Search NASA⌕ Search

SEARCH · Search NASA

Results for “Usability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

ARC Software Validation Work for the FFTF Reactor

Extensive efforts have been carried out at ANL for the verification and validation of the Argonne Reactor Codes (ARC) software package currently used for the design of Versatile Test Reactor (VTR). The ARC software package consists of steady state neutronics and thermal hydraulics modeling capabilities which are being used by the VTR program to develop most of the VTR reactor design details which will be part of the licensing application. It is anticipated that this software will continue to be used for the design work and for initial operations although additional software may be introduced at a later time. The validation work was focused primarily on obtaining validation data consistent with VTR and usable for the ARC software. Because no critical facilities or operating fast spectrum reactors are available to do experiments for the VTR, the next best option is to identify historical experimental data that can be used as validation data. Early on in VTR, the ZPPR-15 set of experiments was identified as good validation data because of 1) the availability and quality of the data, 2) existing staff that are already familiar with the experimental machine and measurements, 3) most of the ZPPR-15 loadings of interest have already been processed into ARC models, and 4) a full uncertainty quantification has already been done for several loadings of ZPPR-15. The FFTF startup and operations data was identified as the most consistent reactor type that has validation data usable for VTR. Finally, the EBR-II fuel depletion measurements were identified as the best available validation data for VTR. It is important to note that both the FFTF and EBR-II reactors typically come with higher uncertainties than the ZPPR. In the frame of the discussed verification and validation efforts, the present document discusses the analysis of selected FFTF measurements included in the benchmark specifications of the International Reactor Physics Experiment (IRPhE) handbook. The FFTF reactor core configurations from the benchmark specification are presented in Section 2. The analysis is performed with the use of the ARC code suite available at ANL for fast reactor studies and is discussed in Section 3. The reactor parameters from the benchmark include criticality, neutron spectra, effective delayed neutron spectra, control rod worth, isothermal temperature coefficient and low energy gamma-ray spectra. The calculated values and the comparison with the experimental data is discussed in Sections 4 to 9 for each considered reactor parameter. Finally, conclusions are presented in Section 10.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Practical Probabilistic Programming

Recent advances in probabilistic programming languages (PPLs) have provided the capability for exact inference: computing a closed-form probability distribution for a given probabilistic program. In particular, the new language Roulette uses a language oriented programming (LOP) approach, wherein analysts build new programming languages on top of a set of primitives provided by Roulette, which then translates these structures into a weighted model counting problem which can be solved by automated reasoning tools. However, because Roulette provides few convenience features, developing these new languages is challenging even for expert users. We developed a standard library of common probability functions for Roulette with the goal of improved usability. This included approximation of continuous probability density functions using discrete probability mass functions. We demonstrated this approach by modeling a cosmic ray striking a RAM controller. We found that Roulette provides a powerful interface for highly expressive probabilistic programs to be generated. In collaboration with the NNSA Advanced Simulation and Computing program, which resulted in development of a tool called Circulette, we were able to model complex circuits expressed in Verilog using probabilistic programs with an expressivity not previously possible. Our research question that motivated the development of a Roulette standard library was to determine whether non-experts could use a PPL to model relevant problems regarding radiation effects on microelectronics. This standard library improved the expressivity of Roulette by implementing common probability density functions, mathematical operators on distributions, and support for empirical distributions. While Roulette is a powerful modeling language, the untyped, LOP approach makes error messages difficult to understand and requires expert aid. We recommend further research on Roulette, especially with its error messages, to enable improved usability. At the same time, this project demonstrated that for users familiar with Roulette and the LOP approach, Roulette provides powerful new capabilities that can be integrated with other Sandia modeling capabilities.

97 MATHEMATICS AND COMPUTING↗

Development of Large Bore Rabbit Capsules in Support of BWR Cladding Irradiations in HFIR

The High Flux Isotope Reactor (HFIR) is an ideal tool for materials irradiation testing because of its intense steady-state neutron flux. Many programs take advantage of HFIR’s central flux trap for irradiation experiments using capsules, also known as rabbits, to support advanced materials development and reactor design. The facility that makes up the HFIR flux trap has recently undergone a design change that increases the HFIR primary coolant volumetric flow rate by removing restrictions in the system. As a result, the usable cross-sectional area within the facility increased, opening the door to increase the cross-sectional area of the rabbit capsules that fill the facility. This report documents a new large-diameter rabbit housing that increases the usable volume within the rabbit capsule by 22.6%. However, challenges arise with increasing the capsule size, such as establishing a new maximum capsule operating pressure and determining the thermal-hydraulic characteristics. This report addresses those challenges with previously adopted HFIR safety methods. The rupture pressure of the rabbit housings is demonstrated while verifying that capsule swelling during and after rupture will not block coolant flow. Then, a safety factor is applied to ascertain an administrative operating pressure. Additionally, the thermal-hydraulic performance of the HFIR facility filled with large-diameter rabbit capsules is shown to not violate previously determined safety criteria. Next, heat transfer coefficients are determined for use in design calculations. Furthermore, this report gives an example of internal configurations for the new, larger rabbit capsules that use relevant boiling water reactor (BWR) cladding geometry. Finally, this report documents an example thermal design performance for a rabbit capsule containing six gauge-curved tensile tube specimens. The thermal performance gives predicted temperature distributions within the capsule and shows the expected temperature of the passive thermometers for post-irradiation temperature comparisons.

99 GENERAL AND MISCELLANEOUS↗

Development of Large Bore Rabbit Capsules in Support of BWR Cladding Irradiations in HFIR

The High Flux Isotope Reactor (HFIR) is an ideal tool for materials irradiation testing because of its intense steady-state neutron flux. Many programs take advantage of HFIR’s central flux trap for irradiation experiments using capsules, also known as rabbits, to support advanced materials development and reactor design. The facility that makes up the HFIR flux trap has recently undergone a design change that increases the HFIR primary coolant volumetric flow rate by removing restrictions in the system. As a result, the usable cross-sectional area within the facility increased, opening the door to increase the cross-sectional area of the rabbit capsules that fill the facility. This report documents a new large-diameter rabbit housing that increases the usable volume within the rabbit capsule by 22.6%. However, challenges arise with increasing the capsule size, such as establishing a new maximum capsule operating pressure and determining the thermal-hydraulic characteristics. This report addresses those challenges with previously adopted HFIR safety methods. The rupture pressure of the rabbit housings is demonstrated while verifying that capsule swelling during and after rupture will not block coolant flow. Then, a safety factor is applied to ascertain an administrative operating pressure. Additionally, the thermal-hydraulic performance of the HFIR facility filled with large-diameter rabbit capsules is shown to not violate previously determined safety criteria. Next, heat transfer coefficients are determined for use in design calculations. Furthermore, this report gives an example of internal configurations for the new, larger rabbit capsules that use relevant boiling water reactor (BWR) cladding geometry. Finally, this report documents an example thermal design performance for a rabbit capsule containing six gauge-curved tensile tube specimens. The thermal performance gives predicted temperature distributions within the capsule and shows the expected temperature of the passive thermometers for post-irradiation temperature comparisons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

JGI Computing 5-Year Strategic Plan

A broad range of scientific goals and a similarly diverse set of consumers drive the informatics requirements and computing needs of the JGI. The scope of work in this area encompasses not only the informatics and analysis pipelines in support of the PGF sequence production, but also the integration of data from a variety of sources and sophisticated large scale analyses led by investigators within JGI and driven by the user science community. In laying out a forward looking strategy, the full range of these activities need to be examined together to build a comprehensive program that will serve as a catalyst for the DOE research community. The science landscape envisioned in the overall strategic plan calls for significantly increasing the throughput of microbial genomes sequenced to cover their phylogenetic space and building a set of finished reference plant genomes to enable DOE relevant science. Additionally, the established impact of microbial communities on global energy cycles and their potential in remediation endeavors, warrant building upon JGI's established expertise in metagenomic analysis. Not only is each of these program areas relevant and exciting in their own right, but they also can and should be undertaken in a way that allows synthesis across domains (e.g. utilize knowledge from sequence of plants and the soil from which they are grown). Both dramatic increases in the scale of genomic data collection and the synergistic potential of integrating data across domains will demand new strategies in the informatics pipeline within the JGI and in the facility's approach to computational analysis and user access to the data in aggregated form. In addition to a robust and scalable informatics infrastructure, fulfilling the strategic science goals of the JGI will require ongoing investment in usability of the data, to ensure that the data collected will be used to maximal effect. It must be recognized that 'usability' will have a different appearance depending on the specific user base, and the JGI has several distinct classes of users it must enable to be successful. For some, rapid and convenient dissemination of the sequence data will be sufficient to enable their external research. For others, JGI hosted analysis tools and collaborative environments will be required to catalyze individual or team research. Finally, and significantly, there are genomic scientists within the JGI, often working closely with external collaborators, who rely on the ability to devise project-dependent and often very large scale customized analyses that result in publicly available tools. A successful strategy will require effort to satisfy each of these user classes, and careful attention to economies of software reuse and extensibility. There are only a handful of sequencing facilities worldwide that operate at the scale of the JGI's Production Genomics Facility, and these are devoted almost entirely to sequencing driven by biomedical applications. The PGF therefore fulfills a unique and vital role as a resource for genomic studies of DOE relevance. Like the other large-scale facilities, JGI has been carefully following the development of 'next-generation' sequencing technologies, and clearly must continue to refresh its instrumentation as advances are made. Critical to advances in sequencing technology are the computational infrastructure advances that are required to turn raw sequence into quality data. This is one area where JGI can leverage the broader sequencing community's investment in technology development, adopting the best practices and software for sequence processing and assembly. JGI can add unique value by further developing annotation pipelines and tools that serve to build an integrated framework where the Institute's complementary science components can be viewed in a larger 'systems' perspective than is currently possible. As technology, tools, and infrastructure advance, JGI is uniquely positioned in its ability complement core PGF expertise with a diverse set of capabilities provided by partners within the broader community that forms the Institute. The coming decade promises radical change in the field, and the ability to quickly recognize developing areas and nimbly build appropriate partner teams will be vital to maximally capitalize on the growing base of data collection capabilities. This dynamic team science environment will require an underlying computational environment that can accommodate innovative ideas and processes. This will be key to the success of the scientific goals of the JGI.

09 BIOMASS FUELS↗

Quality Assurance of ARM Program Climate Research Facility Data

This report documents key aspects of the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) data quality assurance program as it existed in 2008. The performance of ACRF instruments, sites, and data systems is measured in terms of the availability, usability, and accessibility of the data to a user. First, the data must be available to users; that is, the data must be collected by instrument systems, processed, and delivered to a central repository in a timely manner. Second, the data must be usable; that is, the data must be inspected and deemed of sufficient quality for scientific research purposes, and data users must be able to readily tell where there are known problems in the data. Finally, the data must be accessible; that is, data users must be able to easily find, obtain, and work with the data from the central repository. The processes described in this report include instrument deployment and calibration; instrument and facility maintenance; data collection and processing infrastructure; data stream inspection and assessment; the roles of value-added data processing and field campaigns in specifying data quality and haracterizing the basic measurement; data archival, display, and distribution; data stream reprocessing; and engineering and operations management processes and procedures. Future directions in ACRF data quality assurance also are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Density of Gadolinium Nitrate Solutions for the High Flux Isotope Reactor

In late 1992, the High Flux Isotope Reactor (HFIR) was planning to switch the solution contained in the poison injection tank from cadmium nitrate to gadolinium nitrate. The poison injection system is an emergency system used to shut down the reactor by adding a neutron poison to the cooling water. This system must be able to supply a minimum of 69 pounds of gadolinium to the reactor coolant system in order to guarantee that the reactor would become subcritical. A graph of the density of gadolinium nitrate solutions over a concentration range of 5 to 30 wt% and a temperature range of 15 to 40{sup o}C was prepared. Routine density measurements of the solution in the poison injection tank are made by HFIR personnel, and an adaptation of the original graph is used to determine the gadolinium nitrate concentration. In late 2008, HFIR personnel decided that the heat tracing that was present on the piping for the poison injection system could be removed without any danger of freezing the solution; however, the gadolinium nitrate solution might get as cold as 5{sup o}C. This was outside the range of the current density-concentration correlation, so the range needed to be expanded. This report supplies a new density-concentration correlation that covers the extended temperature range. The correlation is given in new units, which greatly simplifies the calculation that is required to determine the pounds of gadolinium in the tank solution. The procedure for calculating the amount of gadolinium in the HFIR poison injection system is as follows: (1) Calculate the usable volume in the system; (2) Measure the density of the solution; (3) Calculate the gadolinium concentration using the following equation: Gd(lb/ft{sup 3}) = measured density (g/mL) x 34.681 - 34.785; (4) Calculate the amount of gadolinium in the system using the following equation: Amount of Gd(lb) = Gd concentration (lb/ft{sup 3}) x usable volume (ft{sup 3}). The equation in step 3 is exact for a temperature of 5{sup o}C, and overestimates the gadolinium concentration at all higher temperatures. This guarantees that the calculation is conservative, in that the actual concentration will be at least as high as that calculated. If an additional safety factor is desired, it is recommended that an administrative control limit be set that is higher than the required minimum amount of gadolinium.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Methodology for Evaluating Operator Usage of Machine Learning Recommendations for Power Grid Contingency Analysis

This work presents the application of a methodology to measure domain expert trust and workload, elicit feedback, and understand the technological usability and impact when a machine learning assistant is introduced into contingency analysis for real-time power grid simulation. The goal of this framework is to rapidly collect and analyze a broad variety of human factors data in order to accelerate the development and evaluation loop for deploying machine learning applications. We describe our methodology and analysis, and we discuss insights gained from a pilot participant about the current usability state of an early technology readiness level (TRL) artificial neural network (ANN) recommender.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ocean Energy: Markets - Currency - Impact. Dimension of & Choices in the Technology Development Space: Preprint

This paper presents considerations of the employment of ocean wave energy to support different energy demand side applications. The key aspect in these considerations is the wave energy supported achievable positive impact and associated tangible contribution in service of common societal good and of the natural commons. The level of impact that can be delivered is dependent on both, the level of contribution of the supported energy use application, and the compatibility and unique suitability of the wave energy resource and its characteristics with the needs of the application. Thus, a variety of ocean wave energy markets, the key value indicators or "currency' in which these markets trade the value delivered and the achievable positive impact, are reflected upon. Ocean wave energy supported acquisition of high quality ocean system data across a wide spectrum of system properties is identified as a highly impactful application enabling and/or improving a comprehensive range of impactful ocean system activities. The technology development process towards these markets and desired impacts requires relevant technology development progress guidance and metrics. Going beyond technology readiness levels and technology performance levels, the notion of further technology development progress scales towards high impact and high contribution are proposed. These scales and the associated technology properties can be regarded as additional technology development dimensions to span-up the technology development space in which desired system capability and functional requirement choices and subsequent ideation, innovation, research and technology development decisions can and are to be made.

data market↗

Sky Residual Correction

The near-infrared is populated by numerous emission lines radiated from the Earth’s atmosphere, and these emission lines are often several orders of magnitude brighter in intensity than the typical astrophysical science target. The subtraction of these emission lines, sky subtraction, can create large systematic errors in ground-based astronomical spectra effectively limiting the number of usable resolution elements. A more effective sky subtraction, and the reduction of the systematic errors due to the sky subtraction process, is a major hurdle which ground-based astronomy must overcome to increase the amount of usable spectrum, and to be able to observe fainter scientific targets. Large high-quality data sets such as the Sloan Digital Sky Survey (SDSS) in themselves present opportunities for a reduction of the systematic sky subtraction errors through self-calibration. The sky residual correction method of Wild and Hewett is one such self-calibration technique which uses principal component analysis to reduce the systematic sky residual errors present in SDSS spectra. We apply sky residual corrections to the SDSS, Baryon Oscillation Spectroscopic Survey, and Apache Point Observatory Galactic Evolution Experiment data sets to optimize the number of subtraction components, and to quantify the reduction of the systematic errors in the science spectra. Finally as a proof of concept we use the sky-residual-corrected SDSS luminous red galaxy spectra to search for gravitationally lensed emission line Galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-infrared Spectral Characterization of Solar-type Stars in the Northern Hemisphere

Although solar-analog stars have been studied extensively over the past few decades, most of these studies have focused on visible wavelengths, especially those identifying solar-analog stars to be used as calibration tools for observations. As a result, there is a dearth of well-characterized solar analogs for observations in the near-infrared, a wavelength range important for studying solar system objects. We present 184 stars selected based on solar-like spectral type and V−J and V−K colors whose spectra we have observed in the 0.8–4.2 μm range for calibrating our asteroid observations. Each star has been classified into one of three ranks based on spectral resemblance to vetted solar analogs. Of our set of 184 stars, we report 145 as reliable solar-analog stars, 21 as solar analogs usable after spectral corrections with low-order polynomial fitting, and 18 as unsuitable for use as calibration standards owing to spectral shape, variability, or features at low to medium resolution. We conclude that all but five of our candidates are reliable solar analogs in the longer wavelength range from 2.5 to 4.2 μm. The average colors of the stars classified as reliable or usable solar analogs are V−J = 1.148, V−H = 1.418, and V−K = 1.491, with the entire set being distributed fairly uniformly in R.A. across the sky between −27° and +67° in decl.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral reflectance characteristics and automated data reduction techniques which identify wetland and water quality conditions in the Chesapeake Bay

Progress on research designed to test the usability of multispectral, high altitude, remotely sensed data to analyze ecological and hydrological conditions in estuarine environments is presented. Emphasis was placed on data acquired by NASA aircraft over the Patuxent River Chesapeake Bay Test Site, No. 168. Missions were conducted over the Chesapeake Bay at a high altitude flight of 18,460 m and a low altitude flight of 3070. The principle objectives of the missions were: (1) to determine feasibility of identifying source and extent of water pollution problems in Baltimore Harbor, Chesapeake Bay and major tributaries utilizing high altitude, ERTS analogous remote sensing data; (2) to determine the feasibility of mapping species composition and general ecological condition of Chesapeake Bay wetlands, utilizing high altitude, ERTS analogous data; (3) to correlate ground spectral reflectance characteristics of wetland plant species with tonal characteristics on multispectral photography; (4) to determine usefulness of high altitude thermal imagery in delinating isotherms and current patterns in the Chesapeake Bay; and (5) to investigate automated data interpretive techniques which may be usable on high altitude, ERTS analogous data.

Anderson, R. R.↗

Rocket/Nimbus Sounder Comparison (RNSC)

The experimental results for radiance and temperature differences in the Wallops Island comparisons indicate that the differences between satellite and rocket systems are of the same order of magnitude as the differences among the various satellite and rocket sounders. The Arcasondes produced usable data to about 50 km, while the Datasondes require design modification. The SIRS and IRIS soundings provided usable data to 30 mb; extension of these soundings was also investigated.

Source record↗

A contribution to the development of an economic atlas of the Houston Area Test Site

An outine description of the Houston Area Test Site was prepared, in the form of an atlas-catalog of Universal Transverse Mercator grid coordinate locations, building on the manufacturing sector and expanding along agreed lines as far as possible. It was concluded that (1) the effort expended in securing and verifying the locations of larger manufacturing plants yielded 5,000-plus usable entries, in addition to certain valuable conclusions about the general feasibility of obtaining ground information by economic sector; (2) on the basis of the number and the quality of the usable entries obtained, the resources expended on nonmanufacturing sectors and on historical data cannot be wholly justified; and (3) even without the 5,000-odd locations of completely satisfactory quality, the relatively modest cost of this pilot study secured enough data to provide a sound basis for obtaining feasibly and systematically some appropriate ground information on almost any economic or social activity, together with some indication of their relative areal and economic significance.

Source record↗

The uses and limitations of HF standard broadcasts for time and frequency comparison

The most practical methods of using high-frequency (HF) broadcasts for frequency and time comparison are reviewed. Although standard broadcast and receiving equipment has improved vastly throughout the past fifty years, the HF propagation medium is no more stable today than it was a half century ago. Doppler shift resulting from changes in the effective height of the ionosphere typically limits the usable accuracy of received high frequencies to a few parts in 10 to the 7th power. At locations beyond groundwave range of the transmitter, uncertainties in path delay generally restrict the usable accuracy of HF time signals to the order of a millisecond. Signal-averaging techniques are sometimes employed to extract frequency or time signals from a noisy background.

Stanley, J. T.↗

Fabrication and evaluation of polymeric early-warning fire-alarm devices

The electrical resistivities were investigated of some polymers known to be enhanced by the presence of certain gases. This was done to make a device capable of providing early warning to fire through its response with the gases produced in the early phases of combustion. Eight polymers were investigated: poly(phenyl acetylene), poly(p-aminophenyl acetylene), poly(p-nitrophenyl acetylene), poly(p-formamidophenyl acetylene), poly(ethynyl ferrocene), poly(ethynyl carborane), poly(ethynyl pyridine), and the polymer made from 1,2,3,6 tetramethyl pyridazine. A total of 40 usable thin-film sandwich devices and a total of 70 usable interdigitated-electrode lock-and-key devices were fabricated. The sandwich devices were used for measurements of contact linearity, polymer conductivity, and polymer dielectric constant. The lock-and-key devices were used to determine the response of the polymers to a spectrum of gases that included ammonia, carbon nonoxide, carbon dioxide, sulfur dioxide, ethylene, acrolein, water vapor, and normal laboratory air. Strongest responses were to water vapor, ammonia, and acrolein, and depending on the polymer, weaker responses to carbon dioxide, sulfur dioxide, and carbon monoxide were observed. A quantitative theory of device operation, capable of accounting for observed device leakage current and sensitivity, was developed. A prototype detection/alarm system was designed and built for use in demonstrating sensor performance.

Senturia, S. D.↗

Error Analysis of the Shuttle Reaction Control System Propellant Gaging Module

An investigation of the Shuttle Reaction Control System (RCS) propellant gaging module has revealed that the gaging errors due to the combined effects of random instrumentation measurement errors and propellant loading uncertainties are non-linear over the range of the propellant quantity gage (0-100%), with the largest error occurring at the zero point. When the RCS propellant tanks are filled to contain 100% of the maximum usable propellant, the largest gaging error was determined to be 3.9% for the fuel and 5.4% for the oxidizer. When the RCS propellant tanks initially contain 50% of the maximum usable propellant, the largest gaging error increases to 4.0% for the fuel and 5.6% for the oxidizer.

Duhon, D. D.↗

Modified MEE Industries static thermal gradient diffusion cloud chamber

The experiments performed at the Workshop were undertaken to confirm the calculated sample volume, determine the usable range of supersaturation, and minimum detectable size. Comparison of absolute CCN concentrations with other state-of-the-art continuous flow diffusion chambers at supersaturations near 1 percent indicated that the volume used produced CCN concentrations well within the range of CCN concentrations determined at the workshop. This agreement is interpreted to mean the sample volume was correct. Direct measurements of the beam geometry done in the laboratory indicated a factor of 4-5 error. This error is apparently due to the larger apparent visible beam diameter versus the actual usable beam diameter given the droplet illumination, chamber optical geometry, microscope optics and film characteristics.

Borys, R. D.↗