuracy of the high-fidelity model and the computational efficiency of the low-fidelity model are taken advantage of to produce a solution that closely resembles the full order high-fidelity solution. By utilizing an unconverged coarse FE mesh, operation limits such as temperature, structural loading, etc., can be evaluated in an accelerated fashion and then can be spatially interpolated onto a finer mesh. The resulting error arising from the coarse mesh can be mitigated with a discrepancy function that actively quantifies and corrects the error in the coarse solution. This discrepancy function can be periodically updated with high-fidelity calculations across the temporal domain thus requiring less iterations on the fine mesh. As a result, the computational cost can be reduced for the evaluation and design iteration of microreactors. The proposal for this research contains three sections: Section 2 provides a literature review, Section 3 outlines the methodology for the proposed multi-fidelity scheme, and Section 4 displays preliminary results of the proposed research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrated Sensing and Controls for Coal Gasification - Development of Model-Based Controls for GE's Gasifier and Syngas Cooler (Final Technical Report)

This report summarizes the achievements and final results of this program. The objective of this program is to develop a comprehensive systems approach to integrated design of sensing and control systems for an Integrated Gasification Combined Cycle (IGCC) plant, using advanced model-based techniques. In particular, this program is focused on the model-based sensing and control system design for the core gasification section of an IGCC plant. The overall approach consists of (i) developing a first-principles physics-based dynamic model of the gasification section, (ii) performing model-reduction where needed to derive low-order models suitable for controls analysis and design, (iii) developing a sensing system solution combining online sensors with model-based estimation for important process variables not measured directly, and (iv) optimizing the steady-state and transient operation of the plant for normal operation as well as for startup using model predictive controls (MPC). Initially, available process unit models were implemented in a common platform using Matlab/Simulink{reg_sign}, and appropriate model reduction and model updates were performed to obtain the overall gasification section dynamic model. Also, a set of sensor packages were developed through extensive lab testing and implemented in the Tampa Electric Company IGCC plant at Polk power station in 2009, to measure temperature and strain in the radiant syngas cooler (RSC). Plant operation data was also used to validate the overall gasification section model. The overall dynamic model was then used to develop a sensing solution including a set of online sensors coupled with model-based estimation using nonlinear extended Kalman filter (EKF). Its performance in terms of estimating key unmeasured variables like gasifier temperature, carbon conversion, etc., was studied through extensive simulations in the presence sensing errors (noise and bias) and modeling errors (e.g. unknown gasifier kinetics, RSC fouling). In parallel, an MPC solution was initially developed using ideal sensing to optimize the plant operation during startup pre-heating as well as steady state and transient operation under normal high-pressure conditions, e.g. part-load, base-load, load transition and fuel changes. The MPC simulation studies showed significant improvements both for startup pre-heating and for normal operation. Finally, the EKF and MPC solutions were coupled to achieve the integrated sensing and control solution and its performance was studied through extensive steady state and transient simulations in the presence of sensor and modeling errors. The results of each task in the program and overall conclusions are summarized in this final report.

01 COAL, LIGNITE, AND PEAT↗

Optimizing Low Temperature Diesel Combustion (LTC-D) "FreedomCAR and Vehicle Technologies Program Solicitation for University Research and Graduate Automotice Technology Education (GATE) Centers of Excellence"

The engine industry is currently facing severe emissions mandates. Pollutant emissions from mobile sources are a major source of concern. For example, US EPA mandates require emissions of particulate and nitrogen oxides (NOx) from heavy-duty diesel engine exhaust to drop at least 90 percent between 1998 and 2010. Effective analysis of the combustion process is required to guide the selection of technologies for future development since exhaust after-treatment solutions are not currently available that can meet the required emission reduction goals. The goal of this project is to develop methods to optimize and control Low Temperature Combustion Diesel technologies (LTC-D) that offers the potential of nearly eliminating engine NOx and particulate emissions at reduced cost over traditional methods by controlling pollutant emissions in-cylinder. The work was divided into 5 Tasks, featuring experimental and modeling components: 1.) Fundamental understanding of LTC-D and advanced model development, 2.) Experimental investigation of LTC-D combustion control concepts, 3.) Application of detailed models for optimization of LTC-D combustion and emissions, 4.) Impact of heat transfer and spray impingement on LTC-D combustion, and 5.) Transient engine control with mixed-mode combustion. As described in the final report (December 2008), outcomes from the research included providing guidelines to the engine and energy industries for achieving optimal low temperature combustion operation through using advanced fuel injection strategies, and the potential to extend low temperature operation through manipulation of fuel characteristics. In addition, recommendations were made for improved combustion chamber geometries that are matched to injection sprays and that minimize wall fuel films. The role of fuel-air mixing, fuel characteristics, fuel spray/wall impingement and heat transfer on LTC-D engine control were revealed. Methods were proposed for transient engine operation during load and speed changes to extend LTC-D engine operating limits, power density and fuel economy. Low emissions engine design concepts were proposed and evaluated.

33 ADVANCED PROPULSION SYSTEMS↗

A study of the relationship between lithium ion transport and structure and dynamic behavior in polyethylene oxide-melt/LiClO 4 battery electrolytes.

An experimental study of the canonical SPE (“solid” polymer electrolyte) for rechargeable “rocking chair” lithium/polymer batteries, viz. LiClO4 dissolved in molten poly(ethylene oxide) (PEO), was carried out under DOE grant FG02-04ER15573. In this study, an improved understanding was obtained of the relationship between lithium ion transport and polymer behavior in these SPEs. Among other applications, these sturdy temperature-tolerant and powerful light-weight batteries would be used in electric and electric-hybrid vehicles to reduce greenhouse gas emissions, to store unused electrical energy for peak demand loads and as compact, light-weight energy sources for aircraft and spacecraft. During the period of the grant, the American/Canadian partnership company “Avestor” fabricated and successfully demonstrated a telecommunications application of shoe-box sized batteries and representatives from Avestor visited our research lab at UNLV. They found our results interesting and relevant to their work and invited us to visit Avestor and present a talk about our efforts at UNLV. Unfortunately Avestor (who was scheduled to build a battery production facility in Apex, Nevada just North of Las Vegas) folded before the visit could be made. In the grant work, two well characterized PEO samples having molar masses distinctly below and distinctly above the melt entanglement molar mass were used and three laser light scattering techniques employed as the principal noninvasive methods of investigating liquid poly(ethylene oxide) (PEO)/LiClO4 SPEs. These investigations considered the effects of temperature, dissolved salt concentration and scattering wavevector on SPE behavior. Classical or “static” light scattering and the dynamic light scattering techniques of photon correlation spectroscopy (PCS) and Fabry-Perot interferometry (FPI) were used to study SPE static, low frequency and high frequency dynamic behaviors, respectively. Static measurements provided information about system structure while low frequency results provided information about slower (0.1-10s) more global behavior and high frequency results provided information about faster (~10-11s) more local behavior. In addition, viscometry, rheometry and thermal analysis provided vital complementary results. It was found that liquid PEO/lithium salt solutions for both PEO molar masses are random transient physical networks with measureable network and intra-network relaxation times using PCS and FPI. Thus novel and informative results addressing both large scale and small scale behavior were obtained. For example, the high sensitivity of liquid PEO electrolytes to the presence of presumably undesirable trace amounts of residual water and/or methanol was clearly evident in PCS measurements. In “unentangled” melts the activation energies for diffusive relaxation in liquid PEO/lithium salt electrolytes measured using PCS and the activation energies for viscous flow in these systems determined by viscometry were identical while thermal analyses detected no phase transitions for these systems. These results reinforced an earlier assumption that the liquid PEO/LiClO4 system is a liquid polymer “bimorph” (to our knowledge the first of its kind to be reported) with the network comprising one form of the polymer while the second form corresponds to that of a viscous damping liquid. At a given temperature, FPI characteristic relaxation times for local, between-chain motions were consistent with PCS results so that increases with increasing salt concentration were accompanied by increases in the elastic modulus and corresponding increases in system stiffness. Note that corresponding decreases in polymer segmental mobility are accompanied by reduced ion diffusivity. For entangled melts, PCS network relaxations were again observed and these systems were also considered to be bimorphs even though diffusion activation energies were distinctly larger than viscous flow activation energies - a difference attributed to the effects of entanglement. Moreover, SLS measurements revealed entangled melts to be “percolation gels” with a measured fractal dimension of about 2 and static correlation lengths that increased gradually from about 500 nm to about 700 nm with increasing salt concentration. Meanwhile, rheological measurements found these polymer/salt melts to behave simply as liquids. FPI measurements have not yet been made on these entangled PEO melts.

25 ENERGY STORAGE↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analytical expressions for the gate utilization factors of passive multiplicity counters including signal build-up

In the realm of nuclear safeguards, passive neutron multiplicity counting using shift register pulse train analysis to nondestructively quantify Pu in product materials is a familiar and widely applied technique. The approach most commonly taken is to construct a neutron detector consisting of {sup 3}He filled cylindrical proportional counters embedded in a high density polyethylene moderator. Fast neutrons from the item enter the moderator and are quickly slowed down, on timescales of the order of 1-2 {micro}s, creating a thermal population which then persists typically for several 10's {micro}s and is sampled by the {sup 3}He detectors. Because the initial transient is of comparatively short duration it has been traditional to treat it as instantaneous and furthermore to approximate the subsequent capture time distribution as exponential in shape. With these approximations simple expressions for the various Gate Utilization Factors (GUFs) can be obtained. These factors represent the proportion of time correlated events i.e. Doubles and Triples signal present in the pulse train that is detected by the coincidence gate structure chosen (predelay and gate width settings of the multiplicity shift register). More complicated expressions can be derived by generalizing the capture time distribution to multiple time components or harmonics typically present in real systems. When it comes to applying passive neutron multiplicity methods to extremely intense (i.e. high emission rate and highly multiplying) neutron sources there is a drive to use detector types with very fast response characteristics in order to cope with the high rates. In addition to short pulse width, detectors with a short capture time profile are also desirable so that a short coincidence gate width can be set in order to reduce the chance or Accidental coincidence signal. In extreme cases, such as might be realized using boron loaded scintillators, the dieaway time may be so short that the build-up (thermalization transient) within the detector cannot be ignored. Another example where signal build-up might be observed is when a {sup 3}He based system is used to track the evolution of the time correlated signal created by a higher multiplying item within a reflective configuration such as the measurement of a spent fuel assembly. In this work we develop expressions for the GUFs which include signal build-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Metal Fuel Implications on Severe Accident Scenarios

Superior steady-state irradiation performance of metal fuel has been demonstrated, and metal fuel has been the choice for recent sodium-cooled fast reactor designs, e.g. PRISM, SAFR, 4S, TWR, PGSFR, and so on. Metal fuel also has excellent transient capabilities. The metal fuel itself does not impose any restrictions on transient operations or load-following capabilities. Metal fuel has benign run beyond cladding breach (RBCB) performance characteristics. Because metal fuel is compatible with sodium, there is no reaction product and the fuel loss is practically zero. Metal fuel is expected to be very reliable. However, even if unforeseen fuel pin failure occurs, it will simply release gases and does not cause failure propagation to neighboring pins. The eutectic formation temperature between the fuel and the cladding has been considered a critical parameter for the metal fuel pin design. The onset of fuel-cladding eutectic formation starts in the 700-725 deg. C temperature range, depending on the fuel alloy and cladding types. However, at this onset temperature, not much interaction occurs. In fact, even at 100 deg. C above the eutectic temperature, the eutectic penetration into the cladding is minimal in one hour. Only at much higher temperatures, close to the fuel melting point itself, the eutectic penetration into cladding becomes rapid. Therefore, the eutectic formation is not a primary safety concern during transient overpower conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of the ANL Plant Dynamics Code and Control Strategies for the Supercritical Carbon Dioxide Brayton Cycle and Code Validation with Data from the Sandia Small-Scale Supercritical Carbon Dioxide Brayton Cycle Test Loop

Significant progress has been made in the ongoing development of the Argonne National Laboratory (ANL) Plant Dynamics Code (PDC), the ongoing investigation and development of control strategies, and the analysis of system transient behavior for supercritical carbon dioxide (S-CO 2 ) Brayton cycles. Several code modifications have been introduced during FY2011 to extend the range of applicability of the PDC and to improve its calculational stability and speed. A new and innovative approach was developed to couple the Plant Dynamics Code for S-CO 2 cycle calculations with SAS4A/SASSYS-1 Liquid Metal Reactor Code System calculations for the transient system level behavior on the reactor side of a Sodium-Cooled Fast Reactor (SFR) or Lead-Cooled Fast Reactor (LFR). The new code system allows use of the full capabilities of both codes such that whole-plant transients can now be simulated without additional user interaction. Several other code modifications, including the introduction of compressor surge control, a new approach for determining the solution time step for efficient computational speed, an updated treatment of S-CO 2 cycle flow mergers and splits, a modified enthalpy equation to improve the treatment of negative flow, and a revised solution of the reactor heat exchanger (RHX) equations coupling the S-CO 2 cycle to the reactor, were introduced to the PDC in FY2011. All of these modifications have improved the code computational stability and computational speed, while not significantly affecting the results of transient calculations. The improved PDC was used to continue the investigation of S-CO 2 cycle control and transient behavior. The coupled PDC-SAS4A/SASSYS-1 code capability was used to study the dynamic characteristics of a S-CO 2 cycle coupled to a SFR plant. Cycle control was investigated in terms of the ability of the cycle to respond to a linear reduction in the electrical grid demand from 100% to 0% at a rate of 5%/minute. It was determined that utilization of turbine throttling control below 50% load improves the cycle efficiency significantly. Consequently, the cycle control strategy has been updated to include turbine throttle valve control. The new control strategy still relies on inventory control in the 50%-90% load range and turbine bypass for fine and fast generator output adjustments, but it now also includes turbine throttling control in the 0%-50% load range. In an attempt to investigate the feasibility of using the S-CO 2 cycle for normal decay heat removal from the reactor, the cycle control study was extended beyond the investigation of normal load following. It was shown that such operation is possible with the extension of the inventory and the turbine throttling controls. However, the cycle operation in this range is calculated to be so inefficient that energy would need to be supplied from the electrical grid assuming that the generator could be capable of being operated in a motoring mode with an input electrical energy from the grid having a magnitude of about 20% of the nominal plant output electrical power level in order to maintain circulation of the CO 2 in the cycle. The work on investigation of cycle operation at low power level will be continued in the future. In addition to the cycle control study, the coupled PDC-SAS4A/SASSYS-1 code system was also used to simulate thermal transients in the sodium-to-CO 2 heat exchanger. Several possible conditions with the potential to introduce significant changes to the heat exchanger temperatures were identified and simulated. The conditions range from reactor scram and primary sodium pump failure or intermediate sodium pump failure on the reactor side to pipe breaks and valve malfunctions on the S-CO 2 side. It was found that the maximum possible rate of the heat exchanger wall temperature change for the particular heat exchanger design assumed is limited to ±7 C/s for less than 10 seconds. Modeling in the Plant Dynamics Code has been compared with available data from the Sandia National Laboratories (SNL) small-scale S-CO 2 Brayton cycle demonstration that is being assembled in a phased approach currently at Barber-Nichols Inc. and at SNL in the future. The available data was obtained with an earlier configuration of the S-CO 2 loop involving only a single-turbo-alternator-compressor (TAC) instead of two TACs, a single low temperature recuperator (LTR) instead of both a LTR and a high temperature recuperator (HTR), and fewer than the later to be installed full set of electric heaters. Due to the absence of the full heating capability as well as the lack of a high temperature recuperator providing additional recuperation, the temperature conditions obtained with the loop are too low for the loop conditions to be prototypical of the S-CO 2 cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY23 Update: Aerosol Sampling for the Canister Deposition Field Demonstration

This report describes the results of preliminary testing of aerosol monitoring equipment that will be used to continuously monitor the aerosol source term for the multi-year Canister Deposition Field Demonstration (CDFD). These data are required inputs for the development and validation of models for the deposition of dust and potentially corrosive salts on the surface of spent nuclear fuel (SNF) dry storage canisters. Surface salt loads correlate with the extent of corrosion damage on a metal surface, and potentially to the likelihood and timing of initiation of stress corrosion cracks. Aerosols will be monitored at the CDFD site using three instruments. A Dekati ® ELPI+ cascade impactor will be used for real-time monitoring of aerosol particle sizes. It will also collect dust in 14 size bins on impactor targets that can be chemically analyzed to determine the soluble salts present as a function of particle size. However, this instrument can only measure dried aerosols, with a diameter of <10 µm. The second instrument is a Topas laser particle size spectrometer, which provides real-time monitoring of aerosol particle sizes up to ~40 µm in size. It monitors both the ambient (potentially deliquesced) aerosol particle size distributions required for the dust deposition models and the distributions of the equivalent dried particles, allowing correlation with the Dekati ® data. However, it does not discriminate between inert dust particles and salt aerosols, and it does not retain samples of the different particle sizes for later analysis. The third instrument that will monitor aerosols at the CDFD site is a Clean Air Status and Trends Network (CASTNET) tower, which uses a multiple canister system to collect weekly samples for analysis to total suspended aerosol particle compositions and atmospheric gas concentrations. This status report describes work in FY23 to develop the capabilities for using these tools. In two training exercises, the cascade impactor and laser particle sizer were deployed in two different testing environments, one indoor and one outdoor. For the cascade impactor, the tests provided opportunities for the operators to familiarize themselves with impactor substrate preparation, and post-test sample removal and analysis. For the laser particle sizer, the tests were used to evaluate different instrument parameters, to determine the most appropriate settings for capturing transient events. Data and samples were collected for weeks to months for each test, and the results are presented here. In addition to the preliminary testing, contracts were developed with WSP Analytical Labs for sample preparation and analysis of the cascade impactor samples. The impactor tower from outdoor test was delivered to WSP and used to train the staff there in disassembly, sample extraction, sample analysis, and tower reassembly with new target substrates. These are tasks that WSP will be performing routinely for the CDFD project. The CASTNET system cannot be purchased or tested until an actual site has been selected for the CDFD test. Work for this FY has been restricted to preparation of contracts for purchasing the CASTNET tower, and for sample analysis, once the tower is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of plant control strategies for the supercritical C0{sub 2}Brayton cycle for a sodium-cooled fast reactor using the plant dynamics code.

The development of a control strategy for the supercritical CO{sub 2} (S-CO{sub 2}) Brayton cycle has been extended to the investigation of alternate control strategies for a Sodium-Cooled Fast Reactor (SFR) nuclear power plant incorporating a S-CO{sub 2} Brayton cycle power converter. The SFR assumed is the 400 MWe (1000 MWt) ABR-1000 preconceptual design incorporating metallic fuel. Three alternative idealized schemes for controlling the reactor side of the plant in combination with the existing automatic control strategy for the S-CO{sub 2} Brayton cycle are explored using the ANL Plant Dynamics Code together with the SAS4A/SASSYS-1 Liquid Metal Reactor (LMR) Analysis Code System coupled together using the iterative coupling formulation previously developed and implemented into the Plant Dynamics Code. The first option assumes that the reactor side can be ideally controlled through movement of control rods and changing the speeds of both the primary and intermediate coolant system sodium pumps such that the intermediate sodium flow rate and inlet temperature to the sodium-to-CO{sub 2} heat exchanger (RHX) remain unvarying while the intermediate sodium outlet temperature changes as the load demand from the electric grid changes and the S-CO{sub 2} cycle conditions adjust according to the S-CO{sub 2} cycle control strategy. For this option, the reactor plant follows an assumed change in load demand from 100 to 0 % nominal at 5 % reduction per minute in a suitable fashion. The second option allows the reactor core power and primary and intermediate coolant system sodium pump flow rates to change autonomously in response to the strong reactivity feedbacks of the metallic fueled core and assumed constant pump torques representing unchanging output from the pump electric motors. The plant behavior to the assumed load demand reduction is surprising close to that calculated for the first option. The only negative result observed is a slight increase in the intermediate inlet sodium temperatures by about 10 C. This temperature rise could presumably be precluded or significantly reduced through fine adjustment of the control rods and pump motors. The third option assumes that the reactor core power and primary and intermediate system flow rates are ideally reduced linearly in a programmed fashion that instantaneously matches the prescribed load demand. The calculated behavior of this idealized case reveals a number of difficulties because the control strategy for the S-CO{sub 2} cycle overcools the reactor potentially resulting in the calculation of sodium bulk freezing and the onset of sodium boiling. The results show that autonomous SFR operation may be viable for the particular assumed load change transient and deserves further investigation for other transients and postulated accidents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A new model for the dynamic of criticality excursions in fissile solutions - 14446

A recent international inter-code comparison exercise for criticality excursion analysis demonstrated that the transient criticality codes participating the exercise are showed to reproduce well the initial peak power compared with measurements performed with TRACY and SILENE reactors. However the oscillatory behavior after peak power is less well reproduced. The integrated behavior in term of energy release is quite well reproduced. The recent experiments performed with TRACY JAEA's reactor and the analytic interpretation of void clustering during prompt critical have suggested a simplified vibration model of a damped oscillator. Finally a recent ICNC paper by present authors offered a perfect correlation between peak pressure and peak power. Owing to these three facts the present paper aims at proposing a new system of equations for the dynamic of a critical excursion taking into account gas bubble generation after exceeding the solubility threshold of dissolved radiolytic gas. The model explains why the simple vibration model of the JAEA school fairly represent pressure dynamic records at moderate peak pressure as measured with SILENE reactor. Also, an important parameter of the proposed model, namely the rate of transfer from dissolved gas to gas bubbles, is fixed by the correlation between peak pressure and peak power. Thus the model has one less tunable parameter and can predict a large range of critical low pressure excursions. After presentation of the model and discussion of some of its important features, some numerical simulations are made based upon SILENE and TRACY transient experiments ranging from tenths of kPa to several bars and comparisons are presented between calculated results and experimentally recorded one's. (authors)

42 ENGINEERING↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Preliminary Results of Ancillary Safety Analyses Supporting TREAT LEU Conversion Activities

The Transient Reactor Test Facility (TREAT), located at Idaho National Laboratory (INL), is a test facility designed to evaluate the performance of reactor fuels and materials under transient accident conditions. The facility, an air-cooled, graphite-moderated reactor designed to utilize fuel containing high-enriched uranium (HEU), has been in non-operational standby status since 1994. Currently, in support of the missions of the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Material Management and Minimization (M3) Reactor Conversion Program, a new core design is being developed for TREAT that will utilize low-enriched uranium (LEU). The primary objective of this conversion effort is to design an LEU core that is capable of meeting the performance characteristics of the existing HEU core. Minimal, if any, changes are anticipated for the supporting systems (e.g. reactor trip system, filtration/cooling system, etc.); therefore, the LEU core must also be able to function with the existing supporting systems, and must also satisfy acceptable safety limits. In support of the LEU conversion effort, a range of ancillary safety analyses are required to evaluate the LEU core operation relative to that of the existing facility. These analyses cover neutronics, shielding, and thermal hydraulic topics that have been identified as having the potential to have reduced safety margins due to conversion to LEU fuel, or are required to support the required safety analyses documentation. The majority of these ancillary tasks have been identified in [1] and [2]. The purpose of this report is to document the ancillary safety analyses that have been performed at Argonne National Laboratory during the early stages of the LEU design effort, and to describe ongoing and anticipated analyses. For all analyses presented in this report, methodologies are utilized that are consistent with, or improved from, those used in analyses for the HEU Final Safety Analysis Report (FSAR) [3]. Depending on the availability of historical data derived from HEU TREAT operation, results calculated for the LEU core are compared to measurements obtained from HEU TREAT operation. While all analyses in this report are largely considered complete and have been reviewed for technical content, it is important to note that all topics will be revisited once the LEU design approaches its final stages of maturity. For most safety significant issues, it is expected that the analyses presented here will be bounding, but additional calculations will be performed as necessary to support safety analyses and safety documentation. It should also be noted that these analyses were completed as the LEU design evolved, and therefore utilized different LEU reference designs. Preliminary shielding, neutronic, and thermal hydraulic analyses have been completed and have generally demonstrated that the various LEU core designs will satisfy existing safety limits and standards also satisfied by the existing HEU core. These analyses include the assessment of the dose rate in the hodoscope room, near a loaded fuel transfer cask, above the fuel storage area, and near the HEPA filters. The potential change in the concentration of tramp uranium and change in neutron flux reaching instrumentation has also been assessed. Safety-significant thermal hydraulic items addressed in this report include thermally-induced mechanical distortion of the grid plate, and heating in the radial reflector.

Brunett, A. J.↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal-Hydraulic Results for the Boiling Water Reactor Dry Cask Simulator.

The thermal performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both aboveground and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of this investigation was to produce validation-quality data that can be used to test the validity of the modeling presently used to determine cladding temperatures in modern vertical dry casks. These cladding temperatures are critical to evaluate cladding integrity throughout the storage cycle. To produce these data sets under well-controlled boundary conditions, the dry cask simulator (DCS) was built to study the thermal-hydraulic response of fuel under a variety of heat loads, internal vessel pressures, and external configurations. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplified interpretation of results. Two different arrangements of ducting were used to mimic conditions for aboveground and belowground storage configurations for vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured throughout the test assembly. The induced air mass flow rate was measured for both the aboveground and belowground configurations. In addition, the impact of cross-wind conditions on the belowground configuration was quantified. Over 40 unique data sets were collected and analyzed for these efforts. Fourteen data sets for the aboveground configuration were recorded for powers and internal pressures ranging from 0.5 to 5.0 kW and 0.3 to 800 kPa absolute, respectively. Similarly, fourteen data sets were logged for the belowground configuration starting at ambient conditions and concluding with thermal-hydraulic steady state. Over thirteen tests were conducted using a custom-built wind machine. The results documented in this report highlight a small, but representative, subset of the available data from this test series. This addition to the dry cask experimental database signifies a substantial addition of first-of-a-kind, high-fidelity transient and steady-state thermal-hydraulic data sets suitable for CFD model validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Analysis of Damage to MPFDs Caused by Reactor Pulses

The need for next-generation, accident-tolerant fuels has generated significant interest in the restart of domestic fuels testing at the Transient Reactor Test (TREAT) facility. The TREAT reactor is designed to produce large, transient fluxes that replicate the effects of a wide variety of accident conditions on an irradiated fuel sample. Peak powers generated during short pulses approach 20 GW with a neutron flux of approximately 10{sup 17} n cm{sup -2} s{sup -1}. As part of the restart effort, new vehicle designs are being explored for sample irradiation, including the Static Environment Rodlet Transient Test Apparatus (SERTTA) and variants. As part of the SERTTA designs, micro-pocket fission detectors (MPFDs) are being explored for localized flux measurements before, during, and after transient operations. These detectors are also being considered as part of future, core-wide instrumentation for the TREAT reactor. However, the high fluxes associated with the pulses in the TREAT core present certain thermodynamic concerns given their intensity and the amount of energy they will release within the MPFDs within such a short amount of time. Assuming each fission that occurs in a MPFD results in a fission fragment depositing 85 MeV of energy in the substrate on average and each MPFD has 0.5 μg of natural uranium deposited on it, a 100 ms long pulse in the TREAT reactor at 1017 n cm{sup -2} s{sup -1} flux will produce approximately 4.6 x 10{sup 6} fissions in an MPFD. This pulse deposits 6.3 x 10{sup -5} J in the substrate over a 100 ms duration. That amount of energy is sufficient to melt roughly 33% of the Pt under the UO{sub 2} deposition or a circular spot with a diameter of approximately 860 μm. Of course, the above estimate makes a number of simplifying assumptions and ignores heat transfer, but does serve to illustrate the point that this rapid heating effect could be detrimental to the integrity and life of these in-core MPFDs. To study how these layers are affected by large transient neutron fluxes, five samples were prepared, pre-analyzed, and then subjected to a pulse in the central thimble of the Kansas State University TRIGA Mark II reactor to a peak power of 1.58 GW. After being allowed to decay to safer radiation levels, the sample substrates and coatings were inspected using scanning electron microscopy (SEM) to identify any changes to their surface morphology. Indeed, certain changes were found and are discussed in greater detail in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MECHANISTIC MULTIPHYSICS MODELING OF CLADDING RUPTURE IN NUCLEAR FUEL RODS DURING LOSS-OF-COOLANT ACCIDENT CONDITIONS

The Loss of Coolant Accident (LOCA) is a design basis accident that is included as part of the safety analysis of nuclear power plants. As the nuclear industry desires to increase the cycle length and discharge burnup of existing nuclear power plants they must demonstrate safe operation during a LOCA on high burnup fuel. During a LOCA transient on high burnup fuel rods, the rods may undergo a process known as fuel fragmentation, relocation, and dispersal (FFRD). To permit dispersal, the cladding encapsulating the fuel must rupture with an opening size large enough to allow the fragmented fuel particles to release. Current licensing tools used by industry and the United States Nuclear Regulatory Commission are limited in geometric fidelity and materials that can be analyzed. These simulation tools generally employ a quasi-two-dimensional (1.5D or Layered1D) or 2D-RZ axisymmetric geometric representations exclusively. While a valid approach under some instances, there are times when important physics have an asymmetric behavior in the fuel rod. Examples include fuel fragmentation, thermal-hydraulic boundary conditions, and cladding rupture, all of which are important for LOCA analysis. As industry pursues burnup extensions it must be demonstrated that fuel dispersal can be mitigated or eliminated. To do this, an understanding of the rupture opening after cladding failure is required. This work presents the development of a model for predicting the size and location of the rupture opening in failed fuel rods during LOCA conditions using advanced modeling and simulation tools. In order to supply the rupture model with appropriate boundary conditions, improvements to fuel fragmentation, axial relocation and oxidation modeling were required. First, the eXtended Finite Element Method (XFEM) is used to mechanistically predict the number of fuel fragments that form due to material strength randomization, criteria for strength randomization, mesh density, power ramping rates and irradiation effects. These predictions with associated uncertainty were compared to empirical correlations developed for UO2 verifying that they can be used with increased confidence in subsequent axial relocation analyses. Secondly, a new first-of-its-kind Layered2D computational framework was developed that provides the ability to apply azimuthally varying boundary conditions while providing discrete layers to track fuel movement during the LOCA. An existing fuel axial relocation model developed for Layered1D was extended to work within the Layered2D framework. A large sensitivity study was performed on the initial version of the model to identify modeling parameters of particular importance, with the emissivity used for radiation after blowdown being the primary source of uncertainty. Then, a simplistic approach to incorporate mechanical degradation of the cladding due to oxidation was also developed to investigate the impact of reduced cladding thickness on predictions of the time to failure of cladding tubes. It was found that the cladding will typically rupture prior to a reduction in thickness that is sufficient to impact the rupture behavior. A model was then developed for predicting cladding rupture that transfers the cladding surface temperatures, rod internal and external pressures, fast neutron fluence, and fast neutron flux from a more detailed Layered1D, Layered2D, or 2D-RZ analysis to a 3D cladding only analysis. Comparisons of the rupture model to a few experiments indicate reasonable predictions. The rupture model was then applied to two accident tolerant fuel concepts (FeCrAl and Cr-coated Zircaloy) where it predicted that both ATF concepts would have smaller rupture openings and delayed rupture times than the standard Zircaloy-4 cladding material under identical loading conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IAEA Coordinated Research Project on HTGR Physics, Thermal Hydraulics, and Depletion Uncertainty Analysis: PHISICS/RELAP5-3D Results for the Phase III Coupled Core Exercises

This report details the Parallel and Highly Innovative Simulation for INL Code System (PHISICS)/Reactor Excursions and Leak Analysis Program (RELAP5)-3D results obtained for the neutronics stand-alone core exercises defined for Phase II of the International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) on high-temperature gas cooled reactor (HTGR) uncertainty analysis in modeling (UAM). The Phase II models and results are linked to the earlier Standardized Computer Analyses for Licensing Evaluation (SCALE)/Sampler/New ESC-based Weighting Transport (NEWT) data generated for the lattice physics (lattice) stage Phase I of the CRP. The focus of this report is the propagation of cross-section uncertainties from the lattice to the core calculation (core) phase of the prismatic 350 megawatt (MW) General Atomics (GA) Modular HTGR (MHTGR). The Phase II neutronics exercises consist of two sub-cases (II-2a and II-2b) specified for the fresh and mixed core loading of the MHTGR-350 prismatic high-temperature reactor design. Exercises II-2a and II-2b are performed without temperature feedback using isothermal temperature profiles. For the nominal lattice physics (i.e., best-estimate) model, a series of fresh and depleted single block and super cell SCALE/KENO and SCALE/NEWT models were developed at Idaho National Laboratory (INL) to assess the impact of spectral effects on the few-group cross sections. A combination of these lattice cells were used in a super cell calculation to construct 8-group cross-section libraries for use in the INL-developed PHISICS/RELAP5-3D code suite. The block-level homogenized libraries were assigned to the 220 fuel zones utilized in the MHTGR-350 PHISICS core model, according to the fresh and mixed fresh/depleted core loading pattern. In order to evaluate the effect of uncertainty propagation, several sets consisting of 1,000 perturbed NEWT lattice and PHISICS/RELAP5-3D core calculations were performed using the SCALE 6.2 ENDF/B-VII.1 cross-section co-variance data and the stochastic sampling module Sampler in SCALE 6.2.0. The Figures of Merit (FOM) investigated include the mean and standard deviation uncertainty values obtained for the eigenvalues, control rod worth values, block-averaged power profiles, power axial offsets, and isothermal temperature feedback coefficients. A sensitivity study on the main nuclide reaction contributors to the FOM uncertainties has not yet been performed since the SCALE/PHISICS/RAVEN coupling with ENDF/B-VII co-variance data is still being developed. It was found that uncertainties in the cross sections lead to uncertainties in the local power values of up to 1.5%. The variances between the fresh and mixed/depleted core models are not as large as the axial variations between the top and bottom within each core model. The core eigenvalue uncertainty is approximately 0.5%, which is significant in comparison to typical eigenvalue difference targets (less than ~0.1% for LWRs). The power peaking and axial offset uncertainties are smaller (0.10% – 0.15%) and probably below the level of significance in typical core design metrics. The use of an 8-group energy structure slightly under-estimates some of the uncertainties, but in absolute terms, the uncertainty results are reasonably close to the 26-group results. The 26- and 8-group mean and nominal results differ by a larger degree, and if it can be afforded in terms of calculation resources, the 26-group structure should be used for HTGR calculations. The 8-group structure can, however, still be useful for reasonably accurate uncertainty assessments of transient cases where computational time is important. It was furthermore found that the use of a super cell during the cross-section generation process for better representation of the spectral environment at the core periphery did not lead to significant changes in the core eigenvalues, axial offset, and power peaking uncertainties. The impact of the super cell cross sections on the nominal and mean eigenvalues is, however, important enough (0.6% – 1.1% lower) to justify the use of these super cells for HTGR core simulation to represent the softer spectral environment in the core peripheral regions for nominal best-estimate calculations. The use of super cells for HTGR uncertainty studies is, therefore, not strictly necessary, but the improvements in nominal results could justify their use.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗